Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Xray Sci Technol ; 28(2): 243-254, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31985486

RESUMO

OBJECTIVE: Since most radiation treatment plans are based on computed tomography (CT) images, which makes it difficult to define the targeted tumor volume located near a metal implant, this study aims to evaluate and compare three treatment plans in order to optimally reduce geometrical uncertainty in external radiation treatment of localized prostate cancer. METHODS: Experimental subjects were three prostate patients with bilateral hip prosthesis who had undergone radical radiotherapy. The treatment plans were five-field three-dimensional conformal radiation therapy (3D-CRT), fixed 5-field intensity-modulated radiation therapy (IMRT) using similar gantry angles, and single-arc volumetric modulated arc therapy (VMAT). The monitor units (MUs), dose volume histograms (DVHs), the dose indices of planning target volume (PTV), clinical target volume (CTV) and rectum were compared among the three techniques. The geometrical uncertainties were evaluated by shifting the iso-center (2- 10 mm in the anterior, posterior, left, right, superior, and inferior directions). The CTV and rectum dose indexes with and without the iso-center shifts were compared in each plan. RESULTS: The Conformity Index of PTV were 1.35 in 3D-CRT, 1.12 in IMRT, and 1.04 in VMAT, respectively. The rectum doses in 3D-CRT are also higher than those in IMRT and VMAT. The iso-center shift little affected the CTV dose when smaller than the margin size. The rectum dose increased especially after a posterior shift. Additionally, this dose increase was larger in the VMAT plan than in the 3D- CRT plan. However, the VMAT achieved a superior rectum DVH to that of 3D- CRT, and this effect clearly exceeded the rectum-dose increase elicited by the iso-center shift. CONCLUSION: For radiotherapy treatment of localized prostate cancer in patients with hip prosthesis, the dose distribution was better in the VMAT and Metal Artifact Reduction (MAR)-CT image methods than the conventional methods. Because the anatomical structure of the male pelvic region is relatively constant among individuals, we consider that VMAT is a valid treatment plan despite analyzing just three cases.


Assuntos
Prótese de Quadril , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Incerteza , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
2.
Int J Clin Oncol ; 23(2): 361-367, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29151227

RESUMO

BACKGROUND: To evaluate the relationship between biochemical recurrence and post-radiation prostate-specific antigen (PSA) kinetics in patients with localized prostate cancer treated by radiotherapy with various durations of androgen deprivation therapy (ADT). METHODS: We reviewed our single-institution, retrospectively maintained data of 144 patients with T1c-T3N0M0 prostate cancer who underwent three-dimensional conformal radiotherapy (3D-CRT) between December 2005 and December 2015 and 113 patients were fulfilled the inclusion criteria. In this cohort, 3D-CRT was delivered with a dose in the range from 70.0 to 72.0 Gy with ADT. All patients received ADT as concurrent regimens. Biochemical recurrence was defined on the basis of the following: "PSA nadir + 2.0 ng/ml or the clinical judgement of attending physicians". Kaplan-Meier, log-rank, and Cox regression analyses were carried out. RESULTS: The median follow-up period was 54.0 months. The median duration of ADT was 17 months (interquartile range, 10-24 months). There was a trend toward statistical significant correlation between post-radiation PSA decline rate of ≥ 90% and PSA recurrence (p = 0.056). The same correlation could be observed in D'Amico high-risk patients (p = 0.036). However, it was not observed between PSA nadir and PSA recurrence (p = 0.40) in univariate analysis. Furthermore, multivariate analysis showed that post-radiation PSA decline rate of ≥ 90% was a significant predictor of biochemical recurrence in patients who received radiotherapy with various durations of ADT (p = 0.044). CONCLUSIONS: Post-radiation PSA decline rate of ≥ 90% was a prognostic factor for biochemical recurrence in localized prostate cancer patients received 3D-CRT with various durations of ADT.


Assuntos
Antígeno Prostático Específico/sangue , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Radioterapia Conformacional/métodos , Idoso , Antagonistas de Androgênios/uso terapêutico , Estudos de Coortes , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Recidiva Local de Neoplasia/sangue , Recidiva Local de Neoplasia/patologia , Neoplasias da Próstata/metabolismo , Estudos Retrospectivos
3.
J Xray Sci Technol ; 26(3): 473-480, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29562582

RESUMO

PURPOSE: Based on a retrospective analysis, this study aims to develop a simple index for validity of the evaluation point for the dosimetric verification of intensity-modulated radiation therapy (IMRT). METHODS: The results for the dosimetric verifications of a total of 69 IMRT plans were analyzed in this study. A Farmer-type ion chamber was used as a dose detector, and a solid water-equivalent phantom was used. Index values were obtained by dividing the difference between the maximum and minimum dosages by the mean dosage of the 69 plans, and the values were classified into five groups with index value <4, 4-8, 8-12, 12-16, and >16. A t-test was used to assess the statistical significance of the mean differences of the absolute values of the relative errors among these groups. RESULTS: We found that there was no significant difference between the groups with index value <4 and 4-8 (p = 0.152); however, there were significant differences between the other groups (p < 0.01). In addition, when the index values were smaller than 8, the pass ratio of 3% tolerance was 96.2% and the pass ratio of 5% tolerance was 99.9%. We observed that the smaller the index value, the smaller the uncertainty of the dose measurement. CONCLUSIONS: The results obtained in this study may prove to be useful for accurate dosimetric verifications of IMRTs when ion chambers are used.


Assuntos
Dosagem Radioterapêutica/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Humanos , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Cureus ; 15(3): e36743, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37123788

RESUMO

Primary adenoid cystic carcinoma (ACC) of the upper anterior mediastinum is rarely encountered in clinical practice, and no standard treatment has been established. We performed palliative radiotherapy to improve airway narrowing in a patient with primary ACC of the mediastinum who presented with respiratory distress as their main complaint. As a result of radiotherapy, the ACC was reduced in size, the narrowed airway was opened due to compression by the ACC, and the patient's general condition improved. We present the results of this case with a review of the relevant literature.

5.
Cancer Diagn Progn ; 3(1): 61-66, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36632595

RESUMO

BACKGROUND/AIM: In advanced stage lung cancer, bulky tumors can cause serious symptoms such as malignant airway obstruction (MAO). Prompt response to airway obstruction might be essential to improve quality of life and prolong life expectancy. Palliative external beam radiotherapy (EBRT) is a less invasive and highly safe treatment method that can alleviate symptoms and at the same time treat lung cancer. However, there are few reports on the results of palliative radiotherapy performed for improving airway obstruction and obstructive pneumonia. Therefore, this study retrospectively examined the effectiveness of palliative radiotherapy. PATIENTS AND METHODS: We reviewed 38 lung cancer patients with MAO who underwent EBRT. Patients were treated with a median dose of 37.5 Gy (range=30-40 Gy) in 10-20 fractions. Whether a patient was a responder or non-responder was assessed by whether the bronchus that was obstructed before EBRT reopened or improvement of obstructive pneumonia was observed on follow-up chest X-ray or computed tomography after EBRT. RESULTS: The median survival time was 135 days (range=31-469 days) for the responders to EBRT and 45 days (range=23-355 days) for non-responders; this difference was statistically significant (p=0.03). One-year overall survival rate was 18.5% and 0% for the responders to EBRT and non-responders, respectively. CONCLUSION: Palliative EBRT might be an important option for non-curative lung cancer patients with MAO.

6.
Technol Cancer Res Treat ; 21: 15330338221108529, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35770302

RESUMO

Objective: Hippocampus-sparing whole-brain radiotherapy using Halcyon, an instrument dedicated to volumetric modulated arc therapy, has not been studied till date; hence, we aimed to examine whether it can meet the RTOG0933 criteria. Based on this, we compared Halcyon to Tomotherapy, which also uses an O-ring-type linear accelerator. Methods: This exploratory, experimental, and retrospective study used 5 sets of computed tomography images in the head area to investigate the planning target volume, hippocampal doses, and irradiation time. Calculations were performed from 1 to 4 arcs to determine the optimal number of arcs in the Halcyon plan, which were compared to those of Tomotherapy. Results: The Radiation Therapy Oncology Group 0933 criteria could not be satisfied in Halcyon with 1 arc. With 2 arcs, the condition Dmax<16 Gy was not satisfied for 1 case in the hippocampus. Since there were no significant differences between 3 and 4 arcs, including the irradiation time, 3 arcs were considered the best. We compared Halcyon at 3 arcs with tomotherapy and found that tomotherapy was inferior to Halcyon at D98%; however, it was superior to Halcyon in other dose parameters. In contrast, the irradiation time in Halcyon was overwhelmingly superior, with the irradiation time for Halcyon being 1/ninth the time for Tomotherapy. Conclusion: Halcyon was effective in handling hippocampus-sparing whole-brain radiotherapy. We believe that 3-arc radiation is best suited for this procedure. Although Halcyon was inferior to Tomotherapy in terms of dose distribution excluding D98%, it was overwhelmingly superior in terms of irradiation time.


Assuntos
Neoplasias Encefálicas , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Hipocampo/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos
7.
Cureus ; 14(1): e21134, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35186512

RESUMO

Many reports indicate that the prognosis of patients with rectal cancer who have thoracic spine metastases with spinal cord compression is poor. Here, we discuss a case of a patient who achieved an improvement of functional prognosis and long-term survival after undergoing surgery and radiotherapy. We report a case of a 64-year-old female who was found to have metastatic spinal cord compression (MSCC) in the second thoracic vertebra, 10 years after surgery for rectal cancer. She experienced numbness in both legs and had gait difficulties. She underwent posterior decompression surgery and radiotherapy. Her neurological symptoms improved after radiotherapy, and the patient could maintain a standing position without assistance within one week after irradiation. She has since received adjuvant chemotherapy and continues to survive five years six months since MSCC onset.

8.
BMJ Case Rep ; 14(9)2021 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-34548298

RESUMO

In this case report, radiation therapy was performed for bilateral hydronephrosis developed during multiple bone metastases of breast cancer and ileus due to peritoneal dissemination. The patient's preirradiation creatinine level was 8.2 mg/dL, which decreased by the fourth day after starting irradiation therapy. Creatinine level ultimately decreased to 0.6 mg/dL. Pain due to lumbar spine metastasis alleviated and ileus was resolved, allowing the patient to live at home for approximately 5 weeks. The effect of radiotherapy for bilateral hydronephrosis and gastrointestinal obstruction was rapid and good. Palliative radiation treatment can be used for multiple purposes, and in the present patient, we were able to prolong the vital prognosis.


Assuntos
Neoplasias Ósseas , Neoplasias da Mama , Neoplasias Ósseas/radioterapia , Neoplasias da Mama/radioterapia , Feminino , Humanos , Dor , Cuidados Paliativos , Dosagem Radioterapêutica
9.
Cureus ; 13(1): e12612, 2021 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-33585102

RESUMO

Tumor doubling time is an important clinical parameter, but it is rarely reported in cervical cancer. We encountered a case in which the tumor doubling time could be measured using a radiotherapy planning device. A woman in her 40s was diagnosed with cervical cancer stage IB1 (squamous cell carcinoma) and refused treatment. One year and five months later, definitive radiation therapy was administered. Magnetic resonance imaging was performed five times before the start of treatment. When the tumor volume was measured using the radiotherapy planning system - RayStation🄬 (RaySearch Laboratories, Stockholm, Sweden) on the T2 sagittal image, the tumor doubling time was 76 days, and the tumor volume had increased exponentially.

10.
Cureus ; 13(3): e13688, 2021 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-33824832

RESUMO

We present the case of a 78-year-old woman who received definitive radiation therapy for small cell lung cancer three and a half years ago. She was asymptomatic when she tested positive for coronavirus disease 2019 (COVID-19). She then developed a rapid decline in respiratory status on day seven. Chest radiograph revealed a strong shadow at the prior irradiation site. Radiation recall reactions are usually caused by drug administration, but in this case, it was suspected to be caused by COVID-19.

11.
Technol Cancer Res Treat ; 20: 1533033820986824, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33641531

RESUMO

PURPOSE: The aim of this study is to comparatively examine the possibility of reducing the exposure dose to organs at risk, such as the hippocampus and lens, and improving the dose distribution of the planned target volume with and without the use of a head-tilting base plate in hippocampal-sparing whole-brain radiotherapy using tomotherapy. METHODS: Five paired images of planned head computed tomography without and with tilt were analyzed. The hippocampus and planning target volume were contoured according to the RTOG 0933 contouring atlas protocol. The hippocampal zone to be avoided was delineated using a 5-mm margin. The prescribed radiation dose was 30 Gy in 10 fractions. The absorbed dose to planning target volume dose, absorbed dose to the organ at risk, and irradiation time were evaluated. The paired t-test was used to analyze the differences between hippocampal-sparing whole-brain radiotherapy with head tilts and without head tilts. RESULTS: Hippocampal-sparing whole-brain radiotherapy with tilt was not superior in planning target volume doses using the homogeneity index than that without tilt; however, it showed better values, and for Dmean and D2%, the values were closer to 30 Gy. Regarding the hippocampus, dose reduction with tilt was significantly greater at Dmax, Dmean, and Dmin, whereas regarding the lens, it was significantly greater at Dmax and Dmin. The irradiation time was also predominantly shorter. CONCLUSION: In our study, a tilted hippocampal-sparing whole-brain radiotherapy reduced the irradiation time by >10%. Therefore, our study indicated that hippocampal-sparing whole-brain radiotherapy with tomotherapy should be performed with a tilt. The head-tilting technique might be useful during hippocampal-sparing whole-brain radiotherapy. This method could decrease the radiation exposure time, while sparing healthy organs, including the hippocampus and lens.


Assuntos
Neoplasias Encefálicas/radioterapia , Irradiação Craniana/métodos , Decúbito Inclinado com Rebaixamento da Cabeça , Hipocampo/efeitos da radiação , Cristalino/efeitos da radiação , Tratamentos com Preservação do Órgão/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/secundário , Gerenciamento Clínico , Humanos , Imageamento por Ressonância Magnética , Radiometria , Radioterapia Guiada por Imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X
12.
Technol Cancer Res Treat ; 20: 15330338211045497, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34632876

RESUMO

Objectives: Hippocampus-sparing whole-brain radiotherapy (HS-WBRT) using tomotherapy is known to provide a better dose distribution than volumetric-modulated arc therapy but requires an extended irradiation time. The present study aimed to investigate whether irradiation time can be shortened by reducing the modulation factor (MF) without losing the target dose distribution. Methods: Using six tilted computed tomography images in the head area, the planning target volume (PTV) and hippocampal doses, and the irradiation time was investigated with a jaw width of 1 cm, a pitch of 0.200, and the MF changed from 3.0 to 2.6, 2.2, 1.8, and 1.4. Results: No significant changes in the PTV or hippocampus were found with MF in the range from 3.0 to 1.8, but marked deterioration was found with that of 1.4. The irradiation time showed a linear relationship with the MF within the range from 3.0 to 1.8, with 1334, 1158, 986, and 817 s at modulation factors of 3.0, 2.6, 2.2, and 1.8, respectively. However, when the MF was 1.4, the irradiation time was 808 s. Conclusions: When HS-WBRT is performed with a tilted body position and a jaw width of 1 cm, with a MF of 1.8, a favorable balance between dose parameters and irradiation time is achieved, whereas with a MF of 1.4, the quality of the radiotherapy plan deteriorates, and the irradiation time is approximately the same as that with a MF of 1.8.


Assuntos
Neoplasias Encefálicas/radioterapia , Irradiação Craniana , Hipocampo , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/prevenção & controle , Neoplasias Encefálicas/secundário , Hipocampo/diagnóstico por imagem , Hipocampo/lesões , Humanos , Tratamentos com Preservação do Órgão/métodos , Posicionamento do Paciente , Doses de Radiação , Lesões por Radiação/prevenção & controle , Fatores de Tempo , Tomografia Computadorizada por Raios X
13.
Sci Rep ; 11(1): 6476, 2021 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-33742050

RESUMO

The aim of this study was to review our initial experience of using radium 223 (Ra-223) for metastatic castration-resistant prostate cancer (CRPC) and to evaluate whether pretreatment PSA levels correlate with completion of Ra-223 treatment. In addition, we examined change ratios of PSA, ALP and BAP after the third administration to evaluate the correlation of these change ratios with completion of the subsequent Ra-223 treatment. Forty patients were enrolled in this retrospective study. Ra-223 treatment was considered completed in patients who received five or six administrations. Patient backgrounds and changes in biomarkers were compared between patient groups (complete vs. incomplete Ra-223 treatment). PSA levels before treatment were significantly lower in the complete compared with the incomplete group (cutoff value; 21.7). ALP and BAP levels had decreased after the third administration in the complete group, compared with baseline levels, while levels in the incomplete group had increased. Significant difference was seen in ALP levels, while was not seen in BAP levels between the two groups. Ra-223 treatment should be considered for CRPC with low PSA levels. Changes in PSA and ALP during Ra-223 treatment might provide markers to identify patients likely to complete Ra-223 treatment, with implications for prognosis.


Assuntos
Antígeno Prostático Específico/sangue , Neoplasias da Próstata/radioterapia , Idoso , Idoso de 80 Anos ou mais , Fosfatase Alcalina/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/sangue , Rádio (Elemento)/uso terapêutico , Resultado do Tratamento
14.
Cureus ; 13(9): e17743, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34659956

RESUMO

Aim To investigate the variation of tumor volume during moderate hypo-fractionated stereotactic body radiation therapy (SBRT). Patients and Methods Twenty patients, who received SBRT at our institution, were included in the analysis. A prescribed dose was 56 Gy at iso-center in seven fractions. Tumor volumes before and during SBRT were calculated. In order to investigate factors affecting the variation of tumor volume in RT 2 (after first irradiation) and RT 7 (after last irradiation), various parameters were verified by the Mann-Whitney U test. Results With regard to the low maximum standardized uptake values (SUVmax) group, transient increase of tumor volume was found in RT 2, and tumor volume reduction was hardly found in RT 7. With regard to the high SUVmax group, a transient increase was not found, and a definite reduction was found in the treatment course. Conclusion Accurate prediction of tumor volume variation is required for more accurate treatment, such as adaptive radiation therapy.

15.
Cancer Diagn Progn ; 1(3): 193-200, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35399314

RESUMO

Background/Aim: The most severe adverse event of radiotherapy in lung cancer is radiation pneumonitis (RP). Some indices commonly used to prevent RP are evaluated based on the anatomical lung volume. The irradiation dose may be more accurately assessed by using functional lung volume. We evaluated the usefulness of computed tomography (CT) incorporating functional ventilation images acquired by the inhalation of xenon (Xe) gas (Xe-CT functional images). Patients and Methods: Two plans were created for twelve patients: volumetric modulated arc therapy (VMAT) planning using conventional chest CT images (anatomical plans) and VMAT planning using Xe-CT functional images (functional plans), and the dosimetric parameters were compared. Results: Compared to the anatomical plans, the functional plans had significantly reduced V 20Gy in the high-functional lungs (p=0.005), but significant differences were not seen in the moderate-functional and low-functional lungs. Conclusion: The incorporation of Xe-CT functional images into VMAT plans enables radiotherapy planning with consideration of lung function.

16.
Australas Phys Eng Sci Med ; 41(4): 1069-1074, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30361917

RESUMO

The objective of this study was to clarify the usefuleness of the K parameters of the independent verification method using V100% (the volume of water receiving 100% of the prescription dose) for institutions implementing the high-dose-rate (HDR) intracavitary brachytherapy for gynecological cancer. The data of 249 plans of 11 institutions in Japan were used, and the constant K value obtained by a parameter fit for single-192Ir, two-192Ir, and three-192Ir systems was calculated. The predicted total dwell time calculated using the constant K value was defined as Tpr, and the total dwell time calculated using a radiation treatment planning system was defined as TRTP. The ratio of Tpr and TRTP for each plan was calculated. The constant K values (95% CI) obtained for each system outlined above were 1233 (1227-1240), 1205 (1199-1211), and 1171 (1167-1175), respectively. Regarding the Tpr/TRTP, the entire data were within 0.9-1.1. For accurate verification, it was clarified that constant K values should be calculated for each system. The Nuclear Regulatory Commission considers a difference of 20% between the prescribed total dose and the administered total dose as a reportable medical event. There is a need for a quick method to verify the accuracy with a minimum of 10% threshold of a plan. The constant K values in this study were obtained from multiple institutions, and the variation in the values among these institutions was small. The data obtained by this study may be used as a parameter of this verification method employed by numerous institutions, particularly those who have recently initiated HDR brachytherapy. In addition, for institutions already using this method, this data might be useful for the validation of the parameters which were used in such institutions.


Assuntos
Braquiterapia/métodos , Neoplasias dos Genitais Femininos/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Humanos , Medicina de Precisão/métodos , Garantia da Qualidade dos Cuidados de Saúde , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA