Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Can Vet J ; 61(6): 584-588, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32675809

RESUMO

A 3-year-old intact female Labradoodle bitch was referred due to fever and lethargy 4 days postpartum. The dog was reported to have had prolonged labor that required assistance and fetal membranes were retained. Physical examination and diagnostics led to a suspicion of metritis and uterine perforation. Ovariohysterectomy was performed. Gross and histopathology findings revealed multifocal uterine perforation, necrosuppurative metritis, and placenta percreta. Post-operative antibiotic therapy and supportive care resulted in an uneventful clinical recovery. This is the first reported case of placenta percreta in a bitch. It is presumed that this pathology was paramount in the patient's development of metritis and subsequent uterine rupture. Key clinical message: Placenta percreta may lead to more severe clinical consequences of metritis, including uterine rupture.


Perforation utérine secondaire à une métrite et un placenta percreta chez une chienne en période post-partum. Une femelle Labradoodle intacte âgée de 3 ans fut référée pour cause de fièvre et léthargie 4 jours post-partum. Il fut rapporté que la chienne avait eu un travail long qui demanda de l'assistance et qu'il y avait eu rétention des membranes foetales. L'examen physique et le diagnostic mena à un doute de métrite et de perforation utérine. Une ovario-hystérectomie fut réalisée. Les trouvailles de pathologie macroscopique et d'histopathologie révélèrent des perforations utérines multifocales, une métrite nécro-suppurative et un placenta percreta. Une antibiothérapie post-opératoire et des soins de support ont résulté en une guérison clinique sans conséquence. Ceci représente le premier cas rapporté de placenta percreta chez une chienne. Il est présumé que chez cette chienne cette pathologie était vitale dans le développement de la métrite et de la rupture utérine subséquente.Message clinique clé :Un placenta percreta peut mener à des conséquences cliniques plus sévères de métrite, incluant la rupture utérine.(Traduit par Dr Serge Messier).


Assuntos
Doenças do Cão , Placenta Acreta , Perfuração Uterina , Ruptura Uterina , Animais , Doenças do Cão/tratamento farmacológico , Doenças do Cão/etiologia , Cães , Feminino , Histerectomia/veterinária , Placenta Acreta/cirurgia , Placenta Acreta/veterinária , Período Pós-Parto , Gravidez , Perfuração Uterina/veterinária , Ruptura Uterina/veterinária
2.
Vet Surg ; 45(3): 347-55, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27007191

RESUMO

OBJECTIVE: To determine the effects of the Proximal Abducting Ulnar Osteotomy (PAUL) on contact pressures of congruent and incongruent (short radius) canine elbows. STUDY DESIGN: Ex vivo biomechanical study. SAMPLE POPULATION: Unpaired normal cadaveric canine forelimbs (n=16). METHODS: A servohydraulic testing frame and thin-film sensors were utilized to measure intra-articular contact area (CA), mean contact pressure (mCP), and peak contact pressure (pCP) for medial and lateral elbow compartments. Percent contribution of the medial compartment relative to the whole (%Med) was also examined. Baseline data were collected in 9 congruent elbows and 7 incongruent elbows where the radius was shortened. Both sets of elbows were tested following ulnar osteotomy and sequential placement of 2 and 3 mm PAUL plates and paw repositioning (to account for any medial to lateral shift of transarticular forces). Paired t-tests compared sequential procedural steps. P<.05 was significant. RESULTS: For congruent elbows, the 2 mm PAUL plate decreased CA in both compartments compared to baseline; lateral pCP increased with subsequent paw repositioning. Induction of radio-ulnar incongruity decreased CA and increased mCP medially, decreased pCP laterally, and increased %MedCA and %MedmCP compared to baseline. Both PAUL plates decreased mCP and pCP medially, with no effect laterally. Paw repositioning had no effect. CONCLUSION: The PAUL procedure had no effect on medial compartment pressure in the congruent elbow. It may ameliorate increased medial compartment pressure in the incongruent elbow. This change does not result from a medial to lateral compartmental shift and deserves further investigation.


Assuntos
Placas Ósseas/veterinária , Doenças do Cão/cirurgia , Articulação do Cotovelo/fisiologia , Deformidades Congênitas das Extremidades Superiores/veterinária , Animais , Fenômenos Biomecânicos , Cadáver , Cães/fisiologia , Membro Anterior/fisiologia , Osteotomia/veterinária , Pressão , Amplitude de Movimento Articular , Deformidades Congênitas das Extremidades Superiores/cirurgia
3.
Vet Comp Orthop Traumatol ; 35(1): 1-9, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34547789

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of stem positioning on the biomechanical performance of a novel, collared, short-stem total hip implant under compression and torsion ex vivo. STUDY DESIGN: Six canine cadaveric femurs were implanted with a collared short-stem femoral implant. Canal flare index (CFI), stem angle, absolute and relative cut heights and relative size were measured radiographically and used as independent variables. Biomechanical performance of the construct was evaluated using physiologic loading (loading) and supraphysiologic loading (failure) protocols. RESULTS: During loading protocols, compressive stiffness was influenced by absolute cut height (p = 0.018). During failure protocols, peak torque was influenced by CFI (p = 0.004) and craniocaudal relative size (p = 0.005). Peak load and torsional stiffness were not impacted by any of the radiographic variables (p > 0.05). Three of six femurs developed longitudinal fractures originating at the medial calcar at the time of failure. CONCLUSION: The biomechanical performance of the collared short-stem implant was positively impacted by preserving more of the femoral neck, having a higher CFI and using a smaller implant size relative to the femoral neck isthmus.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Animais , Artroplastia de Quadril/veterinária , Fenômenos Biomecânicos , Cães , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Colo do Fêmur , Prótese de Quadril/veterinária , Desenho de Prótese/veterinária , Torque
4.
Vet Comp Orthop Traumatol ; 33(6): 417-427, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32971544

RESUMO

OBJECTIVE: The aim of this study was to evaluate the relationship between radiographic fit/fill measurements and biomechanical performance of three canine cementless total hip implant designs using an in vitro biomechanical testing protocol that replicates compression and torsion. STUDY DESIGN: Eighteen (six/group) canine cadaveric femurs were implanted with one of three cementless total hip implant designs: (1) collarless, (2) collared or (3) lateral bolt stems. Femoral length, canal flare index (CFI), canal fill, stem fit, stem level and stem angle were measured as independent variables. Biomechanical performance was tested using physiological, non-destructive gait loading (loading protocols) and destructive testing (failure protocols). RESULTS: During loading protocols, compressive stiffness was influenced by stem level (p < 0.05) and torsional stiffness was influenced by stem level and CFI for collarless stems (p < 0.05). During failure protocols, peak load was influenced by mediolateral (ML) stem angle (p < 0.05) and CFI (p < 0.01) for collarless stems and CFI for lateral bolt stems (p < 0.05). Peak torque was influenced by ML stem angle, craniocaudal stem angle and CFI for collarless stems (p < 0.05) and average ML fill for collared stems (p < 0.05). CONCLUSION: Biomechanical performance of collarless stems in cementless hip arthroplasty is more impacted by radiographic fit/fill than lateral bolt and collared stems. As a result, collarless stems may be more dependent on preoperative fit and intraoperative precision.


Assuntos
Artroplastia de Quadril/veterinária , Cães/cirurgia , Animais , Fenômenos Biomecânicos , Próteses e Implantes/veterinária , Radiografia/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA