Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Kidney Dis ; 74(5): 610-619, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31375298

RESUMO

RATIONALE & OBJECTIVE: Contaminated water and other fluids are increasingly recognized to be associated with health care-associated infections. We investigated an outbreak of Gram-negative bloodstream infections at 3 outpatient hemodialysis facilities. STUDY DESIGN: Matched case-control investigations. SETTING & PARTICIPANTS: Patients who received hemodialysis at Facility A, B, or C from July 2015 to November 2016. EXPOSURES: Infection control practices, sources of water, dialyzer reuse, injection medication handling, dialysis circuit priming, water and dialysate test findings, environmental reservoirs such as wall boxes, vascular access care practices, pulsed-field gel electrophoresis, and whole-genome sequencing of bacterial isolates. OUTCOMES: Cases were defined by a positive blood culture for any Gram-negative bacteria drawn July 1, 2015 to November 30, 2016 from a patient who had received hemodialysis at Facility A, B, or C. ANALYTICAL APPROACH: Exposures in cases and controls were compared using matched univariate conditional logistic regression. RESULTS: 58 cases of Gram-negative bloodstream infection occurred; 48 (83%) required hospitalization. The predominant organisms were Serratia marcescens (n=21) and Pseudomonas aeruginosa (n=12). Compared with controls, cases had higher odds of using a central venous catheter for dialysis (matched odds ratio, 54.32; lower bound of the 95% CI, 12.19). Facility staff reported pooling and regurgitation of waste fluid at recessed wall boxes that house connections for dialysate components and the effluent drain within dialysis treatment stations. Environmental samples yielded S marcescens and P aeruginosa from wall boxes. S marcescens isolated from wall boxes and case-patients from the same facilities were closely related by pulsed-field gel electrophoresis and whole-genome sequencing. We identified opportunities for health care workers' hands to contaminate central venous catheters with contaminated fluid from the wall boxes. LIMITATIONS: Limited patient isolates for testing, on-site investigation occurred after peak of infections. CONCLUSIONS: This large outbreak was linked to wall boxes, a previously undescribed source of contaminated fluid and biofilms in the immediate patient care environment.


Assuntos
Bacteriemia/epidemiologia , Infecção Hospitalar/epidemiologia , Surtos de Doenças/estatística & dados numéricos , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/epidemiologia , Diálise Renal/efeitos adversos , Idoso , Bacteriemia/microbiologia , Feminino , Seguimentos , Infecções por Bactérias Gram-Negativas/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Estudos Retrospectivos , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA