Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 126(15): 155001, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33929259

RESUMO

Fast-ion driven Alfvén waves with frequency close to the ion cyclotron frequency (f=0.58f_{ci}) excited by energetic ions from a neutral beam are stabilized via a controlled energetic ion density ramp for the first time in a fusion research plasma. The scaling of wave amplitude with injection rate is consistent with theory for single mode collisional saturation near marginal stability. The wave is identified as a shear-polarized global Alfvén eigenmode excited by Doppler-shifted cyclotron resonance with fast ions with sub-Alfvénic energetic ions, a first in fusion research plasmas.

2.
Phys Rev Lett ; 127(2): 025001, 2021 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-34296897

RESUMO

A thermal ion driven bursting instability with rapid frequency chirping, considered as an Alfvénic ion temperature gradient mode, has been observed in plasmas having reactor-relevant temperature in the DIII-D tokamak. The modes are excited over a wide spatial range from macroscopic device size to microturbulence size and the perturbation energy propagates across multiple spatial scales. The radial mode structure is able to expand from local to global in ∼0.1 ms and it causes magnetic topology changes in the plasma edge, which can lead to a minor disruption event. Since the mode is typically observed in the high ion temperature ≳10 keV and high-ß plasma regime, the manifestation of the mode in future reactors should be studied with development of mitigation strategies, if needed. This is the first observation of destabilization of the Alfvén continuum caused by the compressibility of ions with reactor-relevant ion temperature.

3.
Phys Rev Lett ; 127(23): 235002, 2021 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-34936805

RESUMO

Fast ion phase-space flow, driven by Alfvén eigenmodes (AEs), is measured by an imaging neutral particle analyzer in the DIII-D tokamak. The flow firstly appears near the minimum safety factor at the injection energy of neutral beams, and then moves radially inward and outward by gaining and losing energy, respectively. The flow trajectories in phase space align well with the intersection lines of the constant magnetic moment surfaces and constant E-(ω/n)P_{ζ} surfaces, where E, P_{ζ} are the energy and canonical toroidal momentum of ions; ω and n are angular frequencies and toroidal mode numbers of AEs. It is found that the flow is so destructive that the thermalization of fast ions is no longer observed in regions of strong interaction. The measured phase-space flow is consistent with nonlinear hybrid kinetic-magnetohydrodynamics simulation. Calculations of the relatively narrow phase-space islands reveal that fast ions must transition between different flow trajectories to experience large-scale phase-space transport.

4.
Phys Rev Lett ; 120(15): 155002, 2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29756886

RESUMO

DIII-D experiments at low density (n_{e}∼10^{19} m^{-3}) have directly measured whistler waves in the 100-200 MHz range excited by multi-MeV runaway electrons. Whistler activity is correlated with runaway intensity (hard x-ray emission level), occurs in novel discrete frequency bands, and exhibits nonlinear limit-cycle-like behavior. The measured frequencies scale with the magnetic field strength and electron density as expected from the whistler dispersion relation. The modes are stabilized with increasing magnetic field, which is consistent with wave-particle resonance mechanisms. The mode amplitudes show intermittent time variations correlated with changes in the electron cyclotron emission that follow predator-prey cycles. These can be interpreted as wave-induced pitch angle scattering of moderate energy runaways. The tokamak runaway-whistler mechanisms have parallels to whistler phenomena in ionospheric plasmas. The observations also open new directions for the modeling and active control of runaway electrons in tokamaks.

5.
Phys Rev Lett ; 116(9): 095001, 2016 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-26991180

RESUMO

Experiments in the DIII-D tokamak show that fast-ion transport suddenly becomes stiff above a critical threshold in the presence of many overlapping small-amplitude Alfvén eigenmodes (AEs). The threshold is phase-space dependent and occurs when particle orbits become stochastic due to resonances with AEs. Above threshold, equilibrium fast-ion density profiles are unchanged despite increased drive, and intermittent fast-ion losses are observed. Fast-ion Dα spectroscopy indicates radially localized transport of the copassing population at radii that correspond to the location of midcore AEs. The observation of stiff fast-ion transport suggests that reduced models can be used to effectively predict alpha profiles, beam ion profiles, and losses to aid in the design of optimized scenarios for future burning plasma devices.

6.
Phys Rev Lett ; 110(6): 065004, 2013 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-23432263

RESUMO

We report the first observation of prompt neutral beam-ion losses due to nonresonant scattering induced by toroidal and reversed shear Alfvén eigenmodes in the DIII-D tokamak. The coherent losses are of full energy beam ions expelled from the plasma on their first poloidal orbit. The first-orbit loss mechanism causes enhanced, concentrated losses on the first wall exceeding nominal levels of prompt losses. The loss amplitude scales linearly with the mode amplitude. The data provide a novel and direct measure of the radial excursion or scatter of particles induced by individual modes and may shed light on the mechanism for the scattering of energetic particles in interstellar medium.

7.
Phys Rev Lett ; 109(3): 035003, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22861863

RESUMO

From numerical simulation and analytical modeling it is shown that fast ions can resonate with plasma waves at fractional values of the particle drift-orbit transit frequency when the plasma wave amplitude is sufficiently large. The fractional resonances, which are caused by a nonlinear interaction between the particle orbit and the wave, give rise to an increased density of resonances in phase space which reduces the threshold for stochastic transport. The effects of the fractional resonances on spatial and energy transport are illustrated for an energetic particle geodesic acoustic mode but they apply equally well to other types of MHD activity.

8.
Phys Rev Lett ; 106(7): 075003, 2011 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-21405522

RESUMO

Two-dimensional images of electron temperature perturbations are obtained with electron cyclotron emission imaging (ECEI) on the DIII-D tokamak and compared to Alfvén eigenmode structures obtained by numerical modeling using both ideal MHD and hybrid MHD-gyrofluid codes. While many features of the observations are found to be in excellent agreement with simulations using an ideal MHD code (NOVA), other characteristics distinctly reveal the influence of fast ions on the mode structures. These features are found to be well described by the nonperturbative hybrid MHD-gyrofluid model TAEFL.

9.
Rev Sci Instrum ; 92(4): 043535, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243455

RESUMO

Radially resolved hydrogenic isotope fraction measurement capabilities have been developed for DIII-D using the main-ion charge exchange recombination (MICER) spectroscopy system in preparation for mixed hydrogen and deuterium experiments. Constraints on the hydrogenic ion temperatures and velocities based on measurements of the impurity ion properties are required to accurately fit the spectrum. Corrections for cross sectional distortions, spatial smearing due to the halo, and a neoclassical offset between the impurity and hydrogenic toroidal rotation are applied to the constraints prior to fitting the MICER spectrum. Extensive atomic physics calculations have been performed using the FIDASIM code, which has recently been improved to allow simulations using mixtures of hydrogenic species. These results demonstrate that for the same plasma parameters, the Dα emission is 20%-30% brighter than Hα due to differences in rate coefficients associated with the different ion thermal velocities for the same temperature and therefore must be taken into consideration when calculating absolute densities. However, despite these differences, the absolute error when estimating the hydrogen isotope fraction [nH/(nH + nD)] by using the Hα radiance fraction [LHα/(LHα + LDα)] is typically less than 5% due to the way the fraction is formed, making the radiance fraction a reasonably accurate estimate of the isotope fraction for most cases.

10.
Rev Sci Instrum ; 92(3): 033533, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33819993

RESUMO

An Imaging Fast Ion D-alpha (IFIDA) diagnostic, characterized by a high optical spatial resolution of ≤2 mm for accurate validation of energetic particle (EP) transport models, has been developed on DIII-D. The diagnostic provides a 2D image in the radial-poloidal plane of the FIDA signal generated by EP emission after charge exchange with an injected neutral beam. A narrow passband filter integrates the FIDA signal in the spectral region of 650-652 nm (blue-shifted FIDA tail), which is mostly generated by co-passing EPs of energies E ≃ 40-80 keV. A beam modulation technique is employed to estimate the active component of the signal, which is then used to compute EP profiles and gradients with a higher accuracy than the standard spectroscopic FIDA diagnostic. The current diagnostic time resolution is ≃3 ms. In this work, the IFIDA diagnostic design is explained and data are compared with the spectroscopic FIDA diagnostic, which shares the same viewing geometry, to assess the improvements in EP profile reconstruction.

11.
Rev Sci Instrum ; 92(4): 043554, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243403

RESUMO

An Imaging Neutral Particle Analyzer (INPA) diagnostic has been designed for the ASDEX Upgrade (AUG) tokamak. The AUG INPA diagnostic will measure fast neutrals escaping the plasma after charge exchange reactions. The neutrals will be ionized by a 20 nm carbon foil and deflected toward a scintillator by the local magnetic field. The use of a neutral beam injector (NBI) as an active source of neutrals will provide radially resolved measurements, while the use of a scintillator as an active component will allow us to cover the whole plasma along the NBI line with unprecedented phase-space resolution (<12 keV and 8 cm) and a fast temporal response (up to 1 kHz with the high resolution acquisition system and above 100 kHz with the low resolution one), making it suitable to study localized fast-ion redistributions in phase space.

12.
Phys Rev Lett ; 103(17): 175001, 2009 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-19905765

RESUMO

Cross-field diffusion of energetic ions by microturbulence is measured during neutral-beam injection into the DIII-D tokamak. Fast-ion D(alpha), neutron, and motional Stark effect measurements diagnose the fast-ion distribution function. As expected for transport by plasma turbulence, anomalies relative to the classical prediction are greatest in high temperature plasmas, at low fast-ion energy, and at larger minor radius. Theoretical estimates of fast-ion diffusion are comparable to experimental levels.

13.
Rev Sci Instrum ; 89(10): 10B106, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399846

RESUMO

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 µm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm-1 < |k R | ≤ 25 cm-1) fluctuations with sensitivity 3 × 1 0 13 m - 2 / kHz , while the interferometer simultaneously measures low-k (|k R | < 5 cm-1) fluctuations with sensitivity 3 × 1 0 14 m - 2 / kHz . The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ∼ T i regime. Furthermore, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

14.
Rev Sci Instrum ; 89(10): 10B105, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399752

RESUMO

In order to improve both the density and particularly the temporal resolution beyond previous dispersion interferometers (DIs), a heterodyne technique based on an acousto-optic (AO) cell has been added to the DI. A 40 MHz drive frequency for the AO cell allows density fluctuation measurements into the MHz range. A CO2 laser-based heterodyne DI (HDI) installed on DIII-D has demonstrated that the HDI is capable of tracking the density evolution throughout DIII-D discharges, including disruption events and other rapid transient phenomena. The data also show good agreement with independent density measurements obtained with the existing DIII-D two-color interferometer. The HDI line-integrated density resolution sampled over a 1 s interval is ∼9 × 1017 m-2. Density fluctuations induced by MHD instabilities are also successfully measured by the HDI.

15.
Rev Sci Instrum ; 89(10): 10B102, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399936

RESUMO

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 µm and 5.22 µm using a CO2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 µm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. The corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 1018 m-2, and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 1019 Tm-2. Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

16.
Rev Sci Instrum ; 87(11): 11E117, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910387

RESUMO

Heterodyne interferometry and phase contrast imaging (PCI) are robust, mature techniques for measuring low-k and high-k electron density fluctuations, respectively. This work describes the first-ever implementation of a combined PCI-interferometer. The combined system uses a single 10.6 µm probe beam, two interference schemes, and two detectors to measure electron density fluctuations at large spatiotemporal bandwidth (10 kHz

17.
Rev Sci Instrum ; 87(4): 043507, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131674

RESUMO

A gamma ray camera is built for the DIII-D tokamak [J. Luxon, Nucl. Fusion 42, 614 (2002)] that provides spatial localization and energy resolution of gamma flux by combining a lead pinhole camera with custom-built detectors and optimized viewing geometry. This diagnostic system is installed on the outer midplane of the tokamak such that its 123 collimated sightlines extend across the tokamak radius while also covering most of the vertical extent of the plasma volume. A set of 30 bismuth germanate detectors can be secured in any of the available sightlines, allowing for customizable coverage in experiments with runaway electrons in the energy range of 1-60 MeV. Commissioning of the gamma ray imager includes the quantification of electromagnetic noise sources in the tokamak machine hall and a measurement of the energy spectrum of background gamma radiation. First measurements of gamma rays coming from the plasma provide a suitable testbed for implementing pulse height analysis that provides the energy of detected gamma photons.

19.
Rev Sci Instrum ; 87(12): 123502, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28040946

RESUMO

A heterodyne detection scheme is combined with a 10.59 µm CO2 laser dispersion interferometer for the first time to allow large bandwidth measurements in the 10-100 MHz range. The approach employed utilizes a 40 MHz acousto-optic cell operating on the frequency doubled CO2 beam which is obtained using a high 2nd harmonic conversion efficiency orientation patterned gallium arsenide crystal. The measured standard deviation of the line integrated electron density equivalent phase resolution obtained with digital phase demodulation technique, is 4 × 1017 m-2. Air flow was found to significantly affect the baseline of the phase signal, which an optical table cover was able to reduce considerably. The heterodyne dispersion interferometer (DI) approach is found to be robustly insensitive to motion, with measured phase shifts below baseline drifts even in the presence of several centimeters of retroreflector induced path length variations. Plasma induced dispersion was simulated with a wedged ZnSe plate and the measured DI phase shifts are consistent with expectations.

20.
Rev Sci Instrum ; 85(11): 11D841, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430254

RESUMO

New phase space mapping and uncertainty analysis of energetic ion loss data in the DIII-D tokamak provides experimental results that serve as valuable constraints in first-principles simulations of energetic ion transport. Beam ion losses are measured by the fast ion loss detector (FILD) diagnostic system consisting of two magnetic spectrometers placed independently along the outer wall. Monte Carlo simulations of mono-energetic and single-pitch ions reaching the FILDs are used to determine the expected uncertainty in the measurements. Modeling shows that the variation in gyrophase of 80 keV beam ions at the FILD aperture can produce an apparent measured energy signature spanning across 50-140 keV. These calculations compare favorably with experiments in which neutral beam prompt loss provides a well known energy and pitch distribution.