RESUMO
OBJECTIVE: Helical stents have been developed to treat peripheral arterial disease (PAD) in the superficial femoral artery (SFA), with the premise that their particular geometry could promote swirling flow in the blood. The aim of this work is to provide evidence on the existence of this swirling flow by quantifying its signatures. MATERIALS AND METHODS: This study consists of in vitro and in vivo parts. For the in vitro part, 3 helical stent models of different helicity degrees and 1 straight model were fabricated, and the flow was assessed at the inlet and outlet of each model. For the in vivo part, only 1 patient, treated with the helical stent, was eligible to participate in the study. The stent implanted in the SFA of the patient was evaluated in 2 leg postures (straight and flexed), and flow was assessed in 12 locations along the SFA. The in vivo study was approved by an ethical board (NL80130.091.21) in the Netherlands. High-frame-rate ultrasound was used to acquire data from the regions of interest (ROIs), using microbubbles as contrast agents. After processing the data via a correlation-based algorithm (echo particle image velocimetry or echoPIV), the velocity vector field within each ROI was extracted and analyzed for parameters such as vector complexity and velocity profile skewedness. RESULTS: The results show that in the outlet of the helical stents, when compared with the inlet, the flow vector field is more complex and the velocity profile is more skewed. For the in vivo case, the outcomes demonstrate more complexity and higher variability in the sign of skewedness inside the stent when compared with the flow in the proximal to the stent. CONCLUSIONS: Helical stents make the vector field of the flow more complex and the velocity profile more skewed, both of which are signatures of swirling flow. Further studies are needed to evaluate whether these features can benefit patients in terms of patency rates. CLINICAL IMPACT: This study demonstrates that helical stent models alter the blood flow when compared with straight stent models. Particularly, the flow grows more complex and its velocity profile becomes more skewed, both of which hint at the existence of swirling flow inside the helical stent. These observations, alongside with population-based studies that are currently being carried out, may provide the evidence that helical stents have some advantages over straight stents for the patients.
RESUMO
PURPOSE: Contemporary diagnostic modalities, including contrast-enhanced computed tomography (CTA) and duplex ultrasound, have been insufficiently able to predict endograft thrombosis. This study introduces an implementation of image-based computational fluid dynamics (CFD), by exemplification with 4 patients treated with an endograft for occlusive disease of the superficial femoral artery (SFA). The potential of personalized CFD for predicting endograft thrombosis is investigated. MATERIALS AND METHODS: Four patients treated with endografts for an occluded SFA were retrospectively included. CFD simulations, based on CTA and duplex ultrasound, were compared for patients with and without endograft thrombosis to investigate potential flow-related causes of endograft thrombosis. Time-averaged wall shear stress (TAWSS) was computed, which highlights areas of prolonged residence times of coagulation factors in the graft. RESULTS: CFD simulations demonstrated normal TAWSS (>0.4 Pa) in the SFA for cases 1 and 2, but low levels of TAWSS (<0.4 Pa) in cases 3 and 4, respectively. Primary patency was achieved in cases 1 and 2 for over 2 year follow-up. Cases 3 and 4 were complicated by recurrent endograft thrombosis. CONCLUSION: The presence of a low TAWSS was associated with recurrent endograft thrombosis in subjects with otherwise normal anatomic and ultrasound assessment and a good distal run-off.
Assuntos
Implante de Prótese Vascular , Trombose , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hidrodinâmica , Estudos Retrospectivos , Resultado do Tratamento , Trombose/diagnóstico por imagem , Trombose/etiologia , Hemodinâmica , Modelos CardiovascularesRESUMO
PURPOSE: To identify potential hemodynamic predictors for limb thrombosis (LT) following endovascular aneurysm repair with the Anaconda endograft in a patient-specific phantom. MATERIALS AND METHODS: A thin-walled flow phantom, based on a patient's aortic anatomy and treated with an Anaconda endograft, that presented with a left-sided LT was fabricated. Contrast-enhanced ultrasound particle image velocimetry was performed to quantify time-resolved velocity fields. Measurements were performed in the same phantom with and without the Anaconda endograft, to investigate the impact of the endograft on the local flow fields. Hemodynamic parameters, namely vector complexity (VC) and residence time (RT), were calculated for both iliac arteries. RESULTS: In both limbs, the vector fields were mostly unidirectional during the peak systolic and end-systolic velocity phases before and after endograft placement. Local vortical structures and complex flow fields were observed at the diastolic and transitional flow phases. The average VC was higher (0.11) in the phantom with endograft, compared to the phantom without endograft (0.05). Notably, in both left and right iliac arteries, the anterior wall regions corresponded to a 2- and 4-fold increase in VC in the phantom with endograft, respectively. RT simulations showed values of 1.3 to 6 seconds in the phantom without endograft. A higher RT (up to 25 seconds) was observed in the phantom with endograft, in which the left iliac artery, with LT in follow-up, showed 2 fluid stasis regions. CONCLUSION: This in vitro study shows that unfavorable hemodynamics were present mostly in the limb that thrombosed during follow-up, with the highest VC and longest RT. These parameters might be valuable in predicting the occurrence of LT in the future. CLINICAL IMPACT: This in-vitro study aimed to identify potential hemodynamic predictors for limb thrombosis following EVAR using ultrasound particle image velocimetry (echoPIV) technique. It was shown that unfavorable hemodynamic norms were present mostly in the thrombosed limb. Owing to the in-vivo feasibility of the echoPIV, future efforts should focus on the evaluation of these hemodynamic norms in clinical trials. Thereafter, using echoPIV as a bedside technique in hospitals becomes more promising. Performing echoPIV in pre-op phase may provide valuable insights for surgeons to enhance treatment planning. EchoPIV is also applicable for follow-up sessions to evaluate treatment progress and avoid/predict complications.
RESUMO
PURPOSE: To evaluate the impact of elective endovascular aneurysm repair (EVAR) on the carotid-femoral pulse wave velocity (cfPWV) and central pressure waveform, through 1-year follow-up. MATERIALS AND METHODS: A tonometric device was used to measure cfPWV and estimate the central pressure waveform in 20 patients with an infrarenal abdominal aortic aneurysm scheduled for elective EVAR. The evaluated central hemodynamic parameters included the central pressures, the augmentation index (AIx), and the subendocardial viability ratio (SEVR). AIx quantifies the contribution of reflected wave to the central systolic pressure, whereas SEVR describes the myocardial perfusion relative to the cardiac workload. Measurements were performed before EVAR, at discharge, and 6 weeks and 1 year after EVAR. RESULTS: CfPWV was increased at discharge (12.4±0.4 vs 11.3±0.5 m/s at baseline; p=0.005) and remained elevated over the course of 1-year follow-up (6 weeks: cfPWV = 12.2±0.5 m/s; 1 year: cfPWV = 12.2±0.7 m/s, p<0.05). After an initial drop in systolic central pressure at discharge, all the central pressures increased thereafter up to 1 year, without significant differences compared with baseline. The same was observed for the AIx and SEVR. CONCLUSION: Endovascular aortic aneurysm repair caused an increase in pulse wave velocity compared with baseline, which remained elevated through 1 year follow-up, which may be related to an increased cardiovascular risk. However, no differences in central pressure, augmentation index, and subendocardial viability ration were observed during follow-up.
Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Rigidez Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Pressão Sanguínea , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Análise de Onda de Pulso , Resultado do TratamentoRESUMO
PURPOSE: To compare the flow patterns and hemodynamics of the AFX stent-graft and the covered endovascular reconstruction of aortic bifurcation (CERAB) configuration using laser particle image velocimetry (PIV) experiments. MATERIALS AND METHODS: Two anatomically realistic aortoiliac phantoms were constructed using polydimethylsiloxane polymer. An AFX stent-graft with a transparent cover made with a new method was inserted into one phantom. A CERAB configuration using Atrium's Avanta V12 with transparent covers made with a previously established method was inserted into the other phantom, both modified stent-grafts were suitable for laser PIV, enabling visualization of the flow fields and quantification of time average wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). RESULTS: Disturbed flow was observed at the bifurcation region of the AFX, especially at the end systolic velocity (ESV) time-point where recirculation was noticeable due to vortical flow. In contrast, predominantly unidirectional flow was observed at the CERAB bifurcation. These observations were confirmed by the quantified hemodynamic results from PIV analysis where mean TAWSS of 0.078 Pa (range: 0.009-0.242 Pa) was significantly lower in AFX as compared with 0.229 Pa (range: 0.013-0.906 Pa) for CERAB (p<0.001). Mean OSI of 0.318 (range: 0.123-0.496) in AFX was significantly higher than 0.252 (range: 0.055-0.472) in CERAB (p<0.001). Likewise, mean RRT of 180 Pa-1 (range: 9-3603 Pa-1) in AFX was also significantly higher than 88 Pa-1 (range: 2-840 Pa-1) in CERAB (p=0.0086). CONCLUSION: In this in vitro study, the flow pattern of a modified AFX stent-graft was found to be more disturbed especially at the end systolic phase, its hemodynamic outcomes less desirable than CERAB configuration. CLINICAL RELEVANCE: While the AFX stent-graft has an advantage over the CERAB configuration in eliminating radial mismatch, and maintaining the anatomical bifurcation for future endovascular intervention, this in vitro study revealed that the associated lower TAWSS, higher OSI and RRT may predispose to thrombosis and are, thus, less desirable as compared to a CERAB configuration. Further investigation is warranted to confirm whether these findings translate into the clinical setting.
Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Hemodinâmica , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Desenho de Prótese , Stents , Resultado do TratamentoRESUMO
BACKGROUND: Glomerular hyperfiltration resulting from an elevated intraglomerular pressure (Pglom) is an important cause of CKD, but there is no feasible method to directly assess Pglom in humans. We developed a model to estimate Pglom in patients from combined renal arterial pressure and flow measurements. METHODS: We performed hemodynamic measurements in 34 patients undergoing renal or cardiac angiography under baseline conditions and during hyperemia induced by intrarenal dopamine infusion (30 µg/kg). For each participant during baseline and hyperemia, we fitted an adapted three-element Windkessel model that consisted of characteristic impedance, compliance, afferent resistance, and Pglom. RESULTS: We successfully analyzed data from 28 (82%) patients. Median age was 58 years (IQR, 52-65), median eGFR was 95 ml/min per 1.73 m2 (IQR, 74-100) using the CKD-EPI formula, 30% had microalbuminuria, and 32% had diabetes. The model showed a mean Pglom of 48.0 mm Hg (SD=10.1) at baseline. Under hyperemia, flow increased by 88% (95% CI, 68% to 111%). This resulted in a 165% (95% CI, 79% to 294%) increase in afferent compliance and a 13.1-mm Hg (95% CI, 10.0 to 16.3) decrease in Pglom. In multiple linear regression analysis, diabetes (coefficient, 10.1; 95% CI, 5.1 to 15.1), BMI (0.99 per kg/m2; 95% CI, 0.38 to 1.59), and renal perfusion pressure (0.42 per mm Hg; 95% CI, 0.25 to 0.59) were significantly positively associated with baseline Pglom. CONCLUSIONS: We constructed a model on the basis of proximal renal arterial pressure and flow velocity measurements that provides an overall estimate of glomerular pressure and afferent and efferent resistance in humans. The model provides a novel research technique to evaluate the hemodynamics of CKD on the basis of direct pressure and flow measurements. CLINICAL TRIAL REGISTRY NAME AND REGISTRATION NUMBER: Functional HEmodynamics in patients with and without Renal Artery stenosis (HERA), NL40795.018.12 at the Dutch national trial registry (toetsingonline.nl).
Assuntos
Pressão Arterial/fisiologia , Glomérulos Renais/fisiologia , Artéria Renal/fisiologia , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Insuficiência Renal Crônica/fisiopatologiaRESUMO
The assessment of local blood flow patterns in patients with peripheral arterial disease is clinically relevant, since these patterns are related to atherosclerotic disease progression and loss of patency in stents placed in peripheral arteries, through mechanisms such as recirculating flow and low wall shear stress (WSS). However, imaging of vascular flow in these patients is technically challenging due to the often complex flow patterns that occur near atherosclerotic lesions. While several flow quantification techniques have been developed that could improve the outcomes of vascular interventions, accurate 2D or 3D blood flow quantification is not yet used in clinical practice. This article provides an overview of several important topics that concern the quantification of blood flow in patients with peripheral arterial disease. The hemodynamic mechanisms involved in the development of atherosclerosis and the current clinical practice in the diagnosis of this disease are discussed, showing the unmet need for improved and validated flow quantification techniques in daily clinical practice. This discussion is followed by a showcase of state-of-the-art blood flow quantification techniques and how these could be used before, during and after treatment of stenotic lesions to improve clinical outcomes. These techniques include novel ultrasound-based methods, Phase-Contrast Magnetic Resonance Imaging (PC-MRI) and Computational Fluid Dynamics (CFD). The last section discusses future perspectives, with advanced (hybrid) imaging techniques and artificial intelligence, including the implementation of these techniques in clinical practice.
Assuntos
Doença Arterial Periférica , Inteligência Artificial , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos , Hidrodinâmica , Imageamento por Ressonância Magnética , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Estresse MecânicoRESUMO
Having physiological correct flow waveforms is a key feature for experimental studies of blood flow, especially in the process of developing and testing a new medical device such as stent, mechanical heart valve, or any implantable medical device that involves circulation of blood through the device. It is also a critical part of a perfusion system for cardiopulmonary bypass and extracorporeal membrane oxygenation procedures. This study investigated the feasibility of a novel roller pump for use in experimental flow phantoms. Flow rates of carotid flow profile measured directly with the ultrasonic flow meter matched well with the reference flow rates programmed into the machine with similarity index of 0.97 and measured versus programmed flow rates at specific time-points of peak systolic velocity (PSV): 0.894 vs 0.880, end systolic velocity (ESV): 0.333 vs 0.319, and peak diastolic velocity (PDV): 0.514 vs 0.520 L/min. Flow rates derived from video analysis of the pump motion for carotid, suprarenal, and infrarenal flows also matched well with references with similarity indices of 0.99, 0.99, and 0.96, respectively. Measured flow rates (mean/standard deviation) at PSV, ESV, and PDV time-points for carotid: 0.883/0.016 vs 0.880, 0.342/0.007 vs 0.319, and 0.485/0.009 vs 0.520; suprarenal: 3.497/0.014 vs 3.500, 0.004/0.003 vs 0, and 1.656/0.073 vs 1.453; infrarenal: 4.179/0.024 vs 4.250, -1.147/0.015 vs -1.213, and 0.339/0.017 vs 0.391 L/min, respectively. The novel roller pump is suitable for benchtop testing of physiological flow.
Assuntos
Circulação Sanguínea/fisiologia , Coração Auxiliar , Artérias Carótidas/fisiologia , Humanos , Modelos Biológicos , Desenho de Prótese , Artéria Renal/fisiologiaRESUMO
PURPOSE: To describe a proximal extension of a failed chimney endovascular aneurysm sealing repair (chEVAS) using a chEVAS-in-chEVAS procedure in 2 cases with successful treatment outcome at 2-year follow-up. CASE REPORT: Two patients with an infrarenal abdominal aortic aneurysm were treated with an elective chEVAS procedure with 1 chimney stent for a unilateral renal artery. At 18 and 24 months, respectively, both patients showed aneurysm growth with an associated decrease in proximal seal. Both patients were treated with a secondary chEVAS procedure, consisting of chimney stent-graft placement in the contralateral renal and the superior mesenteric arteries combined with proximal extension of the in situ chimney stent-graft and the Nellix stents. Two-year follow-up demonstrated successful aneurysm exclusion with a patent stent configuration. CONCLUSION: A type Ia endoleak after chEVAS can be successfully repaired with a chEVAS-in-chEVAS procedure.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/cirurgia , Stents , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Progressão da Doença , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Reoperação , Falha de TratamentoRESUMO
OBJECTIVE: To achieve an optimal sealing zone during endovascular aneurysm repair, the intended positioning of the proximal end of the endograft fabric should be as close as possible to the most caudal edge of the renal arteries. Some endografts exhibit a small offset between the radiopaque markers and the proximal fabric edge. Unintended partial renal artery coverage may thus occur. This study investigated the consequences of partial coverage on renal flow patterns and wall shear stress (WSS). METHODS: In vitro models of an abdominal aortic aneurysm were used to visualize pulsatile flow using two-dimensional particle image velocimetry under physiologic resting conditions. One model served as control and two models were stented with an Endurant endograft (Medtronic Inc, Minneapolis, Minn), one without and one with partial renal artery coverage with 1.3 mm of stent fabric extending beyond the marker (16% area coverage). The magnitude and oscillation of WSS, relative residence time, and backflow in the renal artery were analyzed. RESULTS: In both stented models, a region along the caudal renal artery wall presented with low and oscillating WSS, not present in the control model. A region with very low WSS (<0.1 Pa) was present in the model with partial coverage over a length of 7 mm compared with a length of 2 mm in the model without renal coverage. Average renal backflow area percentage in the renal artery incrementally increased from control (0.9%) to the stented model without (6.4%) and with renal coverage (18.8%). CONCLUSIONS: In this flow model, partial renal coverage after endovascular aneurysm repair causes low and marked oscillations in WSS, potentially promoting atherosclerosis and subsequent renal artery stenosis. Awareness of the device-dependent offset between the fabric edge and the radiopaque markers is therefore important in endovascular practice.
Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Modelos Anatômicos , Modelos Cardiovasculares , Artéria Renal/cirurgia , Circulação Renal , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Humanos , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Obstrução da Artéria Renal/etiologia , Obstrução da Artéria Renal/fisiopatologia , Fatores de Risco , Stents , Estresse Mecânico , Fatores de TempoRESUMO
PURPOSE: To examine the influence of device positioning and infrarenal neck diameter on flow patterns in the Nellix endovascular aneurysm sealing (EVAS) system. METHODS: The transition of the aortic flow lumen into two 10-mm-diameter stents after EVAS creates a mismatched area. Flow recirculation may affect local wall shear stress (WSS) profiles and residence time associated with atherosclerosis and thrombosis. To examine these issues, 7 abdominal aortic aneurysm flow phantoms were created, including 3 unstented controls and 3 stented models with infrarenal neck diameters of 24, 28, and 32 mm. Stents were positioned within the instructions for use (IFU). Another 28-mm model was created to evaluate lower positioning of the stents outside the IFU (28-mm LP). Flow was visualized using optical particle imaging velocimetry (PIV) and quantified by time-averaged WSS (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) in the aorta at the anteroposterior (AP) midplane, lateral midplane, and renal artery AP midplane levels. RESULTS: Flow in the aorta AP midplane was similar in all models. Vortices were observed in the stented models in the lateral midplane near the anterior and posterior walls. In the 32-mm IFU and 28-mm LP models, a steady state of vortices appeared, with varying location during a cycle. In all models, a low TAWSS (<10-2 Pa) was observed at the anterior wall of the aorta with peak OSI of 0.5 and peak RRT of 104 Pa-1. This region was more proximally located in the stented models. The 24- and 28-mm IFU models showed flow with a higher velocity at the renal artery inflow compared to controls. TAWSS in the renal artery was lower near the orifice in all models, with the largest area in the 24-mm IFU model. OSI and RRT in the renal artery were near zero for all models. CONCLUSION: EVAS enhances vorticity proximal to the seal zone, especially with lower positioning of the device and in larger neck diameters. Endobags just below the renal artery affect the flow profile in a minor area of this artery in 24- and 28-mm necks, while lower stent positioning does not influence the renal artery flow profile.
Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Artéria Renal/cirurgia , Stents , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Hemodinâmica , Humanos , Modelos Anatômicos , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Circulação RenalRESUMO
Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Results: Similar flow features were observed between modalities with velocities up to 110 and 330 cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3 cm/s), with limits of agreement of ±25 cm/s (control) and ±34 cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55 cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. Conclusions: EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.
RESUMO
AIMS: Reflection magnitude (RM), the ratio of the amplitudes of the backward and forward central arterial pressure waves, has been shown to predict cardiovascular events. However, the association with blood pressure (BP) and hypertension is unclear. METHODS: We assessed RM in 10 195 individuals of Dutch, South-Asian Surinamese, African Surinamese, Ghanaian, Turkish and Moroccan origin aged between 18 and 70âyears (54.2% female) participating in the Healthy Life in an Urban Setting study. To determine RM, central arterial pressure and flow were reconstructed from finger BP. Hypertension was defined based on office-BP and medication. Associations with BP, hypertension, and hypertensive organ damage were assessed using linear regression models with correction for relevant covariates. RESULTS: Mean RM was 62.5% (standard deviation [SD] 8.0) in men and 63.8% (SD 8.1) in women. RM was lowest in Dutch and highest in South-Asian and African participants. RM increased linearly with 1.35 (95% confidence interval [CI] 1.23-1.46) for every 10âmmHg increase in systolic BP from 120âmmHg onwards, while the relation with diastolic BP was nonlinear. RM was 2.40 (95% CI 2.04-2.76) higher in hypertensive men and 3.82 (95% CI 3.46-4.19) higher in hypertensive women compared to normotensive men and women. In hypertensive men and women with ECG-based left ventricular hypertrophy or albuminuria RM was 1.64 (95% CI 1.09-2.20) and 0.94 (95% CI 0.37-1.52) higher compared to hypertensive participants without hypertensive organ damage. CONCLUSION: RM is associated with BP, hypertension and hypertensive organ damage, and may in part explain disparities in hypertension associated cardiovascular risk.
Assuntos
Hipertensão , Adolescente , Adulto , Idoso , Pressão Sanguínea , Etnicidade , Feminino , Gana , Humanos , Hipertrofia Ventricular Esquerda , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
OBJECTIVE: Augmentation index (AIx) is often used to quantify the contribution of wave reflection to central pulse pressure. Recent studies have challenged this view by showing how contractility-induced changes in the forward pressure wave can markedly impact AIx. We hypothesized that changes in preload will also affect AIx through changes in the forward wave and studied this in two experiments. METHODS: Noninvasively obtained aortic pressure was used to study central haemodynamics and wave morphology. In the first experiment, we examined the effects of head-up tilt with and without unilateral thigh cuff in 12 young healthy volunteers (mean age 26 years, 50% men). In the second experiment, we examined the effects of active standing in 31 middle-aged patients (mean age 57 years, 65% men) before and after phlebotomy. RESULTS: Head-up tilt or active standing significantly decreased AIx [-17.7â±â10.4 percentage point (pp) in the young population, -4.7â±â12.3âpp in the middle-aged population, both Pâ<â0.05]. The fall in AIx was associated with increases in HR, diastolic pressure and systemic vascular resistance and a decrease in stroke volume (all Pâ<â0.05). Inflation of a unilateral thigh cuff reduced the decrease in AIx by 10.7âpp, whereas 500âml of blood loss augmented the fall in AIx by 5.9âpp (both Pâ<â0.05). The changes in AIx were related to a preload-induced change in forward pressure wave shape (earlier peaking and steeper downstroke). CONCLUSION: Next to inotropic and chronotropic effects, preload emerges as another myocardial factor that obscures the relation between wave reflection and AIx.