Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Epilepsia ; 62(10): 2333-2343, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34240748

RESUMO

OBJECTIVE: Wearable seizure detection devices could provide more reliable seizure documentation outside the hospital compared to seizure self-reporting by patients, which is the current standard. Previously, during the SeizeIT1 project, we studied seizure detection based on behind-the-ear electroencephalography (EEG). However, the obtained sensitivities were too low for practical use, because not all seizures are associated with typical ictal EEG patterns. Therefore, in this paper, we aim to develop a multimodal automated seizure detection algorithm integrating behind-the-ear EEG and electrocardiography (ECG) for detecting focal seizures. In this framework, we quantified the added value of ECG to behind-the-ear EEG. METHODS: This study analyzed three multicenter databases consisting of 135 patients having focal epilepsy and a total of 896 seizures. A patient-specific multimodal automated seizure detection algorithm was developed using behind-the-ear/temporal EEG and single-lead ECG. The EEG and ECG data were processed separately using machine learning methods. A late integration approach was applied for fusing those predictions. RESULTS: The multimodal algorithm outperformed the EEG-based algorithm in two of three databases, with an increase of 11% and 8% in sensitivity for the same false alarm rate. SIGNIFICANCE: ECG can be of added value to an EEG-based seizure detection algorithm using only behind-the-ear/temporal lobe electrodes for patients with focal epilepsy.


Assuntos
Epilepsias Parciais , Dispositivos Eletrônicos Vestíveis , Algoritmos , Eletrocardiografia , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Humanos , Convulsões/diagnóstico
2.
Epilepsia ; 62(11): 2741-2752, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34490891

RESUMO

OBJECTIVE: Patients with absence epilepsy sensitivity <10% of their absences. The clinical gold standard to assess absence epilepsy is a 24-h electroencephalographic (EEG) recording, which is expensive, obtrusive, and time-consuming to review. We aimed to (1) investigate the performance of an unobtrusive, two-channel behind-the-ear EEG-based wearable, the Sensor Dot (SD), to detect typical absences in adults and children; and (2) develop a sensitive patient-specific absence seizure detection algorithm to reduce the review time of the recordings. METHODS: We recruited 12 patients (median age = 21 years, range = 8-50; seven female) who were admitted to the epilepsy monitoring units of University Hospitals Leuven for a 24-h 25-channel video-EEG recording to assess their refractory typical absences. Four additional behind-the-ear electrodes were attached for concomitant recording with the SD. Typical absences were defined as 3-Hz spike-and-wave discharges on EEG, lasting 3 s or longer. Seizures on SD were blindly annotated on the full recording and on the algorithm-labeled file and consequently compared to 25-channel EEG annotations. Patients or caregivers were asked to keep a seizure diary. Performance of the SD and seizure diary were measured using the F1 score. RESULTS: We concomitantly recorded 284 absences on video-EEG and SD. Our absence detection algorithm had a sensitivity of .983 and false positives per hour rate of .9138. Blind reading of full SD data resulted in sensitivity of .81, precision of .89, and F1 score of .73, whereas review of the algorithm-labeled files resulted in scores of .83, .89, and .87, respectively. Patient self-reporting gave sensitivity of .08, precision of 1.00, and F1 score of .15. SIGNIFICANCE: Using the wearable SD, epileptologists were able to reliably detect typical absence seizures. Our automated absence detection algorithm reduced the review time of a 24-h recording from 1-2 h to around 5-10 min.


Assuntos
Epilepsia Tipo Ausência , Dispositivos Eletrônicos Vestíveis , Adolescente , Adulto , Algoritmos , Criança , Eletroencefalografia/métodos , Epilepsia Tipo Ausência/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Convulsões/diagnóstico , Adulto Jovem
3.
Sensors (Basel) ; 21(4)2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33557034

RESUMO

Wearable technology will become available and allow prolonged electroencephalography (EEG) monitoring in the home environment of patients with epilepsy. Neurologists analyse the EEG visually and annotate all seizures, which patients often under-report. Visual analysis of a 24-h EEG recording typically takes one to two hours. Reliable automated seizure detection algorithms will be crucial to reduce this analysis. We investigated such algorithms on a dataset of behind-the-ear EEG measurements. Our first aim was to develop a methodology where part of the data is deferred to a human expert, who performs perfectly, with the goal of obtaining an (almost) perfect detection sensitivity (DS). Prediction confidences are determined by temperature scaling of the classification model outputs and trust scores. A DS of approximately 90% (99%) can be achieved when deferring around 10% (40%) of the data. Perfect DS can be achieved when deferring 50% of the data. Our second contribution demonstrates that a common modelling strategy, where predictions from several short EEG segments are combined to obtain a final prediction, can be improved by filtering out untrustworthy segments with low trust scores. The false detection rate shows a relative decrease between 21% and 43%, and the DS shows a small increase or decrease.


Assuntos
Epilepsia , Confiança , Algoritmos , Eletroencefalografia , Epilepsia/diagnóstico , Humanos , Convulsões/diagnóstico , Sensibilidade e Especificidade
4.
Epilepsia ; 61(4): 766-775, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32160324

RESUMO

OBJECTIVE: Seizure diaries kept by patients are unreliable. Automated electroencephalography (EEG)-based seizure detection systems are a useful support tool to objectively detect and register seizures during long-term video-EEG recording. However, this standard full scalp-EEG recording setup is of limited use outside the hospital, and a discreet, wearable device is needed for capturing seizures in the home setting. We are developing a wearable device that records EEG with behind-the-ear electrodes. In this study, we determined whether the recognition of ictal patterns using only behind-the-ear EEG channels is possible. Second, an automated seizure detection algorithm was developed using only those behind-the-ear EEG channels. METHODS: Fifty-four patients with a total of 182 seizures, mostly temporal lobe epilepsy (TLE), and 5284 hours of data, were recorded with a standard video-EEG at University Hospital Leuven. In addition, extra behind-the-ear EEG channels were recorded. First, a neurologist was asked to annotate behind-the-ear EEG segments containing selected seizure and nonseizure fragments. Second, a data-driven algorithm was developed using only behind-the-ear EEG. This algorithm was trained using data from other patients (patient-independent model) or from the same patient (patient-specific model). RESULTS: The visual recognition study resulted in 65.7% sensitivity and 94.4% specificity. By using those seizure annotations, the automated algorithm obtained 64.1% sensitivity and 2.8 false-positive detections (FPs)/24 hours with the patient-independent model. The patient-specific model achieved 69.1% sensitivity and 0.49 FPs/24 hours. SIGNIFICANCE: Visual recognition of ictal EEG patterns using only behind-the-ear EEG is possible in a significant number of patients with TLE. A patient-specific seizure detection algorithm using only behind-the-ear EEG was able to detect more seizures automatically than what patients typically report, with 0.49 FPs/24 hours. We conclude that a large number of refractory TLE patients can benefit from using this device.


Assuntos
Algoritmos , Eletroencefalografia/instrumentação , Epilepsia do Lobo Temporal/diagnóstico , Convulsões/diagnóstico , Processamento de Sinais Assistido por Computador , Eletrodos , Eletroencefalografia/métodos , Epilepsia do Lobo Temporal/complicações , Feminino , Humanos , Masculino , Convulsões/etiologia , Sensibilidade e Especificidade , Dispositivos Eletrônicos Vestíveis
5.
Sensors (Basel) ; 17(10)2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-29027928

RESUMO

Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.


Assuntos
Eletrocardiografia , Epilepsia , Fotopletismografia , Convulsões/diagnóstico , Dispositivos Eletrônicos Vestíveis , Algoritmos , Eletroencefalografia , Frequência Cardíaca , Hospitais , Humanos
6.
Bioengineering (Basel) ; 10(4)2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37106678

RESUMO

Long-term home monitoring of people living with epilepsy cannot be achieved using the standard full-scalp electroencephalography (EEG) coupled with video. Wearable seizure detection devices, such as behind-the-ear EEG (bte-EEG), offer an unobtrusive method for ambulatory follow-up of this population. Combining bte-EEG with electrocardiography (ECG) can enhance automated seizure detection performance. However, such frameworks produce high false alarm rates, making visual review necessary. This study aimed to evaluate a semi-automated multimodal wearable seizure detection framework using bte-EEG and ECG. Using the SeizeIT1 dataset of 42 patients with focal epilepsy, an automated multimodal seizure detection algorithm was used to produce seizure alarms. Two reviewers evaluated the algorithm's detections twice: (1) using only bte-EEG data and (2) using bte-EEG, ECG, and heart rate signals. The readers achieved a mean sensitivity of 59.1% in the bte-EEG visual experiment, with a false detection rate of 6.5 false detections per day. Adding ECG resulted in a higher mean sensitivity (62.2%) and a largely reduced false detection rate (mean of 2.4 false detections per day), as well as an increased inter-rater agreement. The multimodal framework allows for efficient review time, making it beneficial for both clinicians and patients.

7.
J Neural Eng ; 19(1)2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-35158349

RESUMO

Objective. Video-electroencephalography (vEEG), which defines the ground truth for the detection of epileptic seizures, is inadequate for long-term home monitoring. Thanks to advantages in comfort and unobtrusiveness, wearable EEG devices have been suggested as a solution for home monitoring. However, one of the challenges in data-driven automated seizure detection with wearable EEG data is to have reliable seizure annotations. Seizure annotations on the gold-standard 25-channel vEEG recordings may not be optimal to delineate seizure activity on the concomitantly recorded wearable EEG, due to artifacts or absence of ictal activity on the limited set of electrodes of the wearable EEG. This paper aims to develop an automatic approach to correct for imperfect annotations of seizure activity on wearable EEG, which can be used to train seizure detection algorithms.Approach. This paper first investigates the effectiveness of correcting the seizure annotations for the training set with a visual annotation correction. Then a novel approach has been proposed to automatically remove non-seizure data from wearable EEG in epochs annotated as seizures in gold-standard video-EEG recordings. The performance of the automatic annotation correction approach was evaluated by comparing the seizure detection models trained with (a) original vEEG seizure annotations, (b) visually corrected seizure annotations, and (c) automatically corrected seizure annotations.Main results. The automated seizure detection approach trained with automatically corrected seizure annotations was more sensitive and had fewer false-positive detections compared to the approach trained with visually corrected seizure annotations, and the approach trained with the original seizure annotations from gold-standard vEEG.Significance. The wearable EEG seizure detection approach performs better when trained with automatic seizure annotation correction.


Assuntos
Epilepsia , Dispositivos Eletrônicos Vestíveis , Algoritmos , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Humanos , Convulsões/diagnóstico
8.
Front Neurol ; 11: 145, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32161573

RESUMO

Objective: Automated seizure detection is a key aspect of wearable seizure warning systems. As a result, the quality of life of refractory epilepsy patients could be improved. Most state-of-the-art algorithms for heart rate-based seizure detection use a so-called patient-independent approach, which do not take into account patient-specific data during algorithm training. Although such systems are easy to use in practice, they lead to many false detections as the ictal heart rate changes are patient-dependent. In practice, only a limited amount of accurately annotated patient data is typically available, which makes it difficult to create fully patient-specific algorithms. Methods: In this context, this study proposes for the first time a new transfer learning approach that allows to personalize heart rate-based seizure detection by using only a couple of days of data per patient. The algorithm was evaluated on 2,172 h of single-lead ECG data from 24 temporal lobe epilepsy patients including 227 focal impaired awareness seizures. Results: The proposed personalized approach resulted in an overall sensitivity of 71% with 1.9 false detections per hour. This is an average decrease in false detection rate of 37% compared to the reference patient-independent algorithm using only a limited amount of personal seizure data. The proposed transfer learning approach adapts faster and more robustly to patient-specific characteristics than other alternatives for personalization in the literature. Conclusion: The proposed method allows an easy implementable solution to personalize heart rate-based seizure detection, which can improve the quality of life of refractory epilepsy patients when used as part of a multimodal seizure detection system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA