Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 24(6): 6052-62, 2016 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-27136799

RESUMO

Sensors based on whispering gallery modes have been extensively investigated with respect to their possible application as physical or biological sensors. Instead of using a single resonator, we use an all polymer resonator array as sensing element. A tunable narrowband laser is coupled into a PMMA plate serving as an optical wave guide. PMMA spheres are placed in the evanescent field on the surface of the plate. Due to small size variations, some spheres are in resonance at a given wavelength while others are not. We show that this device is well suited for the determination of an unknown wavelength or for temperature measurements. Moreover, we discuss several general aspects of the sensor concept such as the number and size of sensing elements which are necessary for a correct measurement result, or the maximum acceptable linewidth of the laser.

2.
J Biophotonics ; 11(6): e201700288, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29360199

RESUMO

A new multimodal system for rapid, noninvasive in vivo skin cancer screening is presented, combining optical coherence tomography (OCT) and optoacoustic (OA) modalities to provide precise tumor depth determination with a Raman spectroscopic modality capable of detecting the lesion type and, thus, providing diagnostic capability. Both OA and Raman setups use wide field skin illumination to ensure the compliance with maximum permissible exposure (MPE) requirements. The Raman signal is collected via the OCT scanning lens to maximize the signal-to-noise ratio of the measured signal while keeping radiation levels below MPE limits. OCT is used to optically determine the tumor thickness and for volumetric imaging whereas OA utilizes acoustic signals generated by optical absorption contrast for thickness determination at potentially higher penetration depths compared to OCT. Preliminary results of first clinical trials using our setup are presented. The measured lesion depth is in good agreement with histology results, while Raman measurements show distinctive differences between normal skin and melanocytic lesions, and, moreover, between different skin areas. In future, we will validate the setup presented for reliable detection of pathophysiological parameters, morphology and thickness of suspicious skin lesions.


Assuntos
Programas de Rastreamento/métodos , Técnicas Fotoacústicas , Neoplasias Cutâneas/diagnóstico , Análise Espectral Raman , Tomografia de Coerência Óptica , Detecção Precoce de Câncer , Eletrodos , Humanos , Programas de Rastreamento/instrumentação , Sensibilidade e Especificidade , Neoplasias Cutâneas/diagnóstico por imagem
3.
J Biomed Opt ; 22(10): 1-7, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29076311

RESUMO

Optical techniques are effective tools for diagnostic applications in medicine and are particularly attractive for the noninvasive analysis of biological tissues and fluids in vivo. Noninvasive examinations of substances via a fiber optic probe need to consider the optical properties of biological tissues obstructing the optical path. This applies to the analysis of the human perilymph, which is located behind the round window membrane. The composition of this inner ear liquid is directly correlated to inner ear hearing loss. In this work, experimental methods for studying the optical properties of the human round window membrane ex vivo are presented. For the first time, a comprehensive investigation of this tissue is performed, including optical transmission, forward scattering, and Raman scattering. The results obtained suggest the application of visible wavelengths (>400 nm) for investigating the perilymph behind the round window membrane in future.


Assuntos
Perda Auditiva Neurossensorial/diagnóstico por imagem , Janela da Cóclea/diagnóstico por imagem , Orelha Interna/diagnóstico por imagem , Humanos , Perilinfa/diagnóstico por imagem , Análise Espectral Raman
4.
J Biophotonics ; 10(6-7): 854-861, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28009131

RESUMO

A reliable, fast, and non-invasive determination of melanoma thickness in vivo is highly desirable for clinical dermatology as it may facilitate the identification of surgical melanoma margins, determine if a sentinel node biopsy should be performed or not, and reduce the number of surgical interventions for patients. In this work, optical coherence tomography (OCT) and high frequency ultrasound (HFUS) are evaluated for quantitative in vivo preoperative assessment of the skin infiltration depth of melanocytic tissue. Both methods allow non-invasive imaging of skin at similar axial resolution. Comparison with the Breslow lesion thickness obtained from histopathology revealed that OCT is slightly more precise in terms of thickness determination while HFUS has better contrast. The latter does not require image post-processing, as necessary for the OCT images. The findings of our pilot study suggest that non-invasive OCT and HFUS are able to determine the infiltration depth of lesions like melanocytic nevi or melanomas preoperatively and in vivo with a precision comparable to invasive histopathology measurements on skin biopsies. In future, to further strengthen our findings a statistically significant study comprising a larger amount of data is required which will be conducted in an extended clinical study in the next step. Comparison of optical coherence tomography and high frequency ultrasound B-Scans and a H&E stained histology of a melanocytic nevus.


Assuntos
Melanoma/diagnóstico por imagem , Nevo Pigmentado/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem , Tomografia de Coerência Óptica , Ultrassonografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Melanócitos , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA