Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Catheter Cardiovasc Interv ; 92(3): 488-496, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29068171

RESUMO

OBJECTIVES: To assess the safety and efficacy of everolimus-eluting bioresorbable scaffolds (BRS) in the treatment of chronic total occlusions (CTO) using noninvasive multislice computed tomography (MSCT) angiography at one-year follow-up. BACKGROUND: Current evidence regarding the safety and efficacy of BRS for the percutaneous treatment of CTO is limited. METHODS: Between September 2013 and January 2016, patients who received one or more ABSORB BRSs were included at three centers. MSCT (including quantitative analysis) and clinical follow-up were performed at one year. RESULTS: Forty-one CTO patients were included. Mean age was 60 ± 11 years and the majority was male (83%). Average Japanese CTO (J-CTO) score was 0.9 ± 0.9. Seventy-one BRS were implanted in total with, on average, 1.7 ± 0.8 scaffolds/patient, and a total length of 43 ± 20 mm and diameter of 3.1 ± 0.4 mm. One noncardiac death took place. MSCT angiography was performed in 34 (83%) patients: all scaffolds were patent, except in one patient, in whom a patent target vessel was present on subsequent diagnostic angiography. MSCT quality was sufficient for quantitative analyses in 27 patients (46 scaffolds): median reference versus scaffold minimal lumen diameter and minimal lumen area were measured, and showed a small difference of 0.1 mm (-0.2-0.4) (lumen diameter stenosis = 3.0%) and 0.5 mm2 (-1.0-2.0) (lumen area stenosis = 4.2%). CONCLUSIONS: The low number of events and high patency rate at 1 year are encouraging the further use of the ABSORB scaffold for CTOs with low J-CTO score. Noninvasive MSCT angiography is a valid tool to assess scaffold patency, although its image resolution limits the use for quantitative measurements.


Assuntos
Implantes Absorvíveis , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Intervenção Coronária Percutânea/instrumentação , Idoso , Fármacos Cardiovasculares/administração & dosagem , Doença Crônica , Materiais Revestidos Biocompatíveis , Oclusão Coronária/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Europa (Continente) , Everolimo/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Acta Cardiol ; 73(4): 335-341, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28971753

RESUMO

BACKGROUND: This study investigates spot urinary chloride concentration in euvolemic chronic heart failure (CHF) patients. METHODS: This prospective cohort study included 50 ambulatory CHF patients on maintenance loop diuretics without recent hospital admission, clinical signs of volume overload, or adjustment in neurohumoral blocker or diuretic therapy. Spot urinary samples were collected immediately after loop diuretic intake. Subsequently, loop diuretic dose was reduced with 50% or stopped if ≤40 mg furosemide equivalents. Successful down-titration was defined as persistent dose reduction after 7 d without body weight increase >1.5 kg. RESULTS: Urinary chloride concentration was 3045 ± 1271 mg/L overall. Patients with higher versus lower urinary chloride concentrations took the same dose of loop diuretics [40 mg (20-40 mg) furosemide equivalents; p value = .509] and had similar plasma NT-proBNP levels [1179 ng/L (311-2195 ng/L) versus 900 ng/L (255-1622 ng/L), respectively; p value = .461]. Down-titration was successful in 72% versus 76%, respectively (p value = 1.000). At 30 d, loop diuretic dose remained reduced in 59% versus 76% of patients, respectively (p value = .238). The proportion of patients free from diuretic therapy was 45% versus 62% in the high versus low chloride concentration group (p value = .265). CONCLUSIONS: Loop diuretic down-titration was successful in 3 out of 4 euvolemic CHF patients, irrespectively of urinary chloride concentration on spot samples collected after diuretic intake.


Assuntos
Cloratos/urina , Furosemida/administração & dosagem , Insuficiência Cardíaca/tratamento farmacológico , Volume Sistólico/fisiologia , Idoso , Biomarcadores/urina , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/urina , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Inibidores de Simportadores de Cloreto de Sódio e Potássio/administração & dosagem , Resultado do Tratamento
3.
Echocardiography ; 32(3): 557-64, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25048733

RESUMO

PURPOSE: Echocardiography is increasingly important in the guidance and follow-up of percutaneous transcatheter device closures. It was recently shown that the Amplatzer left atrial appendage occluder frequently presents as a figure-of-eight artifact due to interaction of device mesh and ultrasound waves. It remains unknown whether this can be translated to other types of disc occluders. Furthermore, the morphology of this figure-of-eight artifact appears to be different in the transesophageal and transthoracic image of the same device. The aim of this study was to evaluate the echocardiographic appearance of different types of disc occluders, and to clarify differences in morphology of the figure-of-eight artifact. METHODS: A mathematical model of an epitrochoid curve was used for numerical simulation of disc occluder appearance at various imaging depths. In addition, an in vitro setup was used for echocardiographic analysis of different types of disc occluders at adjustable imaging depth and position. RESULTS: Mathematically, decreasing the imaging depth resulted in a more asymmetric figure-of-eight, i.e. with small upper part and wide lower part. In vitro results were in close agreement with the mathematical results. In addition, in vitro a figure-of-eight artifact was obtained in all different types of disc occluder devices. CONCLUSIONS: Different types of percutaneous disc occluders all present as a figure-of-eight artifact on echocardiography when imaged from a coronal imaging position. The morphology of the artifact depends on the imaging depth, with a more asymmetric figure-of-eight morphology at smaller probe-to-device distance. This clarifies the differences observed between transesophageal and transthoracic imaging.


Assuntos
Artefatos , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Dispositivo para Oclusão Septal , Análise de Falha de Equipamento , Imagens de Fantasmas , Desenho de Prótese , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Acta Cardiol ; 70(3): 265-73, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26226699

RESUMO

OBJECTIVE: The objective of this study was to investigate determinants of the natriuretic response to diuretics in decompensated heart failure (HF) and the relationship with decongestion, neurohumoral activation and clinical outcome in the contemporary era of HF management. METHODS AND RESULTS: In this prospective, single-centre cohort study, consecutive patients with decompensated HF (n = 54) and left ventricular ejection fraction 45% received protocol-driven diuretic therapy until complete disappearance of congestion signs. Urine was collected during three consecutive 24-h intervals. Natriuretic response was defined as absolute natriuresis (mmol) per mg of intravenous bumetanide administered. Natriuresis was 146 mmol (76-206 mmol), 74 mmol (37-167 mmol) and 74 mmol (53-134 mmol) per mg intravenous bumetanide administered during the first, second and third 24-h interval, respectively. Diastolic blood pressure (beta = 23.048 +/- 10.788; P-value = 0.036), plasma aldosterone (beta = -25.722?11.560; P-value=0.029), and combination therapy with acetazolamide (beta = 103.241 +/- 40.962; P-value = 0.014) were independent predictors of the natriuretic response. Patients with a stronger natriuretic response demonstrated more pronounced decreases in plasma NT-proBNP levels (P-value = 0.025), while a weaker response was associated with higher peak plasma aldosterone levels (P-value = 0.013) and plasma renin activity (P-value = 0.033). Natriuresis per loop diuretic dose predicted freedom from all-cause mortality or HF readmissions, independently of baseline renal function (HR 0.40, 95% CI 0.16-0.98; P-value = 0.045). CONCLUSIONS: More effective natriuresis in decompensated HF patients with reduced ejection fraction and volume overload is associated with better decongestion, less neurohumoral activation and predicts favourable clinical outcome independently from renal function per se. Acetazolamide warrants further evaluation in large prospective trials to increase the natriuretic response to loop diuretics.


Assuntos
Diuréticos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Natriurese/efeitos dos fármacos , Volume Sistólico/efeitos dos fármacos , Idoso , Bumetanida/farmacologia , Bumetanida/uso terapêutico , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Inibidores de Simportadores de Cloreto de Sódio e Potássio/uso terapêutico
5.
Europace ; 16(8): 1197-204, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24489074

RESUMO

AIMS: To assess the influence of device-registered episodes of atrial tachyarrhythmia (AT) on the response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Consecutive CRT patients without history of atrial fibrillation (AF; n = 118) were followed prospectively. AT was defined as a device-registered episode of atrial rate >190 b.p.m. for ≥30 s. Episodes of electrocardiographically documented AF, accompanied by symptoms, or need for cardioversion, were classified as clinical AF. During mean follow-up of 26 ± 9 months, 39 patients (33%) had ≥1 episode of asymptomatic device-registered AT. Twenty-one patients (18%) developed clinical AF of whom seven had previously experienced episodes of asymptomatic device-registered AT. Patients with asymptomatic AT or AF had a higher body mass index, but otherwise similar baseline characteristics, compared with the subjects without AT. Reverse remodelling after CRT was similar among the groups. While clinical AF was significantly associated with the composite endpoint of all-cause mortality or unplanned hospital admission (hazard ratio = 2.43, 95% confidence interval: 1.40-4.24), this correlation was not observed in patients with asymptomatic device-registered AT (P value = 0.540). CONCLUSION: Episodes of asymptomatic device-registered AT are frequent in CRT patients, but are not associated with impaired reverse remodelling. In contrast to clinical AF, such episodes are not associated with worse clinical outcome.


Assuntos
Fibrilação Atrial/epidemiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Taquicardia Supraventricular/epidemiologia , Doenças Assintomáticas , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Bélgica/epidemiologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Cardioversão Elétrica , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/mortalidade , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Fatores de Tempo , Resultado do Tratamento
6.
J Heart Valve Dis ; 23(3): 360-3, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25296462

RESUMO

The case is reported of a 38-year-old male patient with pulmonary homograft acute infective endocarditis and aortic root dilation that occurred 13 years after a Ross procedure for bicuspid aortic valve regurgitation. Aortic and pulmonary root replacements were performed, using a Freestyle stentless aortic root bioprosthesis in both cases, with excellent hemodynamics on postoperative echocardiography. In addition, preoperative systemic septic embolization had occurred despite an absence of left-sided endocarditis, presumably due to an intrapulmonary shunt. This case report demonstrates the feasibility of a double stentless bioprosthesis approach, and stresses the need to remain vigilant for septic embolization even in isolated right-sided endocarditis.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Endocardite Bacteriana/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Valva Pulmonar/cirurgia , Aloenxertos , Autoenxertos , Bioprótese/efeitos adversos , Endocardite Bacteriana/complicações , Endocardite Bacteriana/fisiopatologia , Hemodinâmica , Humanos , Embolia Intracraniana/etiologia , Masculino , Infecções Relacionadas à Prótese/complicações , Infecções Relacionadas à Prótese/fisiopatologia
7.
Echocardiography ; 31(1): E30-2, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23742271

RESUMO

We present the case of a young man with severe eccentric aortic regurgitation, obstructing mitral inflow and provoking an audible Austin Flint murmur at clinical examination. Two-dimensional color Doppler echocardiography depicts the remarkable mechanical interaction between aortic regurgitant jet and anterior mitral leaflet opening. Three-dimensional transesophageal echocardiography aids in understanding the geometric and hemodynamic consequences of the regurgitant jet and in the genesis of the Austin Flint murmur. This case accentuates the incremental value of three-dimensional echocardiography when evaluating valvular pathology, and offers more insight in the interaction between aortic regurgitant flow and mitral leaflet dynamics.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia Tridimensional/métodos , Sopros Cardíacos/fisiopatologia , Valva Mitral/anormalidades , Valva Mitral/fisiopatologia , Adulto , Insuficiência da Valva Aórtica/etiologia , Velocidade do Fluxo Sanguíneo , Sistemas Computacionais , Circulação Coronária , Sopros Cardíacos/diagnóstico , Sopros Cardíacos/etiologia , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Resultado do Tratamento
8.
Europace ; 15(12): 1747-56, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23821473

RESUMO

AIMS: Intraventricular dyssynchrony and commonly associated prolonged atrioventricular conduction both reduce diastolic filling time (DFT), which can be improved by cardiac resynchronization therapy (CRT). Our aim was to investigate whether change in DFT corrected for RR interval (DFTC) after CRT might serve to assess the mechanistic response to CRT. METHODS AND RESULTS: Echocardiography data of consecutive patients in sinus rhythm (n = 91) were studied before and 6 months after implantation. Mortality and heart failure hospitalization data were collected. Patients with vs. without DFTC increase after 6 months were compared. The programmed atrioventricular delay, percentage of biventricular pacing, and change in PR interval were similar in both groups. DFTC increase after 6 months reflected favourable reverse left ventricular remodelling and was significantly associated with freedom from death or heart failure admission (P = 0.008). In multivariate analysis including guideline criteria for CRT (i.e. QRS width, presence of left bundle branch block, and ejection fraction), interventricular mechanical delay, and Tei index, baseline DFTC was the strongest predictor of adverse outcome. Notably, while patients with impaired relaxation had a large and highly significant reduction in all-cause mortality and heart failure admissions when DFTC increased [hazard ratio (HR), 95% confidence interval (CI) = 0.24, 0.08-0.73; P = 0.012], this benefit was less pronounced and did not reach statistical significance in patients with pseudonormal or restrictive filling (HR, 95% CI = 0.64, 0.23-1.77; P = 0.388). CONCLUSION: DFTC increase after CRT reflects favourable reverse remodelling and is associated with better clinical outcome.


Assuntos
Bloqueio Atrioventricular/terapia , Terapia de Ressincronização Cardíaca , Diástole , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/mortalidade , Bloqueio Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
9.
Acta Cardiol ; 68(1): 37-45, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23457908

RESUMO

OBJECTIVE: Cardiac resynchronization therapy (CRT) is an important treatment modality for heart failure with reduced ejection fraction and ventricular conduction delay. Considering limited health care budgets in an aging population, adding a defibrillator function to CRT remains a matter of debate. Our aim was to describe the experience of a high-volume Belgian implantation centre with CRT with/without defibrillator (CRT-D/P). METHODS AND RESULTS: Consecutive CRT patients (n = 221), implanted between October 2008 and April 2011 in Ziekenhuis Oost-Limburg (Genk), were reviewed. From 209 primo-implantations, 74 CRT-D and 98 CRT-P patients with complete follow-up inside the centre, were analysed. Despite differences in baseline characteristics, both groups demonstrated similar reverse left ventricular remodelling, improvement in New York Heart Association functional class and maximal aerobic capacity. During mean follow-up of 18 +/- 9 months, 21 patients died and 83 spent a total of 1200 days in hospital. Annual mortality was 8% and equal among the groups. The mode of death differed between CRT-D (predominantly pump failure) and CRT-P patients (pump failure, comorbidity and sudden death). The yearly population attributable risk of malignant ventricular arrhythmia was 8.16% in CRT-D and 1.38% in CRT-P patients. CONCLUSIONS: With current guidelines applied to the Belgian reimbursement criteria and at physicians'discretion, patient selection for CRT-D/ CRT-P was appropriate, with similar reverse remodelling, functional capacity improvement and good clinical outcome in both groups. High-risk patients for malignant ventricular arrhythmia were more likely to receive CRT-D, although the yearly attributable risk remained 1.38% in CRT-P patients.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Idoso de 80 Anos ou mais , Bélgica , Feminino , Humanos , Masculino
10.
Acta Cardiol ; 78(8): 889-893, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36597848

RESUMO

BACKGROUND: Coronary artery spasm is a well-known potential side effect of selective 5-hydroxytryptamine type 1 (5HT1) receptor agonists and, therefore, contraindicated in patients with cardiovascular disease. SARS-CoV-2 vaccination has been associated with myocarditis, mainly in young men. CASE SUMMARY: A 55-year-old man with longstanding cluster headache, treated with the 5HT1-agonist Sumatriptan for ten years, received the mRNA-1273 SARS-CoV-2 booster vaccine. Four days later, he developed severe retrosternal pain several minutes after administering Sumatriptan with electrographic ST-elevation and a raised high-sensitivity cardiac troponin-T (hs-cTnT). Coronary angiogram was normal, but a diagnosis of acute myocarditis and hyperthyroidism secondary to Graves' disease was made. DISCUSSION: We present a case of severe coronary artery spasm induced by a 5HT1-agonist secondary to newly diagnosed Graves' disease and myocarditis. The mRNA-1273 SARS-CoV-2 booster vaccine administered four days before admission probably triggered both immunoreactions.


Assuntos
COVID-19 , Vasoespasmo Coronário , Doença de Graves , Miocardite , Masculino , Humanos , Pessoa de Meia-Idade , Serotonina , Sumatriptana , Miocardite/diagnóstico , Miocardite/etiologia , RNA Viral , Vacina de mRNA-1273 contra 2019-nCoV , Vacinas contra COVID-19/efeitos adversos , COVID-19/diagnóstico , SARS-CoV-2 , Doença de Graves/diagnóstico , Vacinação
11.
J Am Soc Echocardiogr ; 36(8): 824-831, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37191596

RESUMO

BACKGROUND: Hemostasis within the left atrial appendage (LAA) is a common cause of stroke, especially in patients with atrial fibrillation (AF). Although LAA flow provides insights into LAA function, its potential for predicting AF has yet to be established. The aim of this study was to explore whether LAA peak flow velocities early after cryptogenic stroke are associated with future AF on prolonged rhythm monitoring. METHODS: A total of 110 patients with cryptogenic stroke were consecutively enrolled and underwent LAA pulsed-wave Doppler flow assessment using transesophageal echocardiography within the early poststroke period. Velocity measurements were analyzed offline by an investigator blinded to the results. Prolonged rhythm monitoring was conducted on all participants via 7-day Holter and implantable cardiac monitoring devices, with follow-up conducted over a period of 1.5 years to determine the incidence of AF. The end point of AF was defined as irregular supraventricular rhythm with variable RR interval and no detectable P waves lasting ≥30 sec during rhythm monitoring. RESULTS: During a median follow-up period of 539 days (interquartile range, 169-857 days), 42 patients (38%) developed AF, with a median time to AF diagnosis of 94 days (interquartile range, 51-487 days). Both LAA filling velocity and LAA emptying velocity (LAAev) were lower in patients with AF (44.3 ± 14.2 and 50.7 ± 13.3 cm/s, respectively) compared with patients without AF (59.8 ± 14.0 and 76.8 ± 17.3 cm/sec, respectively; P < .001 for both). LAAev was most strongly associated with future AF, with an area under the receiver operating characteristic curve of 0.88 and an optimal cutoff value of 55 cm/sec. Age and mitral regurgitation were independent determinants of reduced LAAev. CONCLUSIONS: Impaired LAA peak flow velocities (LAAev < 55 cm/sec) in patients with cryptogenic stroke are associated with future AF. This may facilitate the selection of appropriate candidates for prolonged rhythm monitoring to improve its diagnostic accuracy and implementation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Apêndice Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia
12.
J Card Fail ; 18(11): 845-53, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23141857

RESUMO

BACKGROUND: The influence of comorbid conditions on ventricular remodeling, functional status, and clinical outcome after cardiac resynchronization therapy (CRT) is insufficiently elucidated. METHODS AND RESULTS: The influence of different comorbid conditions on left ventricular remodeling, improvement in New York Heart Association (NYHA) functional class, hospitalizations for heart failure, and all-cause mortality after CRT implantation was analyzed in 172 consecutive patients (mean age 71 ± 9 y), implanted from October 2008 to April 2011 in a single tertiary care hospital. During mean follow-up of 18 ± 9 months, 21 patients died and 57 were admitted for heart failure. Left ventricular remodeling and improvement in NYHA functional class were independent from comorbidity burden. However, diabetes mellitus (hazard ratio [HR] 3.45, 95% confidence interval [CI] 1.24-9.65) and chronic kidney disease (HR 3.11, 95% CI 1.10-8.81) were predictors of all-cause mortality, and the presence of chronic obstructive pulmonary disease (HR 1.89, 95% CI 1.02-3.53) was independently associated with heart failure admissions. Importantly, those 3 comorbid conditions had an additive negative impact on survival and heart failure admissions, even in patients with reverse left ventricular remodeling. CONCLUSIONS: Reverse ventricular remodeling and improvement in functional status after CRT implantation are independent from comorbidity burden. However, comorbid conditions remain important predictors of all-cause mortality and heart failure admissions.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Remodelação Ventricular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Comorbidade , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
13.
Front Cardiovasc Med ; 9: 839853, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402567

RESUMO

Background and Case: This case report exemplifies the clinical application of non-invasive photoplethysmography (PPG)-based rhythm monitoring in the awakening mobile health (mHealth) era to detect symptomatic and asymptomatic paroxysmal atrial fibrillation (AF) in a cryptogenic stroke patient. Despite extensive diagnostic workup, the etiology remains unknown in one out of three ischemic strokes (i.e., cryptogenic stroke). Prolonged cardiac monitoring can reveal asymptomatic atrial fibrillation in up to one-third of this population. This case report describes a cryptogenic stroke patient who received prolonged cardiac monitoring with an insertable cardiac monitor (ICM) as standard of care. In the context of a clinical study, the patient simultaneously monitored his heart rhythm with a PPG-based smartphone application. AF was detected simultaneously on both the ICM and smartphone application after three days of monitoring. Similar AF burden was detected during follow-up (five episodes, median duration of 28 and 34 h on ICM and mHealth, respectively, p = 0.5). The detection prompted the initiation of oral anticoagulation and AF catheter ablation procedure. Conclusion: This is the first report of the cryptogenic stroke patient in whom PPG-based mHealth was able to detect occurrence and burden of the symptomatic and asymptomatic paroxysmal AF episodes with similar precision as ICM. It accentuates the potential role of PPG-based mHealth in prolonged cardiac rhythm monitoring in cryptogenic stroke patients.

14.
Front Cardiovasc Med ; 9: 848914, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35498000

RESUMO

Aim: This paper presents the preliminary results from the ongoing REMOTE trial. It aims to explore the opportunities and hurdles of using insertable cardiac monitors (ICMs) and photoplethysmography-based mobile health (PPG-based mHealth) using a smartphone or smartwatch to detect atrial fibrillation (AF) in cryptogenic stroke and transient ischemic attack (TIA) patients. Methods and Results: Cryptogenic stroke or TIA patients (n = 39) received an ICM to search for AF and were asked to use a blinded PPG-based mHealth application for 6 months simultaneously. They were randomized to smartphone or smartwatch monitoring. In total, 68,748 1-min recordings were performed using PPG-based mHealth. The number of mHealth recordings decreased significantly over time in both smartphone and smartwatch groups (p < 0.001 and p = 0.002, respectively). Insufficient signal quality was more frequently observed in smartwatch (43.3%) compared to smartphone recordings (17.8%, p < 0.001). However, when looking at the labeling of the mHealth recordings on a patient level, there was no significant difference in signal quality between both groups. Moreover, the use of a smartwatch resulted in significantly more 12-h periods (91.4%) that were clinically useful compared to smartphone users (84.8%) as they had at least one recording of sufficient signal quality. Simultaneously, continuous data was collected from the ICMs, resulting in approximately 6,660,000 min of data (i.e., almost a 100-fold increase compared to mHealth). The ICM algorithm detected AF and other cardiac arrhythmias in 10 and 19 patients, respectively. However, these were only confirmed after adjudication by the remote monitoring team in 1 (10%) and 5 (26.3%) patients, respectively. The confirmed AF was also detected by PPG-based mHealth. Conclusion: Based on the preliminary observations, our paper illustrates the potential as well as the limitations of PPG-based mHealth and ICMs to detect AF in cryptogenic stroke and TIA patients in four elements: (i) mHealth was able to detect AF in a patient in which AF was confirmed on the ICM; (ii) Even state-of-the-art ICMs yielded many false-positive AF registrations; (iii) Both mHealth and ICM still require physician revision; and (iv) Blinding of the mHealth results impairs compliance and motivation.

15.
JACC Cardiovasc Imaging ; 15(1): 1-13, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34274270

RESUMO

OBJECTIVES: This study aimed to investigate mitral annular dynamics in atrial fibrillation (AF) and after sinus rhythm restoration, and to assess the relationship between annular dynamics and mitral regurgitation (MR). BACKGROUND: AF can be associated with MR that improves after sinus rhythm restoration. Mechanisms underlying this atrial functional MR (AFMR) are ill-understood and generally attributed to left atrial remodeling. METHODS: Fifty-three patients with persistent AF and normal left ventricular ejection fraction were prospectively examined by means of 3-dimensional transesophageal echocardiography before, immediately after, and 6 weeks after electric cardioversion to sinus rhythm. Annular motion was assessed during AF and in sinus rhythm with the use of 3-dimensional analysis software, and the relationship with MR severity was explored. RESULTS: During AF and immediately after sinus rhythm restoration, the mitral annulus behaved relatively adynamically, with an overall change in annular area of 10.3% (95% CI: 8.7%-11.8%) and 12.2% (95% CI: 10.6%-13.8%), respectively. At follow-up, a significant increase in annular dynamics (19.0%; 95% CI: 17.4%-20.6%; P < 0.001) was observed, owing predominantly to an increase in presystolic contraction (P < 0.001). The effective regurgitant orifice area decreased from 0.15 cm2 (0.10-0.23 cm2) during AF to 0.09 cm2 (0.05-0.12 cm2) at follow-up (P < 0.001) in the total cohort, and from 0.27 (0.23-0.33) to 0.16 (0.12-0.29) in the subgroup with effective regurgitant orifice area (EROA) ≥0.20 cm2. The change in presystolic annular motion was the only independent determinant of the decrease in MR severity (P = 0.027), by optimizing annular-leaflet imbalance. Patients with more pronounced blunting of presystolic dynamics had a higher EROA (P < 0.001), because of a lower total-to-closed leaflet area ratio (P < 0.001) at each point in time. This ratio was the strongest independent determinant of AFMR severity (adjusted P = 0.003). CONCLUSIONS: Mitral annular dynamics are impaired in AF, with blunted presystolic narrowing that contributes to AFMR. Sinus rhythm restoration allows gradual recovery of presystolic annular dynamics. Improved annular dynamics decrease AFMR severity by optimizing annular-leaflet imbalance, regardless of LA remodeling.


Assuntos
Fibrilação Atrial , Insuficiência da Valva Mitral , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda
16.
J Magn Reson Imaging ; 34(6): 1243-50, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22102557

RESUMO

Acute coronary syndromes (ACS) continue to be the most common morbid condition of industrialized nations. The advent of and technical improvements in revascularization and medical therapy have led to a steady decline in mortality rates. However, many patients who suffer unstable angina or myocardial infarction require further testing and risk stratification to guide therapeutic selection and prognosis assignment. Myocardial edema imaging with cardiac magnetic resonance (CMR) affords the ability to define the amount of myocardium at risk, refine estimates of prognosis and provide guidance for therapies with excellent sensitivity compared with standard clinical markers. This review will discuss the rationale for edema imaging, how it is performed using CMR, and potential clinical applications.


Assuntos
Síndrome Coronariana Aguda/patologia , Edema/patologia , Imageamento por Ressonância Magnética , Miocárdio/patologia , Síndrome Coronariana Aguda/fisiopatologia
17.
Pacing Clin Electrophysiol ; 34(5): 604-11, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21276023

RESUMO

BACKGROUND: The relationship between QRS narrowing and response to cardiac resynchronization therapy (CRT) has been controversial. OBJECTIVE: We sought to analyze the relationship between QRS narrowing and reverse remodeling in patients undergoing CRT, taking into account potential confounders including pre-CRT QRS duration and underlying QRS morphology. METHODS: We reviewed pre- and postimplant electrocardiograms and echocardiograms in a cohort of 233 patients undergoing the new implantation of a CRT device between December 2001 and September 2006. For inclusion in the final cohort, patients had New York Heart Association classes II-IV heart failure, left ventricular ejection fraction (LVEF) ≤ 40%, and QRS duration ≥120 ms. Response to CRT was defined as a reduction in left ventricular end-systolic volume (LVESV) of ≥10%. A multivariate model was constructed to determine the relationship between QRS change and response to CRT. RESULTS: Patients with QRS narrowing had significantly greater reductions in left ventricular end-diastolic volume (LVEDV) (mL) (-26.5 ± 52.5 vs -4.8 ± 44.0, P = 0.002) and LVESV (mL) (-34.0 ± 55.5 vs -9.9 ± 45.8, P = 0.002) and improvement in LVEF (%) (8.9 ± 12.8 vs 4.5 ± 9.0, P = 0.007) than patients without narrowing. In univariate analysis, female gender (P = 0.0002), percent QRS narrowing from baseline (P = 0.008), lack of nitrate (P≤0.0001) and antiarrhythmic medication use (P = 0.01), lack of a nonspecific intraventricular conduction delay (=0.02), nonischemic cardiomyopathy (P = 0.003), and lower pre-CRT LVEDV (P = 0.006) and LVESV [P = 0.01]) were associated with responders. In a multivariate model, QRS narrowing, indexed to the baseline QRS duration, remained strongly associated with response (odds ratio 0.08 [0.01-0.56], P = 0.01). CONCLUSIONS: After adjusting for potential confounders, QRS narrowing, indexed to baseline QRS duration, is associated with enhanced reverse ventricular remodeling following CRT.


Assuntos
Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia , Eletrocardiografia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Remodelação Ventricular/fisiologia , Arritmias Cardíacas/diagnóstico por imagem , Biomarcadores/análise , Distribuição de Qui-Quadrado , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Modelos Logísticos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico
18.
Ann Noninvasive Electrocardiol ; 16(2): 165-71, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21496167

RESUMO

BACKGROUND: QRS fragmentation (fQRS) has been shown to be a marker of scar in patients with left ventricular dysfunction. Whether fQRS is associated with progressive left ventricular remodeling and increased mortality in patients receiving cardiac resynchronization therapy (CRT) is unclear. METHODS: We reviewed the preimplant and follow-up echocardiograms in 233 patients undergoing the new implantation of a CRT device between December 2001 and November 2006. Patients were included if they had a pre-CRT ECG with appropriate filter settings (filter 0.16-100 or 0.16-150 Hz, 25 mm/s, 10 mm/mV), a left ventricular ejection fraction (LVEF) ≤40%, and New York Heart Association class II-IV symptoms on standard medical therapy. The 12-lead electrocardiogram (ECG) was interpreted by two blinded reviewers for the presence of fQRS. Remodeling end points, including changes in LVEF and left ventricular end-diastolic (LVEDV) and systolic (LVESV) volumes, were compared between patients with and without contiguous fQRS, and an assessment of all-cause mortality was made. RESULTS: Two hundred thirty-two patients met inclusion criteria, of which 50 demonstrated fQRS in contiguous leads. There was no difference in improvement in LVEF (%) (7.9 ± 12.9 vs 6.8 ± 11.0, P = 0.60) or reduction in LVEDV (mL) (-30.1 ± 57.2 vs -15.7 ± 47.6) or LVESV (mL) (-33.7 ± 58.1 vs -22.7 ± 50.6, P = 0.40) between patients with and without contiguous fQRS. At a mean follow-up of 4.4 ± 1.9 years, there were a total of 89 deaths, 22 (44.0%) in patients with contiguous fQRS and 67 (36.8%) without (log rank P = 0.31). CONCLUSIONS: QRS fragmentation is not a predictor of progressive ventricular remodeling or mortality in heart failure patients undergoing CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Ecocardiografia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Remodelação Ventricular
19.
Heart ; 107(18): 1503-1509, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34415852

RESUMO

OBJECTIVES: Atrial secondary mitral regurgitation (ASMR) is a clinically distinct form of Carpentier type I mitral regurgitation (MR), rooted in excessive atrial and mitral annular dilation in the absence of left ventricular dysfunction. Mitral valve annuloplasty (MVA) is expected to provide a more durable solution for ASMR than for ventricular secondary MR (VSMR). Yet data on MR recurrence and outcome after MVA for ASMR are scarce. This study sought to investigate surgical outcomes and repair durability in patients with ASMR, as compared with a contemporary group of patients with VSMR. METHODS: Clinical and echocardiographic data from consecutive patients who underwent MVA to treat ASMR or VSMR in an academic centre were retrospectively analysed. Patient characteristics, operative outcomes, time to recurrence of ≥moderate MR and all-cause mortality were compared between patients with ASMR versus VSMR. RESULTS: Of the 216 patients analysed, 97 had ASMR opposed to 119 with VSMR and subvalvular leaflet tethering. Patients with ASMR were typically female (68.0% vs 33.6% in VSMR, p<0.001), with a history of atrial fibrillation (76.3% vs 33.6% in VSMR, p<0.001), paralleling a larger left atrial size (p<0.033). At a median follow-up of 3.3 (IQR 1.0-7.3) years, recurrence of ≥moderate MR was significantly lower in ASMR versus VSMR (7% vs 25% at 2 years, overall log-rank p=0.001), also when accounting for all-cause death as competing risk (subdistribution HR 0.50 in ASMR, 95% CI 0.29 to 0.88, p=0.016). Moreover, ASMR was associated with better overall survival compared with VSMR (adjusted HR 0.43 95% CI 0.22 to 0.82, p=0.011), independent from baseline European System for Cardiac Operative Risk Evaluation II surgical risk score. CONCLUSION: Prognosis following MVA to treat ASMR is better, compared with VSMR as reflected by lower all-cause mortality and MR recurrence. Early distinction of secondary MR towards underlying ventricular versus atrial disease has important therapeutic implications.


Assuntos
Átrios do Coração/diagnóstico por imagem , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Função Ventricular Esquerda/fisiologia , Idoso , Ecocardiografia , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
20.
J Cardiovasc Magn Reson ; 12: 16, 2010 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-20307275

RESUMO

Truncus arteriosus (TA) is a rare congenital condition defined as a single arterial vessel arising from the heart that gives origin to the systemic, pulmonary and coronary circulations. We discuss the unique case of a 28 year-old female patient with unrepaired TA and interruption of the aortic arch who underwent cardiovascular magnetic resonance (CMR).


Assuntos
Anormalidades Múltiplas , Aorta Torácica/anormalidades , Aorta Torácica/patologia , Angiografia por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Persistência do Tronco Arterial/diagnóstico , Aborto Espontâneo , Adulto , Aorta Torácica/cirurgia , Meios de Contraste , Aconselhamento , Feminino , Gadolínio DTPA , Humanos , Gravidez , Persistência do Tronco Arterial/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA