Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Eur Spine J ; 33(6): 2304-2313, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38635086

RESUMO

BACKGROUND CONTEXT: Studies have shown biomechanical superiority of cervical pedicle screw placement over other techniques. However, accurate placement is challenging due to the inherent risk of neurovascular complications. Navigation technology based on intraoperative 3D imaging allows highly accurate screw placement, yet studies specifically investigating screw placement in patients with traumatic atlantoaxial injuries are scarce. The aim of this study was to compare atlantoaxial screw placement as treatment of traumatic instabilities using iCT-based navigation or fluoroscopic-guidance with intraoperative 3D control scans. METHODS: This was a retrospective review of patients with traumatic atlantoaxial injuries treated operatively with dorsal stabilization of C1 and C2. Patients were either assigned to the intraoperative navigation or fluoroscopic-guidance group. Screw accuracy, procedure time, and revisions were compared. RESULTS: Seventy-eight patients were included in this study with 51 patients in the navigation group and 27 patients in the fluoroscopic-guidance group. In total, 312 screws were placed in C1 and C2. Screw accuracy was high in both groups; however, pedicle perforations > 1 mm occurred significantly more often in the fluoroscopic-guidance group (P = 0.02). Procedure time was on average 23 min shorter in the navigation group (P = 0.02). CONCLUSIONS: This study contributes to the available data showing that navigated atlantoaxial screw placement proves to be feasible as well as highly accurate compared to the fluoroscopic-guidance technique without prolonging the time needed for surgery. When comparing these data with other studies, the application of different classification systems for assessment of screw accuracy should be considered.


Assuntos
Articulação Atlantoaxial , Vértebras Cervicais , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Fluoroscopia/métodos , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Articulação Atlantoaxial/cirurgia , Articulação Atlantoaxial/diagnóstico por imagem , Articulação Atlantoaxial/lesões , Cirurgia Assistida por Computador/métodos , Parafusos Ósseos , Parafusos Pediculares , Idoso , Traumatismos da Coluna Vertebral/cirurgia , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Adulto Jovem , Resultado do Tratamento , Instabilidade Articular/cirurgia , Instabilidade Articular/diagnóstico por imagem
2.
BMC Musculoskelet Disord ; 24(1): 752, 2023 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-37742007

RESUMO

BACKGROUND: Studies have shown that pedicle screw placement using navigation can potentially reduce radiation exposure of surgical personnel compared to conventional methods. Spinal navigation is based on an interaction of a navigation software and 3D imaging. The 3D image data can be acquired using different imaging modalities such as iCT and CBCT. These imaging modalities vary regarding acquisition technique and field of view. The current literature varies greatly in study design, in form of dose registration, as well as navigation systems and imaging modalities analyzed. Therefore, the aim of this study was a standardized comparison of three navigation and imaging system combinations in an experimental setting in an artificial spine model. METHODS: In this experimental study dorsal instrumentation of the thoracolumbar spine was performed using three imaging/navigation system combinations. The system combinations applied were the iCT/Curve, cCBCT/Pulse and oCBCT/StealthStation. Referencing scans were obtained with each imaging modality and served as basis for the respective navigation system. In each group 10 artificial spine models received bilateral dorsal instrumentation from T11-S1. 2 referencing and control scans were acquired with the CBCTs, since their field of view could only depict up to five vertebrae in one scan. The field of view of the iCT enabled the depiction of T11-S1 in one scan. After instrumentation the region of interest was scanned again for evaluation of the screw position, therefore only one referencing and one control scan were obtained. Two dose meters were installed in a spine bed ventral of L1 and S1. The dose measurements in each location and in total were analyzed for each system combination. Time demand regarding screw placement was also assessed for all system combinations. RESULTS: The mean radiation dose in the iCT group measured 1,6 ± 1,1 mGy. In the cCBCT group the mean was 3,6 ± 0,3 mGy and in the oCBCT group 10,3 ± 5,7 mGy were measured. The analysis of variance (ANOVA) showed a significant (p < 0.0001) difference between the three groups. The multiple comparisions by the Kruskall-Wallis test showed no significant difference for the comparison of iCT and cCBCT (p1 = 0,13). Significant differences were found for the direct comparison of iCT and oCBCT (p2 < 0,0001), as well as cCBCT and oCBCT (p3 = 0,02). Statistical analysis showed that significantly (iCT vs. oCBCT p = 0,0434; cCBCT vs. oCBCT p = 0,0083) less time was needed for oCBCT based navigated pedicle screw placement compared to the other system combinations (iCT vs. cCBCT p = 0,871). CONCLUSION: Under standardized conditions oCBCT navigation demanded twice as much radiation as the cCBCT for the same number of scans, while the radiation exposure measured for the iCT and cCBCT for one scan was comparable. Yet, time effort was significantly less for oCBCT based navigation. However, for transferability into clinical practice additional studies should follow evaluating parameters regarding feasibility and clinical outcome under standardized conditions.


Assuntos
Parafusos Pediculares , Exposição à Radiação , Humanos , Diagnóstico por Imagem , Exposição à Radiação/prevenção & controle , Análise de Variância , Frequência Cardíaca
3.
Knee Surg Sports Traumatol Arthrosc ; 31(7): 2870-2876, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36454291

RESUMO

PURPOSE: Patellar maltracking caused by a rupture of the medial patellofemoral ligament (MPFL) can be improved by MPFL reconstruction (MPFL-R) with a tendon graft. Nonresorbable suture tape (FiberTape®, FT) is possibly becoming an option to tendon grafts for MPFL-R. Patella-side fixation of FT can be performed with suture anchors or via soft-tissue fixation. The aim of this study was to investigate patellar tracking considering soft-tissue-based and anchor-based patella-side fixation techniques. METHODS: In eight fresh-frozen human knee joint specimens (m/f 4/4; age 75 ± 10 years), the MPFL was identified, and a rupture was placed near the femoral insertion site. In the study group (SG; 4 knees), soft-tissue fixation of the FT was performed at the medial patellar retinaculum; in the control group (CG; 4 knees), FT was fixed at the patella via suture anchors. For native MPFL (nMPFL), ruptured ("injured") MPFL (iMPFL) and reconstructed MPFL (FT-MPFL-SG, respectively, FT-MPFL-CG) cone beam CT scans were performed in 15°, 30°, and 45° of knee joint flexion. Patellar tracking was assessed using the radiological parameters patellar tilt (PT), congruence angle (CA) and posterior patellar edge-trochlear groove ratio (PTR). RESULTS: All recorded radiological parameters increased, respectively, decreased in the CG and SG from the nMPFL to the iMPFL state. After MPFL-R, all parameters normalized when compared to the intact state (nMPFL), regardless of patella-side fixation technique. All investigated parameters of patellotrochlear alignment were positively, respectively, negatively significantly (p < 0.05) correlated throughout all evaluated conditions (nMPFL, iMPFL, FT-MPFL-SG, FT-MPFL-CG). CONCLUSION: MPFL-R with a nonresorbable suture tape can normalize patellar maltracking in fresh-frozen human knee joint specimens in earlier degrees of knee joint flexion independent of patella-side fixation technique. The investigated parameters of patellotrochlear alignment correlate with each other.


Assuntos
Luxação Patelar , Articulação Patelofemoral , Humanos , Idoso , Idoso de 80 Anos ou mais , Patela/cirurgia , Articulação Patelofemoral/cirurgia , Cadáver , Articulação do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Suturas , Luxação Patelar/cirurgia
4.
Knee Surg Sports Traumatol Arthrosc ; 31(1): 292-298, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35994076

RESUMO

PURPOSE: Reconstruction of the medial patellofemoral ligament (MPFL-R) with nonresorbable suture tape (FiberTape®, FT) is becoming popular. Patella-side fixation of the FT can be performed with suture anchors or via soft-tissue fixation. The aim of this study was to investigate whether patella-side soft-tissue fixation can achieve equivalent primary stability compared to suture-anchor fixation. METHODS: In ten human, fresh-frozen knee joint specimens (m/f 6/4; age 74 ± 9 a), the MPFL was identified and dissected near the femoral insertion site. In five knee joints, the MPFL-R using FT was performed with soft-tissue fixation at the patella (study group; SG), and in five knee joints, the FT was fixed via suture anchors (control group, CG). All reconstructions were evaluated until load to failure of the patella-side fixation with a displacement rate of 200 mm/min. RESULTS: The mean maximum load to failure in the SG was 395.3 ± 57.9 N. All reconstructions failed by complete tearing off the medial patellar retinaculum from its medial patellar margin, but fixation of the FT remained stable. In the CG, the mean maximum load to failure was 239.4 ± 54.5 N and was significantly different compared to the SG (p = 0.04). All reconstructions failed via pullout of the suture anchors. Stiffness and elongation did not differ between the groups, and no failure of the FT was observed in any of the specimens. CONCLUSION: Primary stability of soft-tissue MPFL-R using FT was superior to suture-anchor fixation. Both fixation techniques provided sufficient primary stability, superior to previously reported native MPFL tensile strengths. MPFL-R with FT could be a possible alternative procedure for MPFL-R, eliminating potential complications due to autologous tendon graft harvesting.


Assuntos
Articulação Patelofemoral , Âncoras de Sutura , Humanos , Idoso , Idoso de 80 Anos ou mais , Articulação Patelofemoral/cirurgia , Fixação de Tecidos , Patela/cirurgia , Articulação do Joelho , Ligamentos Articulares/cirurgia , Suturas
5.
BMC Med Imaging ; 22(1): 181, 2022 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261814

RESUMO

BACKGROUND: In syndesmotic injuries, incorrect reduction leads to early arthrosis of the ankle joint. Being able to analyze the reduction result is therefore crucial for obtaining an anatomical reduction. Several studies that assess fibular rotation in the incisura have already been published. The aim of the study was to validate measurement methods that use cone beam computed tomography imaging to detect rotational malpositions of the fibula in a standardized specimen model. METHODS: An artificial Maisonneuve injury was created on 16 pairs of fresh-frozen lower legs. Using a stable instrument, rotational malpositions of 5, 10, and 15° internal and external rotation were generated. For each malposition of the fibula, a cone beam computed tomography scan was performed. Subsequently, the malpositions were measured and statistically evaluated with t-tests using two measuring methods: angle (γ) at 10 mm proximal to the tibial joint line and the angle (δ) at 6 mm distal to the talar joint line. RESULTS: Rotational malpositions of ≥ 10° could be reliably displayed in the 3D images using the measuring method with angle δ. For angle γ significant results could only be displayed for an external rotation malposition of 15°. CONCLUSIONS: Clinically relevant rotational malpositions of the fibula in comparison with an uninjured contralateral side can be reliably detected using intraoperative 3D imaging with a C-arm cone beam computed tomography. This may allow surgeons to achieve better reduction of fibular malpositions in the incisura tibiofibularis.


Assuntos
Traumatismos do Tornozelo , Fíbula , Humanos , Fíbula/diagnóstico por imagem , Fíbula/lesões , Traumatismos do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/diagnóstico por imagem , Tíbia , Tomografia Computadorizada de Feixe Cônico
6.
J Digit Imaging ; 35(3): 514-523, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35146612

RESUMO

Previous studies have demonstrated a frequent occurrence of screw/K-wire malpositioning during surgical fracture treatment under 2D fluoroscopy and a correspondingly high revision rate as a result of using intraoperative 3D imaging. In order to facilitate and accelerate the diagnosis of implant malpositioning in 3D data sets, this study investigates two versions of an implant detection software for mobile 3D C-arms in terms of their detection performance based on comparison with manual evaluation. The 3D data sets of patients who had received surgical fracture treatment at five anatomical regions were extracted from the research database. First, manual evaluation of the data sets was performed, and the number of implanted implants was assessed. For 25 data sets, the time required by four investigators to adjust each implant was monitored. Subsequently, the evaluation was performed using both software versions based on the following detection parameters: true-positive-rate, false-negative-rate, false-detection-rate and positive predictive value. Furthermore, the causes of false positive and false negative detected implants depending on the anatomical region were investigated. Two hundred fourteen data sets with overall 1767 implants were included. The detection parameters were significantly improved (p<.001) from version 1 to version 2 of the implant detection software. Automatic evaluation required an average of 4.1±0.4 s while manual evaluation was completed in 136.15±72.9 s (p<.001), with a statistically significant difference between experienced and inexperienced users (p=.005). In summary, version 2 of the implant detection software achieved significantly better results. The time saved by using the software could contribute to optimizing the intraoperative workflow.


Assuntos
Imageamento Tridimensional , Software , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos
7.
Medicina (Kaunas) ; 58(8)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36013578

RESUMO

Background and Objectives: Navigated pedicle screw placement is becoming increasingly popular, as it has been shown to reduce the rate of screw misplacement. We present our intraoperative workflow and initial experience in terms of safety, efficiency, and clinical feasibility with a novel system for a 3D C-arm cone beam computed-tomography-based navigation of thoracolumbar pedicle screws. Materials and Methods: The first 20 consecutive cases of C-arm cone beam computed-tomography-based percutaneous pedicle screw placement using a novel navigation system were included in this study. Procedural data including screw placement time and patient radiation dose were prospectively collected. Final pedicle screw accuracy was assessed using the Gertzbein-Robbins grading system. Results: In total, 156 screws were placed. The screw accuracy was 94.9%. All the pedicle breaches occurred on the lateral pedicle wall, and none caused clinical complications. On average, a time of 2:42 min was required to place a screw. The mean intraoperative patient radiation exposure was 7.46 mSv. Conclusions: In summary, the investigated combination of C-arm CBCT-based navigation proved to be easy to implement and highly reliable. It facilitates the accurate and efficient percutaneous placement of pedicle screws in the thoracolumbar spine. The careful use of intraoperative imaging maintains the intraoperative radiation exposure to the patient at a moderate level.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Humanos , Imageamento Tridimensional/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Cirurgia Assistida por Computador/métodos
8.
J Digit Imaging ; 34(4): 788-797, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34327626

RESUMO

In clinical routine, wound documentation is one of the most important contributing factors to treating patients with acute or chronic wounds. The wound documentation process is currently very time-consuming, often examiner-dependent, and therefore imprecise. This study aimed to validate a software-based method for automated segmentation and measurement of wounds on photographic images using the Mask R-CNN (Region-based Convolutional Neural Network). During the validation, five medical experts manually segmented an independent dataset with 35 wound photographs at two different points in time with an interval of 1 month. Simultaneously, the dataset was automatically segmented using the Mask R-CNN. Afterwards, the segmentation results were compared, and intra- and inter-rater analyses performed. In the statistical evaluation, an analysis of variance (ANOVA) was carried out and dice coefficients were calculated. The ANOVA showed no statistically significant differences throughout all raters and the network in the first segmentation round (F = 1.424 and p > 0.228) and the second segmentation round (F = 0.9969 and p > 0.411). The repeated measure analysis demonstrated no statistically significant differences in the segmentation quality of the medical experts over time (F = 6.05 and p > 0.09). However, a certain intra-rater variability was apparent, whereas the Mask R-CNN consistently provided identical segmentations regardless of the point in time. Using the software-based method for segmentation and measurement of wounds on photographs can accelerate the documentation process and improve the consistency of measured values while maintaining quality and precision.


Assuntos
Redes Neurais de Computação , Software , Humanos , Processamento de Imagem Assistida por Computador
9.
Arthroscopy ; 36(1): 178-185, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31864574

RESUMO

PURPOSE: To compare and evaluate knee laxity and functional outcomes between autologous bone graft and silicate-substituted calcium phosphate (Si-CaP) in the treatment of tunnel defects in 2-stage revision anterior cruciate ligament reconstruction (ACLR). METHODS: This prospective, randomized controlled trial was conducted between 2012 and 2015 with a total of 40 patients who underwent 2-stage revision ACLR. The tunnels were filled with autologous iliac crest cancellous bone graft in 20 patients (control group) and with Si-CaP in the other 20 patients (intervention group). After a minimum follow-up period of 2 years, functional outcomes were assessed by KT-1000 arthrometry (side-to-side [STS] difference), the Tegner score, the Lysholm score, and the International Knee Documentation Committee score. RESULTS: A total of 37 patients (follow-up rate, 92.5%) with an average age of 31 years were followed up for 3.4 years (range, 2.2-5.5 years). The KT-1000 measurement did not show any STS difference between the bone graft group (0.9 ± 1.5 mm) and the Si-CaP group (0.7 ± 2.0 mm) (P = .731). One patient in the intervention group (5%) had an STS difference greater than 5 mm. Both groups showed significant improvements in the Tegner score, Lysholm score, and International Knee Documentation Committee score from preoperative assessment to final follow-up (P ≤ .002), without any difference between the 2 groups (P ≥ .396). Complications requiring revision occurred in 4 control patients (22%) and in 2 patients in the intervention group (11%) (P = .660). No complications in relation to Si-CaP were observed. CONCLUSIONS: Equivalent knee laxity and clinical function outcomes were noted 3 years after surgery in both groups of patients. Si-CaP bone substitute is therefore a safe alternative to autologous bone graft for 2-stage ACLR. LEVEL OF EVIDENCE: Level I, prospective, randomized controlled clinical trial.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Transplante Ósseo/métodos , Compostos de Cálcio/farmacologia , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Silicatos/farmacologia , Adulto , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/diagnóstico , Lesões do Ligamento Cruzado Anterior/fisiopatologia , Autoenxertos , Substitutos Ósseos , Feminino , Seguimentos , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/etiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Estudos Prospectivos , Radiografia , Reoperação , Fatores de Tempo , Resultado do Tratamento
10.
J Digit Imaging ; 33(5): 1136-1143, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32632648

RESUMO

The aim of our study was to evaluate whether software-based artifact reduction can achieve an improved image quality, using intraoperative 3D imaging in spinal surgery. A total of 49 intraoperative 3D image datasets of patients, who underwent surgery with pedicle screw placement, were retrospectively evaluated. The visibility of anatomical structures and the diameter of the pedicle screws were examined, with and without the application of the artifact reduction software. All software prototypes can improve the visibility of anatomical structures (P < 0.01), except MAR (metal artifact reduction) combined with IRIS (iterative reconstruction in image space) (P = 0.04). The algorithms MAR and MAR-2 can reduce the blooming artifacts significantly (P < 0.01), but SL (Shepp & Logan) cannot (P = 0.08-0.988). In summary, software-based artifact reduction for intraoperative 3D datasets can improve the current image quality. Additional information regarding the implant placement and the fracture reduction is therefore generated for the surgeon.


Assuntos
Artefatos , Imageamento Tridimensional , Algoritmos , Tomografia Computadorizada de Feixe Cônico , Humanos , Estudos Retrospectivos , Software
11.
BMC Musculoskelet Disord ; 20(1): 534, 2019 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-31722696

RESUMO

BACKGROUND: The aim of the study was to evaluate the impact of reduction quality, using intraoperative 3D imaging, on quality of life and functional outcome in the operative treatment of tibial plafond fractures. METHODS: A group of patients with tibial plafond fractures was re-examined. The operative treatment was performed between September 2001 and October 2011. The follow-up examination was at least 2 years after the final surgical procedure. Final reduction result was assessed intraoperatively using a mobile 3D C-arm. A categorization with regard to descriptive parameters as well as type and size of joint surface irregularities was performed. Follow-up results were evaluated using: Olerud and Molander (O & M) score, Short-Form-36 (SF-36) score, movement deficit, Kellgren and Lawrence grade of osteoarthritis, and pain intensity. RESULTS: 34 patients with operatively treated tibial plafond fracture could be re-examined. Reduction quality had the greatest influence on functional result measured by the O & M score (p = 0.001) and the PCS domain of the SF-36 score (p = 0.018). Significant differences with regard to O & M score (p = 0.000), SF-36 score (p = 0.001 to p = 0.02; without MCS domain), movement deficit (p = 0.001), grade of osteoarthritis (p = 0.005) and pain (p = 0.001) could be verified under consideration of the reduction quality. The group with the anatomically more accurate reduction also showed a better result for clinical follow-up and quality of life. Furthermore, it is not the type of joint surface irregularity that is always decisive, but rather the size. CONCLUSIONS: Despite other relevant factors, it appears that reduction quality -which can be analyzed with intraoperative 3D imaging- plays the most important role in postoperative quality of life and functional outcome. Corrections should therefore be performed on joint surface irregularities with a size above 2 mm.


Assuntos
Fixação de Fratura , Consolidação da Fratura , Qualidade de Vida , Fraturas da Tíbia/cirurgia , Adulto , Tomografia Computadorizada de Feixe Cônico , Feminino , Fixação de Fratura/efeitos adversos , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Fraturas da Tíbia/psicologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Arch Orthop Trauma Surg ; 139(11): 1543-1549, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30989412

RESUMO

INTRODUCTION: The aim of this study was to evaluate a radiographic measurement method for assessment of overlengthening of the MoPyC radial head prosthesis. MATERIALS AND METHODS: Seven cadaver specimens were studied in ten stages: native specimen (1), radial head resection (2), and implantation of the MoPyC radial head prostheses (Bioprofile, Tornier, Montbonnot-Saint-Martin, France) in four increasing length (correct length, overlengthening of 1.5 mm, 3 mm, and 5 mm) with an intact medial collateral ligament (MCL 3-6) and following transection of the MCL (7-10). The radiographic measurement method according to Athwal et al. was evaluated to detect overlengthening. Statistical analysis included calculation of the diagnostic accuracy of the radiographic method. RESULTS: The radiographic measurement method correctly determined the size of the radial head prosthesis within ± 1 mm in 224 of 336 scenarios (67%) and within ± 2 mm in 320 of 336 scenarios (95%). With a threshold value of ≥ 1 mm, the overall diagnostic sensitivity for detecting overlengthening when it was present and was 90% and the specificity was 79%. The sensitivity was higher with increasing size of the prosthesis: in cases with overlengthening of 1.5 mm, the sensitivity was 76%, with an overlengthening of 3 mm, the sensitivity was 95%, and with an overlengthening of 5 mm, the sensitivity was 100%. CONCLUSION: The radiographic measurement method of Athwal et al. can be used to estimate and to diagnose the magnitude overlengthening of the MoPyC radial head prosthesis. However, the sensitivity is limited (76%) in cases with a small amount of overlengthening of 1.5 mm.


Assuntos
Articulação do Cotovelo , Prótese de Cotovelo , Implantação de Prótese , Radiografia , Rádio (Anatomia) , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Humanos , Desenho de Prótese , Implantação de Prótese/métodos , Implantação de Prótese/normas , Radiografia/métodos , Radiografia/normas , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia
13.
J Digit Imaging ; 31(1): 74-83, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28799133

RESUMO

Medical images are essential in modern traumatology and orthopedic surgery. Access to images is often cumbersome due to a limited number of workstations. Moreover, due to the tremendous increase of data, the time to review or to communicate images has also become limited. One approach to overcome these problems is to make use of modern mobile devices, like tablet computers, to facilitate image access and associated workflows. Ten orthopedic surgeons were equipped with an Apple iPad mini 2 and specialized viewing software for medical images. The surgeons were able to send images from a workstation onto the tablets or to search for patient images directly. The software enabled the physicians to share images, annotated key slices, and messages instantly with their colleagues. The surgeons carried the tablets within or in the periphery of the hospital. The participants evaluated the software by means of daily questionnaires. Data was collected for a period of 9 months. Nearly 25 images were viewed in total by the surgeons per day. The tablet viewer was used for accessing approximately 30% of these images. On average, the surgeons were asked 1.7 times per day by a colleague for a second opinion. They used the tablets in approximately 29% of these cases. Furthermore, the mean time for accessing images was significantly lower using mobile software compared to conventional methods. Tablet computers can play a vital role for image access and communication in the daily routine of an orthopedic surgeon. Mobile image access is an important aspect for surgeons, especially in larger facilities, to facilitate and accelerate the clinical workflows.


Assuntos
Computadores de Mão , Cirurgiões Ortopédicos , Ortopedia , Sistemas de Informação em Radiologia , Telerradiologia/métodos , Humanos , Estudos Prospectivos
14.
Arch Orthop Trauma Surg ; 138(4): 487-493, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29322319

RESUMO

INTRODUCTION: In operative treatment of distal radius fractures satisfying outcome mainly relies on anatomical fracture reduction and correct implant placement. Examination with two-dimensional fluoroscopy may not provide reliable information about this. The aim of this study was to determine the effectiveness of additional intraoperative three-dimensional imaging in the operative treatment of comminuted distal radius fractures. MATERIALS AND METHODS: From August 2001 to June 2015, patients with a distal radius fracture who were treated operatively and received intraoperative three-dimensional scan were included. The findings of the three-dimensional scan were documented by the operative surgeon and analyzed retrospectively with regard to incidence and the need for intraoperative revisions. Clinical evaluation included the patient's medical history, the injury pattern of the affected wrist (according to the OTA/AO fracture classification) and concomitant injuries. Intraoperative and postoperative complications and revision surgeries were evaluated as well. RESULTS: Of 4515 operatively treated distal radius fractures, 307 (6.8%) received additional intraoperative three-dimensional imaging during surgery. 263 of 307 patients (85.7%) had a distal radius fracture type C. Intraoperative three-dimensional imaging revealed findings in 125 patients (40.7%) that were not detected on conventional two-dimensional fluoroscopy. In 54 patients (17.6%) these findings led to an immediate revision. Most commonly, revision was done in the case of remaining steps in the articular surface ≥ 1 mm (n = 25, 8.1%) followed by intra-articular screw placement (n = 23, 7.5%). CONCLUSIONS: Intraoperative three-dimensional imaging can provide additional information compared to conventional two-dimensional fluoroscopy in the operative treatment of distal radius fractures with the possibility of immediate intraoperative revision.


Assuntos
Imageamento Tridimensional , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Humanos , Estudos Retrospectivos
15.
BMC Med Imaging ; 16: 24, 2016 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-26987661

RESUMO

BACKGROUND: Three-dimensional (3D) imaging with a mobile C-arm has proven to be a valuable intraoperative tool in trauma surgery. However, little data is available concerning its use in the treatment of elbow fractures. The aim of the current study was to determine the intraoperative findings and consequences of 3D imaging in the treatment of elbow fractures. METHODS: Between 2001 and 2015, prospectively collected data of 36 patients who underwent intraoperative 3D imaging during elbow surgery were recorded. The findings and consequences of the intraoperative 3D scans were analyzed in a retrospective chart review. For clinical evaluation the analysis included the patients' medical history, the injury pattern of the affected elbow and concomitant injuries. Intraoperative and postoperative complications and revision surgeries were evaluated as well. RESULTS: In 6 patients (16.7%) analysis of the intraoperative 3D scan led to an immediate revision due to the detection of intra-articular screw placement (n = 3, 8.3%) and remaining intra-articular step of >2 mm (n = 3, 8.3%). In all of these patients, correct implant positioning and anatomical reduction could be achieved after immediate intraoperative revision, which was verified by a repeated intraoperative 3D scan. None of the 36 patients needed surgical revision based on postoperative radiological examinations due to secondary dislocation, wrong implant placement or remaining steps in the articular surface. CONCLUSIONS: Intraoperative 3D imaging offers additional information about fracture reduction and implant positioning in the treatment of elbow fractures compared to conventional intraoperative 2D imaging. It may therefore reduce the need for revision surgery. The value of intraoperative 3D imaging for clinical outcomes still needs to be assessed.


Assuntos
Lesões no Cotovelo , Fraturas Ósseas/cirurgia , Imageamento Tridimensional/métodos , Adulto , Cotovelo/cirurgia , Feminino , Fraturas Ósseas/diagnóstico , Humanos , Período Intraoperatório , Masculino , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
16.
Sports (Basel) ; 12(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39195589

RESUMO

INTRODUCTION: There is a lack of information on return to sport and patient-reported outcome measures (PROMs) in amateur athletes after isolated spine injuries. METHODS: A single-center cohort study in amateur athletes aged 18 to 60 with isolated spine injuries; clinical data collection and follow-up via telephone interview and standardized PROMs (Short-Form 36, Oswestry and Neck Disability Index, Tampa Scale of Kinesiophobia, Hospital Anxiety and Depression Scale, Pain Visual Analog Scale). Bivariate analyses of potential influencing factors on PROMs were conducted using the Wilcoxon Signed-Rank Test. p-values < 0.05 were considered statistically significant. RESULTS: Out of the 80 included participants, 78% (n = 62) were active in sport at follow-up. PROMs were slightly worse than those described for the age-adjusted general population. There were consistent associations of better PROMs with having reached the subjective preinjury level of performance in sport, while injury severity and surgical or conservative therapy did not show consistent associations with PROMs. CONCLUSION: Most amateur athletes resume their sports activity after a spine injury. Better outcomes are associated with individuals' resumption of sport and subjective level of performance, while injury severity and surgical or conservative therapy do not show consistent associations with PROMs, highlighting the importance of patient education, rehabilitation, and encouragement.

17.
Spine J ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39154945

RESUMO

BACKGROUND: Intraoperative 3D imaging with cone-beam CT (CBCT) improves assessment of implant position and reduces complications in spine surgery. It is also used for image-guided surgical techniques, resulting in improved quality of care. However, in some cases, metal artifacts can reduce image quality and make it difficult to assess pedicle screw position and reduction. PURPOSE: The objective of this study was to investigate whether a change in CBCT acquisition trajectory in relation to pedicle screw position during dorsal instrumentation can reduce metal artifacts and consequently improve image quality and clinical assessability. STUDY DESIGN: Experimental cadaver study. METHODS: A human cadaver was instrumented with pedicle screws in the thoracic and lumbar spine region (Th11 to L5). Then, the acquisition trajectory of the CBCT (Cios Spin, Siemens, Germany) to the pedicle screws was systematically changed in 5° steps in angulation (-30° to +30°) and swivel (-25° to +25°). Subsequently, radiological evaluation was performed by 3 blinded, qualified raters on image quality using 9 questions (including anatomical structures, implant position, appearance of artifacts) with a score (1-5 points). For statistical evaluation, the image quality of the different acquisition trajectories was compared to the standard acquisition trajectory and checked for significant differences. RESULTS: The angulated acquisition trajectory significantly increased the score for subjective image quality (p<.001) as well as the clinical assessability of pedicle screw position (p<.001) with particularly strong effects on subjective image quality in the vertebral pedicle region (d=1.61). Swivel of the acquisition trajectory significantly improved all queried domains of subjective image quality (p<.001) as well as clinical assessability of pedicle screw position (p<.001). CONCLUSIONS: In this cadaver study, the angulation as well as the swivel of the acquisition trajectory led to a significantly improved image quality in intraoperative 3D imaging (CBCT) with a constant isocenter. The data show that maximizing the angulation/swivel angle towards 30°/25° provides the best tested subjective image quality and enhances clinical assessability. Therefore, a correct adjustment of the acquisition trajectory can help to make intraoperative revision decisions more reliably. CLINICAL SIGNIFICANCE: The knowledge of enhanced image quality by changing the acquisition trajectory in intraoperative 3D imaging can be used for the assessment of critical screw positions in spine surgery. The implementation of this knowledge requires only a minor change of the current intraoperative imaging workflow without additional technical equipment and could further reduce the need for revision surgery.

18.
Eur J Trauma Emerg Surg ; 50(3): 1153-1164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38363327

RESUMO

PURPOSE: To determine the incidence of severe surgical adverse events (sSAE) after surgery of patients with subaxial cervical spine injury (sCS-Fx) and to identify patient, treatment, and injury-related risk factors. METHODS: Retrospective analysis of clinical and radiological data of sCS-Fx patients treated surgically between 2010 and 2020 at a single national trauma center. Baseline characteristics of demographic data, preexisting conditions, treatment, and injury morphology were extracted. Incidences of sSAEs within 60 days after surgery were analyzed. Univariate analysis and binary logistic regression for the occurrence of one or more sSAEs were performed to identify risk factors. P-values < .05 were considered statistically significant. RESULTS: Two hundred and ninety-two patients were included. At least one sSAE occurred in 49 patients (16.8%). Most frequent were sSAEs of the surgical site (wound healing disorder, infection, etc.) affecting 29 patients (9.9%). Independent potential risk factors in logistic regression were higher age (OR 1.02 [1.003-1.04], p = .022), the presence of one or more modifiers in the AO Spine Subaxial Injury Classification (OR 2.02 [1.03-3.96], p = .041), and potentially unstable or unstable facet injury (OR 2.49 [1.24-4.99], p = .010). Other suspected risk factors were not statistically significant, among these Injury Severity Score, the need for surgery for concomitant injuries, the primary injury type according to AO Spine, and preexisting medical conditions. CONCLUSION: sSAE rates after treatment of sCS-Fx are high. The identified risk factors are not perioperatively modifiable, but their knowledge should guide intra and postoperative care and surgical technique.


Assuntos
Vértebras Cervicais , Complicações Pós-Operatórias , Traumatismos da Coluna Vertebral , Humanos , Masculino , Feminino , Fatores de Risco , Estudos Retrospectivos , Vértebras Cervicais/lesões , Vértebras Cervicais/cirurgia , Pessoa de Meia-Idade , Incidência , Adulto , Complicações Pós-Operatórias/epidemiologia , Traumatismos da Coluna Vertebral/cirurgia , Traumatismos da Coluna Vertebral/epidemiologia , Idoso
19.
Foot Ankle Int ; 45(5): 446-455, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501715

RESUMO

BACKGROUND: For the temporary treatment of ankle fracture dislocations (AFDs), previous studies indicate higher rates of secondary loss of reduction (LOR) with splint immobilization, prompting consideration for expanding indications for external fixation (ExFix). However, these studies did not investigate the influence of fracture morphology to further improve patient selection. The aim of this study was to investigate the influence of Lauge-Hansen injury type on the LOR rate in bimalleolar or trimalleolar AFDs for temporary cast vs ExFix immobilization. METHODS: In this retrospective cohort study, patients with isolated AFD cases treated at our institution from 2011 to 2020 were reviewed. Inclusion criteria required radiographs depicting initial dislocation and appropriate reduction after Cast or ExFix immobilization. Exclusion criteria encompassed concomitant injuries, open fractures, conservative management as well as surgery performed within 48 hours or at a different facility. Patients were grouped by temporary treatment (Cast or ExFix). The primary endpoint was LOR prior to definitive surgery across various Lauge-Hansen types. RESULTS: The LOR rate was significantly higher in the cast group (40/152, 26.3%) compared to the ExFix group (5/191, 2.6%; P < .0001). In the cast group, LOR was associated with an increase in time to definitive surgery by a mean of 3 days (P < .002). During cast treatment, LOR was significantly more likely for pronation abduction (P = .001) and supination external rotation injuries (P < .0001), whereas no significant differences were observed for pronation external rotation (P = .006), supination adduction (P > .99), and fractures not classifiable (P > .99). CONCLUSION: In cases of AFDs resulting from supination external rotation or pronation abduction trauma according to the Lauge-Hansen classification, especially in the setting of an additional posterior malleolar fracture, primary application of external fixation should be considered to reduce the risk for secondary loss of reduction. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Fraturas do Tornozelo , Moldes Cirúrgicos , Fratura-Luxação , Humanos , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Fratura-Luxação/cirurgia , Fixação de Fratura/métodos , Idoso , Estudos de Coortes
20.
J Clin Med ; 13(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38592668

RESUMO

(1) Background: In elderly patients with type II odontoid fractures, accompanying severe atlantoaxial instability (AAI) is discussed as a marker possibly warranting more aggressive surgical therapy. This study aimed to characterize adverse events as well as the radiological and functional outcomes of surgical vs. conservative therapy in patients with odontoid fracture and AAI. (2) Methods: Patients aged 65 years and older with type II odontoid fracture and AAI treated were included. AAI was assumed if the mean subluxation across both atlantoaxial facet joints in the sagittal plane was greater than 50%. Data on demographics, comorbidities, treatment, adverse events, radiological, and functional outcomes were analyzed. (3) Results: Thirty-nine patients were included. Hospitalization time was significantly shorter in conservatively treated patients compared to patients with ventral or dorsal surgery. Adverse events occurred in 11 patients (28.2%), affecting 10 surgically treated patients (35.7%), and 1 conservatively treated patient (9.1%). Moreover, 25 patients were followed-up (64.1%). One secondary dislocation occurred in the conservative group (11.1%) and three in the surgical group (18.8%). (4) Conclusions: Despite the potential for instability in this injury, conservative treatment does not seem to lead to unfavorable short-term results, less adverse events, and a shorter hospital stay and should thus be considered and discussed with patients as a treatment option, even in the presence of severe AAI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA