Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(8S1): S188-S199, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38548237

RESUMO

BACKGROUND: Dissatisfaction after total knee arthroplasty (TKA) ranges from 15 to 30%. While patient selection may be partially responsible, morphological and reconstructive challenges may be determinants. Preoperative computed tomography (CT) scans for TKA planning allow us to evaluate the hip-knee-ankle axis and establish a baseline phenotypic distribution across anatomic parameters. The purpose of this cross-sectional analysis was to establish the distributions of 27 parameters in a pre-TKA cohort and perform threshold analysis to identify anatomic outliers. METHODS: There were 1,352 pre-TKA CTs that were processed. A 2-step deep learning pipeline of classification and segmentation models identified landmark images and then generated contour representations. We used an open-source computer vision library to compute measurements for 27 anatomic metrics along the hip-knee axis. Normative distribution plots were established, and thresholds for the 15th percentile at both extremes were calculated. Metrics falling outside the central 70th percentile were considered outlier indices. A threshold analysis of outlier indices against the proportion of the cohort was performed. RESULTS: Significant variation exists in pre-TKA anatomy across 27 normally distributed metrics. Threshold analysis revealed a sigmoid function with a critical point at 9 outlier indices, representing 31.2% of subjects as anatomic outliers. Metrics with the greatest variation related to deformity (tibiofemoral angle, medial proximal tibial angle, lateral distal femoral angle), bony size (tibial width, anteroposterior femoral size, femoral head size, medial femoral condyle size), intraoperative landmarks (posterior tibial slope, transepicondylar and posterior condylar axes), and neglected rotational considerations (acetabular and femoral version, femoral torsion). CONCLUSIONS: In the largest non-industry database of pre-TKA CTs using a fully automated 3-stage deep learning and computer vision-based pipeline, marked anatomic variation exists. In the pursuit of understanding the dissatisfaction rate after TKA, acknowledging that 31% of patients represent anatomic outliers may help us better achieve anatomically personalized TKA, with or without adjunctive technology.


Assuntos
Artroplastia do Joelho , Aprendizado Profundo , Articulação do Joelho , Tomografia Computadorizada por Raios X , Humanos , Artroplastia do Joelho/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Estudos Transversais , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Articulação do Joelho/anatomia & histologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Articulação do Quadril/anatomia & histologia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/anatomia & histologia , Idoso de 80 Anos ou mais
2.
Arthroplast Today ; 27: 101394, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39071819

RESUMO

Background: Variability in the bony morphology of pathologic hips/knees is a challenge in automating preoperative computed tomography (CT) scan measurements. With the increasing prevalence of CT for advanced preoperative planning, processing this data represents a critical bottleneck in presurgical planning, research, and development. The purpose of this study was to demonstrate a reproducible and scalable methodology for analyzing CT-based anatomy to process hip and knee anatomy for perioperative planning and execution. Methods: One hundred patients with preoperative CT scans undergoing total knee arthroplasty for osteoarthritis were processed. A two-step deep learning pipeline of classification and segmentation models was developed that identifies landmark images and then generates contour representations. We utilized an open-source computer vision library to compute measurements. Classification models were assessed by accuracy, precision, and recall. Segmentation models were evaluated using dice and mean Intersection over Union (IOU) metrics. Contour measurements were compared against manual measurements to validate posterior condylar axis angle, sulcus angle, trochlear groove-tibial tuberosity distance, acetabular anteversion, and femoral version. Results: Classifiers identified landmark images with accuracy of 0.91 and 0.88 for hip and knee models, respectively. Segmentation models demonstrated mean IOU scores above 0.95 with the highest dice coefficient of 0.957 [0.954-0.961] (UNet3+) and the highest mean IOU of 0.965 [0.961-0.969] (Attention U-Net). There were no statistically significant differences for the measurements taken automatically vs manually (P > 0.05). Average time for the pipeline to preprocess (48.65 +/- 4.41 sec), classify/retrieve landmark images (8.36 +/- 3.40 sec), segment images (<1 sec), and obtain measurements was 2.58 (+/- 1.92) minutes. Conclusions: A fully automated three-stage deep learning and computer vision-based pipeline of classification and segmentation models accurately localized, segmented, and measured landmark hip and knee images for patients undergoing total knee arthroplasty. Incorporation of clinical parameters, like patient-reported outcome measures and instability risk, will be important considerations alongside anatomic parameters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA