Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Gynecol Obstet Fertil ; 35(6): 541-7, 2007 Jun.
Artigo em Francês | MEDLINE | ID: mdl-17540606

RESUMO

OBJECTIVE: To assess the performance of a power doppler vascularity index in the preoperative diagnosis of ovarian malignancy. PATIENTS AND METHODS: Two successive series of adnexal masses (N=101 and N=82) were examined prospectively with power Doppler before surgical treatment. A vascularity index, called Power Doppler Index (PDI), based on the number of colored pixels, was estimated on selected frames (defined region of interest covering the entire tumor) of the tumors using an in house color-quantifying program. The first study was monocentric to test the inter- and intraobserver reproducibilities and the availability of the parameter. The second was multicentric to validate the first results. The sensitivity and specificity of PDI, resistance index (RI) and subjective visual scoring were compared using receiver operating characteristic (ROC) curves. RESULTS: Histology identified 23 malignant and 78 benign lesions in the first study and 34 malignant and 48 benign tumors in the second. PDI was considerably higher in malignant than in benign lesions (0.34+/-0.04 vs 0.12+/-0.06 (P<0.001)). Intra-observer and interobserver variability of PDI was low (intraclass correlation coefficients estimated at 0.99 and 0.98, respectively). The PDI cut-off value for differential diagnosis was set at 0.265 (26.5% of the tumor is colored) in the first study and 0.107 in the second. Sensitivity and specificity were 100% (95% CI [87.8; 100.0]) and 97.4% (95% CI [91.0; 99.7]), respectively, for PDI in the first study compared to 75% (95% CI [72.9; 90.7]) and 60% (95% CI [56.3; 92.5]) in the second study. Using logistic regression, visual Doppler scoring performed best. DISCUSSION AND CONCLUSION: The Power Doppler Index obtained using our color quantifying software has discriminating power for adnexal masses but visual Doppler scoring performs best.


Assuntos
Neoplasias Ovarianas/diagnóstico por imagem , Ovário/irrigação sanguínea , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/normas , Anexos Uterinos/irrigação sanguínea , Anexos Uterinos/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/epidemiologia , Ovário/diagnóstico por imagem , Curva ROC , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade
2.
J Gynecol Obstet Biol Reprod (Paris) ; 39(4): 325-30, 2010 Jun.
Artigo em Francês | MEDLINE | ID: mdl-20395073

RESUMO

Pseudo-aneurysms of uterine arteries are rare causes of post-partum hemorrhage. We report two cases of rupture, revealed in one case by a hemoperitoneum and in a second case by a retroperitoneal hematoma. The treatment consisted of embolization of uterine arteries with immediate clinical success, to avoid surgery.


Assuntos
Falso Aneurisma/terapia , Aneurisma Roto/terapia , Embolização Terapêutica , Hemorragia Pós-Parto/terapia , Artéria Uterina/lesões , Adulto , Feminino , Hematoma/terapia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA