Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Physiol ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408065

RESUMO

Hypoxia at high altitude facilitates changes in ventilatory control that can lead to nocturnal periodic breathing (nPB). Here, we introduce a placebo-controlled approach to prevent nPB by increasing inspiratory CO2 and used it to assess whether nPB contributes to the adverse effects of hypoxia on sleep architecture. In a randomized, single-blinded, crossover design, 12 men underwent two sojourns (three days/nights each, separated by 4 weeks) in hypobaric hypoxia corresponding to 4000 m altitude, with polysomnography during the first and third night of each sojourn. During all nights, subjects' heads were encompassed by a canopy retaining exhaled CO2 , and CO2 concentration in the canopy (i.e. inspiratory CO2 concentration) was controlled by adjustment of fresh air inflow. Throughout the placebo sojourn inspiratory CO2 was ≤0.2%, whereas throughout the other sojourn it was increased to 1.76% (IQR, 1.07%-2.44%). During the placebo sojourn, total sleep time (TST) with nPB was 54.3% (37.4%-80.8%) and 45.0% (24.5%-56.5%) during the first and the third night, respectively (P = 0.042). Increased inspiratory CO2 reduced TST with nPB by an absolute 38.1% (28.1%-48.1%), the apnoea-hypopnoea index by 58.1/h (40.1-76.1/h), and oxygen desaturation index ≥3% by 56.0/h (38.9.1-73.2/h) (all P < 0.001), whereas it increased the mean arterial oxygen saturation in TST by 2.0% (0.4%-3.5%, P = 0.035). Increased inspiratory CO2 slightly increased the percentage of N3 sleep during the third night (P = 0.045), without other effects on sleep architecture. Increasing inspiratory CO2 effectively prevented hypoxia-induced nPB without affecting sleep macro-architecture, indicating that nPB does not explain the sleep deterioration commonly observed at high altitudes. KEY POINTS: Periodic breathing is common during sleep at high altitude, and it is unclear how this affects sleep architecture. We developed a placebo-controlled approach to prevent nocturnal periodic breathing (nPB) with inspiratory CO2 administration and used it to assess the effects of nPB on sleep in hypobaric hypoxia. Nocturnal periodic breathing was effectively mitigated by an increased inspiratory CO2 fraction in a blinded manner. Prevention of nPB did not lead to relevant changes in sleep architecture in hypobaric hypoxia. We conclude that nPB does not explain the deterioration in sleep architecture commonly observed at high altitude.

2.
Eur J Appl Physiol ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656378

RESUMO

PURPOSE: We hypothesised that during a rest-to-exercise transient in hypoxia (H), compared to normoxia (N), (i) the initial baroreflex sensitivity (BRS) decrease would be slower and (ii) the fast heart rate (HR) and cardiac output (CO) response would have smaller amplitude (A1) due to lower vagal activity in H than N. METHODS: Ten participants performed three rest-to-50 W exercise transients on a cycle-ergometer in N (ambient air) and three in H (inspired fraction of O2 = 0.11). R-to-R interval (RRi, by electrocardiography) and blood pressure profile (by photo-plethysmography) were recorded non-invasively. Analysis of the latter provided mean arterial pressure (MAP) and stroke volume (SV). CO = HR·SV. BRS was calculated by modified sequence method. RESULTS: Upon exercise onset in N, MAP fell to a minimum (MAPmin) then recovered. BRS decreased immediately from 14.7 ± 3.6 at rest to 7.0 ± 3.0 ms mmHg-1 at 50 W (p < 0.01). The first BRS sequence detected at 50 W was 8.9 ± 4.8 ms mmHg-1 (p < 0.05 vs. rest). In H, MAP showed several oscillations until reaching a new steady state. BRS decreased rapidly from 10.6 ± 2.8 at rest to 2.9 ± 1.5 ms mmHg-1 at 50 W (p < 0.01), as the first BRS sequence at 50 W was 5.8 ± 2.6 ms mmHg-1 (p < 0.01 vs. rest). CO-A1 was 2.96 ± 1.51 and 2.31 ± 0.94 l min-1 in N and H, respectively (p = 0.06). HR-A1 was 7.7 ± 4.6 and 7.1 ± 5.9 min-1 in N and H, respectively (p = 0.81). CONCLUSION: The immediate BRS decrease in H, coupled with similar rapid HR and CO responses, is compatible with a withdrawal of residual vagal activity in H associated with increased sympathetic drive.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA