Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Gastrointest Endosc ; 97(2): 184-199.e16, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36084720

RESUMO

BACKGROUND AND AIMS: Publicly available databases containing colonoscopic imaging data are valuable resources for artificial intelligence (AI) research. Currently, little is known regarding the available number and content of these databases. This review aimed to describe the availability, accessibility, and usability of publicly available colonoscopic imaging databases, focusing on polyp detection, polyp characterization, and quality of colonoscopy. METHODS: A systematic literature search was performed in MEDLINE and Embase to identify AI studies describing publicly available colonoscopic imaging databases published after 2010. Second, a targeted search using Google's Dataset Search, Google Search, GitHub, and Figshare was done to identify databases directly. Databases were included if they contained data about polyp detection, polyp characterization, or quality of colonoscopy. To assess accessibility of databases, the following categories were defined: open access, open access with barriers, and regulated access. To assess the potential usability of the included databases, essential details of each database were extracted using a checklist derived from the Checklist for Artificial Intelligence in Medical Imaging. RESULTS: We identified 22 databases with open access, 3 databases with open access with barriers, and 15 databases with regulated access. The 22 open access databases contained 19,463 images and 952 videos. Nineteen of these databases focused on polyp detection, localization, and/or segmentation; 6 on polyp characterization, and 3 on quality of colonoscopy. Only half of these databases have been used by other researcher to develop, train, or benchmark their AI system. Although technical details were in general well reported, important details such as polyp and patient demographics and the annotation process were under-reported in almost all databases. CONCLUSIONS: This review provides greater insight on public availability of colonoscopic imaging databases for AI research. Incomplete reporting of important details limits the ability of researchers to assess the usability of current databases.


Assuntos
Inteligência Artificial , Pólipos do Colo , Humanos , Pólipos do Colo/diagnóstico por imagem , Colonoscópios , Colonoscopia/métodos , Radiografia
2.
Endoscopy ; 55(8): 756-765, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36623839

RESUMO

BACKGROUND : We aimed to compare the accuracy of the optical diagnosis of diminutive colorectal polyps, including sessile serrated lesions (SSLs), between a computer-aided diagnosis (CADx) system and endoscopists during real-time colonoscopy. METHODS : We developed the POLyp Artificial Recognition (POLAR) system, which was capable of performing real-time characterization of diminutive colorectal polyps. For pretraining, the Microsoft-COCO dataset with over 300 000 nonpolyp object images was used. For training, eight hospitals prospectively collected 2637 annotated images from 1339 polyps (i. e. publicly available online POLAR database). For clinical validation, POLAR was tested during colonoscopy in patients with a positive fecal immunochemical test (FIT), and compared with the performance of 20 endoscopists from eight hospitals. Endoscopists were blinded to the POLAR output. Primary outcome was the comparison of accuracy of the optical diagnosis of diminutive colorectal polyps between POLAR and endoscopists (neoplastic [adenomas and SSLs] versus non-neoplastic [hyperplastic polyps]). Histopathology served as the reference standard. RESULTS : During clinical validation, 423 diminutive polyps detected in 194 FIT-positive individuals were included for analysis (300 adenomas, 41 SSLs, 82 hyperplastic polyps). POLAR distinguished neoplastic from non-neoplastic lesions with 79 % accuracy, 89 % sensitivity, and 38 % specificity. The endoscopists achieved 83 % accuracy, 92 % sensitivity, and 44 % specificity. The optical diagnosis accuracy between POLAR and endoscopists was not significantly different (P = 0.10). The proportion of polyps in which POLAR was able to provide an optical diagnosis was 98 % (i. e. success rate). CONCLUSIONS : We developed a CADx system that differentiated neoplastic from non-neoplastic diminutive polyps during endoscopy, with an accuracy comparable to that of screening endoscopists and near-perfect success rate.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Valor Preditivo dos Testes , Imagem de Banda Estreita/métodos , Colonoscopia/métodos , Adenoma/diagnóstico por imagem , Computadores
3.
Gut ; 71(3): 553-560, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34086597

RESUMO

OBJECTIVE: Despite regular colonoscopy surveillance, colorectal cancers still occur in patients with Lynch syndrome. Thus, detection of all relevant precancerous lesions remains very important. The present study investigates Linked Colour imaging (LCI), an image-enhancing technique, as compared with high-definition white light endoscopy (HD-WLE) for the detection of polyps in this patient group. DESIGN: This prospective, randomised controlled trial was performed by 22 experienced endoscopists from eight centres in six countries. Consecutive Lynch syndrome patients ≥18 years undergoing surveillance colonoscopy were randomised (1:1) and stratified by centre for inspection with either LCI or HD-WLE. Primary outcome was the polyp detection rate (PDR). RESULTS: Between January 2018 and March 2020, 357 patients were randomised and 332 patients analysed (160 LCI, 172 HD-WLE; 6 excluded due to incomplete colonoscopies and 19 due to insufficient bowel cleanliness). No significant difference was observed in PDR with LCI (44.4%; 95% CI 36.5% to 52.4%) compared with HD-WLE (36.0%; 95% CI 28.9% to 43.7%) (p=0.12). Of the secondary outcome parameters, more adenomas were found on a patient (adenoma detection rate 36.3%; vs 25.6%; p=0.04) and a colonoscopy basis (mean adenomas per colonoscopy 0.65 vs 0.42; p=0.04). The median withdrawal time was not statistically different between LCI and HD-WLE (12 vs 11 min; p=0.16). CONCLUSION: LCI did not improve the PDR compared with HD-WLE in patients with Lynch syndrome undergoing surveillance. The relevance of findings more adenomas by LCI has to be examined further. TRIAL REGISTRATION NUMBER: NCT03344289.


Assuntos
Adenoma/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais Hereditárias sem Polipose/diagnóstico por imagem , Aumento da Imagem , Adenoma/patologia , Adulto , Idoso , Cor , Neoplasias Colorretais Hereditárias sem Polipose/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Endoscopy ; 54(1): 88-99, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34872120

RESUMO

BACKGROUND : The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 - 5 mm). METHODS : A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds. RECOMMENDATION 1: In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1-5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1-5 mm in the rectosigmoid. Histopathology is used as the gold standard.Level of agreement 95 %. RECOMMENDATION 2: In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1-5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1-5 mm. Histopathology is used as the gold standard.Level of agreement 100 %. CONCLUSION : The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Endoscopia Gastrointestinal , Humanos
5.
Am J Gastroenterol ; 116(4): 825-828, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33982955

RESUMO

INTRODUCTION: The additional diagnostic value of dye-based chromoendosocpy (CE) for surveillance of patients with Lynch syndrome is subject of debate. METHODS: To clarify this debate, we performed an individual patient data meta-analysis of randomized studies that compared CE with WLE for the detection of adenomas in patients with Lynch syndrome. RESULTS: Three randomized studies comprising 533 patients were included. The adenoma detection rate was 74/265 (28%) in patients randomized to WLE compared with 83/266 (31%) in patients randomized to CE (odds ratio 1.17; 95% confidence interval 0.81-1.70). DISCUSSION: Based on low-quality evidence, CE showed no apparent increase in adenoma detection compared to WLE during surveillance of patients with Lynch syndrome.


Assuntos
Colonoscopia/métodos , Neoplasias Colorretais Hereditárias sem Polipose/diagnóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos
6.
Gastrointest Endosc ; 94(4): 812-822.e43, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33887268

RESUMO

BACKGROUND AND AIMS: One reason the optical diagnosis strategy for diminutive colorectal polyps has not yet been implemented is that the current competence criteria (Preservation and Incorporation of Valuable Endoscopic Innovation [PIVI] initiative) are difficult to use in daily practice. To provide guidance for setting alternative easy-to-adopt competence criteria, we determined the lowest proportion of diminutive polyps that should have a correct optical diagnosis to meet the PIVI. METHODS: For this simulation study, we used datasets from 2 prospectively collected cohorts of patients who underwent colonoscopy in either a primary colonoscopy or fecal immunochemical test (FIT) screening setting. In the simulation approach, virtual endoscopists or computer-aided diagnosis systems performed optical diagnosis of diminutive polyps with a fixed diagnostic performance level (strategy) on all individuals in the cohort who had ≥1 diminutive polyp. Strategies were defined by systematically varying the proportion of correct optical diagnoses for each polyp subtype (ie, adenomas, hyperplastic polyps, sessile serrated lesions). For each strategy, we determined whether PIVI-1 (≥90% agreement with U.S. or European Society for Gastrointestinal Endoscopy [ESGE] surveillance guidelines) and PIVI-2 (≥90% negative predictive value [NPV] for neoplastic lesions in the rectosigmoid) were met using Monte Carlo sampling with 1000 repetitions, with histology as reference. RESULTS: The level of overall diagnostic accuracy to achieve the PIVI differed significantly depending on the clinical setting and guidelines used. In the colonoscopy screening setting, all diagnostic strategies in which 92% of all diminutive polyps (regardless of histology) were diagnosed correctly led to 90% or more agreement with U.S. surveillance intervals (ie, PIVI-1). For all diagnostic strategies in which ≥89% of all diminutive polyps were correctly diagnosed, at least 90% NPV was achieved (ie, PIVI-2). For the FIT screening setting, values were respectively ≥77% and ≥94%. When using ESGE guidelines, PIVI-1 was in both settings already met when 40% of all diminutive polyps were diagnosed correctly. CONCLUSIONS: In contrast to the fixed PIVI criteria, our simulation study shows that different thresholds for the proportion of correctly diagnosed diminutive polyps lead to different clinical consequences depending on guidelines and clinical setting. However, this target proportion of diminutive colorectal polyps correctly diagnosed with optical diagnosis represents easier-to-adopt competence criteria.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adenoma/diagnóstico por imagem , Adenoma/patologia , Colo/patologia , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Humanos , Imagem de Banda Estreita , Valor Preditivo dos Testes , Reto
7.
Lancet ; 394(10207): 1467-1480, 2019 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-31631858

RESUMO

Several decades ago, colorectal cancer was infrequently diagnosed. Nowadays, it is the world's fourth most deadly cancer with almost 900 000 deaths annually. Besides an ageing population and dietary habits of high-income countries, unfavourable risk factors such as obesity, lack of physical exercise, and smoking increase the risk of colorectal cancer. Advancements in pathophysiological understanding have increased the array of treatment options for local and advanced disease leading to individual treatment plans. Treatments include endoscopic and surgical local excision, downstaging preoperative radiotherapy and systemic therapy, extensive surgery for locoregional and metastatic disease, local ablative therapies for metastases, and palliative chemotherapy, targeted therapy, and immunotherapy. Although these new treatment options have doubled overall survival for advanced disease to 3 years, survival is still best for those with non-metastasised disease. As the disease only becomes symptomatic at an advanced stage, worldwide organised screening programmes are being implemented, which aim to increase early detection and reduce morbidity and mortality from colorectal cancer.


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/terapia , Neoplasias Colorretais/epidemiologia , Humanos
8.
Gastroenterology ; 156(3): 623-634.e3, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30395813

RESUMO

BACKGROUND & AIMS: With advances in endoscopic imaging, it is possible to differentiate adenomatous from hyperplastic diminutive (1-5 mm) polyps during endoscopy. With the optical Resect-and-Discard strategy, these polyps are then removed and discarded without histopathology assessment. However, failure to recognize adenomas (vs hyperplastic polyps), or discarding a polyp with advanced histologic features, could result in a patient being considered at low risk for metachronous advanced neoplasia, resulting in an inappropriately long surveillance interval. We collected data from international cohorts of patients undergoing colonoscopy to determine what proportion of patients are high risk because of diminutive polyps advanced histologic features and their risk for metachronous advanced neoplasia. METHODS: We collected data from 12 cohorts (in the United States or Europe) of patients undergoing colonoscopy after a positive result from a fecal immunochemical test (FIT cohort, n = 34,221) or undergoing colonoscopies for screening, surveillance, or evaluation of symptoms (colonoscopy cohort, n = 30,123). Patients at high risk for metachronous advanced neoplasia were defined as patients with polyps that had advanced histologic features (cancer, high-grade dysplasia, ≥25% villous features), 3 or more diminutive or small (6-9 mm) nonadvanced adenomas, or an adenoma or sessile serrated lesion ≥10 mm. Using an inverse variance random effects model, we calculated the proportion of diminutive polyps with advanced histologic features; the proportion of patients classified as high risk because their diminutive polyps had advanced histologic features; and the risk of these patients for metachronous advanced neoplasia. RESULTS: In 51,510 diminutive polyps, advanced histologic features were observed in 7.1% of polyps from the FIT cohort and 1.5% polyps from the colonoscopy cohort (P = .044); however, this difference in prevalence did not produce a significant difference in the proportions of patients assigned to high-risk status (0.8% of patients in the FIT cohort and 0.4% of patients in the colonoscopy cohort) (P = .25). The proportions of high-risk patients because of diminutive polyps with advanced histologic features who were found to have metachronous advanced neoplasia (17.6%) did not differ significantly from the proportion of low-risk patients with metachronous advanced neoplasia (14.6%) (relative risk for high-risk categorization, 1.13; 95% confidence interval 0.79-1.61). CONCLUSION: In a pooled analysis of data from 12 international cohorts of patients undergoing colonoscopy for screening, surveillance, or evaluation of symptoms, we found that diminutive polyps with advanced histologic features do not increase risk for metachronous advanced neoplasia.


Assuntos
Neoplasias do Colo/patologia , Pólipos do Colo/patologia , Segunda Neoplasia Primária/patologia , Lesões Pré-Cancerosas/patologia , Fatores Etários , Idoso , Biópsia por Agulha , Estudos de Coortes , Neoplasias do Colo/diagnóstico , Neoplasias do Colo/epidemiologia , Pólipos do Colo/diagnóstico , Pólipos do Colo/epidemiologia , Colonoscopia/métodos , Intervalos de Confiança , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Imuno-Histoquímica , Incidência , Internacionalidade , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Segunda Neoplasia Primária/diagnóstico , Segunda Neoplasia Primária/epidemiologia , Lesões Pré-Cancerosas/epidemiologia , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Fatores Sexuais
9.
Endoscopy ; 52(9): 763-772, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32349138

RESUMO

INTRODUCTION : Endoscopists with a high adenoma detection rate (ADR) and proximal serrated polyp detection rate (PSPDR) detect these polyps more frequently, which may be attributable to better recognition of their endoscopic features. Little is known about the association between endoscopic lesion detection and differentiation skills. Therefore, we evaluated the correlation between the ADR, PSPDR, and the sensitivity of optical diagnosis for adenomas and serrated polyps. METHODS: We performed an exploratory post-hoc analysis of the DISCOUNT-2 study, including complete colonoscopies after a positive fecal immunochemical test (FIT) performed by endoscopists who performed ≥ 50 colonoscopies. The correlations between the ADR, PSPDR, and the sensitivity of optical diagnosis were calculated using Pearson's rho correlation coefficient. RESULTS: 24 endoscopists performed ≥ 50 colonoscopies, resulting in a total of 2889 colonoscopies. The overall ADR was 84.5 % (range 71.4 % - 95.3 %) and overall PSPDR was 13.7 % (4.3 % - 29.0 %). The sensitivity of optical diagnosis for adenomas and serrated polyps were 94.5 % (83.3 % - 100 %) and 74.0 % (37.5 % - 94.1 %), respectively. No correlation could be demonstrated between the ADR and the sensitivity of optical diagnosis for adenomas (-0.20; P = 0.35) or between the PSPDR and the sensitivity of optical diagnosis for serrated polyps (-0.12; P = 0.57). CONCLUSIONS: In a homogeneous FIT-positive population, no correlation between the ADR, PSPDR, and the sensitivity of optical diagnosis for adenomas and serrated polyps could be demonstrated. These exploratory results suggest that lesion detection and differentiation require different endoscopic skills. Further prospective studies are needed; until then, monitoring of both performance indicators is important to secure optimal efficacy of FIT-based colorectal cancer screening.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adenoma/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Detecção Precoce de Câncer , Humanos , Estudos Prospectivos
10.
Gastroenterology ; 154(6): 1682-1693.e1, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29425923

RESUMO

BACKGROUND & AIMS: Real-time differentiation of diminutive polyps (1-5 mm) during endoscopy could replace histopathology analysis. According to guidelines, implementation of optical diagnosis into routine practice would require it to identify rectosigmoid neoplastic lesions with a negative predictive value (NPV) of more than 90%, using histologic findings as a reference, and agreement with histology-based surveillance intervals for more than 90% of cases. METHODS: We performed a prospective study with 39 endoscopists accredited to perform colonoscopies on participants with positive results from fecal immunochemical tests in the Bowel Cancer Screening Program at 13 centers in the Netherlands. Endoscopists were trained in optical diagnosis using a validated module (Workgroup serrAted polypS and Polyposis). After meeting predefined performance thresholds in the training program, the endoscopists started a 1-year program (continuation phase) in which they performed narrow band imaging analyses during colonoscopies of participants in the screening program and predicted histological findings with confidence levels. The endoscopists were randomly assigned to groups that received feedback or no feedback on the accuracy of their predictions. Primary outcome measures were endoscopists' abilities to identify rectosigmoid neoplastic lesions (using histology as a reference) with NPVs of 90% or more, and selecting surveillance intervals that agreed with those determined by histology for at least 90% of cases. RESULTS: Of 39 endoscopists initially trained, 27 (69%) completed the training program. During the continuation phase, these 27 endoscopists performed 3144 colonoscopies in which 4504 diminutive polyps were removed. The endoscopists identified neoplastic lesions with a pooled NPV of 90.8% (95% confidence interval 88.6-92.6); their proposed surveillance intervals agreed with those determined by histologic analysis for 95.4% of cases (95% confidence interval 94.0-96.6). Findings did not differ between the group that did vs did not receive feedback. Sixteen endoscopists (59%) identified rectosigmoid neoplastic lesions with NPVs greater than 90% and selected surveillance intervals in agreement with those determined from histology for more than 90% of patients. CONCLUSIONS: In a prospective study following a validated training module, we found that a selected group of endoscopists identified rectosigmoid neoplastic lesions with pooled NPVs greater than 90% and accurately selected surveillance intervals for more than 90% of patients over the course of 1 year. Providing regular interim feedback on the accuracy of neoplastic lesion prediction and surveillance interval selection did not lead to differences in those endpoints. Monitoring is suggested, as individual performance varied. ClinicalTrials.gov no: NCT02516748; Netherland Trial Register: NTR4635.


Assuntos
Colonoscopia/estatística & dados numéricos , Detecção Precoce de Câncer/estatística & dados numéricos , Educação/métodos , Imagem de Banda Estreita/estatística & dados numéricos , Vigilância da População/métodos , Competência Clínica , Pólipos do Colo/complicações , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/educação , Detecção Precoce de Câncer/métodos , Retroalimentação , Humanos , Imagem de Banda Estreita/métodos , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Neoplasias Retais/diagnóstico , Neoplasias Retais/etiologia , Neoplasias do Colo Sigmoide/diagnóstico , Neoplasias do Colo Sigmoide/etiologia
11.
Endoscopy ; 51(3): 244-252, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30544284

RESUMO

BACKGROUND: Optical diagnosis can replace histopathology of diminutive (1 - 5 mm) polyps if surveillance intervals based on optical diagnosis of polyps have ≥ 90 % agreement with intervals based on polyp histology and if the negative predictive value (NPV) for predicting neoplastic histology in the rectosigmoid is ≥ 90 %. This study aims to assess whether small (6 - 9 mm) polyps can be included in optical diagnosis strategies. METHOD: This is a post-hoc analysis of a prospective multicenter study in which 27 endoscopists, all performing endoscopies for the Dutch screening program, were trained in optical diagnosis. For 1 year, endoscopists recorded the predicted histology for all lesions detected using narrow-band imaging during 3144 consecutive colonoscopies after a positive fecal immunochemical test, along with confidence levels. Surveillance interval agreement and NPV were calculated for high confidence predictions for polyps of 1 - 9 mm and compared with histopathology. Surveillance interval agreement was calculated using the European Society of Gastrointestinal Endoscopy surveillance guideline. RESULTS: Surveillance interval agreement was 95.4 % (confidence interval [CI] 94.2 % - 96.4 %), and NPV for predicting neoplastic histology in the rectosigmoid 90.0 % (CI 87.3 % - 92.2 %). The reduction in histology (45.9 % vs. 30.5 %) and the proportion of patients who could have received direct surveillance advice (15.6 % vs. 7.3 %) was higher when small polyps were included (P < 0.001). T1 cancer was found in seven small polyps (0.33 %), five of which would have been discarded without histopathology. CONCLUSION: Including small polyps in the optical diagnosis strategy improves its efficacy while maintaining performance thresholds. However, there is a small risk of missing T1 cancers when small polyps are included in the optical diagnosis strategy.


Assuntos
Pólipos do Colo/diagnóstico , Colonoscopia/educação , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Imagem de Banda Estreita/métodos , Idoso , Pólipos do Colo/patologia , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
12.
Gastrointest Endosc ; 87(5): 1289-1296, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29233671

RESUMO

BACKGROUND AND AIMS: Carcinogenesis in Lynch syndrome involves fast progression of adenomas to colorectal cancer (CRC) because of microsatellite instability. The role of sessile serrated lesions (SSLs) and the serrated neoplasia pathway in these patients is unknown. The aim of this matched case-control study was to compare endoscopic detection rates and distribution of SSLs in Lynch syndrome patients with a matched control population. METHODS: We collected data of Lynch syndrome patients with a proven germline mutation who underwent colonoscopy between January 2011 and April 2016 in 2 tertiary referral hospitals. Control subjects undergoing elective colonoscopy from 2011 and onward for symptoms or surveillance were selected from a prospectively collected database. Patients were matched 1:1 for age, gender, and index versus surveillance colonoscopy. An expert pathology review of serrated polyps was performed. The primary outcomes included the detection rates and distribution of SSLs. RESULTS: We identified 321 patients with Lynch syndrome who underwent at least 1 colonoscopy. Of these, 223 Lynch syndrome patients (mean age, 49.3; 59% women; index colonoscopy, 56%) were matched to 223 control subjects. SSLs were detected in 7.6% (95% confidence interval, 4.8-11.9) of colonoscopies performed in Lynch syndrome patients and in 6.7% (95% confidence interval, 4.1-10.8) of control subjects (P = .86). None of the detected SSLs in Lynch syndrome patients contained dysplasia. CONCLUSIONS: The detection rate of SSLs in Lynch syndrome patients undergoing colonoscopy is comparable with a matched population. These findings suggest that the role of the serrated neoplasia pathway in CRC development in Lynch syndrome seems to be comparable with that in the general population.


Assuntos
Adenoma/patologia , Pólipos do Colo/patologia , Neoplasias Colorretais Hereditárias sem Polipose/patologia , Neoplasias Colorretais/patologia , Adenoma/diagnóstico , Adulto , Estudos de Casos e Controles , Pólipos do Colo/diagnóstico , Colonoscopia , Neoplasias Colorretais/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Gastrointest Endosc ; 85(6): 1169-1176.e1, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28024986

RESUMO

BACKGROUND AND AIMS: Diminutive (1-5 mm) and small (6-9 mm) polyps comprise 90% of detected lesions during colonoscopy and rarely contain advanced histology or colorectal cancer (CRC). Routine removal of these lesions results in a significant burden to colonoscopy programs. At the same time, the risk for progression of these polyps to CRC is unclear. We performed a systematic review to explore the natural history of diminutive and small colorectal polyps. METHODS: We searched MEDLINE and EMBASE for studies investigating the natural history of colorectal polyps. Studies were considered eligible when they assessed patients with 1- to 9-mm polyps that were not treated with polypectomy and that underwent follow-up. We excluded studies in patients with inflammatory bowel disease, polyposis syndromes, and previously diagnosed CRC. We independently extracted study characteristics and evaluated CRC and advanced adenoma (size ≥ 10 mm, containing high-grade dysplasia or villous features) as outcome parameters. RESULTS: Of 8775 retrieved studies, 9 studies with 721 patients were included that prospectively evaluated the evolution of 1- to 9-mm polyps. In 7 studies the average duration of observation was 2 to 3 years. There was only 1 study in which 1 small polyp might have progressed to cancer. Of 1034 adenomas sized 1 to 9 mm in those studies, 6% progressed to advanced adenomas over time. CONCLUSIONS: Based on this systematic review, it appears that some 1- to 9-mm adenomas progress to advanced adenomas within 2 to 3 years. No information on long-term CRC transition rates was found. Defining the biologic significance of these polyps is needed to balance between benefits and harm of polypectomy. (PROSPERO database registration number: CRD42016036577.).


Assuntos
Adenoma/patologia , Pólipos do Colo/patologia , Neoplasias Colorretais/patologia , Carcinoma/patologia , Colonoscopia , Progressão da Doença , Humanos , Pólipos Intestinais/patologia , Carga Tumoral
15.
J Clin Gastroenterol ; 51(5): 426-432, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27775962

RESUMO

BACKGROUND: Optical diagnosis of diminutive (1 to 5 mm) polyps could result in a more cost-effective colonoscopy practice. Previous optical diagnosis studies did not incorporate the differentiation of sessile serrated polyps (SSPs). This study aimed to evaluate the impact of optical diagnosis of diminutive SSPs on the overall performance of endoscopic polyp differentiation in daily colonoscopy practice. METHODS: Endoscopy data were prospectively collected between 2011 and 2014 in a colonoscopy center. Each endoscopist reported a real-time optical diagnosis (SSP, adenoma or hyperplastic polyp) for all lesions in a structured colonoscopy reporting system, using narrow band imaging at their discretion. Study outcomes were accuracy of optical diagnosis, surveillance interval agreement and negative predictive value for diminutive rectosigmoid neoplastic histology based on the optical diagnosis of diminutive polyps compared to histopathology. RESULTS: Of 2853 removed diminutive polyps, 202 (7.1%) were histologically proven SSPs. Optical diagnosis of diminutive SSPs was accurate in 24.4%. Diminutive SSPs determined 6.9% of postpolypectomy surveillance assignments. Inaccurate optical diagnosis of diminutive SSPs led to lower surveillance interval agreement (78.1% vs. 53.3%, P<0.01) and pooled negative predictive value per polyp (84.3% vs. 50.0%; P<0.01) in patients with diminutive SSPs when compared to patients without diminutive SSPs. Accurate endoscopic identification of diminutive SSPs improved from 0% in 2011 to 47% in 2014 (P=0.02). CONCLUSIONS: Endoscopic characterization of diminutive SSPs is difficult, impairing overall performance of optical diagnosis in patients with diminutive SSPs. Future optical diagnosis studies should use validated trainings and classification algorithms that include differentiation of SSPs.


Assuntos
Pólipos Adenomatosos/patologia , Pólipos do Colo/patologia , Colonoscopia , Neoplasias Colorretais/patologia , Pólipos Adenomatosos/cirurgia , Idoso , Biópsia , Pólipos do Colo/cirurgia , Neoplasias Colorretais/cirurgia , Estudos Transversais , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Carga Tumoral
16.
Dig Endosc ; 28(3): 250-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26257272

RESUMO

Implementation of nationwide screening programs aims to decrease the disease burden of colorectal cancer (CRC) in the general population. Globally, most population screening programs for CRC are carried out by either fecal occult blood test, flexible sigmoidoscopy or colonoscopy. For screening programs with colonoscopy as the primary method, only circumstantial evidence from observational studies is available to prove its effectiveness, suggesting that colonoscopy effectively reduces CRC incidence and mortality. Currently, large randomized trials are being conducted to corroborate these findings. Besides the direct effect of a screening program for CRC, its protective effect is further enhanced by enrolment of patients that underwent polypectomy in surveillance programs. However, despite CRC screening and surveillance colonoscopies, interval CRC still occur. Those are predominantly located in the right-sided colon and potential explanations, besides unfavorable tumor characteristics, are preventable operator-dependent factors relating to the quality of the colonoscopy procedure. In an effort to reduce differences in endoscopists' performance and thereby the occurrence of interval CRC, quality indicators of colonoscopy have been introduced. In addition, emerging advanced colonoscopy techniques might contribute to improvement in polyp detection and removal. Meticulous inspection of the colonic mucosa not only results in the detection of advanced and relevant lesions, but also in the removal of many diminutive and small lesions leading to an increasing number of surveillance colonoscopies, known as the 'high-detection paradox'. More data on the cost-effectiveness of high-quality colonoscopy as a primary screening method and surveillance programs with intervals based on optimal risk stratification are eagerly awaited.


Assuntos
Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/terapia , Humanos , Incidência , Programas de Rastreamento
19.
Ned Tijdschr Geneeskd ; 1662022 11 30.
Artigo em Holandês | MEDLINE | ID: mdl-36632839

RESUMO

Unexpected weight loss presents a diagnostic challenge as it is associated with a wide range of benign and serious conditions. Although it is readily associated with malignancy, the risk of cancer in adults with unexpected weight loss presenting to primary care is 2% or less. In male patients aged 60 years or older and in patients with concurrent clinical symptoms, signs and abnormal blood test, the risk of cancer increases. Initial testing should include a history including medication review, physical examination and blood tests. Recommended blood tests include a complete blood count, basic metabolic panel, liver function tests, thyroid function tests, C-reactive protein level, erythrocyte sedimentation rate and lactate dehydrogenase measurement. Imaging and invasive testing may be considered based on initial evaluation. When the initial evaluation is unremarkable, an observation period is recommended for young patients in particular.


Assuntos
Neoplasias , Adulto , Humanos , Masculino , Neoplasias/diagnóstico , Testes de Função Hepática , Redução de Peso , Testes Diagnósticos de Rotina , Exame Físico
20.
Endosc Int Open ; 10(1): E9-E18, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35047330

RESUMO

Background and study aims Fujifilm has developed a novel ELUXEO 7000 endoscope system that employs light-emitting diodes (LEDs) at four different wavelengths as light sources that enable blue light imaging (BLI), linked color imaging (LCI), and high-definition white-light endoscopy (HD-WLE). The aim of this study was to address the diagnostic accuracy of real-time polyp characterization using BLI, LCI and HD-WLE (ELUXEO 7000 endoscopy system). Patients methods This is a prespecified post-hoc analysis of a prospective study in which 22 experienced endoscopists (> 2,000 colonoscopies) from eight international centers participated. Using a combination of BLI, LCI, and HD-WLE, lesions were endoscopically characterized including a high- or low-confidence statement. Per protocol, digital images were created from all three imaging modalities. Histopathology was the reference standard. Endoscopists were familiar with polyp characterization, but did not take dedicated training for purposes of this study. Results Overall, 341 lesions were detected in 332 patients. Of the lesions, 269 histologically confirmed polyps with an optical diagnosis were included for analysis (165 adenomas, 27 sessile serrated lesions, and 77 hyperplastic polyps). Overall, polyp characterization was performed with high confidence in 82.9 %. The overall accuracy for polyp characterization was 75.1 % (95 % confidence interval [CI] 69.5-80.1 %), compared with an accuracy of 78.0 % (95 % CI 72.0-83.2 %) for high confidence assignments. The accuracy for endoscopic characterization for diminutive polyps was 74.7 % (95 %CI 68.4-80.3 %), compared with an accuracy of 78.2 % (95 % CI 71.4-84.0 %) for high-confidence assignments. Conclusions The diagnostic accuracy of BLI, LCI, and HD-WLE by experienced endoscopist for real-time polyp characterization seems limited (NCT03344289).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA