Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
J Perianesth Nurs ; 39(2): 235-239, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37999688

RESUMO

PURPOSE: Sevoflurane is an inhalational general anesthetic that has been used recently to treat chronic, painful lesions, reportedly supporting analgesia and wound healing. The potential for repeated exposure to off-gassed sevoflurane vapor, especially outside the air-conditioned operating theatre environment, is of some concern. DESIGN: This paper explores the qualitative and quantitative pathing of off-gassed sevoflurane from a topically applied liquid source. METHODS: Using a small, unventilated test-box (total volume 0.5 m3) with infra-red imaging and gas-analysing, we investigated the spatial distribution of sevoflurane vapor following complete vaporization of a 20 mL liquid sample. Utilizing the infra-red absorption of sevoflurane, it was possible to visualize (as an apparent reduction in temperature) the streaming path of the sevoflurane vapor. Sevoflurane levels (%) in the test-box were measured using an infra-red gas analyzer. FINDINGS: In keeping with its higher density than air, sevoflurane vapor was seen to "waterfall" from the liquid source and accumulate in the bottom of the test-box. Sevoflurane vapor concentration was minimal above the liquid source. When extrapolated to a larger (unventilated) room, we estimate that the sevoflurane concentration would be less than 10 ppm one centimetre above the liquid pool. With vacuum extraction, these levels would be even lower. CONCLUSIONS: Due to sevoflurane's tendency to accumulate on the floor, it is concluded that topical application of liquid sevoflurane posses virtually no risk to off-gas exposure in unventilated spaces.


Assuntos
Anestésicos Inalatórios , Éteres Metílicos , Sevoflurano , Éteres Metílicos/análise , Anestésicos Inalatórios/análise , Salas Cirúrgicas
2.
Int J Mol Sci ; 24(7)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37047423

RESUMO

To investigate the impact of experimental interventions on living biological tissue, ex vivo rodent brain slices are often used as a more controllable alternative to a live animal model. However, for meaningful results, the biological sample must be known to be healthy and viable. One of the gold-standard approaches to identifying tissue viability status is to measure the rate of tissue oxygen consumption under specific controlled conditions. Here, we work with thin (400 µm) slices of mouse cortical brain tissue which are sustained by a steady flow of oxygenated artificial cerebralspinal fluid (aCSF) at room temperature. To quantify tissue oxygen consumption (Q), we measure oxygen partial pressure (pO2) as a function of probe depth. The curvature of the obtained parabolic (or parabola-like) pO2 profiles can be used to extract Q, providing one knows the Krogh coefficient Kt, for the tissue. The oxygen trends are well described by a Fick's law diffusion-consumption model developed by Ivanova and Simeonov, and expressed in terms of ratio (Q/K), being the rate of oxygen consumption in tissue divided by the Krogh coefficient (oxygen diffusivity × oxygen solubility) for tissue. If the fluid immediately adjacent to the tissue can be assumed to be stationary (i.e., nonflowing), one may invoke conservation of oxygen flux K·(∂P/∂x) across the interface to deduce (Kt/Kf), the ratio of Krogh coefficients for tissue and fluid. Using published interpolation formulas for the effect of salt content and temperature on oxygen diffusivity and solubility for pure water, we estimate Kf, the Krogh coefficient for aCSF, and hence deduce the Kt coefficient for tissue. We distinguish experimental uncertainty from natural biological variability by using pairs of repeated profiles at the same tissue location. We report a dimensionless Krogh ratio (Kt/Kf)=0.562±0.088 (mean ± SD), corresponding to a Krogh coefficient Kt=(1.29±0.21)×10-14 mol/(m·s·Pa) for mouse cortical tissue at room temperature, but acknowledge the experimental limitation of being unable to verify that the fluid boundary layer is truly stationary. We compare our results with those reported in the literature, and comment on the challenges and ambiguities caused by the extensive use of 'biologically convenient' non-SI units for tissue Krogh coefficient.


Assuntos
Oxigênio , Roedores , Animais , Camundongos , Difusão , Testes de Função Respiratória , Consumo de Oxigênio
3.
J Clin Monit Comput ; 35(6): 1485-1489, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33180248

RESUMO

Quantification of plasma propofol (2,6-diisopropylphenol) in the context of clinical anaesthesia is challenging because of the need for offline blood sample processing using specialised laboratory equipment and techniques. In this study we sought to refine a simple procedure using solid phase extraction and colorimetric analysis into a benchtop protocol for accurate blood propofol measurement. The colorimetric method based on the reaction of phenols (e.g. propofol) with Gibbs reagent was first tested in 10% methanol samples (n = 50) containing 0.5-6.0 µg/mL propofol. Subsequently, whole blood samples (n = 15) were spiked to known propofol concentrations and processed using reverse phase solid phase extraction (SPE) and colorimetric analysis. The standard deviation of the difference between known and measured propofol concentrations in the methanol samples was 0.11 µg/mL, with limits of agreement of - 0.21 to 0.22 µg/mL. For the blood-processed samples, the standard deviation of the difference between known and measured propofol concentrations was 0.09 µg/mL, with limits of agreement - 0.18 to 0.17 µg/mL. Quantification of plasma propofol with an error of less than 0.2 µg/mL is achievable with a simple and inexpensive benchtop method.


Assuntos
Propofol , Cromatografia Líquida de Alta Pressão , Colorimetria , Humanos , Reprodutibilidade dos Testes , Extração em Fase Sólida
4.
Int J Mol Sci ; 21(13)2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32630300

RESUMO

Regulation of synaptically located ionotropic receptors is thought to be the main mechanism by which anaesthetics cause unconsciousness. An alternative explanation, which has received much less attention, is that of primary anaesthetic disruption of brain metabolism via suppression of mitochondrial proteins. In this pilot study in mouse cortical slices, we investigated the effect of disrupting cellular metabolism on tissue oxygen handling and cortical population seizure-like event (SLE) activity, using the mitochondrial complex I inhibitor rotenone, and compared this to the effects of the general anaesthetics sevoflurane, propofol and ketamine. Rotenone caused an increase in tissue oxygen (98 mmHg to 157 mmHg (p < 0.01)) before any measurable change in SLE activity. Thereafter, tissue oxygen continued to increase and was accompanied by a significant and prolonged reduction in SLE root mean square (RMS) activity (baseline RMS of 1.7 to 0.7 µV, p < 0.001) and SLE frequency (baseline 4.2 to 0.4 events/min, p = 0.001). This temporal sequence of effects was replicated by all three anaesthetic drugs. In conclusion, anaesthetics with differing synaptic receptor mechanisms all effect changes in tissue oxygen handling and cortical network activity, consistent with a common inhibitory effect on mitochondrial function. The temporal sequence suggests that the observed synaptic depression-as seen in anaesthesia-may be secondary to a reduction in cellular metabolic capacity.


Assuntos
Anestésicos Inalatórios/farmacologia , Complexo I de Transporte de Elétrons/efeitos dos fármacos , Complexo I de Transporte de Elétrons/metabolismo , Animais , Encéfalo/efeitos dos fármacos , Complexo I de Transporte de Elétrons/antagonistas & inibidores , Feminino , Ketamina/farmacologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Mitocôndrias/efeitos dos fármacos , Oxigênio/metabolismo , Projetos Piloto , Propofol/farmacologia , Rotenona/metabolismo , Rotenona/farmacologia , Sevoflurano/farmacologia
5.
Molecules ; 25(12)2020 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-32604891

RESUMO

A series of benzene ring substituted ketamine N-alkyl esters were prepared from the corresponding substituted norketamines. Few of the latter have been reported since they have not been generally accessible via known routes. We report a new general route to many of these norketamines via the Neber (oxime to α-aminoketone) rearrangement of readily available substituted 2-phenycyclohexanones. We explored the use of the substituents Cl, Me, OMe, CF3, and OCF3, with a wide range of lipophilic and electronic properties, at all available benzene ring positions. The 2- and 3-substituted compounds were generally more active than 4-substituted compounds. The most generally acceptable substituent was Cl, while the powerful electron-withdrawing substituents CF3 and OCF3 provided fewer effective analogues.


Assuntos
Analgésicos/síntese química , Anestésicos/síntese química , Cicloexanos/síntese química , Ketamina/análogos & derivados , Analgésicos/administração & dosagem , Analgésicos/química , Analgésicos/farmacologia , Anestésicos/administração & dosagem , Anestésicos/química , Anestésicos/farmacologia , Animais , Cicloexanos/administração & dosagem , Cicloexanos/química , Cicloexanos/farmacologia , Regulação para Baixo , Ésteres/química , Concentração Inibidora 50 , Ketamina/química , Estrutura Molecular , Oximas/química , Ratos , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Relação Estrutura-Atividade
6.
BMC Genomics ; 20(1): 281, 2019 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-30971208

RESUMO

BACKGROUND: Ketamine ester analogs, SN 35210 and SN 35563, demonstrate different pharmacological profiles to ketamine in animal models. Both confer hypnosis with predictably rapid offset yet, paradoxically, SN35563 induces a prolonged anti-nociceptive state. To explore underlying mechanisms, broad transcriptome changes were measured and compared across four relevant target regions of the rat brain. RESULTS: SN 35563 produced large-scale alteration of gene expression in the Basolateral Amygdala (BLA) and Paraventricular Nucleus of the Thalamus (PVT), in excess of 10x that induced by ketamine and SN 35210. A smaller and quantitatively similar number of gene changes were observed in the Insula (INS) and Nucleus Accumbens (ACB) for all three agents. In the BLA and PVT, SN 35563 caused enrichment for gene pathways related to the function and structure of glutamatergic synapses in respect to: release of neurotransmitter, configuration of postsynaptic AMPA receptors, and the underlying cytoskeletal scaffolding and alignment. CONCLUSION: The analgesic ketamine ester analog SN 35563 induces profound large-scale changes in gene expression in key pain-related brain regions reflecting its unique prolonged pharmacodynamic profile.


Assuntos
Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Ésteres/química , Ketamina/análogos & derivados , Ketamina/farmacologia , Transcrição Gênica/efeitos dos fármacos , Animais , Feminino , Redes Reguladoras de Genes/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley
7.
Anesthesiology ; 130(6): 1049-1063, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30694851

RESUMO

General anesthetics have been used to ablate consciousness during surgery for more than 150 yr. Despite significant advances in our understanding of their molecular-level pharmacologic effects, comparatively little is known about how anesthetics alter brain dynamics to cause unconsciousness. Consequently, while anesthesia practice is now routine and safe, there are many vagaries that remain unexplained. In this paper, the authors review the evidence that cortical network activity is particularly sensitive to general anesthetics, and suggest that disruption to communication in, and/or among, cortical brain regions is a common mechanism of anesthesia that ultimately produces loss of consciousness. The authors review data from acute brain slices and organotypic cultures showing that anesthetics with differing molecular mechanisms of action share in common the ability to impair neurophysiologic communication. While many questions remain, together, ex vivo and in vivo investigations suggest that a unified understanding of both clinical anesthesia and the neural basis of consciousness is attainable.


Assuntos
Anestésicos Gerais/administração & dosagem , Córtex Cerebral/efeitos dos fármacos , Eletroencefalografia/efeitos dos fármacos , Rede Nervosa/efeitos dos fármacos , Animais , Córtex Cerebral/fisiologia , Eletroencefalografia/métodos , Humanos , Rede Nervosa/fisiologia , Técnicas de Cultura de Órgãos
10.
Bioorg Med Chem ; 27(7): 1226-1231, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30792105

RESUMO

N-Aliphatic ester analogues of the non-opioid ketamine (1) retain effective anaesthetic/analgesic properties while minimising ketamine's psychomimetic side-effects. We show that the anaesthetic/analgesic properties of these ester analogues depend critically on the length (from 2 to 4 carbons), polarity and steric cross-section of the aliphatic linker chain. More stable amide and ethylsulfone analogues generally showed weaker anaesthetic/analgesic activity. There was no correlation between the anaesthetic/analgesic properties of the compounds and their binding affinities for the N-methyl-d-aspartate (NMDA) receptor.


Assuntos
Amidas/farmacologia , Anestésicos/farmacologia , Ésteres/farmacologia , Ketamina/farmacologia , Nociceptividade/efeitos dos fármacos , Limiar da Dor/efeitos dos fármacos , Amidas/administração & dosagem , Anestésicos/administração & dosagem , Animais , Relação Dose-Resposta a Droga , Ésteres/administração & dosagem , Feminino , Ketamina/administração & dosagem , Estrutura Molecular , Medição da Dor , Ratos , Ratos Sprague-Dawley , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Receptores de N-Metil-D-Aspartato/metabolismo , Relação Estrutura-Atividade
11.
Br J Anaesth ; 122(5): 635-642, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30915994

RESUMO

BACKGROUND: EEG activity in the extended alpha frequency range (7-17 Hz) during maintenance of general anaesthesia is primarily determined by effect-site concentrations of the hypnotic and analgesic drugs used. Intermittent alpha loss during surgery, unexplained by changes in anaesthetic or opioid concentrations, could represent arousal of the cortex as a result of increased surgical stimulation. METHODS: A generalised linear model was fitted to alpha power recorded from patients undergoing general anaesthesia from induction until waking using three explanatory variables: age-adjusted volatile anaesthetic effect-site concentration, and estimated effect-site propofol and opioid concentrations. Model residuals were decomposed into uncorrelated white noise and a fluctuating auto-correlated trend. Deviations of this local trend were classified as 'unexpected alpha dropout events'. To investigate whether these alpha dropouts might be explained by the effect of noxious stimulation, we related their occurrence to whether a patient was undergoing surgery involving the body cavity or not. RESULTS: Alpha power dropouts occurred in 73 of the 237 patients included in the final analysis (31%, median amplitude of -3.5 dB, duration=103 s). They showed a bimodal or broadly skewed distribution, being more probable soon after initial incision (32%), dropping to around 10% at 1 h, and then again increasing to >30% in operations lasting >3 h. Multivariate analysis showed that alpha dropouts were significantly associated with body cavity surgery (P=0.003) and with longer operations (P<0.001). CONCLUSIONS: A loss of alpha power, unexplained by changes in anaesthetic or opioid concentrations, is suggestive of thalamocortical depolarisation induced by body cavity noxious stimuli, and could provide a measure of nociception during surgery.


Assuntos
Anestesia Geral/métodos , Anestésicos Gerais/farmacologia , Eletroencefalografia/efeitos dos fármacos , Monitorização Neurofisiológica Intraoperatória/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/farmacologia , Anestésicos Inalatórios/farmacologia , Anestésicos Intravenosos/farmacologia , Córtex Cerebral/efeitos dos fármacos , Córtex Cerebral/fisiologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Propofol/farmacologia , Processamento de Sinais Assistido por Computador , Adulto Jovem
12.
Anesthesiology ; 128(6): 1167-1174, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29509582

RESUMO

BACKGROUND: Ketamine is a general anesthetic thought to act by antagonizing N-methyl-D-aspartate receptors. However, ketamine acts on multiple channels, many of which are potential targets-including hyperpolarization-activated cyclic nucleotide-gated and potassium channels. In this study we tested the hypothesis that potassium leak channels contribute to the anesthetic action of ketamine. METHODS: Adult mouse cortical slices (400 µm) were exposed to no-magnesium artificial cerebrospinal fluid to generate seizure-like event activity. The reduction in seizure-like event frequency after exposure to ketamine (n = 14) was quantified as a signature of anesthetic effect. Pharmacologic manipulation of hyperpolarization-activated cyclic nucleotide-gated and potassium channels using ZD7288 (n = 11), cesium chloride (n = 10), barium chloride (n = 10), low-potassium (1.5 mM) artificial cerebrospinal fluid (n = 10), and urethane (n = 7) were investigated. RESULTS: Ketamine reduced the frequency of seizure-like events (mean [SD], -62 [22]%, P < 0.0001). Selective hyperpolarization-activated cyclic nucleotide-gated channel block with ZD7288 did not significantly alter the potency of ketamine to inhibit seizure-like event activity. The inhibition of seizure-like event frequency by ketamine was fully antagonized by the potassium channel blockers cesium chloride and barium chloride (8 [26]% and 39 [58%] increase, respectively, P < 0.0001, compared to ketamine control) and was facilitated by the potassium leak channel opener urethane (-93 [8]%, P = 0.002 compared to ketamine control) and low potassium artificial cerebrospinal fluid (-86 [11]%, P = 0.004 compared to ketamine control). CONCLUSIONS: The results of this study show that mechanisms additional to hyperpolarization-activated cyclic nucleotide-gated channel block are likely to explain the anesthetic action of ketamine and suggest facilitatory action at two-pore potassium leak channels.


Assuntos
Analgésicos/farmacologia , Córtex Cerebral/efeitos dos fármacos , Córtex Cerebral/fisiologia , Ketamina/farmacologia , Bloqueadores dos Canais de Potássio/farmacologia , Canais de Potássio/fisiologia , Animais , Feminino , Masculino , Potenciais da Membrana/efeitos dos fármacos , Potenciais da Membrana/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Técnicas de Cultura de Órgãos
13.
J Clin Monit Comput ; 31(4): 813-823, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27444893

RESUMO

During emergence from anesthesia patients regain their muscle tone (EMG). In a typical population of surgical patients the actual volatile gas anesthetic concentrations in the brain (CeMAC) at which EMG activation occurs remains unknown, as is whether EMG activation at higher CeMACs is correlated with subsequent severe pain, or with cortical activation. Electroencephalographic (EEG) and EMG activity was recorded from the forehead of 273 patients emerging from general anesthesia following surgery. We determined CeMAC at time of EMG activation and at return of consciousness. Pain was assessed immediately after return of consciousness using an 11 point numerical rating scale. The onset of EMG activation during emergence was associated with neither discernible muscle movement nor with the presence of exogenous stimulation in half the patients. EMG activation could be modelled as two distinct processes; termed high- and low-CeMAC (occurring higher or lower than 0.07 CeMAC). Low-CeMAC activation was typically associated with simultaneous EMG activation and consciousness, and the presence of a laryngeal mask. In contrast, high-CeMAC EMG activation occurred independently of return of consciousness, and was not associated with severe post-operative pain, but was more common in the presence of an endotracheal tube. Patients emerging from general anesthesia with an endotracheal tube in place are more likely to have an EMG activation at higher CeMAC concentrations. These activations are not associated with subsequent high-pain, nor with cortical arousal, as evidenced by continuing delta waves in the EEG. Conversely, patients emerging from general anesthesia with a laryngeal mask demonstrate marked neural inertia-EMG activation occurs at a low CeMAC, and is closely temporally associated with return of consciousness.


Assuntos
Anestesia Geral , Encéfalo/efeitos dos fármacos , Encéfalo/fisiopatologia , Eletromiografia , Monitorização Intraoperatória , Adulto , Idoso , Anestesia , Anestesiologia , Anestésicos Inalatórios , Estado de Consciência , Eletroencefalografia , Processamento Eletrônico de Dados , Feminino , Humanos , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Manejo da Dor , Medição da Dor , Processamento de Sinais Assistido por Computador , Fatores de Tempo
14.
J Clin Monit Comput ; 30(4): 451-66, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26350675

RESUMO

Electroencephalogram (EEG) synchronization is becoming an essential tool to describe neurophysiological mechanisms of communication between brain regions under general anesthesia. Different synchronization measures have their own properties to reflect the changes of EEG activities during different anesthetic states. However, the performance characteristics and the relations of different synchronization measures in evaluating synchronization changes during propofol-induced anesthesia are not fully elucidated. Two-channel EEG data from seven volunteers who had undergone a brief standardized propofol anesthesia were then adopted to calculate eight synchronization indexes. We computed the prediction probability (P K ) of synchronization indexes with Bispectral Index (BIS) and propofol effect-site concentration (C eff ) to quantify the ability of the indexes to predict BIS and C eff . Also, box plots and coefficient of variation were used to reflect the different synchronization changes and their robustness to noise in awake, unconscious and recovery states, and the Pearson correlation coefficient (R) was used for assessing the relationship among synchronization measures, BIS and C eff . Permutation cross mutual information (PCMI) and determinism (DET) could predict BIS and follow C eff better than nonlinear interdependence (NI), mutual information based on kernel estimation (KerMI) and cross correlation. Wavelet transform coherence (WTC) in α and ß frequency bands followed BIS and C eff better than that in other frequency bands. There was a significant decrease in unconscious state and a significant increase in recovery state for PCMI and NI, while the trends were opposite for KerMI, DET and WTC. Phase synchronization based on phase locking value (PSPLV) in δ, θ, α and γ1 frequency bands dropped significantly in unconscious state, whereas it had no significant synchronization in recovery state. Moreover, PCMI, NI, DET correlated closely with each other and they had a better robustness to noise and higher correlation with BIS and C eff than other synchronization indexes. Propofol caused EEG synchronization changes during the anesthetic period. Different synchronization measures had individual properties in evaluating synchronization changes in different anesthetic states, which might be related to various forms of neural activities and neurophysiological mechanisms under general anesthesia.


Assuntos
Anestésicos Intravenosos/administração & dosagem , Eletroencefalografia/estatística & dados numéricos , Propofol/administração & dosagem , Algoritmos , Anestesia Intravenosa/estatística & dados numéricos , Humanos , Monitorização Neurofisiológica Intraoperatória/estatística & dados numéricos
15.
J Clin Monit Comput ; 28(4): 409-17, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24414381

RESUMO

The electroencephalogram (EEG) has been widely applied in the assessment of depth of anesthesia (DoA). Recent research has found that multi-scale EEG analysis describes brain dynamics better than traditional non-linear methods. In this study, we have adopted a modified sample entropy (MSpEn) method to analyze anesthetic EEG series as a measure of DoA. EEG data from a previous study consisting of 19 adult subjects undergoing sevoflurane anesthesia were used in the present investigation. In addition to the modified sample entropy method, the well-established EEG indices approximate entropy (ApEn), response entropy (RE), and state entropy (SE) were also computed for comparison. Pharmacokinetic/pharmacodynamic modeling and prediction probability (P k ) were used to assess and compare the performance of the four methods for tracking anesthetic concentration. The influence of the number of scales on MSpEn was also investigated using a linear regression model. MSpEn correlated closely with anesthetic effect. The P k (0.83 ± 0.05, mean ± SD) and the coefficient of determination R (2) (0.87 ± 0.21) for the relationship between MSpEn and sevoflurane effect site concentration were highest for MSpEn (P k : RE = 0.73 ± 0.08, SE = 0.72 ± 0.07, ApEn = 0.81 ± 0.04; R (2): RE = 0.75 ± 0.08, SE = 0.64 ± 0.09, ApEn = 0.81 ± 0.10). Scales 1, 3 and 5 tended to make the greatest contribution to MSpEn. For this data set, the MSpEn is superior to the ApEn, the RE and the SE for tracking drug concentration change during sevoflurane anesthesia. It is suggested that the MSpEn may be further studied for application in clinical monitoring of DoA.


Assuntos
Algoritmos , Encéfalo/efeitos dos fármacos , Encéfalo/fisiopatologia , Estado de Consciência/efeitos dos fármacos , Diagnóstico por Computador/métodos , Eletroencefalografia/métodos , Éteres Metílicos/administração & dosagem , Adolescente , Adulto , Anestesia por Inalação/métodos , Anestésicos Inalatórios/administração & dosagem , Interpretação Estatística de Dados , Entropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Sevoflurano , Adulto Jovem
16.
A A Pract ; 18(7): e01813, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38975674

RESUMO

Incomplete neurological awakening manifested as aberrant patterns of electroencephalography (EEG) at emergence may be responsible for an unresponsive patient in the postanesthesia care unit (PACU). We describe a case of an individual who remained unresponsive but awake in the PACU. Retrospective, intraoperative EEG analysis showed low alpha power and a sudden shift from deep delta to arousal preextubation. We explored parallels with diminished motivation disorders and anesthesia-induced sleep paralysis due to imbalances in anesthetic drug sensitivity between brain regions. Our findings highlight the relevance of end-anesthesia EEG patterns in diagnosing delayed awakening.


Assuntos
Eletroencefalografia , Humanos , Período de Recuperação da Anestesia , Idoso , Masculino , Feminino , Idoso de 80 Anos ou mais
17.
Anaesth Intensive Care ; 52(1): 37-44, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37712714

RESUMO

Jet injection is a drug delivery system without a needle. A compressed liquid drug formulation pierces the skin, depositing the drug into the subcutaneous or intramuscular tissues. We investigated the pharmacokinetics and patient experience of dexmedetomidine administered using jet injection in six healthy adult study participants. This needleless jet injection device was used to administer dexmedetomidine 0.5 µg/kg to the subcutaneous tissues overlying the deltoid muscle. Serum concentrations of dexmedetomidine were assayed at approximately 5 minutes, 15 minutes, 30 minutes, 1 hour and 4 hours after administration. Pharmacokinetic interrogation of concentration time profiles estimated an absorption half time for jet-injected dexmedetomidine of 21 minutes (coefficient of variation 69.4%) with a relative bioavailability assumed unity. In our samples the measured median peak (range) concentration was 0.164 µg/l (0.011-0.325 µg/l), observed in the sample taken at a median (range) of 13.5 minutes (11-30 minutes). The Richmond agitation sedation scale was used to assess the sedative effect, and scored 0 (alert and calm) or -1 (drowsy) in all participants. Five of the six participants stated they would prefer jet injection to needle injection in the future and one had no preference. The findings suggest that the use of a larger dose (>2 µg/kg) would be required to achieve the clinically relevant target concentration of 1 µg/l necessary to achieve deeper sedation (Richmond agitation sedation scale ≤3).


Assuntos
Dexmedetomidina , Adulto , Humanos , Hipnóticos e Sedativos , Injeções a Jato , Pressão , Avaliação de Resultados da Assistência ao Paciente
18.
BMC Neurosci ; 14: 137, 2013 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-24195598

RESUMO

BACKGROUND: In cortical and hippocampal brain slice experiments, the viability of processed tissue is usually judged by the amplitude of extracellularly-recorded seizure-like event (SLE) activity. Surprisingly, the suitability of this approach for evaluating slice quality has not been objectively studied. Furthermore, a method for gauging the viability of quiescent tissue, in which SLE activity is intentionally suppressed, has not been documented. In this study we undertook to address both of these matters using the zero-magnesium SLE model in neocortical slices. METHODS: Using zero-magnesium SLE activity as the output parameter, we investigated: 1) changes in the pattern (amplitude, frequency and length) of SLE activity as slice health either deteriorated; or was compromised by altering the preparation methodology and; 2) in quiescent tissue, whether the triggering of high frequency field activity following electrode insertion predicted subsequent development of SLE activity - and hence slice viability. RESULTS: SLE amplitude was the single most important variable correlating with slice viability, with a value less than 50 µV indicative of tissue unlikely to be able to sustain population activity for more than 30-60 minutes. In quiescent slices, an increase in high frequency field activity immediately after electrode insertion predicted the development of SLE activity in 100% of cases. Furthermore, the magnitude of the increase in spectral power correlated with the amplitude of succeeding SLE activity (R2 40.9%, p < 0.0001). CONCLUSION: In conclusion, the findings confirm that the amplitude of population activity is a suitable field potential parameter for judging brain slice viability - and can be applied independent of the mechanism of tissue activation.


Assuntos
Sobrevivência Celular , Eletrofisiologia/métodos , Neocórtex/fisiologia , Potenciais de Ação , Animais , Feminino , Masculino , Camundongos , Técnicas de Cultura de Órgãos
19.
Anesthesiology ; 119(1): 81-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23508217

RESUMO

BACKGROUND: The exact neurophysiological mechanisms of anesthetic-induced unconsciousness are not yet fully elucidated. The cortical information integration theory hypothesizes that loss of consciousness during general anesthesia is associated with breakdown of long-distance cortical connectivity across multiple brain regions. However, what is the effect of anesthetics on neural activities at a smaller spatial scale? METHODS: The authors analyzed a set of previously published eight-channel electrocorticogram data, obtained from a 14-mm-long linear array of electrodes in eight adult merino sheep during general anesthesia induced by sevoflurane, desflurane, isoflurane, and enflurane. The S-estimator was applied to the bi-channel coherence matrix to construct an overall index called the SI, which is the entropy of the eigenvalues of the cortical coherence for each pair of channels within the multichannel electrocorticographic dataset. RESULTS: The SI values increased ~30-50% from the waking to the burst-suppression states, and returned to baseline during recovery. The anesthetic-induced increase in synchrony was most marked in the α (8-13 Hz) and ß (13-30 Hz) frequency bands (P<0.05). Using prediction probability (PK) analysis, we found a significant correlation between the increase in spatial synchrony (as estimated by the SI at various frequency bands) and anesthetic-induced cortical depression (as estimated by the approximate entropy). CONCLUSIONS: The results suggest that it is feasible to use the SI to measure cortical synchrony, and over a local spatial scale of 2-14 mm, synchrony increased during general anesthesia.


Assuntos
Anestésicos Inalatórios/farmacologia , Encéfalo/efeitos dos fármacos , Sincronização Cortical/efeitos dos fármacos , Ovinos/fisiologia , Algoritmos , Análise de Variância , Anestesia por Inalação , Animais , Eletroencefalografia/efeitos dos fármacos , Entropia
20.
Bioorg Med Chem ; 21(17): 5098-106, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23876339

RESUMO

A series of aliphatic esters of the non-opioid anaesthetic/analgesic ketamine were prepared and their properties as shorter-acting analogues of ketamine itself were explored in an infused rat model, measuring the time after infusion to recover from both the anaesthetic (righting reflex) and analgesic (response to stimulus) effects. The potency of the esters as sedatives was not significantly related to chain length, but Me, Et and i-Pr esters were the more dose potent (up to twofold less than ketamine), whereas n-Pr esters were less potent (from 2- to 6-fold less than ketamine). For the Me, Et and i-Pr esters recovery from anaesthesia was 10-15-fold faster than from ketamine itself, and for the n-Pr esters it was 20-25-fold faster than from ketamine. A new dimethylamino ketamine derivative (homoketamine) had ketamine-like sedative effects but was slightly less potent than, but ester analogues of homoketamine had very weak sedative effects.


Assuntos
Analgésicos/química , Ketamina/química , Analgésicos/síntese química , Analgésicos/farmacologia , Animais , Ésteres , Feminino , Frequência Cardíaca/efeitos dos fármacos , Ketamina/síntese química , Ketamina/farmacologia , Ratos , Ratos Sprague-Dawley , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA