Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 48(3): 731-746, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32935187

RESUMO

PURPOSES: We present the first in-human brain PET imaging data of the new α4ß2 nicotinic acetylcholine receptor (nAChR)-targeting radioligand (+)-[18F]Flubatine. Aims were to develop a kinetic modeling-based approach to quantify (+)-[18F]Flubatine and compare the data of healthy controls (HCs) and patients with Alzheimer's disease (AD); to investigate the partial volume effect (PVE) on regional (+)-[18F]Flubatine binding; and whether (+)-[18F]Flubatine binding and cognitive test data respective ß-amyloid radiotracer accumulation were correlated. METHODS: We examined 11 HCs and 9 mild AD patients. All subjects underwent neuropsychological testing and [11C]PiB PET/MRI examination. (+)-[18F]Flubatine PET data were evaluated using full kinetic modeling and regional as well as voxel-based analyses. RESULTS: With 270-min p.i., the unchanged parent compound amounted to 97 ± 2%. Adequate fits of the time-activity curves were obtained with the 1 tissue compartment model (1TCM). (+)-[18F]Flubatine distribution volume (binding) was significantly reduced in bilateral mesial temporal cortex in AD patients compared with HCs (right 10.6 ± 1.1 vs 11.6 ± 1.4, p = 0.049; left 11.0 ± 1.1 vs 12.2 ± 1.8, p = 0.046; one-sided t tests each). PVE correction increased not only (+)-[18F]Flubatine binding of approximately 15% but also standard deviation of 0.4-70%. Cognitive test data and (+)-[18F]Flubatine binding were significantly correlated in the left anterior cingulate, right posterior cingulate, and right parietal cortex (r > 0.5, p < 0.05 each). In AD patients, (+)-[18F]Flubatine binding and [11C]PiB standardized uptake value ratios were negatively correlated in several regions; whereas in HCs, a positive correlation between cortical (+)-[18F]Flubatine binding and [11C]PiB accumulation in the white matter was found. No adverse event related to (+)-[18F]Flubatine occurred. CONCLUSION: (+)-[18F]Flubatine is a safe and stable PET ligand. Full kinetic modeling can be realized by 1TCM without metabolite correction. (+)-[18F]Flubatine binding affinity was high enough to detect group differences. Of interest, correlation between white matter ß-amyloid PET uptake and (+)-[18F]Flubatine binding indicated an association between white matter integrity and availability of α4ß2 nAChRs. Overall, (+)-[18F]Flubatine showed favorable characteristics and has therefore the potential to serve as α4ß2 nAChR-targeting PET ligand in further clinical trials.


Assuntos
Doença de Alzheimer , Doença de Alzheimer/diagnóstico por imagem , Peptídeos beta-Amiloides , Compostos de Anilina , Benzamidas , Encéfalo/diagnóstico por imagem , Compostos Bicíclicos Heterocíclicos com Pontes , Humanos , Ligantes , Neuroimagem , Tomografia por Emissão de Pósitrons , Receptores Nicotínicos
2.
Brain ; 141(6): 1840-1854, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29672680

RESUMO

In early Alzheimer's dementia, there is a need for PET biomarkers of disease progression with close associations to cognitive dysfunction that may aid to predict further cognitive decline and neurodegeneration. Amyloid biomarkers are not suitable for that purpose. The α4ß2 nicotinic acetylcholine receptors (α4ß2-nAChRs) are widely abundant in the human brain. As neuromodulators they play an important role in cognitive functions such as attention, learning and memory. Post-mortem studies reported lower expression of α4ß2-nAChRs in more advanced Alzheimer's dementia. However, there is ongoing controversy whether α4ß2-nAChRs are reduced in early Alzheimer's dementia. Therefore, using the recently developed α4ß2-nAChR-specific radioligand (-)-18F-flubatine and PET, we aimed to quantify the α4ß2-nAChR availability and its relationship to specific cognitive dysfunction in mild Alzheimer's dementia. Fourteen non-smoking patients with mild Alzheimer's dementia, drug-naïve for cholinesterase therapy, were compared with 15 non-smoking healthy controls matched for age, sex and education by applying (-)-18F-flubatine PET together with a neuropsychological test battery. The one-tissue compartment model and Logan plot method with arterial input function were used for kinetic analysis to obtain the total distribution volume (VT) as the primary, and the specific binding part of the distribution volume (VS) as the secondary quantitative outcome measure of α4ß2-nAChR availability. VS was determined by using a pseudo-reference region. Correlations between VT within relevant brain regions and Z-scores of five cognitive functions (episodic memory, executive function/working memory, attention, language, visuospatial function) were calculated. VT (and VS) were applied for between-group comparisons. Volume of interest and statistical parametric mapping analyses were carried out. Analyses revealed that in patients with mild Alzheimer's dementia compared to healthy controls, there was significantly lower VT, especially within the hippocampus, fronto-temporal cortices, and basal forebrain, which was similar to comparisons of VS. VT decline in Alzheimer's dementia was associated with distinct domains of impaired cognitive functioning, especially episodic memory and executive function/working memory. Using (-)-18F-flubatine PET in patients with mild Alzheimer's dementia, we show for the first time a cholinergic α4ß2-nAChR deficiency mainly present within the basal forebrain-cortical and septohippocampal cholinergic projections and a relationship between lower α4ß2-nAChR availability and impairment of distinct cognitive domains, notably episodic memory and executive function/working memory. This shows the potential of (-)-18F-flubatine as PET biomarker of cholinergic α4ß2-nAChR dysfunction and specific cognitive decline. Thus, if validated by longitudinal PET studies, (-)-18F-flubatine might become a PET biomarker of progression of neurodegeneration in Alzheimer's dementia.


Assuntos
Doença de Alzheimer/complicações , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/metabolismo , Receptores Nicotínicos/metabolismo , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/diagnóstico por imagem , Atenção/fisiologia , Benzamidas/farmacocinética , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Compostos Bicíclicos Heterocíclicos com Pontes/farmacocinética , Transtornos Cognitivos/diagnóstico por imagem , Estudos de Coortes , Escolaridade , Função Executiva , Feminino , Humanos , Masculino , Memória de Curto Prazo/fisiologia , Pessoa de Meia-Idade , Testes Neuropsicológicos , Tomografia por Emissão de Pósitrons , Fatores Sexuais
3.
Neuroimage ; 118: 199-208, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26037057

RESUMO

α4ß2* nicotinic receptors (α4ß2* nAChRs) could provide a biomarker in neuropsychiatric disorders (e.g., Alzheimer's and Parkinson's diseases, depressive disorders, and nicotine addiction). However, there is a lack of α4ß2* nAChR specific PET radioligands with kinetics fast enough to enable quantification of nAChR within a reasonable time frame. Following on from promising preclinical results, the aim of the present study was to evaluate for the first time in humans the novel PET radioligand (-)-[(18)F]Flubatine, formerly known as (-)-[(18)F]NCFHEB, as a tool for α4ß2* nAChR imaging and in vivo quantification. Dynamic PET emission recordings lasting 270min were acquired on an ECAT EXACT HR+ scanner in 12 healthy male non-smoking subjects (71.0±5.0years) following the intravenous injection of 353.7±9.4MBq of (-)-[(18)F]Flubatine. Individual magnetic resonance imaging (MRI) was performed for co-registration. PET frames were motion-corrected, before the kinetics in 29 brain regions were characterized using 1- and 2-tissue compartment models (1TCM, 2TCM). Given the low amounts of metabolite present in plasma, we tested arterial input functions with and without metabolite corrections. In addition, pixel-based graphical analysis (Logan plot) was used. The model's goodness of fit, with and without metabolite correction was assessed by Akaike's information criterion. Model parameters of interest were the total distribution volume VT (mL/cm(3)), and the binding potential BPND relative to the corpus callosum, which served as a reference region. The tracer proved to have high stability in vivo, with 90% of the plasma radioactivity remaining as untransformed parent compound at 90min, fast brain kinetics with rapid uptake and equilibration between free and receptor-bound tracer. Adequate fits of brain TACs were obtained with the 1TCM. VT could be reliably estimated within 90min for all regions investigated, and within 30min for low-binding regions such as the cerebral cortex. The rank order of VT by region corresponded well with the known distribution of α4ß2* receptors (VT [thalamus] 27.4±3.8, VT [putamen] 12.7±0.9, VT [frontal cortex] 10.0±0.8, and VT [corpus callosum] 6.3±0.8). The BPND, which is a parameter of α4ß2* nAChR availability, was 3.41±0.79 for the thalamus, 1.04±0.25 for the putamen and 0.61±0.23 for the frontal cortex, indicating high specific tracer binding. Use of the arterial input function without metabolite correction resulted in a 10% underestimation in VT, and was without important biasing effects on BPND. Altogether, kinetics and imaging properties of (-)-[(18)F]Flubatine appear favorable and suggest that (-)-[(18)F]Flubatine is a very suitable and clinically applicable PET tracer for in vivo imaging of α4ß2* nAChRs in neuropsychiatric disorders.


Assuntos
Benzamidas/farmacocinética , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Compostos Bicíclicos Heterocíclicos com Pontes/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Receptores Nicotínicos/metabolismo , Idoso , Benzamidas/efeitos adversos , Benzamidas/sangue , Compostos Bicíclicos Heterocíclicos com Pontes/efeitos adversos , Compostos Bicíclicos Heterocíclicos com Pontes/sangue , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
4.
MAGMA ; 26(1): 99-113, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23179594

RESUMO

In current combined PET/MR systems, PET attenuation correction is based on MRI, since the small bore inside MRI systems and the strong magnetic field do not permit a rotating PET transmission source or a CT device to be integrated. Unlike CT measurements in PET/CT scanners, the MR signal is not directly correlated to tissue density and thus cannot be converted by a simple transformation of intensity values. Various approaches have been developed based on templates, atlas information, direct segmentation of T1-weighted MR images, or segmentation of images from special MR sequences. The advantages and disadvantages of these approaches as well as additional challenges will be discussed in this review.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Desenho de Equipamento , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Compostos Radiofarmacêuticos , Imagem Corporal Total
5.
Nucl Med Biol ; 41(6): 489-94, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24768146

RESUMO

INTRODUCTION: (-)-[(18)F]Flubatine is a PET tracer with high affinity and selectivity for the nicotinic acetylcholine α4ß2 receptor subtype. A clinical trial assessing the availability of this subtype of nAChRs was performed. From a total participant number of 21 Alzheimer's disease (AD) patients and 20 healthy controls (HCs), the following parameters were determined: plasma protein binding, metabolism and activity distribution between plasma and whole blood. METHODS: Plasma protein binding and fraction of unchanged parent compound were assessed by ultracentrifugation and HPLC, respectively. The distribution of radioactivity (parent compound+metabolites) between plasma and whole blood was determined ex vivo at different time-points after injection by gamma counting after separation of whole blood by centrifugation into the cellular and non-cellular components. In additional experiments in vitro, tracer distribution between these blood components was assessed for up to 90min. RESULTS: A fraction of 15%±2% of (-)-[(18)F]Flubatine was found to be bound to plasma proteins. Metabolic degradation of (-)-[(18)F]Flubatine was very low, resulting in almost 90% unchanged parent compound at 90min p.i. with no significant difference between AD and HC. The radioactivity distribution between plasma and whole blood changed in vivo only slightly over time from 0.82±0.03 at 3min p.i. to 0.87±0.03 at 270min p.i. indicating the contribution of only a small amount of metabolites. In vitro studies revealed that (-)-[(18)F]Flubatine was instantaneously distributed between cellular and non-cellular blood parts. DISCUSSION: (-)-[(18)F]Flubatine exhibits very favourable characteristics for a PET radiotracer such as slow metabolic degradation and moderate plasma protein binding. Equilibrium of radioactivity distribution between plasma and whole blood is reached instantaneously and remains almost constant over time allowing both convenient sample handling and facilitated fractional blood volume contribution assessment.


Assuntos
Benzamidas/administração & dosagem , Benzamidas/metabolismo , Proteínas Sanguíneas/metabolismo , Compostos Bicíclicos Heterocíclicos com Pontes/administração & dosagem , Compostos Bicíclicos Heterocíclicos com Pontes/metabolismo , Benzamidas/sangue , Compostos Bicíclicos Heterocíclicos com Pontes/sangue , Humanos , Cinética , Ligação Proteica , Traçadores Radioativos
6.
Curr Med Imaging Rev ; 9(2): 79-88, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24078804

RESUMO

Medical image processing provides core innovation for medical imaging. This paper is focused on recent developments from science to applications analyzing the past fifteen years of history of the proceedings of the German annual meeting on medical image processing (BVM). Furthermore, some members of the program committee present their personal points of views: (i) multi-modality for imaging and diagnosis, (ii) analysis of diffusion-weighted imaging, (iii) model-based image analysis, (iv) registration of section images, (v) from images to information in digital endoscopy, and (vi) virtual reality and robotics. Medical imaging and medical image computing is seen as field of rapid development with clear trends to integrated applications in diagnostics, treatment planning and treatment.

7.
Appl Radiat Isot ; 80: 7-11, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23792828

RESUMO

A fully automatized radiosynthesis of (+)- and (-)-[(18)F]Flubatine ((+)- and (-)NCFHEB) by means of a commercially available synthesis module (TRACERlab FX FN) under GMP conditions is reported. Radiochemical yields of 30% within an overall synthesis time of 40 min were achieved in more than 70 individual syntheses. Specific activities were approximately 3000 GBq/µmol and radiochemical purity was determined to be at least 97%.


Assuntos
Automação , Benzamidas/síntese química , Compostos Bicíclicos Heterocíclicos com Pontes/síntese química , Radioisótopos de Flúor/química , Benzamidas/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Cromatografia Líquida de Alta Pressão , Humanos , Controle de Qualidade , Estereoisomerismo
8.
Artigo em Inglês | MEDLINE | ID: mdl-17354787

RESUMO

We describe a new method to reconstruct human brain structures from 3D magnetic resonance brain images. Our method provides a fully automatic topology correction mechanism, thus avoiding tedious manual correction. Topological correctness is important because it is an essential prerequisite for brain atlas deformation and surface flattening. Our method uses an axis-aligned sweep through the volume to locate handles. Handles are detected by successively constructing and analyzing a directed graph. A multiple local region-growing process is used which simultaneously acts on the foreground and the background to isolate handles and tunnels. The sizes of handles and tunnels are measured, then handles are removed or tunnels filled based on their sizes. This process was used for 256 T1-weighted MR volumes.


Assuntos
Inteligência Artificial , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
9.
Artigo em Inglês | MEDLINE | ID: mdl-16685975

RESUMO

This paper describes an automatic parameter optimization method for anisotropic diffusion filters used to de-noise 2D and 3D MR images. The filtering process is integrated into a closed-loop system where image improvement is monitored indirectly by comparing the characteristics of the suppressed noise with those of the assumed noise model at the optimal point. In order to verify the performance of this approach, experimental results obtained with this method are presented together with the results obtained by median and k-nearest neighbor filters.


Assuntos
Algoritmos , Artefatos , Inteligência Artificial , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA