Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Artif Organs ; 43(2): 159-166, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30084492

RESUMO

The most common technical complication during ECMO is clot formation. A large clot inside a membrane oxygenator reduces effective membrane surface area and therefore gas transfer capabilities, and restricts blood flow through the device, resulting in an increased membrane oxygenator pressure drop (dpMO). The reasons for thrombotic events are manifold and highly patient specific. Thrombus formation inside the oxygenator during ECMO is usually unpredictable and remains an unsolved problem. Clot sizes and positions are well documented in literature for the Maquet Quadrox-i Adult oxygenator based on CT data extracted from devices after patient treatment. Based on this data, the present study was designed to investigate the effects of large clots on purely technical parameters, for example, dpMO and gas transfer. Therefore, medical grade silicone was injected into the fiber bundle of the devices to replicate large clot positions and sizes. A total of six devices were tested in vitro with silicone clot volumes of 0, 30, 40, 50, 65, and 85 mL in accordance with ISO 7199. Gas transfer was measured by sampling blood pre and post device, as well as by sampling the exhaust gas at the devices' outlet at blood flow rates of 0.5, 2.5, and 5.0 L/min. Pre and post device pressure was monitored to calculate the dpMO at the different blood flow rates. The dpMO was found to be a reliable parameter to indicate a large clot only in already advanced "clotting stages." The CO2 concentration in the exhaust gas, however, was found to be sensitive to even small clot sizes and at low blood flows. Exhaust gas CO2 concentration can be monitored continuously and without any risks for the patient during ECMO therapy to provide additional information on the endurance of the oxygenator. This may help detect a clot formation and growth inside a membrane oxygenator during ECMO even if the increase in dpMO remains moderate.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenadores de Membrana/efeitos adversos , Trombose/diagnóstico , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Desenho de Equipamento , Hemodinâmica , Humanos , Índice de Gravidade de Doença , Trombose/etiologia
2.
Microorganisms ; 11(4)2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37110260

RESUMO

Organic olvent-tolerant strains of the Gram-negative bacterial genus Pseudomonas are discussed as potential biocatalysts for the biotechnological production of various chemicals. However, many current strains with the highest tolerance are belonging to the species P. putida and are classified as biosafety level 2 strains, which makes them uninteresting for the biotechnological industry. Therefore, it is necessary to identify other biosafety level 1 Pseudomonas strains with high tolerance towards solvents and other forms of stress, which are suitable for establishing production platforms of biotechnological processes. In order to exploit the native potential of Pseudomonas as a microbial cell factory, the biosafety level 1 strain P. taiwanensis VLB120 and its genome-reduced chassis (GRC) variants as well as the plastic-degrading strain P. capeferrum TDA1 were assessed regarding their tolerance towards different n-alkanols (1-butanol, 1-hexanol, 1-octanol, 1-decanol). Toxicity of the solvents was investigated by their effects on bacterial growth rates given as the EC50 concentrations. Hereby, both toxicities as well as the adaptive responses of P. taiwanensis GRC3 and P. capeferrum TDA1 showed EC50 values up to two-fold higher than those previously detected for P. putida DOT-T1E (biosafety level 2), one of the best described solvent-tolerant bacteria. Furthermore, in two-phase solvent systems, all the evaluated strains were adapted to 1-decanol as a second organic phase (i.e., OD560 was at least 0.5 after 24 h of incubation with 1% (v/v) 1-decanol), which shows the potential use of these strains as platforms for the bio-production of a wide variety of chemicals at industrial level.

3.
Membranes (Basel) ; 12(2)2022 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-35207055

RESUMO

Extracorporeal membrane oxygenation (ECMO) is an established rescue therapy for patients with chronic respiratory failure waiting for lung transplantation (LTx). The therapy inherent immobilization may result in fatigue, consecutive deteriorated prognosis, and even lost eligibility for transplantation. We conducted a feasibility study on a novel system designed for the deployment of a portable ECMO device, enabling the physical exercise of awake patients prior to LTx. The system comprises a novel oxygenator with a directly connected blood pump, a double-lumen cannula, gas blender and supply, as well as control and energy management. In vitro experiments included tests regarding performance, efficiency, and blood damage. A reduced system was tested in vivo for feasibility using a novel large animal model. Six anesthetized pigs were first positioned in supine position, followed by a 45° angle, simulating an upright position of the patients. We monitored performance and vital parameters. All in vitro experiments showed good performance for the respective subsystems and the integrated system. The acute in vivo trials of 8 h duration confirmed the results. The novel portable ECMO-system enables adequate oxygenation and decarboxylation sufficient for, e.g., the physical exercise of designated LTx-recipients. These results are promising and suggest further preclinical studies on safety and efficacy to facilitate translation into clinical application.

4.
PLoS One ; 16(11): e0260002, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34780548

RESUMO

Bacterial degradation of xenobiotic compounds is an intense field of research already for decades. Lately, this research is complemented by downstream applications including Next Generation Sequencing (NGS), RT-PCR, qPCR, and RNA-seq. For most of these molecular applications, high-quality RNA is a fundamental necessity. However, during the degradation of aromatic substrates, phenolic or polyphenolic compounds such as polycatechols are formed and interact irreversibly with nucleic acids, making RNA extraction from these sources a major challenge. Therefore, we established a method for total RNA extraction from the aromatic degrading Pseudomonas capeferrum TDA1 based on RNAzol® RT, glycogen and a final cleaning step. It yields a high-quality RNA from cells grown on TDA1 and on phenol compared to standard assays conducted in the study. To our knowledge, this is the first report tackling the problem of polyphenolic compound interference with total RNA isolation in bacteria. It might be considered as a guideline to improve total RNA extraction from other bacterial species.


Assuntos
Meios de Cultura/química , Poliuretanos/química , Pseudomonas/crescimento & desenvolvimento , RNA Bacteriano/isolamento & purificação , Fenol/química , Fenilenodiaminas/química , Pseudomonas/genética , RNA Bacteriano/normas , Xenobióticos/química
5.
Membranes (Basel) ; 12(1)2021 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-35054581

RESUMO

Carbon monoxide (CO) poisoning is the leading cause of poisoning-related deaths globally. The currently available therapy options are normobaric oxygen (NBO) and hyperbaric oxygen (HBO). While NBO lacks in efficacy, HBO is not available in all areas and countries. We present a novel method, extracorporeal hyperoxygenation therapy (EHT), for the treatment of CO poisoning that eliminates the CO by treating blood extracorporeally at elevated oxygen partial pressure. In this study, we proof the principle of the method in vitro using procine blood: Firstly, we investigated the difference in the CO elimination of a hollow fibre membrane oxygenator and a specifically designed batch oxygenator based on the bubble oxygenator principle at elevated pressures (1, 3 bar). Secondly, the batch oxygenator was redesigned and tested for a broader range of pressures (1, 3, 5, 7 bar) and temperatures (23, 30, 37 °C). So far, the shortest measured carboxyhemoglobin half-life in the blood was 21.32 min. In conclusion, EHT has the potential to provide an easily available and effective method for the treatment of CO poisoning.

6.
ASAIO J ; 66(6): 683-690, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31789656

RESUMO

Wearable extracorporeal membrane oxygenation (ECMO) circuits may soon become a viable alternative to conventional ECMO treatment. Common device-induced complications, however, such as blood trauma and oxygenator thrombosis, must first be addressed to improve long-term reliability, since ambulatory patients cannot be monitored as closely as intensive care patients. Additionally, an efficient use of the membrane surface can reduce the size of the devices, priming volume, and weight to achieve portability. Both challenges are linked to the hemodynamics in the fiber bundle. While experimental test methods can often only provide global and time-averaged information, computational fluid dynamics (CFD) can give insight into local flow dynamics and gas transfer before building the first laboratory prototype. In this study, we applied our previously introduced micro-scale CFD model to the full fiber bundle of a small oxygenator for gas transfer prediction. Three randomized geometries as well as a staggered and in-line configuration were modeled and simulated with Ansys CFX. Three small laboratory oxygenator prototypes were built by stacking fiber segments unidirectionally with spacers between consecutive segments. The devices were tested in vitro for gas transfer with porcine blood in accordance with ISO 7199. The error of the predicted averaged CFD oxygen saturations of the random 1, 2, and 3 configurations relative to the averaged in-vitro data (over all samples and devices) was 2.4%, 4.6%, 3.1%, and 3.0% for blood flow rates of 100, 200, 300, and 400 ml/min, respectively. While our micro-scale CFD model was successfully applied to a small oxygenator with unidirectional fibers, the application to clinically relevant oxygenators will remain challenging due to the complex flow distribution in the fiber bundle and high computational costs. However, we will outline our future research priorities and discuss how an extended mass transfer correlation model implemented into CFD might enable an a priori prediction of gas transfer in full size oxygenators.


Assuntos
Simulação por Computador , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/instrumentação , Hidrodinâmica , Oxigenadores de Membrana , Animais , Hemodinâmica/fisiologia , Humanos , Suínos
7.
Lab Chip ; 16(7): 1272-3, 2016 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-26956695

RESUMO

This comment on an article that appeared in this journal (Potkay, Lab Chip, 2014, 14, 4122-4138) presents an alternative view on the feasibility and clinical application of current microfluidic artificial lungs.


Assuntos
Órgãos Artificiais , Pulmão/fisiologia , Técnicas Analíticas Microfluídicas , Humanos
8.
Biomed Tech (Berl) ; 59(2): 135-45, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24523303

RESUMO

The ultimate objective of university research and development projects is usually to create knowledge, but also to successfully transfer results to industry for subsequent marketing. We hypothesized that the university technology transfer requires efficient measures to improve this important step. Besides good scientific practice, foresighted and industry-specific adapted documentation of research processes in terms of a quality management system might improve the technology transfer. In order to bridge the gap between research institute and cooperating industry, a model project has been accompanied by a project specific amount of quality management. However, such a system had to remain manageable and must not constrain the researchers' creativity. Moreover, topics and research team are strongly interdisciplinary, which entails difficulties regarding communication because of different perspectives and terminology. In parallel to the technical work of the model project, an adaptable quality management system with a quality manual, defined procedures, and forms and documents accompanying the research, development and validation was implemented. After process acquisition and analysis the appropriate amount of management for the model project was identified by a self-developed rating system considering project characteristics like size, innovation, stakeholders, interdisciplinarity, etc. Employees were trained according to their needs. The management was supported and the technical documentation was optimized. Finally, the quality management system has been transferred successfully to further projects.


Assuntos
Equipamentos e Provisões/normas , Guias como Assunto , Pesquisa/organização & administração , Transferência de Tecnologia , Gestão da Qualidade Total/organização & administração , Pesquisa Translacional Biomédica/organização & administração , Universidades/organização & administração , Alemanha
9.
Biomed Tech (Berl) ; 59(2): 125-33, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24327525

RESUMO

Extracorporeal life support (ECLS) is a well-established technique for the treatment of different cardiac and pulmonary diseases, e.g., congenital heart disease and acute respiratory distress syndrome. Additionally, severely ill patients who cannot be weaned from the heart-lung machine directly after surgery have to be put on ECLS for further therapy. Although both systems include identical components, a seamless transition is not possible yet. The adaption of the circuit to the patients' size and demand is limited owing to the components available. The project I³-Assist aims at a novel concept for extracorporeal circulation. To better match the patient's therapeutic demand of support, an individual number of one-size oxygenators and heat exchangers will be combined. A seamless transition between cardiopulmonary bypass and ECLS will be possible as well as the exchange of components during therapy to enhance circuit maintenance throughout long-term support. Until today, a novel oxygenator and heat exchanger along with a simplified manufacturing protocol have been established. The first layouts of the unit to allow the spill- and bubble-free connection and disconnection of modules as well as improved cannulas and a rotational pump are investigated using computational fluid dynamics. Tests were performed according to current guidelines in vitro and in vivo. The test results show the feasibility and potential of the concept.


Assuntos
Circulação Extracorpórea/instrumentação , Máquina Coração-Pulmão , Terapia Assistida por Computador/instrumentação , Interface Usuário-Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Circulação Extracorpórea/métodos , Estudos de Viabilidade , Humanos , Integração de Sistemas , Terapia Assistida por Computador/métodos
10.
J Mol Spectrosc ; 207(1): 4-9, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11336514

RESUMO

Pure rotational transitions of the chlorine monoxide radical have been observed up to v=2 in the X(1) (2)Pi(3/2) and X(2) (2)Pi(1/2) states and transitions of the (35)Cl(18)O isotopomer have been observed in natural abundance. Additionally, rotational transitions for levels up to J'=115/2 have been measured in the far infrared. These data have been merged with the existing microwave, submillimeter, and high-resolution infrared transition frequencies and fit simultaneously with a set of isotopically independent parameters. Isotopic substitution of both the Cl and O atoms has enabled the first determination of the electron spin-rotation constant gamma=-296.0(43) MHz as well as the Born-Oppenheimer corrections to the rotational constants. Copyright 2001 Academic Press.

SELEÇÃO DE REFERÊNCIAS