Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38960139

RESUMO

BACKGROUND: Acute unreconstructible 3- or 4-part proximal humerus fractures can be treated with hemiarthroplasty or reverse polarity shoulder arthroplasty. Randomized trials using implants from multiple different companies or uncemented implants have found superior results with reverse polarity arthroplasty. AIMS: This study aims to determine whether cemented reverse polarity arthroplasty produces a superior outcome compared to cemented hemiarthroplasty using one implant system in patients aged 65 years and over at 12 months follow-up as measured with the Constant score. METHODS: A prospective patient and assessor blinded multicenter randomized controlled trial was conducted of shoulder hemiarthroplasty or reverse polarity arthroplasty in patients aged 65 years and older with acute 3- and 4-part proximal humerus fracture not amenable to osteosynthesis. The primary outcome was the Constant score at 12 months with total follow-up to 24 months. Block randomization by site was undertaken using random number generation and sealed envelopes. Power analysis indicated that 17 patients were required in each arm to achieve 80% power with an alpha-value of 5%. Secondary outcome measures were the difference in the mean Constant Score, Quick Disabilities of the Arm Shoulder and Hand Questionnaire (QuickDASH), Oxford Shoulder Score (OSS), American Shoulder and Elbow Surgeons (ASES) Score and EQ5D-5L up to two years; differences in complication rate at one and two years; differences in revision and implant failure at one and two years. RESULTS: 18 patients were randomized to hemiarthroplasty and 18 to reverse polarity arthroplasty across 4 sites. The primary outcome as measured by the Constant score at 12 months was better in the reverse polarity shoulder arthroplasty (RSA) group (Mean 51.1, s.d. 14.9) compared to the hemiarthroplasty (HA) group (mean 35.0, s.d. 13.5) (p=0.004). No significant difference was reported at 24 months but this may be due to high rates of attrition (22%). The mean EQ-5D-5L patient rated health status score was significantly higher in the RSA group compared to the HA group at 12 months. One hemiarthroplasty was revised due to implant uncoupling and one reverse polarity shoulder replacement was revised due to instability. No other complications were recorded. DISCUSSION: Treatment of unreconstructible 3- or 4-part proximal humerus fractures with reverse polarity shoulder arthroplasty results in a superior outcome compared to shoulder hemiarthroplasty at 12 months measured with the Constant score with no increased risk of failure up to 24 months in patients age 65 years and over. High attrition rates are observed in this older population due to cognitive decline and death from other causes.

2.
J Shoulder Elbow Surg ; 32(10): 2017-2026, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37263477

RESUMO

BACKGROUND: The purpose of this study is to report the clinical and radiologic outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D-printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up. METHODS: Following ethical approval, patients were identified and invited to participate. Inclusion criteria were (1) severe glenoid bone loss necessitating the need for custom implants and (2) patients with definitive glenoid and humeral components implanted more than 2 years prior. Included patients underwent clinical assessment using the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and the quick Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH). Radiographic assessment included anteroposterior and axial projections. Patients were invited to attend a computed tomography (CT) scan to confirm osseointegration. Statistical analysis used descriptive statistics (mean and standard deviation [SD]) and paired t test for parametric data. RESULTS: Eleven patients declined to participate. Five patients were deceased prior to study commencement, leaving 42 remaining patients in this analysis. Three patients had revision surgery before the 2-year follow-up; of these, 2 retained their custom glenoid components. Mean follow-up was 31.6 months from surgery (range 24-52 months). All 4 scores improved: OSS from a mean 15 (SD 8.4) to 36 (SD 12) (P < .001), Constant-Murley score from a mean 15 (SD 11.2) to 52 (SD 20.1) (P < .001), QuickDASH from a mean 70 (SD 21) to 31 (SD 24.8) (P = .004), and the ASES score from a mean 22 (SD 17.8) to 71 (SD 23.3) (P = .007). Radiologic evaluation demonstrated good osseointegration in all but 1 included patient. CONCLUSION: The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex cohort. Large complex glenoid bone defects can be managed successfully with custom 3D-printed glenoid components.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Seguimentos , Resultado do Tratamento , Impressão Tridimensional , Estudos Retrospectivos , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Amplitude de Movimento Articular
3.
Skeletal Radiol ; 50(2): 267-280, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32789679

RESUMO

Superior capsular reconstruction (SCR) is an emerging surgical technique used to treat patients with irreparable rotator cuff tears. In this procedure, a graft is attached between the superior glenoid and the greater tuberosity, with the aim of optimising glenohumeral joint function and stability. Pre-operative radiological evaluation of patients having such cuff tears is crucial for appropriate patient selection. Such imaging is particularly useful for the assessment of the cuff tear size and location, muscle wasting, fatty infiltration and the presence of any glenohumeral joint arthritis. In addition, post-operative imaging is useful in assessing graft integrity, with specific patterns of graft failure now being recognised on imaging. This article will discuss the indications and contraindications for this procedure, and review the biomechanical concepts of SCR in improving glenohumeral joint stability and restoring the force couples around the joint. The radiological appearances of the intact graft and the various patterns of graft failure will be illustrated, along with various radiological examples.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Manguito Rotador , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Escápula , Ombro/diagnóstico por imagem , Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
4.
J Shoulder Elbow Surg ; 30(3): 668-678, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32650067

RESUMO

BACKGROUND: Severe glenoid bone loss remains a challenge in patients requiring shoulder arthroplasty and often requires autogenous bone grafting. The purpose of this study was to assess the integrity of the bone graft at 2 years in a series of primary and revision shoulder replacements where glenoid bone loss was managed using a structural autograft (humeral head or iliac crest bone graft) in combination with a trabecular titanium (TT) implant. METHODS: Ethical approval was sought, and the study has a portfolio study status by the NIHR (17/YH/0318). We contacted patients who had primary and revision shoulder arthroplasty with Lima Axioma TT metal-back glenoid with autologous bone graft and were more than 2 years since their operation. All eligible patients underwent computed tomographic evaluation, clinical review, and scoring. Early failures of composite fixation and patients who had revision procedures were excluded (2 patients). RESULTS: Forty-one patients (43 shoulders) with a mean age of 65 years (range 33-85 years) were reviewed. There were 24 women and 17 men. The average follow-up period was 40 months (range 24-59 months). Primary arthroplasty was performed in 24 shoulders, whereas 19 shoulders had revision arthroplasty. Twenty-five shoulders had reverse shoulder replacement and 18 had anatomic shoulder replacement. Twenty-four shoulders had graft taken from the humeral head, and 19 had iliac crest bone graft, reflecting the number of revisions. We used Wrightington classification for porous metal implant and bone graft incorporation. Satisfactory bone graft incorporation (>50%) was seen in 40 shoulders, and only 3 patients had <50% graft incorporation. The scans at 2 years or later showed no significant deterioration in the bone graft from the early postoperative scans. Average forward elevation improved from 50° (preoperative) to 98° (range 35°-150°). The mean improvement in mean Oxford Shoulder Score was 16 (preoperative, 15; postoperative, 31) and the mean improvement in Constant score improvement was 36 (preoperative, 12; postoperative, 48). The mean postoperative American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) score was 64 (range 30-85). CONCLUSION: The use of TT in conjunction with autologous bone graft provides a reliable method of addressing glenoid bone defects in primary and revision shoulder arthroplasty. This graft-trabecular metal composite has been shown to integrate well and remain largely unchanged over a 2-year period. A stable baseplate is essential in difficult primary and revision arthroplasty situations. The stability of this construct in our series is reflected in the satisfactory outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Adulto , Idoso , Idoso de 80 Anos ou mais , Autoenxertos , Transplante Ósseo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Sobrevivência , Resultado do Tratamento
5.
Arch Sex Behav ; 46(3): 721-733, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26502283

RESUMO

"Hypersexual" behavior represents a perceived inability to control one's sexual behavior. To investigate hypersexual behavior, an international sample of 510 self-identified heterosexual, bisexual, and homosexual men and women completed an anonymous online self-report questionnaire battery. In addition to age and sex (male), hypersexual behavior was related to higher scores on measures of sexual excitation, sexual inhibition due to the threat of performance failure, trait impulsivity, and both depressed mood and anxiety. In contrast, hypersexual behavior was related to lower scores on sexual inhibition due to the threat of performance consequences. Higher neuroticism and extraversion, as well as lower agreeableness and conscientiousness, also predicted hypersexual behavior. Interestingly, interactions among the variables assessed did not significantly predict hypersexual behavior, suggesting the possible existence of multiple and predominantly independent taxa for various persons reporting hypersexual behavior. Core personality features may also be present in persons with hypersexual behavior. Clinical implications and future research directions are discussed.


Assuntos
Internet , Transtornos Parafílicos/epidemiologia , Transtornos Parafílicos/psicologia , Autorrelato , Disfunções Sexuais Psicogênicas/epidemiologia , Disfunções Sexuais Psicogênicas/psicologia , Transtornos de Ansiedade , Estudos de Coortes , Feminino , Humanos , Masculino , Neuroticismo , Inventário de Personalidade , Inquéritos e Questionários
6.
Arch Sex Behav ; 46(8): 2231-2251, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28687897

RESUMO

An empirical review of hypersexuality is timely as "compulsive sexual behavior" is being considered as an impulse control disorder for inclusion in the forthcoming International Classification of Diseases, 11th ed. Specifically, hypersexuality has been conceptualized in the literature as the inability to regulate one's sexual behavior that is a source of significant personal distress. Various theoretical models have been posited in an attempt to understand the occurrence of hypersexuality, although disagreement about these divergent conceptualizations of the condition has made assessment and treatment of hypersexual clients more challenging. Theories of sexual compulsivity, sexual impulsivity, dual control (sexual inhibition/excitation), and sex addiction are critically examined, as are the diagnostic criteria for clinically assessing hypersexuality as a sexual disorder. Our discussion of hypersexuality covers a diversity of research and clinical perspectives. We also address various challenges associated with reliably defining, psychometrically measuring, and diagnosing hypersexuality. Furthermore, literature is reviewed that expresses concerns regarding whether hypersexuality (conceptualized as a disorder) exists, whether it is simply normophilic behavior at the extreme end of sexual functioning, or alternatively is a presenting problem that requires treatment rather than a clinical diagnosis. Following our literature review, we developed the "sexhavior cycle of hypersexuality" to potentially explain the neuropsychology and maintenance cycle of hypersexuality. The sexhavior cycle suggests that, for some hypersexual persons, high sexual arousal may temporarily and adversely impact cognitive processing (cognitive abeyance) and explain a repeated pattern of psychological distress when interpreting one's sexual behavior (sexual incongruence). We also suggest that further research is required to validate whether hypersexuality is a behavioral disorder (such as gambling), although some presentations of the condition appear to be symptomatic of a heterogeneous psychological problem that requires treatment.


Assuntos
Comportamento Compulsivo , Transtornos Parafílicos , Comportamento Sexual , Feminino , Humanos , Masculino
7.
J Shoulder Elbow Surg ; 26(12): e382-e389, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28865963

RESUMO

BACKGROUND: This study compared the accuracy of measuring shoulder range of movement (ROM) with a simple laptop-sensor combination vs. trained observers (shoulder physiotherapists and shoulder surgeons) using motion capture (MoCap) laboratory equipment as the gold standard. METHODS: The Microsoft Kinect sensor (Microsoft Corp., Redmond, WA, USA) tracks 3-dimensional human motion. Ordinarily used with an Xbox (Microsoft Corp.) video game console, Medical Interactive Recovery Assistant (MIRA) software (MIRA Rehab Ltd., London, UK) allows this small sensor to measure shoulder movement with a standard computer. Shoulder movements of 49 healthy volunteers were simultaneously measured by trained observers, MoCap, and the MIRA device. Internal rotation was assessed with the shoulder abducted 90° and external rotation with the shoulder adducted. Visual estimation and MIRA measurements were compared with gold standard MoCap measurements for agreement using Bland-Altman methods. RESULTS: There were 1670 measurements analyzed. The MIRA evaluations of all 4 cardinal shoulder movements were significantly more precise, with narrower limits of agreement, than the measurements of trained observers. MIRA achieved ±11° (95% confidence interval [CI], 8.7°-12.6°) for forward flexion vs. ±16° (95% CI, 14.6°-17.6°) by trained observers. For abduction, MIRA showed ±11° (95% CI, 8.7°-12.8°) against ±15° (95% CI, 13.4°-16.2°) for trained observers. MIRA attained ±10° (95% CI, 8.1°-11.9°) during external rotation measurement, whereas trained observers only reached ±21° (95% CI, 18.7°-22.6°). For internal rotation, MIRA achieved ±9° (95% CI, 7.2°-10.4°), which was again better than TOs at ±18° (95% CI, 16.0°-19.3°). CONCLUSIONS: A laptop combined with a Microsoft Kinect sensor and the MIRA software can measure shoulder movements with acceptable levels of accuracy. This technology, which can be easily set up, may also allow precise shoulder ROM measurement outside the clinic setting.


Assuntos
Amplitude de Movimento Articular , Articulação do Ombro/fisiologia , Software , Adulto , Feminino , Humanos , Masculino , Microcomputadores , Movimento , Observação , Reprodutibilidade dos Testes , Rotação
11.
J Shoulder Elbow Surg ; 23(4): 500-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24630545

RESUMO

BACKGROUND: There is little evidence for the optimal form of nonoperative treatment in the management of frozen shoulder. This study assesses the efficacy of current physiotherapy strategies. METHODS: All primary care referrals of frozen shoulder to our physiotherapy department were included during a 12-month period. Of these referrals, 17% met the inclusion criteria for primary idiopathic frozen shoulder. The 75 patients were randomly assigned to 1 of 3 groups: group exercise class, individual physiotherapy, and home exercises alone. A single independent physiotherapist, who was blinded to the treatment groups, made all assessments. Range of motion, Constant score, Oxford Shoulder Score, Short Form 36, and Hospital Anxiety and Disability Scale (HADS) outcome measures were performed at baseline, 6 weeks, 6 months, and 1 year. RESULTS: The exercise class group improved from a mean Constant score of 39.8 at baseline to 71.4 at 6 weeks and 88.1 at 1 year. There was a significant improvement in shoulder symptoms on Oxford and Constant scores (P < .001). This improvement was greater than with individual physiotherapy or home exercises alone (P < .001). The improvement in range of motion was significantly greater in both physiotherapy groups over home exercises (P < .001). HADS scores significantly improved during the course of treatment (P < .001). The improvement in HADS anxiety score was significantly greater in both physiotherapy intervention groups than in home exercises alone. CONCLUSIONS: A hospital-based exercise class can produce a rapid recovery from a frozen shoulder with a minimum number of visits to the hospital and is more effective than individual physiotherapy or a home exercise program.


Assuntos
Bursite/terapia , Terapia por Exercício , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modalidades de Fisioterapia , Amplitude de Movimento Articular , Método Simples-Cego , Resultado do Tratamento
15.
J Affect Disord ; 331: 442-451, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-36963515

RESUMO

BACKGROUND: Caring Contacts can effectively reduce suicide ideation, attempts, and death. In published clinical trials, Caring Contacts were sent by someone who knew the recipient. At scale, Caring Contacts programs rarely introduce the recipient and sender. It is not known whether receiving Caring Contacts from someone unknown is as effective as messages from someone the recipient has met. METHODS: Pragmatic randomized controlled trial comparing Caring Contacts with (CC+) versus without an introductory phone call (CC). Recruitment occurred January-July 2021, with outcomes assessed at 6 months. Participants were primary care patients or healthcare providers/staff reporting adverse mental health outcomes on a qualifying survey. Participants were sent 11 standardized caring text messages over 6 months; when participants replied, they received personalized unscripted responses. CC+ calls were semi-structured. The primary outcome was loneliness (NIH Toolkit). RESULTS: Participants included 331 patients (mean [SD] age: 45.5 [16.4], 78.9 % female) and 335 healthcare providers/staff (mean [SD] age: 40.9 [11.8], 86.6 % female). There were no significant differences in loneliness at 6 months by treatment arm in either stratum. In patients, mean (SD) loneliness was 61.9 (10.7) in CC, and 60.8 (10.3) in CC+, adjusted mean difference of -1.0 (95 % CI: -3.0, 1.0); p-value = 0.31. In providers/staff, mean (SD) loneliness was 61.2 (11) in CC, and 61.3 (11.1) in CC+, adjusted mean difference of 0.2 (95 % CI: -1.8, 2.2); p-value = 0.83. LIMITATIONS: Study population was 93 % white which may limit generalizability. CONCLUSIONS: Including an initial phone call added operational complexity without significantly improving the effectiveness of a Caring Contacts program.


Assuntos
Transtornos Mentais , Envio de Mensagens de Texto , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Masculino , Solidão , Ideação Suicida , Pessoal de Saúde
16.
Contemp Clin Trials ; 131: 107268, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37321352

RESUMO

BACKGROUND: Suicide is a leading cause of death in adolescents and adults in the US. Follow-up support delivered when patients return home after an emergency department (ED) or primary care encounter can significantly reduce suicidal ideation and attempts. Two follow-up models to augment usual care including the Safety Planning Intervention have high efficacy: Instrumental Support Calls (ISC) and Caring Contacts (CC) two-way text messages, but they have never been compared to assess which works best. This protocol for the Suicide Prevention Among Recipients of Care (SPARC) Trial aims to determine which model is most effective for adolescents and adults with suicide risk. METHODS: The SPARC Trial is a pragmatic randomized controlled trial comparing the effectiveness of ISC versus CC. The sample includes 720 adolescents (12-17 years) and 790 adults (18+ years) who screen positive for suicide risk during an ED or primary care encounter. All participants receive usual care and are randomized 1:1 to ISC or CC. The state suicide hotline delivers both follow-up interventions. The trial is single-masked, with participants unaware of the alternative treatment, and is stratified by adolescents/adults. The primary outcome is suicidal ideation and behavior, measured using the Columbia Suicide Severity Rating Scale (C-SSRS) screener at 6 months. Secondary outcomes include C-SSRS at 12 months, and loneliness, return to crisis care for suicidality, and utilization of outpatient mental health services at 6 and 12 months. DISCUSSION: Directly comparing ISC and CC will determine which follow-up intervention is most effective for suicide prevention in adolescents and adults.


Assuntos
Suicídio , Envio de Mensagens de Texto , Adolescente , Adulto , Humanos , Serviço Hospitalar de Emergência , Atenção Primária à Saúde , Ideação Suicida , Suicídio/psicologia , Prevenção do Suicídio , Ensaios Clínicos Pragmáticos como Assunto
18.
Acta Orthop ; 83(3): 267-70, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22401678

RESUMO

BACKGROUND AND PURPOSE: In detection of glenoid labrum pathology, MR arthrography (MRA) has shown sensitivities of 88-100% and specificities of 89-93%. However, our practice suggested that there may be a higher frequency of falsely negative reports. We assessed the accuracy of this costly modality in practice. PATIENTS AND METHODS: We retrospectively reviewed MRA reports of 90 consecutive patients with clinical shoulder instability who had undergone shoulder arthroscopy. All had a history of traumatic anterior shoulder dislocation and had positive anterior apprehension tests. All underwent arthroscopy and stabilization during the same procedure. We compared the findings, using arthroscopic findings as the gold standard in the identification of glenoid labrum pathology. RESULTS: 83 of the 90 patients had glenoid labrum tears at arthroscopy. Only 54 were correctly identified at MRA. All normal glenoid labra were identified at MRA. This gave a sensitivity of 65% and a specificity of 100% in identification of all types of glenoid labrum tear. 74 patients had anterior glenoid labral tears that were detected at an even lower rate of sensitivity (58%). INTERPRETATION: The sensitivity of MRA in this series was substantially lower than previously published, suggesting that MRA may not be as reliable a diagnostic imaging modality in glenohumeral instability as previously thought. Our findings highlight the importance of an accurate history and clinical examination in the management of glenohumeral instability. The need for MRA may not be as high as is currently believed.


Assuntos
Artrografia/normas , Instabilidade Articular/diagnóstico , Imageamento por Ressonância Magnética/normas , Lesões do Ombro , Adulto , Artrografia/economia , Artrografia/métodos , Humanos , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ruptura , Sensibilidade e Especificidade , Luxação do Ombro/etiologia , Procedimentos Desnecessários/economia , Procedimentos Desnecessários/estatística & dados numéricos , Adulto Jovem
19.
Shoulder Elbow ; 14(3): 269-277, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35599713

RESUMO

Aims: Achieving purchase in native glenoid bone is essential for the stability of the glenoid baseplate when bone graft is used to address bone loss in both primary and revision shoulder arthroplasty procedures. The aim of this study is to assess the required depth of the baseplate peg in native bone when bone graft is used to result in satisfactory integration. Patients and methods: The CT scans of patients who underwent either primary or revision arthroplasty procedures with bone graft using the SMR Axioma Trabecular Titanium (TT) Metal Backed glenoid system were assessed. We measured the depth of the glenoid peg in native glenoid bone. Measurements were taken by two authors separately. Results: The scans of 53 patients (mean age 68 years) with a minimum follow-up of two years were reviewed. Implants included 12 anatomical and 41 reverse geometry prostheses. There were 17 primaries and 36 revisions: hemiarthroplasties (20) total (14) and reverse (2) implants. Bone grafts were from humeral head (15), iliac crest (34) and allograft (4). The mean depths were 8.8 mm (first assessor) and 9.10 mm (second assessor). The glenoid peg violated the glenoid vault in 32 patients and this did not adversely affect the outcome. There were three failures of implants all of which were aseptic failures and had peg penetration of less than 6 mm. Conclusions: The mean depth of glenoid peg in native bone was 9 mm (variation between 0.2 and 0.52 mm at 95% confidence interval). Aseptic loosening was seen with peg penetration less than 6 mm in native bone. Glenoid vault violation was not associated with loosening.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA