Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Mol Genet Metab ; 102(2): 216-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20965758

RESUMO

Succinic semialdehyde dehydrogenase deficiency is a slowly progressive to static neurological disorder featuring elevated concentrations of 4-hydroxybutyric acid in body fluids. We present two patients with elevated 4-hydroxybutyric acid in urine which was later shown to be linked to catheter usage.


Assuntos
Erros Inatos do Metabolismo dos Aminoácidos/diagnóstico , Catéteres , Hidroxibutiratos/urina , 4-Butirolactona/urina , Erros Inatos do Metabolismo dos Aminoácidos/enzimologia , Catéteres/normas , Deficiências do Desenvolvimento , Feminino , Humanos , Hidroxibutiratos/sangue , Lactente , Recém-Nascido , Doença da Urina de Xarope de Bordo/diagnóstico , Doença da Urina de Xarope de Bordo/enzimologia , Succinato-Semialdeído Desidrogenase/deficiência
2.
Mol Genet Metab ; 102(3): 339-42, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21195649

RESUMO

Cystinosis is an autosomal recessive lysosomal storage disease caused by mutations in CTNS. The most prevalent CTNS mutation is a homozygous 57-kb deletion that also includes an adjacent gene named SHPK (CARKL), encoding sedoheptulokinase. Patients with this deletion have elevated urinary concentrations of sedoheptulose. Using derivatisation with pentafluorobenzyl hydroxylamine and liquid chromatography-tandem mass spectrometry (LC-MS/MS), we developed a new sensitive method for the quantification of sedoheptulose in dried blood spots. This method can be utilized as a quick screening test to detect cystinosis patients homozygous for the 57-kb deletion in CTNS; which is the most common mutation of cystinosis. Sedoheptulose concentrations in the deleted patients were 6 to 23 times above the upper limit for controls. The assessment of sedoheptulose in a bloodspot from a known cystinosis patient homozygous for the 57-kb deletion retrieved from the Dutch neonatal screening program showed that sedoheptulose was already elevated in the neonatal period. There was no overlap in sedoheptulose levels between cystinosis patients homozygous for the 57-kb deletion and cystinosis patients not homozygous for this deletion. Our presented method can be used prior to mutation analysis to detect cystinosis patients homozygous for the 57-kb deletion. We feel that the presented method enables fast (pre)-symptomatic detection of cystinosis patients homozygous for the 57-kb deletion, allowing early treatment.


Assuntos
Cistinose/diagnóstico , Cistinose/enzimologia , Deleção de Genes , Heptoses/sangue , Triagem Neonatal/métodos , Sistemas de Transporte de Aminoácidos Neutros/genética , Cistinose/sangue , Cistinose/genética , Humanos , Recém-Nascido , Fosfotransferases (Aceptor do Grupo Álcool)/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem , Fatores de Transcrição/genética
3.
Neuropediatrics ; 42(2): 74-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21544765

RESUMO

CSF N-acetylaspartylglutamate (NAAG) has been found to be elevated in some hypomyelinating disorders. This study addressed the question whether it could be used as a marker for hypomyelination and as a means to distinguish between hypomyelinating disorders biochemically. We have measured CSF NAAG in a cohort of 28 patients with hypomyelination with known and unknown aetiology. NAAG was found to be elevated in 7 patients, but was normal in the majority, including patients with defined hypomyelinating disorders. CSF NAAG is not a universal marker of hypomyelination, and the mechanism of its elevation remains poorly understood.


Assuntos
Doenças Desmielinizantes/líquido cefalorraquidiano , Dipeptídeos/líquido cefalorraquidiano , Leucoencefalopatias/líquido cefalorraquidiano , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Trítio/líquido cefalorraquidiano , Adulto Jovem
4.
J Inherit Metab Dis ; 31(6): 703-17, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18987987

RESUMO

The recent discovery of two defects (ribose-5-phosphate isomerase deficiency and transaldolase deficiency) in the reversible part of the pentose phosphate pathway (PPP) has stimulated interest in this pathway. In this review we describe the functions of the PPP, its relation to other pathways of carbohydrate metabolism and an overview of the metabolic defects in the reversible part of the PPP.


Assuntos
Erros Inatos do Metabolismo/diagnóstico , Mutação , Via de Pentose Fosfato/fisiologia , Transaldolase/deficiência , Glicólise , Humanos , Hipóxia , Erros Inatos do Metabolismo/genética , Modelos Biológicos , NADP/metabolismo , Neoplasias/diagnóstico , Neoplasias/metabolismo , Oxigênio/metabolismo , Fenótipo , Ribose/metabolismo , Transaldolase/genética
5.
Acta Clin Belg ; 69(3): 221-3, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24694265

RESUMO

High anion gap metabolic acidosis due to pyroglutamic acid (5-oxoproline) is a rare complication of acetaminophen treatment (which depletes glutathione stores) and is often associated with clinically moderate to severe encephalopathy. Acquired 5-oxoprolinase deficiency (penicillins) or the presence of other risk factors of glutathione depletion such as malnutrition or sepsis seems to be necessary for symptoms development. We report the case of a 55-year-old women who developed a symptomatic overproduction of 5-oxoproline during flucloxacillin treatment for severe sepsis while receiving acetaminophen for fever control. Hemodialysis accelerated the clearance of the accumulated organic acid, and was followed by a sustained clinical improvement.


Assuntos
Acidose/induzido quimicamente , Ácido Pirrolidonocarboxílico/efeitos adversos , Acetaminofen/efeitos adversos , Acidose/diagnóstico , Acidose/terapia , Antibacterianos/efeitos adversos , Antipiréticos/efeitos adversos , Feminino , Febre/tratamento farmacológico , Febre/etiologia , Floxacilina/efeitos adversos , Humanos , Pessoa de Meia-Idade
6.
J Inherit Metab Dis ; 28(6): 951-63, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16435188

RESUMO

Several inborn errors of metabolism with abnormal polyol concentrations in body fluids are known to date. Most of these defects can be diagnosed by the assessment of urinary concentrations of polyols. We present two methods using tandem mass spectrometry for screening for inborn errors affecting polyol metabolism. Urine samples supplemented with internal standards ([13C4]erythritol, [13C2]arabitol and [2H3]sorbitol) were desalted by a mixed-bed ion-exchange resin. Separation was achieved by two different columns. Sugar isomers could not be separated using a Prevail Carbohydrate ES 54 column (method 1), whereas with the other column (Aminex HPX-87C) separation of the isomers was achieved (method 2). Multiple reaction monitoring polyol detection was achieved by tandem mass spectrometry with an electron ion-spray source operating in the negative mode. Age-related reference ranges of polyols (erythritol, treitol, arabitol, ribitol, xylitol, galactitol, mannitol, sorbitol, sedoheptitol and perseitol) in urine were established. The applicability of the method was demonstrated by the abnormal polyol concentrations observed in patients with transaldolase deficiency, ribose-5-phosphate isomerase deficiency and classical galactosaemia. This paper describes two methods for the analysis of urinary polyols by liquid chromatography-tandem mass spectrometry. Method 1 is a fast screening method with the quantification of total isomers and method 2 is a more selective method with the separate quantification of the polyols. Both methods can be used for diagnosing inborn errors of metabolism affecting polyol metabolism.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Erros Inatos do Metabolismo/urina , Álcoois Açúcares/urina , Aldose-Cetose Isomerases/urina , Calibragem , Eritritol/urina , Galactitol/urina , Humanos , Manitol/urina , Polímeros/análise , Isoformas de Proteínas , Padrões de Referência , Reprodutibilidade dos Testes , Ribitol/urina , Sorbitol/urina , Álcoois Açúcares/química , Xilitol/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA