RESUMO
BACKGROUND: Single-cell droplet microfluidics is an important platform for high-throughput analyses and screening because it provides an independent and compartmentalized microenvironment for reaction or cultivation by coencapsulating individual cells with various molecules in monodisperse microdroplets. In combination with microbial biosensors, this technology becomes a potent tool for the screening of mutant strains. In this study, we demonstrated that a genetically engineered yeast strain that can fluorescently sense agonist ligands via the heterologous expression of a human G-protein-coupled receptor (GPCR) and concurrently secrete candidate peptides is highly compatible with single-cell droplet microfluidic technology for the high-throughput screening of new agonistically active peptides. RESULTS: The water-in-oil microdroplets were generated using a flow-focusing microfluidic chip to encapsulate engineered yeast cells coexpressing a human GPCR [i.e., angiotensin II receptor type 1 (AGTR1)] and a secretory agonistic peptide [i.e., angiotensin II (Ang II)]. The single yeast cells cultured in the droplets were then observed under a microscope and analyzed using image processing incorporating machine learning techniques. The AGTR1-mediated signal transduction elicited by the self-secreted Ang II peptide was successfully detected via the expression of a fluorescent reporter in single-cell yeast droplet cultures. The system could also distinguish Ang II analog peptides with different agonistic activities. Notably, we further demonstrated that the microenvironment of the single-cell droplet culture enabled the detection of rarely existing positive (Ang II-secreting) yeast cells in the model mixed cell library, whereas the conventional batch-culture environment using a shake flask failed to do so. Thus, our approach provided compartmentalized microculture environments, which can prevent the diffusion, dilution, and cross-contamination of peptides secreted from individual single yeast cells for the easy identification of GPCR agonists. CONCLUSIONS: We established a droplet-based microfluidic platform that integrated an engineered yeast biosensor strain that concurrently expressed GPCR and self-secreted the agonistic peptides. This offers individually isolated microenvironments that allow the culture of single yeast cells secreting these peptides and gaging their signaling activities, for the high-throughput screening of agonistic peptides. Our platform base on yeast GPCR biosensors and droplet microfluidics will be widely applicable to metabolic engineering, environmental engineering, and drug discovery.
Assuntos
Microfluídica , Saccharomyces cerevisiae , Humanos , Microfluídica/métodos , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo , Peptídeos/metabolismo , Receptores Acoplados a Proteínas G/genética , Receptores Acoplados a Proteínas G/metabolismo , Ensaios de Triagem em Larga EscalaRESUMO
Cell surface properties of microorganisms provide abundant information for their physiological status and fate choice. However, current methods for analyzing cell surface properties require labeling or fixation, which can alter the cell activity. This study establishes a label-free, rapid, noninvasive, and quantitative analysis of cell surface properties, including the presence and the dimension of epistructure, down to the single-cell level and at the nanometer scale. Simultaneously, electrorotation provides dielectric properties of intracellular contents. With the combined information, the growth phase of microalgae cells can be identified. The measurement is based on electrorotation of single cells, and an electrorotation model accounting for the surface properties is developed to properly interpret experimental data. The epistructure length measured by electrorotation is validated by scanning electron microscopy. The measurement accuracy is satisfactory in particular in the case of microscale epistructures in the exponential phase and nanoscale epistructures in the stationary phase. However, the measurement accuracy for nanoscale epistructures on cells in the exponential phase is offset by the effect of a thick double layer. Lastly, a diversity in epistructure length distinguishes exponential phase from stationary phase.
Assuntos
Membrana CelularRESUMO
A key challenge for bioprocess engineering is the identification of the optimum process conditions for the production of biochemical and biopharmaceutical compounds using prokaryotic as well as eukaryotic cell factories. Shake flasks and bench-scale bioreactor systems are still the golden standard in the early stage of bioprocess development, though they are known to be expensive, time-consuming, and labor-intensive as well as lacking the throughput for efficient production optimizations. To bridge the technological gap between bioprocess optimization and upscaling, we have developed a microfluidic bioreactor array to reduce time and costs, and to increase throughput compared with traditional lab-scale culture strategies. We present a multifunctional microfluidic device containing 12 individual bioreactors (Vt = 15 µl) in a 26 mm × 76 mm area with in-line biosensing of dissolved oxygen and biomass concentration. Following initial device characterization, the bioreactor lab-on-a-chip was used in a proof-of-principle study to identify the most productive cell line for lactic acid production out of two engineered yeast strains, evaluating whether it could reduce the time needed for collecting meaningful data compared with shake flasks cultures. Results of the study showed significant difference in the strains' productivity within 3 hr of operation exhibiting a 4- to 6-fold higher lactic acid production, thus pointing at the potential of microfluidic technology as effective screening tool for fast and parallelizable industrial bioprocess development.
Assuntos
Reatores Biológicos , Ácido Láctico/metabolismo , Saccharomyces cerevisiae/metabolismo , Desenho de Equipamento , Microbiologia Industrial/instrumentação , Dispositivos Lab-On-A-Chip , Saccharomyces cerevisiae/citologiaRESUMO
Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 µg/mL and 0.05 µg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.
RESUMO
A rapid and noninvasive quantification method for cellular lipids in Chlorella vulgaris is demonstrated in this study. This method applied near-infrared Raman spectroscopy to monitor the change of signal intensities at 1440 cm(-1) and 2845-3107 cm(-1) along the nitrogen depletion period, and calibration curves relating signal intensity and cellular lipid abundance were established. The calibration curves show that signal intensity at 2845-3107 cm(-1) and cellular lipid abundance were highly correlated. When the calibration curve was applied on the lipid quantification of two unknown samples, the differences between lipid abundances estimated by the calibration curve and measured by gas chromatography were less than 2 wt %. Carotenoids produced a strong and broad peak near 1440 cm(-1), and it weakened the correlation between signal intensity and lipid abundance. The consistency of detection and effects of cellular contents and water on the Raman spectrogram of Chlorella vulgaris were also addressed. The sample pretreatment only involved centrifugation, and the time required for lipid quantification was shortened to less than 1.5 h. The rapid detection has great potential in high-throughput screening of microalgae and also provides valuable information for monitoring the quality of microalgae culture and determining parameters for the mass production of biodiesel from microalgae.
Assuntos
Chlorella vulgaris/metabolismo , Lipídeos/análise , Espectroscopia de Luz Próxima ao Infravermelho , Celulose/análise , Azeite de Oliva , Pectinas/análise , Óleos de Plantas/análise , beta Caroteno/análiseRESUMO
The load on drive elements under extreme pressure conditions is significantly larger than that used in machine tools. When operating under a heavy load for a long period, large deformation and severe wear between the ball and the track are more likely to occur. To reduce wear, the most fundamental solution is to improve the surface properties of the material. Moreover, heat treatment is the most effective method to improve the surface properties of materials, thereby achieving wear resistance and low friction. It is necessary to develop a new heat treatment technology for wear resistance in extreme pressure conditions. Therefore, this study conducted experiments using a reciprocating friction tester. The responses of electrical contact resistance and the friction coefficient were measured synchronously to investigate wear resistance and low friction of the alloy steels after the induction heat treatment. Then, the results were compared and verified with low-carbon alloy steel after the traditional carburizing heat treatment. The experimental results show that the application of new induction heat treatment technology can not only improve the performance of drive components, but also save time and energy, and streamline the production process of the drive components. Therefore, the results of these wear analyses confirm that the induction heat treatment mode can replace the traditional carburizing heat treatment mode for drive elements.
RESUMO
To elucidate the Tau gain-of-toxicity functional mechanism and to search for potential treatments, we overexpressed human Tau variants (hTau) in the dorsal mesothorax (notum) of Drosophila. Overexpression of Tau variants caused loss of notal bristles, and the phenotype was used for evaluating toxicity of ectopic Tau. The bristle loss phenotype was found to be highly associated with the toxicity of hyperphosphoryled Tau in flies. We have shown that the bristle loss phenotype can be rescued either by reducing Glycogen synthase kinase 3beta (GSK3beta)/Shaggy (Sgg) activity or overexpressing Bbeta2 regulatory subunits of PP2A. Elevated expression of the Drosophila Bbeta2 homolog, Twins (Tws), also alleviated neuritic dystrophy of the dorsal arborization (da) neuron caused by Tau aggregation. Additionally, lowering endogenous Tau dosage was beneficial as it ameliorated the bristle loss phenotype. Finally, the bristle loss phenotype was used to evaluate the efficacy of potential therapeutic compounds. The GSK3beta inhibitor, alsterpaullone, was found to suppress toxicity of Tau in a concentration-dependent manner. The notum of Drosophila, thus, provides a new tool and insights into Tau-induced toxicity. It could also potentially assist in screening new drugs for possible therapeutic intervention.
Assuntos
Animais Geneticamente Modificados , Drosophila melanogaster/genética , Quinase 3 da Glicogênio Sintase/antagonistas & inibidores , Inibidores de Proteínas Quinases/isolamento & purificação , Tauopatias/metabolismo , Proteínas tau/metabolismo , Animais , Benzazepinas/farmacologia , Modelos Animais de Doenças , Proteínas de Drosophila/metabolismo , Drosophila melanogaster/efeitos dos fármacos , Avaliação Pré-Clínica de Medicamentos , Quinase 3 da Glicogênio Sintase/metabolismo , Humanos , Indóis/farmacologia , Emaranhados Neurofibrilares/metabolismo , Fosfoproteínas Fosfatases/metabolismo , Fosforilação , Inibidores de Proteínas Quinases/farmacologia , Proteínas tau/genéticaRESUMO
This study aims to investigate the efficacy of lipid induction in Scenedesmus abundans by adding the effluent from dark fermentation of biohydrogen production. Four sets of experiments were conducted: control (sufficient nitrogen), nitrogen depletion, low concentration (0.3×) effluent addition, and high concentration (0.5×) effluent addition. The addition of low concentration effluent produced the highest biomass and lipid yields of 2.831 g/L and 1.238 g/L, corresponding to a lipid abundance of 43.72 wt%. Furthermore, S. abundans had high removal efficiencies for volatile fatty acids in the effluent (formic acid 100%, acetic acid 100%, propionic acid 98%, lactic acid 84%, and butyric acid 68%), and this is the first study demonstrating the ability of S. abundans in using formic acid and lactic acid to produce biomass and lipids. These results show that S. abundans have great abilities in simultaneous reducing organic acids in the effluent and producing valuable metabolites.
Assuntos
Biocombustíveis , Ácidos Graxos Voláteis/metabolismo , Hidrogênio/metabolismo , Metabolismo dos Lipídeos , Scenedesmus/crescimento & desenvolvimento , AnaerobioseRESUMO
Photosynthetic microalgae not only perform fixation of carbon dioxide but also produce valuable byproducts such as lipids and pigments. However, due to the lack of effective tools for rapid and noninvasive analysis of microalgal cellular contents, the efficiency of strain screening and culture optimizing is usually quite low. This study applied single-cell electrorotation on Scenedesmus abundans to assess cellular dielectric properties during lipid accumulation and to promptly quantify total cellular contents. The experimental electrorotation spectra were fitted with the double-shell ellipsoidal model, which considered varying cell wall thickness, to obtain the dielectric properties of cellular compartments. When the amount of total lipids increased from 15.3 wt% to 33.8 wt%, the conductivity and relative permittivity of the inner core (composed of the cytoplasm, lipid droplets, and nucleus) decreased by 21.7% and 22.5%, respectively. These dielectric properties were further used to estimate the total cellular lipid contents by the general mixing formula, and the estimated values agreed with those obtained by weighing dry biomass and extracted lipids with an error as low as 0.22 wt%. Additionally, the conductivity and relative permittivity of cell wall increased during nitrogen-starvation conditions, indicating the thickening of cell wall, which was validated by the transmission electron microscopy.
RESUMO
Detection and accurate quantitation of biomarkers such as alpha-fetoprotein (AFP) can be a key aspect of early stage cancer diagnosis. Microfluidic devices provide attractive analysis capabilities, including low sample and reagent consumption, as well as short assay times. However, to date microfluidic analyzers have relied almost exclusively on calibration curves for sample quantitation, which can be problematic for complex mixtures such as human serum. We have fabricated integrated polymer microfluidic systems that can quantitatively determine fluorescently labeled AFP in human serum using either the method of standard addition or a calibration curve. Our microdevices couple an immunoaffinity purification step with rapid microchip electrophoresis separation in a laser-induced fluorescence detection system, all under automated voltage control in a miniaturized polymer microchip. In conjunction with laser-induced fluorescence detection, these systems can quantify AFP at approximately 1 ng/mL levels in approximately 10 microL of human serum in a few tens of minutes. Our polymer microdevices have been applied in determining AFP in spiked serum samples. These integrated microsystems offer excellent potential for rapid, simple, and accurate biomarker quantitation in a point-of-care setting.
Assuntos
Corantes Fluorescentes/química , Técnicas Analíticas Microfluídicas/instrumentação , alfa-Fetoproteínas/análise , Calibragem , Cromatografia de Afinidade , Detecção Precoce de Câncer , Eletroforese em Microchip , Humanos , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/normas , Polímeros/química , Fatores de TempoRESUMO
Microchip CE of proteins labeled either off- or on-chip with the "chameleon" CE dye 503 using poly(methyl methacrylate) microchips is presented. A simple dynamic coating using the cationic surfactant CTAB prevented nonspecific adsorption of protein and dye to the channel walls. The labeling reactions for both off- and on-chip labeling proceeded at room temperature without requiring heating steps. In off-chip labeling, a 9 ng/mL concentration detection limit for BSA, corresponding to a approximately 7 fg (100 zmol) mass detection limit, was obtained. In on-chip tagging, the free dye and protein were placed in different reservoirs of the microchip, and an extra incubation step was not needed. A 1 microg/mL concentration detection limit for BSA, corresponding to a approximately 700 fg (10 amol) mass detection limit, was obtained from this protocol. The earlier elution time of the BSA peak in on-chip labeling resulted from fewer total labels on each protein molecule. Our on-chip labeling method is an important part of automation in miniaturized devices.
Assuntos
Corantes/química , Eletroforese Capilar/métodos , Dispositivos Lab-On-A-Chip , Polímeros/química , Adsorção , Limite de Detecção , Microscopia de Fluorescência , Miniaturização , Soroalbumina Bovina/análiseRESUMO
This review presents a critical assessment of emerging microfluidic technologies for the application on biological productions of biofuels and other chemicals from microalgae. Comparisons of cell culture designs for the screening of microalgae strains and growth conditions are provided with three categories: mechanical traps, droplets, or microchambers. Emerging technologies for the in situ characterization of microalgae features and metabolites are also presented and evaluated. Biomass and secondary metabolite productivities obtained at microscale are compared with the values obtained at bulk scale to assess the feasibility of optimizing large-scale operations using microfluidic platforms. The recent studies in microsystems for microalgae pretreatment, fractionation and extraction of metabolites are also reviewed. Finally, comments toward future developments (high-pressure/-temperature process; solvent-resistant devices; omics analysis, including genome/epigenome, proteome, and metabolome; biofilm reactors) of microfluidic techniques for microalgae applications are provided.
RESUMO
Electroporation is an efficient method of introducing foreign impermeant molecules such as drugs and genes into cells. Conventional electroporation has been based on the application of short electrical pulses (electropulsation). Electropulsation requires specialized equipment and cannot be integrated easily with techniques such as electrophoresis which is based on constant voltage. Here we demonstrate the delivery of small molecules and genes into cells, using a microfluidic electroporation technique based on constant direct current (DC) voltage that we developed earlier. We demonstrate the delivery of two molecules into Chinese hamster ovary (CHO-K1) cells: a membrane impermeable nucleic acid dye (SYTOX Green) and a plasmid vector carrying the gene for green fluorescent protein (pEGFP-C1). Our devices can exert field variations to flowing cells that are analogous to the application of single or multiple pulses by having different geometries. We investigate the effects of the electrical parameters and different geometries of the device on the transfection efficiency and cell viability. Our technique provides a simple solution to electroporation-based drug and gene delivery by eliminating the need for a pulse generator. We envision that these simple microscale electroporation devices will have the potential to work in parallel on a microchip platform and such technology will allow high-throughput functional screening of drugs and genes.
Assuntos
Sistemas de Liberação de Medicamentos/métodos , Eletroporação/métodos , Microfluídica/métodos , Transfecção/métodos , Animais , Células CHO , Cricetinae , Cricetulus , Eletricidade , Vetores Genéticos/genética , Proteínas de Fluorescência Verde/genética , Compostos Orgânicos/metabolismo , Plasmídeos/genéticaRESUMO
Microfluidics-based cell assays offer high levels of automation and integration, and allow multiple assays to be run in parallel, based on reduced sample volumes. These characteristics make them attractive for studies associated with drug discovery. Controlled delivery of drug molecules or other exogenous materials into cells is a critical issue that needs to be addressed before microfluidics can serve as a viable platform for drug screening and studies. In this study, we report the application of hydrodynamic focusing for controlled delivery of small molecules into cells immobilized on the substrate of a microfluidic device. We delivered calcein AM which was permeant to the cell membrane into cells, and monitored its enzymatic conversion into fluorescent calcein during and after the delivery. Different ratios of the sample flow to the side flow were tested to determine how the conditions of hydrodynamic focusing affected the delivery. A 3D numerical model was developed to help understand the fluid flow, molecular diffusion due to hydrodynamic focusing in the microfluidic channel. The results from the simulation indicated that the calcein AM concentration on the outer surface of a cell was determined by the conditions of hydrodynamic focusing. By comparing the results from the simulation with those from the experiment, we found that the calcein AM concentration on the cell outer surface correlated very well with the amount of the molecules delivered into the cell. This suggests that hydrodynamic focusing provides an effective way for potentially quantitative delivery of exogenous molecules into cells at the single cell or subcellular level. We expect that our technique will pave the way to high-throughput drug screening and delivery on a microfluidic platform.
Assuntos
Membrana Celular/química , Sistemas de Liberação de Medicamentos/métodos , Fluoresceínas/administração & dosagem , Fluoresceínas/química , Microfluídica/instrumentação , Microinjeções/instrumentação , Modelos Biológicos , Animais , Células CHO , Células Imobilizadas , Simulação por Computador , Cricetinae , Cricetulus , Microfluídica/métodos , Microinjeções/métodos , PressãoRESUMO
Electrical lysis of biological cells on a microfluidic platform has evoked significant interest because of its applications in rapid recovery of intracellular contents such as nucleic acids or proteins without introducing lytic agents. Applying a direct current (DC) field for cell lysis typically requires field strength of 1-10 kV/cm, which is dependent on the cell type: prokaryotes or eukaryotes. Bubble generation and Joule heating can often be induced under such high field strengths. In this study we fabricated a simple microfluidic device using low-cost soft lithography with channel widths considerably larger than the cell size to avoid clogging and ensure stable performance, which was able to lyse green fluorescent protein (GFP)-expressing Escherichia coli cells under continuous DC voltage while cells were flowing through the channels. The cell lysis only happened in a defined section of a microfluidic channel because of local field amplification by geometric modification. The geometric modification also effectively decreased the required voltage for lysis severalfold. The cell lysis was verified by plate count on nutrient agar plates and by fluorescence spectroscopy.
Assuntos
Bactérias/citologia , Bacteriólise , Técnicas Analíticas Microfluídicas/métodos , Escherichia coli/citologia , Técnicas Analíticas Microfluídicas/instrumentação , Microscopia de FluorescênciaRESUMO
Interest in electrical lysis of biological cells on a microfludic platform has increased because it allows for the rapid recovery of intracellular contents without introducing lytic agents. In this study we demonstrated a simple microfluidic flow-through device which lysed Escherichia coli cells under a continuous dc voltage. The E. coli cells had previously been modified to express green fluorescent protein (GFP). In our design, the cell lysis only happened in a defined section of a microfluidic channel due to the local field amplification by geometric modification. The geometric modification also effectively decreased the required voltage for lysis by several folds. We found that local field strength of 1000-1500 V/cm was required for nearly 100% cell death. This threshold field strength was considerably lower than the value reported in the literature, possibly due to the longer duration of the field [Lee, S.W., Tai, Y.C., 1999. Sens. Actuators A: Phys. 73, 74-79]. Cell lysis was detected by both plate count and fluorescence spectroscopy. The cell membrane was completely disintegrated in the lysis section of the microfluidic device, when the field strength was higher than 2000 V/cm. The devices were fabricated using low-cost soft lithography with channel widths considerably larger than the cell size to avoid clogging and ensure stable performance. Our tool will be ideal for high throughput processing of bacterial cells for chemical analysis of intracellular contents such as DNA and proteins. The application of continuous dc voltage greatly simplified the instrumentation compared to devices using electrical pulses for similar purposes. In principle, the same approach can also be applied for lysis of mammalian cells and electroporative transfection.
Assuntos
Técnicas de Cultura de Células/instrumentação , Extratos Celulares/isolamento & purificação , Fracionamento Celular/instrumentação , Eletroporação/instrumentação , Escherichia coli/fisiologia , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Cultura de Células/métodos , Fracionamento Celular/métodos , Campos Eletromagnéticos , Eletroporação/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Escherichia coli/citologia , Escherichia coli/efeitos da radiação , Técnicas Analíticas Microfluídicas/métodosRESUMO
A simple microfluidic device was demonstrated to analyze intracellular contents from single cells with high throughput based on having different field strengths in geometrically defined sections of a microchannel for electrical lysis and electrophoresis.
Assuntos
Fracionamento Celular/métodos , Citofotometria/métodos , Campos Eletromagnéticos , Eletroforese/métodos , Técnicas Analíticas Microfluídicas/métodos , Nanotecnologia/métodos , Fracionamento Celular/instrumentação , Citofotometria/instrumentação , Eletroforese/instrumentação , Desenho de Equipamento , Técnicas Analíticas Microfluídicas/instrumentação , Nanotecnologia/instrumentação , Fatores de TempoRESUMO
A membraneless microfluidic microbial fuel cell (µMFC) for rapid detection of microorganism electroactivity is demonstrated in this study. Owing to the merit of laminar flow, the proposed µMFC has well-separated anode and cathode without applying proton exchange membrane. The highest open circuit voltages (OCVs) produced by different anodal solutions: fresh medium, inactivated and untreated microflora, were 102, 131, and 246 mV, respectively. These results show that the membraneless µMFC is capable of identifying the electric potential resulting from the imbalanced compositions between two streams (29 mV) and from the electrochemical activity of microflora (115 mV). When samples obtained along a batch cycle of H-type MFC were tested, the membraneless µMFC produced similar OCVs with those from the H-type MFC. In conclusion, the proposed µMFC has comparable abilities in detecting electroactivity with the conventional H-type MFC; moreover, it can distinguish the source of collected electricity.
Assuntos
Fontes de Energia Bioelétrica/microbiologia , Fenômenos Eletrofisiológicos/fisiologia , Técnicas Analíticas Microfluídicas/métodos , Eletrodos , Taiwan , Fatores de TempoRESUMO
Microalgae have emerged as one of the most promising feedstocks for biofuels and bio-based chemical production. However, due to the lack of effective tools enabling rapid and high-throughput analysis of the content of microalgae biomass, the efficiency of screening and identification of microalgae with desired functional components from the natural environment is usually quite low. Moreover, the real-time monitoring of the production of target components from microalgae is also difficult. Recently, research efforts focusing on overcoming this limitation have started. In this review, the recent development of high-throughput methods for analyzing microalgae cellular contents is summarized. The future prospects and impacts of these detection methods in microalgae-related processing and industries are also addressed.
Assuntos
Biocombustíveis/análise , Ensaios de Triagem em Larga Escala/métodos , Microalgas/metabolismo , Biomassa , Biotecnologia/métodos , Carboidratos/análise , Ensaios de Triagem em Larga Escala/instrumentação , Lipídeos/análise , Proteínas/análiseRESUMO
Chlorella vulgaris ESP-31 containing 22.7% lipid was harvested by coagulation (using chitosan and polyaluminium chloride (PACl) as the coagulants) and centrifugation. The harvested ESP-31 was directly employed as the oil source for biodiesel production via transesterification catalyzed by immobilized Burkholderia lipase and by a synthesized solid catalyst (SrO/SiO2). Both enzymatic and chemical transesterification were significantly inhibited in the presence of PACl, while the immobilized lipase worked well with wet chitosan-coagulated ESP-31, giving a high biodiesel conversion of 97.6% w/w oil, which is at a level comparable to that of biodiesel conversion from centrifugation-harvested microalgae (97.1% w/w oil). The immobilized lipase can be repeatedly used for three cycles without significant loss of its activity. The solid catalyst SrO/SiO2 worked well with water-removed centrifuged ESP-31 with a biodiesel conversion of 80% w/w oil, but the conversion became lower (55.7-61.4% w/w oil) when using water-removed chitosan-coagulated ESP-31 as the oil source.