Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biomed Eng Lett ; 12(2): 197-203, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35529342

RESUMO

Field effect transistor (FET) biosensor is based on metal oxide field effect transistor that is gated by changes in the surface charges induced the reaction of biomolecules. In most cases of FET biosensor, FET biosensor is not being reused after the reaction; therefore, it is an important concept of investigate the biosensor with simplicity, cheap and reusability. However, the conventional cardiac troponin I (cTnI) sensing technique is inadequate owing to its low sensitivity and high operational time and cost. In this study, we developed a rapid and low-cost, and disposable electrical sensor using an extended gate field-effect transistor (EGFET) to detect cTnI, as a key biomarker for myocardiac infarction. We first investigated pH sensing characteristics according to the pH level, which provided a logarithmically linear sensitivity in the pH sensing buffer solution of approximately 57.9 mV/pH. Subsequently, we prepared a cTnI sample and monitored the reaction between cTnI and cTnI antibodies through the changes in the drain current and transfer curves. Our results showed that the EGFET biosensor could successfully detect the cTnI levels as well as the pH with low-cost and rapid detection.

2.
J Vis Exp ; (158)2020 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-32420990

RESUMO

Microvesicles and exosomes are small membranous vesicles released to the extracellular environment and circulated throughout the body. Because they contain various parental cell-derived biomolecules such as DNA, mRNA, miRNA, proteins, and lipids, their enrichment and isolation are critical steps for their exploitation as potential biomarkers for clinical applications. However, conventional isolation methods (e.g., ultracentrifugation) cause significant loss and damage to microvesicles and exosomes. These methods also require multiple repetitive steps  of ultracentrifugation, loading, and wasting of reagents. This article describes a detailed method to fabricate an origami-paper-based device (Exo-PAD) designed for the effective enrichment and isolation of microvesicles and exosomes in a simple manner. The unique design of the Exo-PAD, consisting of accordion-like multifolded layers with convergent sample areas, is integrated with the ion concentration polarization technique, thereby enabling fivefold enrichment of the microvesicles and exosomes on specific layers. In addition, the enriched microvesicles and exosomes are isolated by simply unfolding the Exo-PAD.


Assuntos
Micropartículas Derivadas de Células , Técnicas Citológicas , Exossomos , Micropartículas Derivadas de Células/ultraestrutura , Exossomos/ultraestrutura , Papel
3.
Biosens Bioelectron ; 20(10): 1932-8, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15741060

RESUMO

We report an electro-mechanical biosensor for electrical detection of proteins with disease markers using self-sensing piezoresistive micro-cantilevers. Electrical detection, via surface stress changes, of antigen-antibody (Ag-Ab) specific binding was accomplished through a direct nano-mechanical response of micro-fabricated self-sensing micro-cantilevers. A piezoresistive sensor measures the film resistance variation with respect to surface stress caused by biomolecules specific binding. When specific binding occurred on a functionalized Au surface, surface stress was induced throughout the cantilever, resulting in cantilever bending and resistance change of the piezoresistive layer. The cantilever biosensors were used for the detection of prostate specific antigen (PSA) and C-reactive proteins (CRP), which are a specific marker of prostate cancer and cardiac disease. From the above experiment, it was revealed that the sensor output voltage was proportional to the injected antigen concentration (without antigen, 10 ng/ml, 100 ng/ml, 1 microg/ml). PSA and CRP antibodies were found to be very specific for their antigens, respectively. This indicated that the self-sensing micro-cantilever approach is beneficial for detecting disease markers, and our piezoresistive micro-cantilever sensor system is applicable to miniaturized biosensor systems.


Assuntos
Técnicas Biossensoriais/instrumentação , Proteína C-Reativa/análise , Eletroquímica/instrumentação , Cardiopatias/sangue , Imunoensaio/instrumentação , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Biomarcadores/sangue , Biomarcadores Tumorais/sangue , Técnicas Biossensoriais/métodos , Proteínas Sanguíneas/análise , Impedância Elétrica , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Cardiopatias/diagnóstico , Humanos , Imunoensaio/métodos , Masculino , Miniaturização , Neoplasias da Próstata/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA