Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
J Bone Miner Metab ; 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39287797

RESUMO

INTRODUCTION: Monitoring of bone mineral density (BMD) is used to assess pharmacological osteoporosis therapy. This study examined the real-life effects of antiresorptive and osteoanabolic treatments on volumetric BMD (vBMD) of the spine by quantitative computed tomography (QCT). MATERIALS AND METHODS: Patients aged ≥ 50 years with a vBMD < 120 mg/ml had ≥ 2 QCT. For analysis of therapy effects, the pharmacological treatment and the duration of each therapy were considered. Identical vertebrae were evaluated in all vBMD measurements for each patient. A linear mixed model with random intercepts was used to estimate the effects of pharmacological treatments on vBMD. RESULTS: A total of 1145 vBMD measurements from 402 patients were analyzed. Considering potential confounders such as sex, age, and prior treatment, a reduction in trabecular vBMD was estimated for oral bisphosphonates (- 1.01 mg/ml per year; p < 0.001), intravenous bisphosphonates (- 0.93 mg/ml per year; p = 0.015) and drug holiday (- 1.58 mg/ml per year; p < 0.001). Teriparatide was estimated to increase trabecular vBMD by 4.27 mg/ml per year (p = 0.018). Patients receiving denosumab showed a statistically non-significant decrease in trabecular vBMD (- 0.44 mg/ml per year; p = 0.099). Compared to non-treated patients, pharmacological therapy had positive effects on trabecular vBMD (1.35 mg/ml; p = 0.001, 1.43 mg/ml; p = 0.004, 1.91 mg/ml; p < 0.001, and 6.63 mg/ml; p < 0.001 per year for oral bisphosphonates, intravenous bisphosphonates, denosumab, and teriparatide, respectively). CONCLUSION: An increase in trabecular vBMD by QCT was not detected with antiresorptive agents. Patients treated with teriparatide showed increasing trabecular vBMD. Non-treatment led to a larger decrease in trabecular vBMD than pharmacological therapy.

2.
Skeletal Radiol ; 53(8): 1517-1528, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38378861

RESUMO

OBJECTIVE: Distances and angles measured from long-leg radiographs (LLR) are important for surgical decision-making. However, projectional radiography suffers from distortion, potentially generating differences between measurement and true anatomical dimension. These phenomena are not uniform between conventional radiography (CR) digital radiography (DR) and fan-beam technology (EOS). We aimed to identify differences between these modalities in an experimental setup. MATERIALS AND METHODS: A hemiskeleton was stabilized using an external fixator in neutral, valgus and varus knee alignment. Ten images were acquired for each alignment and each modality: one CR setup, two different DR systems, and an EOS. A total of 1680 measurements were acquired and analyzed. RESULTS: We observed great differences for dimensions and angles between the 4 modalities. Femoral head diameter measurements varied in the range of > 5 mm depending on the modality, with EOS being the closest to the true anatomical dimension. With functional leg length, a difference of 8.7% was observed between CR and EOS and with the EOS system being precise in the vertical dimension on physical-technical grounds, this demonstrates significant projectional magnification with CR-LLR. The horizontal distance between the medial malleoli varied by 20 mm between CR and DR, equating to 21% of the mean. CONCLUSIONS: Projectional distortion resulting in variations approaching 21% of the mean indicate, that our confidence on measurements from standing LLR may not be justified. It appears likely that among the tested equipment, EOS-generated images are closest to the true anatomical situation most of the time.


Assuntos
Intensificação de Imagem Radiográfica , Humanos , Intensificação de Imagem Radiográfica/métodos , Posição Ortostática , Perna (Membro)/diagnóstico por imagem , Posicionamento do Paciente/métodos
3.
Arch Orthop Trauma Surg ; 144(1): 179-188, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37796283

RESUMO

INTRODUCTION: Dual-energy X-ray absorptiometry (DXA) is considered the gold standard for the diagnosis of osteoporosis and assessment of fracture risk despite proven limitations. Quantitative computed tomography (QCT) is regarded as a sensitive method for diagnosis and follow-up. Pathologic fractures are classified as the main clinical manifestation of osteoporosis. The objective of the study was to compare DXA and QCT to determine their sensitivity and discriminatory power. MATERIALS AND METHODS: Patients aged 50 years and older were included who had DXA of the lumbar spine and femur and additional QCT of the lumbar spine within 365 days. Fractures and bone mineral density (BMD) were retrospectively examined. BMD measurements were analyzed for the detection of osteoporotic fractures. Sensitivity and receiver operating characteristic curve were used for calculations. As an indication for a second radiological examination was given, the results were compared with control groups receiving exclusively DXA or QCT for diagnosis or follow-up. RESULTS: Overall, BMD measurements of 404 subjects were analyzed. DXA detected 15 (13.2%) patients having pathologic fractures (n = 114) with normal bone density, 66 (57.9%) with osteopenia, and 33 (28.9%) with osteoporosis. QCT categorized no patients having pathologic fractures with healthy bone density, 14 (12.3%) with osteopenia, and 100 (87.7%) with osteoporosis. T-score DXA, trabecular BMD QCT, and cortical BMD QCT correlated weakly. Trabecular BMD QCT and cortical BMD QCT classified osteoporosis with decreased bone mineral density (AUC 0.680; 95% CI 0.618-0.743 and AUC 0.617; 95% CI 0.553-0.682, respectively). T-score DXA could not predict prevalent pathologic fractures. In control groups, each consisting of 50 patients, DXA and QCT were significant classifiers to predict prevalent pathologic fractures. CONCLUSION: Our results support that volumetric measurements by QCT in preselected subjects represent a more sensitive method for the diagnosis of osteoporosis and prediction of fractures compared to DXA.


Assuntos
Fraturas Espontâneas , Osteoporose , Fraturas por Osteoporose , Idoso , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Densidade Óssea , Absorciometria de Fóton/métodos , Fraturas por Osteoporose/diagnóstico por imagem , Estudos Retrospectivos , Pós-Menopausa , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Vértebras Lombares/diagnóstico por imagem
4.
BMC Musculoskelet Disord ; 22(1): 934, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34749688

RESUMO

BACKGROUND: High primary stability is the key prerequisite for safe osseointegration of cementless intervertebral disc prostheses. The aim of our study was to determine the primary stability of intervertebral disc prostheses with two different anchoring concepts - keel and spike anchoring. METHODS: Ten ActivL intervertebral disc prostheses (5 x keel anchoring, 5 x spike anchoring) implanted in human cadaver lumbar spine specimens were tested in a spine movement simulator. Axial load flexion, extension, left and right bending and axial rotation motions were applied on the lumbar spine specimens through a defined three-dimensional movement program following ISO 2631 and ISO/CD 18192-1.3 standards. Tri-dimensional micromotions of the implants were measured for both anchor types and compared using Student's T-test for significance after calculating 95 % confidence intervals. RESULTS: In the transverse axis, the keel anchoring concept showed statistically significant (p < 0.05) lower mean values of micromotions compared to the spike anchoring concept. The highest micromotion values for both types were observed in the longitudinal axis. In no case the threshold of 200 micrometers was exceeded. CONCLUSIONS: Both fixation systems fulfill the required criteria of primary stability. Independent of the selected anchorage type an immediate postoperative active mobilization doesn't compromise the stability of the prostheses.


Assuntos
Disco Intervertebral , Fenômenos Biomecânicos , Cadáver , Humanos , Vértebras Lombares/cirurgia , Próteses e Implantes , Amplitude de Movimento Articular
5.
Schmerz ; 33(6): 549-554, 2019 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-31286239

RESUMO

This article presents the case of a 46-year-old woman with fibromyalgia with an undetected fracture of the coccyx. The heterogeneity of the symptoms of patients suffering from fibromyalgia including chronic widespread pain, vegetative and functional disorders, mental and physical exhaustion as well as sleep disorders can cause accidentally undetected comorbidities, especially if these are rare and predominantly present with pain as the main symptom. In the present case the reason for symptoms was detected only after 14 months of ineffective therapies and diagnostic procedures. The coccygeal pain was eliminated through a coccygectomy as ultima ratio. It should be nevertheless emphasized that patients with fibromyalgia suffer from a central pain-processing disorder. Indications for operative treatment must be very carefully considered. Surgery should only be considered in consultation with the patient and after failed conservative therapy.


Assuntos
Cóccix/lesões , Fibromialgia , Dor Lombar , Fraturas da Coluna Vertebral , Cóccix/cirurgia , Diagnóstico Diferencial , Feminino , Fibromialgia/fisiopatologia , Humanos , Dor Lombar/etiologia , Dor Lombar/cirurgia , Pessoa de Meia-Idade , Dor Musculoesquelética , Fraturas da Coluna Vertebral/diagnóstico
6.
Eur Spine J ; 27(8): 1671-1678, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29167992

RESUMO

BACKGROUND: We describe a case of severe and progressive lumbar hyperlordosis (160°) in a 28-year-old female university student with cerebral palsy. Her main complaints were abdominal wall pain and increasing inability to sit in her custom wheelchair. METHOD: When deciding on our opinion about the most promising treatment strategy, we contemplated slow continued correction by means of percutaneously expandable magnetic rods (MAGEC) after the index surgery as a key component of a satisfactory correction in this severe and rigid curve. After an initial radical release and partial correction, a release and correction procedure was required for the bilateral hip flexion contracture. A final in situ posterior fusion was performed as a second spinal procedure, once the desired final correction at 66° of lumbar lordosis was achieved. RESULT: Three years after the completion of surgery, the patient has a stable clinical and radiological result as well as a solid posterior fusion on CT. CONCLUSION: This is the first case published in which percutaneous magnetic distraction was successfully used in an adult patient.


Assuntos
Lordose/terapia , Magnetoterapia/métodos , Espasticidade Muscular/terapia , Fusão Vertebral/métodos , Adulto , Paralisia Cerebral/complicações , Paralisia Cerebral/cirurgia , Feminino , Contratura de Quadril/etiologia , Contratura de Quadril/cirurgia , Humanos , Lordose/etiologia , Imageamento por Ressonância Magnética , Espasticidade Muscular/etiologia , Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Eur Spine J ; 26(12): 3209-3215, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-27942939

RESUMO

PURPOSE: Vertebral augmentation is an established treatment for patients with pathological vertebral compression fractures. These procedures typically employ a PMMA-based bone cement, which possesses a high compressive stiffness. Because of the increased risk of subsequent fractures after vertebral augmentations, there is a desire for reducing this stiffness. The goal of our study was to examine the influence of adding isotonic saline on the biomechanical properties of PMMA vertebroplasty cement. METHODS: A PMMA-based vertebroplasty cement was prepared according to the manufacturer's recommendations after which isotonic saline was mixed into the cement at 10, 20, and 30% (volume:volume). Testing bodies were cast, and compression and bending tests were performed. Fracture surfaces were studied using SEM. Measurements of injectability, setting temperature, and radioopacity were also performed. RESULTS: The addition of saline solution (of up to vol-30%) led to a pronounced reduction in the compression modulus of the cement from 3409 ± 312 to 1131 ± 127 MPa. In parallel, maximal compression strength was reduced from 86 ± 4 to 33 ± 3 MPa and bending strength from 40 ± 4 to 24 ± 3 MPa. The differences regarding injectability, setting temperature, and radioopacity were small and probably of no clinical relevance. CONCLUSIONS: The compressive stiffness of PMMA-based vertebroplasty cement can be reduced to almost a third by the addition of saline. The probable explanation is an increase in microporosity. Future simulator experiments will show whether the achieved reduction in stiffness is large enough to reduce the rate of subsequent vertebral fractures.


Assuntos
Cimentos Ósseos/química , Polimetil Metacrilato/química , Cloreto de Sódio/química , Vertebroplastia/instrumentação , Força Compressiva , Teste de Materiais , Modelos Biológicos
8.
Clin Anat ; 30(2): 267-275, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27889923

RESUMO

Evaluation of hip joint space width during child growth is important to aid in the early diagnosis of hip pathology in children. We established reference values for hip joint space and femoral head size for each age. Hip joint space development during growth was retrospectively investigated medial and cranial in 1350 hip joints of children using standard anteroposterior supine plain pelvic radiographs. Maximum capital femoral epiphysis diameter and femoral radii were further more investigated. Hip joint space values show a slow decline during growth. Joint space was statistically significantly (p < 0.006) larger in boys than girls. Our hip joint space measurements on supine subjects seem slightly larger than those reported by Hughes on standing subjects. Evaluation of the femoral head diameter and the radii showed a size curve quite parallel to the known body growth charts. Radii medial and perpendicular to the physis are not statistically significantly different. We recommend to compare measurements of hip joint space at two locations to age dependent charts using the same imaging technique. During growth, a divergence in femoral head size from the expected values or loss of the spherical shape should raise the question of hip disorder. Clin. Anat. 30:267-275, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Cabeça do Fêmur/crescimento & desenvolvimento , Articulação do Quadril/crescimento & desenvolvimento , Adolescente , Criança , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Radiografia , Valores de Referência , Estudos Retrospectivos , Caracteres Sexuais
9.
BMC Musculoskelet Disord ; 16: 95, 2015 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-25896824

RESUMO

BACKGROUND: Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. METHODS: The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. RESULTS: The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. CONCLUSION: Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for the clinical indication of the examined cementless cups in osteoporotic bone.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteoporose/fisiopatologia , Acetábulo/diagnóstico por imagem , Acetábulo/fisiopatologia , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Densidade Óssea , Cadáver , Estudos de Casos e Controles , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Osseointegração , Osteoporose/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular , Fatores de Risco , Tomografia Computadorizada por Raios X
10.
J Spinal Disord Tech ; 27(7): 395-400, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24136052

RESUMO

STUDY DESIGN: Retrospective study. OBJECTIVE: The purpose of this study was to investigate the question whether surgical treatment of patients with spondylodiscitis and neurological deficits caused by a spinal epidural abscess (SEA) is a predictor of clinical outcome. SUMMARY OF BACKGROUND DATA: Spondylodiscitis with an accompanying SEA is a serious medical condition that is associated with potentially high risk for long-term neurological morbidity. In the literature, up to 75% of patients suffer from neurological deficits related to SEA in spondylodiscitis. Independent of treatment, residual neurology persists at a high rate. METHODS: A retrospective analysis of 135 patients admitted to our department due to a diagnosis of spondylodiscitis was performed. Presence of SEA was evaluated based on computed tomography and magnetic resonance imaging. Neurological status was documented on admission and at discharge according to the Frankel Score. In addition, our patient population was separated into group I without neurological deficits (Frankel E) and group II with abnormal Frankel A-D. Surgical and nonsurgical therapy was retrospectively evaluated. Data were statistically analyzed using the 2-sided Fisher exact test. RESULTS: On admission, 102 patients were graded as Frankel E in group I. In group II, 15 were Frankel D, 8 Frankel C, 8 Frankel B, and 2 Frankel A. After treatment, 105 patients were Frankel E, 19 Frankel D, 4 Frankel C, 3 Frankel B, and none Frankel A. Four patients died because of severe comorbidities. In group II, 13 of 33 patients had a SEA. Twelve patients showed improvement in Frankel grade, 1 remained unchanged. Of the 20 patients in group II without a SEA, 11 improved and 9 remained unchanged. Twenty-eight of the 33 patients in group II were treated surgically. Patients in both groups with improved neurology showed an upgrade by 1 or 2 Frankel scores. There was no deterioration of neurology. The correlation between surgically treated patients with SEA in comparison with patients without SEA is considered to be statistically significant. CONCLUSION: Surgical treatment of patients with spondylodiscitis and neurological deficits caused by SEA is a predictor of clinical outcome.


Assuntos
Discite/complicações , Discite/cirurgia , Abscesso Epidural/complicações , Abscesso Epidural/cirurgia , Doenças da Medula Espinal/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Discite/diagnóstico , Abscesso Epidural/diagnóstico , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/etiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Doenças da Medula Espinal/diagnóstico , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
11.
Cureus ; 16(4): e57858, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38721185

RESUMO

INTRODUCTION: Recent clinical studies confirmed that whole-body electromyostimulation (WB-EMS) training is a safe and time-efficient therapeutic method for patients with nonspecific chronic back pain (NSCBP). However, significant variations in initial pain intensity among subjects in these studies have been observed. This study aims to determine if patients with differing initial pain intensities experience varying degrees of benefit from WB-EMS and to assess the overall correlation between initial pain levels and pain reduction. METHODS: Pain intensity datasets from two studies were combined. The pooled data included 121 NSCBP patients (38 males and 83 females) with an average age of 55.1 years (±11.8 years). Data was categorized by baseline pain intensity on the numeric rating scale (NRS) into seven groups: 0 to 2, >2 to 3, >3 to 4, >4 to 5, >5 to 6, >6 to 7, and >7. Both absolute and relative changes were analyzed. Additionally, a Spearman rho correlation test was performed on the entire dataset to evaluate the relationship between initial pain level and pain reduction. RESULTS: Significant improvements were noted across all NRS11 categories, with strong effect sizes (p) in all classes above 2, ranging from 0.56 to 0.90. The >7 category exhibited the highest rate of clinically significant changes (80%) and an average improvement of 3.72 points. The overall group from >1 to 10 showed an average improvement of 1.33 points, with 37% of the participants experiencing clinically significant improvements. The Spearman rho correlation test revealed a moderate positive relationship between initial pain level and pain reduction (r_s = 0.531, p < 0.001), indicating that, generally, higher initial pain levels are associated with greater pain reduction. CONCLUSION: The findings support the hypothesis that NSCBP patients with higher baseline NRS values benefit more substantially from WB-EMS. Those with NRS values above 7 show the greatest improvement and highest rate of clinical significance. The overall positive correlation between initial pain intensity and pain reduction further underscores the efficacy of WB-EMS in managing NSCBP across different pain intensities.

12.
J Orthop Surg Res ; 19(1): 475, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39127685

RESUMO

INTRODUCTION: Arthrodesis of a (diseased) ankle joint is usually performed to achieve pain relief and stability. One basic principle of arthrodesis techniques includes rigid fixation of the surfaces until union. It seems plausible that stable anchoring and homogeneous pressure distribution should be advantageous, however, it has not been investigated yet. The aim is to achieve uniform compression, as this is expected to produce favorable results for the bony fusion of the intended arthrodesis. Numerous implants with different biomechanical concepts can be used for ankle fusion. In this study, headless compression screws (HCS, DePuy Synthes, Zuchwil, Switzerland) were compared biomechanically to an alternative fixation System, the IOFix device (Extremity Medical, Parsippany, NJ, USA) in regard to the distribution of the compression force (area of contact) and peak compression in a sawbone arthrodesis-model (Sawbones® Pacific Research Laboratories, Vashon, WA, USA). This study aims to quantify the area of contact between the bone interface that can be obtained using headless compression screws compared to the IOFix. In current literature, it is assumed, that a large contact surface with sufficient pressure between the bones brings good clinical results. However, there are no clinical or biomechanical studies, that describe the optimal compression pressure for an arthrodesis. MATERIAL AND METHODS: Two standardized sawbone blocks were placed above each other in a custom-made jig. IOFix and headless compression screws were inserted pairwise parallel to each other using a template for a uniform drilling pattern. All screws were inserted with a predefined torque of 0.5 Nm. Pressure transducers positioned between the two sawbone blocks were compressed for the measurement of peak compression force, compression distribution, and area of contact. RESULTS: With the IOFix, the compression force was distributed over significantly larger areas compared to the contact area of the HCS screws, resulting in a more homogenous contact area over the entire arthrodesis surface. Maximum compression force showed no significant difference. CONCLUSION: The IOFix system distributes the compression pressure over a much larger area, resulting in more evenly spread compression at the surface. Clinical studies must show whether this leads to a lower pseudarthrosis rate.


Assuntos
Articulação do Tornozelo , Artrodese , Parafusos Ósseos , Artrodese/métodos , Artrodese/instrumentação , Fenômenos Biomecânicos , Humanos , Articulação do Tornozelo/cirurgia , Força Compressiva
13.
Technol Health Care ; 31(5): 1867-1874, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37125586

RESUMO

BACKGROUND: Over the last 50 years arthroplasty became the gold-standard treatment for disabling conditions of the coxofemoral joint. Variations of anterior, lateral, and dorsal incision have been applied, but as each approach requires the incision and reflection of various muscles to gain adequate exposure of the joint results are still controversial. OBJECTIVE: The purpose of this study was to develop a minimal-invasive, tissue-sparing approach in sheep with reduced risks in animal testing. METHODS: 12 mature sheep underwent hip surgery as part of a study to evaluate a hip resurfacing system. In line with the preliminary cadaveric tests a modified, minimal-invasive, musclepreserving surgical approach was sought after. RESULTS: We developed a surgical approach to the coxofemoral joint in sheep using only blunt tissue dissection after skin incision without any limitations in joint exposure or increased blood loss/duration of surgery. CONCLUSION: Even though limitations occur and femoral orientation in sheep differs from man, joint forces have similar relative directions to the bone with similar bony and vascular anatomy. Therefore, this minimal-invasive muscle preserving approach might be a safe and comparable alternative in still inevitable animal testing.


Assuntos
Artroplastia de Quadril , Humanos , Animais , Ovinos , Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Articulação do Quadril , Músculos/cirurgia , Resultado do Tratamento
14.
Front Physiol ; 14: 1174103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37035684

RESUMO

Whole-Body Electromyostimulation (WB-EMS) is a training technology that enables simultaneous stimulation of all the main muscle groups with a specific impulse intensity for each electrode. The corresponding time-efficiency and joint-friendliness of WB-EMS may be particularly attractive for people unable or unmotivated to conduct (intense) conventional training protocols. However, due to the enormous metabolic and musculoskeletal impact of WB-EMS, particular attention must be paid to the application of this technology. In the past, several scientific and newspaper articles reported severe adverse effects of WB-EMS. To increase the safety of commercial non-medical WB-EMS application, recommendations "for safe and effective whole-body electromyostimulation" were launched in 2016. However, new developments and trends require an update of these recommendations to incorporate more international expertise with demonstrated experience in the application of WB-EMS. The new version of these consensus-based recommendations has been structured into 1) "general aspects of WB-EMS", 2) "preparation for training", recommendations for the 3) "WB-EMS application" itself and 4) "safety aspects during and after training". Key topics particularly addressed are 1) consistent and close supervision of WB-EMS application, 2) mandatory qualification of WB-EMS trainers, 3) anamnesis and corresponding consideration of contraindications prior to WB-EMS, 4) the participant's proper preparation for the session, 5) careful preparation of the WB-EMS novice, 6) appropriate regeneration periods between WB-EMS sessions and 7) continuous interaction between trainer and participant at a close physical distance. In summary, we are convinced that the present guideline will contribute to greater safety and effectiveness in the area of non-medical commercial WB-EMS application.

16.
BMC Musculoskelet Disord ; 13: 232, 2012 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-23181392

RESUMO

BACKGROUND: Breast cancer is the most common malignancy and the second leading cause of death in women. Because bone metastases are a common finding in patients with breast cancer, they are of major clinical concern. METHODS: In 115 consecutive patients with bone metastases secondary to breast cancer, 132 surgical procedures were performed. Medical records and imaging procedures were reviewed for age, treatment of the primary tumor, clinical symptoms, surgical treatment, complications, and survival. RESULTS: The overall survival of patients with metastatic breast cancer was dependent on the site and the amount of the metastases. Age was not a prognostic factor for survival. If the result of the orthopaedic surgery was a wide resection (R0) survival was significantly better than in the R1 (marginal resection - tumor resection in sane tissue) or R2 (intralesional resection) situation. Concerning the orthopaedic procedures there was no survival difference. CONCLUSION: In conclusion a wide (R0) resection and the absence of pathological fracture and visceral metastases were predictive for longer survival in univariate analysis. Age and the type of orthopaedic surgery had no impact on survival in multivariate analysis. The resection margins lost significance. The standard of care for patients with metastatic breast cancer to the bone requires a multidisciplinary approach.


Assuntos
Neoplasias Ósseas/secundário , Neoplasias Ósseas/cirurgia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Procedimentos Ortopédicos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
17.
Int Orthop ; 36(5): 1025-30, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22038442

RESUMO

PURPOSE: In the last 15 years, vertebroplasty and kyphoplasty have become established operative procedures for treating osteoporotic vertebral-body fractures and vertebral bodies afflicted with metastases. These procedures are quickly performed with few personnel and material resources and have a low rate of complications. However, cases of neurological impairment are reported in the scientific literature. We analysed whether potentially harmful heat is radiated/conducted by the polymerisation temperature of polymethylmethacrylate (PMMA) bone cement in the spinal canal. METHODS: We performed vertebroplasty on 25 vertebral bodies and measured the temperature distribution during polymerisation of bone cement within the spinal canal using heat probes placed in the respective areas. The vertebral bodies were located in a circulating water bath at 37°C. RESULTS: During polymerisation of the bone cement, a temperature rise was measured. The peak temperature was reached after few minutes. Temperature curves differed; a maximum temperature of up to 43.16°C was detected for a few seconds only. CONCLUSION: When vertebroplasty is performed correctly, there is no temperature development that could eventually damage the spinal cord or spinal nerves.


Assuntos
Cimentos Ósseos/efeitos adversos , Temperatura Alta , Canal Medular/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Coluna Vertebral/cirurgia , Vertebroplastia/métodos , Adulto , Idoso , Temperatura Alta/efeitos adversos , Humanos , Pessoa de Meia-Idade , Polimerização , Polimetil Metacrilato/química , Vertebroplastia/efeitos adversos
18.
Clin Biomech (Bristol, Avon) ; 92: 105589, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35144057

RESUMO

BACKGROUND: Sufficient primary stability is mandatory for successful bony prosthetic incorporation. Therefore, defined micromotion values of 150 µm should not be exceeded as higher values might compromise the ingrowth of bone trabeculae to the implant surface. The aim of this study was to evaluate the primary stability of different cementless disc prosthesis in a cadaver model. METHODS: Four different implants with different anchoring and bearing concept were tested with a target level of L4/5. 26 specimens were randomly allocated to 1 of the 4 different implants with 6 speciments in each group. Two groups were formed depending on the anchoring (spikes vs. fin) and bearing concept (non-/semi- vs. constrained). Each implant was tested regarding primary stability in a hydraulic simulator allowing simultaneous polyaxial segment movements and axial loading. The measurements were recorded on the lower plate of the prosthesis. FINDINGS: The majority of the implants showed micromotion values below 200 µm in all planes. Only one prosthesis presented borderline longitudinal amplitudes that were significant higher than the other planes. Furthermore, significant differences were observed in the sagittal plane when comparing spike and keel anchoring. Spike anchoring implants showed superior tresults to keel anchoring implants (40 µm vs. 55 µm; p = .039), while the non-/semi-constrained bearing concept was more advantageous compared to constrained group (40 µm vs. 63 µm; p = .001). INTERPRETATION: Spike anchoring and non-constrained implants might provide better primary stability.


Assuntos
Disco Intervertebral , Implantação de Prótese , Cadáver , Humanos , Desenho de Prótese , Suporte de Carga
19.
Technol Health Care ; 30(6): 1423-1434, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35754243

RESUMO

BACKGROUND: Surgical decompression is the intervention of choice for lumbar spinal stenosis (LSS) when non-operative treatment has failed. Apart from acute complications such as hematoma and infections, same-level recurrent lumbar stenosis and adjacent-segment disease (ASD) are factors that can occur after index lumbar spine surgery. OBJECTIVE: The aim of this retrospective case series was to evaluate the outcome of surgery and the odds of necessary revisions. METHODS: Patients who had undergone either decompressive lumbar laminotomy or laminotomy and spinal fusion due to lumbar spinal stenosis (LSS) between 2000 and 2011 were included in this analysis. Demographic, perioperative and radiographic data were collected. Clinical outcome was evaluated using numeric rating scale (NRS), the symptom subscale of the adapted version of the german Spinal Stenosis Measure (SSM) and patient-sreported ability to walk. RESULTS: Within the LSS- cohort of 438 patients, 338 patients underwent decompression surgery only, while instrumentation in addition to decompression was performed in 100 cases (22.3%). 38 patients had prior spinal operations (decompression, disc herniation, fusion) either at our hospital or elsewhere. Thirty-five intraoperative complications were documented with dural tear with CSF leak being the most common (33/35; 94.3%). Postoperative complications were defined as complications that needed surgery and differentiated between immediate postoperative complications (⩽ 3 weeks post operation) and complications that needed revisions surgery at a later date. Within all patients 51 revisions were classified as immediate complications of the index operation with infections, neurological deficits and hematoma being the most common. Within this group only 22 patients had fusion surgery in the first place, while 29 were treated by decompression. Revision surgery was indicated by 53 patients at a later date. While 4 patients decided against surgery, 49 revision surgeries were planned. 28 were performed at the same level, 10 at the same level plus an adjacent level, and 10 were executed at index level with indications of adjacent level spinal stenosis, adjacent level spinal stenosis plus instability and stand-alone instability. Pre- operative VAS score and ability to walk improved significantly in all patients. CONCLUSIONS: While looking for predictors of revision surgery due to re-stenosis, instability or same/adjacent segment disease none of these were found. Within our cohort no significant differences concerning demographic, peri-operative and radiographic data of patients with or without revision wer noted. Patients, who needed revision surgery were older but slightly healthier while more likely to be male and smoking. Surprisingly, significant differences were noted regarding the distribution of intraoperative and early postoperative complications among the 6 main surgeons while these weren't obious within the intial index group of late revisions.


Assuntos
Doenças da Coluna Vertebral , Fusão Vertebral , Estenose Espinal , Cirurgiões , Humanos , Masculino , Feminino , Estenose Espinal/cirurgia , Reoperação , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Descompressão Cirúrgica , Constrição Patológica/cirurgia , Doenças da Coluna Vertebral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Hematoma/cirurgia
20.
AJR Am J Roentgenol ; 197(5): 1182-9, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22021513

RESUMO

OBJECTIVE: The purpose of this study is to correlate the presence of intradiscal vacuum phenomenon on CT to that of intradiscal fluid on MRI. SUBJECTS AND METHODS: In a prospective study, 20 patients with lumbar vacuum phenomenon on CT underwent two MRI examinations. One was performed after mobilization, and the other was performed after 6 hours of bed rest. T2-weighted turbo-spin echo (TSE), STIR, T1-weighted TSE, and four consecutive T2-weighted TSE sequences were performed on a 1.5-T scanner. Ninety-five discal segments were assessed for the presence of intradiscal fluid or hyperintense signal on the T2-weighted MRI examinations and were correlated with the presence of vacuum phenomenon on CT, degenerative endplate abnormalities on CT, and edema on MRI. RESULTS: Sixty-nine of 95 discal segments (72.6%) showed vacuum phenomenon on CT. Sixteen of those 69 discal segments (23.1%) showed intradiscal fluid (n = 12) or hyperintense signal (n = 4) on MRI examinations performed after mobilization. Forty-one of 69 discal segments (59.4%) with vacuum phenomenon showed intradiscal fluid (n = 29) or hyperintense signal (n = 12) on MRI examinations performed after bed rest. Seventeen segments showed only fluid after bed rest. Nine segments showed more fluid after bed rest than after mobilization. Three segments showed an unchanged amount of fluid. There was a significant correlation between the presence of intradiscal fluid and the amount of bone marrow edema on MRI and the presence of degenerative endplate abnormalities on CT, respectively. CONCLUSION: The replacement of intradiscal vacuum phenomenon by intradiscal fluid is a time- and position-dependent dynamic process and is related to Modic type 1 degenerative disk disease and degenerative endplate changes.


Assuntos
Degeneração do Disco Intervertebral/diagnóstico , Imageamento por Ressonância Magnética , Osteocondrose/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Líquidos Corporais , Edema/diagnóstico , Edema/diagnóstico por imagem , Edema/fisiopatologia , Feminino , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/fisiopatologia , Vértebras Lombares , Masculino , Pessoa de Meia-Idade , Osteocondrose/diagnóstico por imagem , Osteocondrose/fisiopatologia , Estudos Prospectivos , Vácuo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA