1.
J Cardiovasc Electrophysiol ; 32(8): 2216-2224, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34223662

RESUMO

INTRODUCTION: Ultrahigh-density mapping for ventricular tachycardia (VT) is increasingly used. However, manual annotation of local abnormal ventricular activities (LAVAs) is challenging in this setting. Therefore, we assessed the accuracy of the automatic annotation of LAVAs with the Lumipoint algorithm of the Rhythmia system (Boston Scientific). METHODS AND RESULTS: One hundred consecutive patients undergoing catheter ablation of scar-related VT were studied. Areas with LAVAs and ablation sites were manually annotated during the procedure and compared with automatically annotated areas using the Lumipoint features for detecting late potentials (LP), fragmented potentials (FP), and double potentials (DP). The accuracy of each automatic annotation feature was assessed by re-evaluating local potentials within automatically annotated areas. Automatically annotated areas matched with manually annotated areas in 64 cases (64%), identified an area with LAVAs missed during manual annotation in 15 cases (15%), and did not highlight areas identified with manual annotation in 18 cases (18%). Automatic FP annotation accurately detected LAVAs regardless of the cardiac rhythm or scar location; automatic LP annotation accurately detected LAVAs in sinus rhythm, but was affected by the scar location during ventricular pacing; automatic DP annotation was not affected by the mapping rhythm, but its accuracy was suboptimal when the scar was located on the right ventricle or epicardium. CONCLUSION: The Lumipoint algorithm was as/more accurate than manual annotation in 79% of patients. FP annotation detected LAVAs most accurately regardless of mapping rhythm and scar location. The accuracy of LP and DP annotations varied depending on mapping rhythm or scar location.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia
2.
Pacing Clin Electrophysiol ; 44(5): 782-791, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33687764

RESUMO

Beyond pulmonary vein isolation, the two main additional strategies: Cox-Maze procedure or targeting of electrical signatures (focal bursts, rotational activities, meandering wavelets), remain controversial. High-density mapping of these arrhythmias has demonstrated firstly that a patchy lesion set is highly proarrhythmogenic, favoring macro-re-entry through conduction slowing and providing pivots for localized re-entry. Secondly, discrete anatomical structures such as the Vein or Ligament of Marshall (VOM/LOM) and the coronary sinus (CS) have epicardial muscular bundles that are more frequently involved in re-entry than previously thought. The Marshall Bundle can be ablated at any point along its course from the mid-to-distal coronary sinus to the left atrial appendage. If necessary, the VOM may be directly ablated using ethanol infusion to eliminate PV contributions and produce conduction block across the mistral isthmus. Ethanol ablation of the VOM, supplemented with RF ablation, may be more effective in producing conduction block at the mitral isthmus than repeat RF ablation alone.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ligamentos/cirurgia , Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Ligamentos/fisiopatologia
3.
J Electrocardiol ; 64: 12-13, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33260024

RESUMO

A wide QRS-complex tachycardia with 1:1 ventriculoatrial conduction may present diagnostic difficulties, and multiple pacing maneuvers are often required for an accurate diagnosis. We report a case, in which observation of transient ventriculoatrial interval variation following atrio-His block quickly led to the diagnosis.


Assuntos
Estimulação Cardíaca Artificial , Sistema de Condução Cardíaco , Eletrocardiografia , Frequência Cardíaca , Humanos , Taquicardia
4.
J Cardiovasc Electrophysiol ; 31(10): 2696-2701, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32700358

RESUMO

BACKGROUND: Data on the optimal location of the electrocardiogram (ECG) leads for the diagnosis of drug-induced long QT syndrome (diLQTS) with torsades de pointes (TdP) are lacking. METHODS: We systematically reviewed the literature for the ECGs of patients with diLQTS and subsequent TdP. We assessed T wave morphology in each lead and measured the longest QT interval in the limb and chest leads in a standardized fashion. RESULTS: Of 84 patients, 61.9% were female and the mean age was 58.8 years. QTc was significantly longer in chest versus limb leads (mean (SD) 671 (102) vs. 655 (97) ms, p = .02). Using only limb leads for QT interpretation, 18 (21.4%) ECGs were noninterpretable: 10 (11.9%) due to too flat T waves, 7 (8.3%) due to frequent, early PVCs and 1 (1.2%) due to too low ECG recording quality. In the chest leads, ECGs were noninterpretable in nine (10.7%) patients: six (7.1%) due to frequent, early PVCs, one (1.2%) due to insufficient ECG quality, two (2.4%) due to missing chest leads but none due to too flat T waves. The most common T wave morphologies in the limb leads were flat (51.0%), broad (14.3%), and late peaking (12.6%) T waves. Corresponding chest lead morphologies were inverted (35.5%), flat (19.6%), and biphasic (15.2%) T waves. CONCLUSIONS: Our results indicate that QT evaluation by limb leads only underestimates the incidence of diLQTS experiencing TdP and favors the screening using both limb and chest lead ECG.


Assuntos
Síndrome do QT Longo , Preparações Farmacêuticas , Torsades de Pointes , Complexos Ventriculares Prematuros , Eletrocardiografia , Feminino , Humanos , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/diagnóstico , Pessoa de Meia-Idade , Torsades de Pointes/induzido quimicamente , Torsades de Pointes/diagnóstico
5.
J Cardiovasc Electrophysiol ; 31(6): 1493-1506, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32333433

RESUMO

BACKGROUND: Morphology algorithms are currently recommended as a standalone discriminator in single-chamber implantable cardioverter defibrillators (ICDs). However, these proprietary algorithms differ in both design and nominal programming. OBJECTIVE: To compare three different algorithms with nominal versus advanced programming in their ability to discriminate between ventricular (VT) and supraventricular tachycardia (SVT). METHODS: In nine European centers, VT and SVTs were collected from Abbott, Boston Scientific, and Medtronic dual- and triple-chamber ICDs via their respective remote monitoring portals. Percentage morphology matches were recorded for selected episodes which were classified as VT or SVT by means of atrioventricular comparison. The sensitivity and related specificity of each manufacturer discriminator was determined at various values of template match percentage from receiving operating characteristics (ROC) curve analysis. RESULTS: A total of 534 episodes were retained for the analysis. In ROC analyses, Abbott Far Field MD (area under the curve [AUC]: 0.91; P < .001) and Boston Scientific RhythmID (AUC: 0.95; P < .001) show higher AUC than Medtronic Wavelet (AUC: 0.81; P < .001) when tested for their ability to discriminate VT from SVT. At nominal % match threshold all devices provided high sensitivity in VT identification, (91%, 100%, and 90%, respectively, for Abbott, Boston Scientific, and Medtronic) but contrasted specificities in SVT discrimination (85%, 41%, and 62%, respectively). Abbott and Medtronic's nominal thresholds were similar to the optimal thresholds. Optimization of the % match threshold improved the Boston Scientific specificity to 79% without compromising the sensitivity. CONCLUSION: Proprietary morphology discriminators show important differences in their ability to discriminate SVT. How much this impact the overall discrimination process remains to be investigated.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Telemetria/instrumentação , Potenciais de Ação , Diagnóstico Diferencial , Desenho de Equipamento , Europa (Continente) , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia
6.
Pacing Clin Electrophysiol ; 43(3): 332-340, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32039491

RESUMO

BACKGROUND: Loss of biventricular stimulation can result in nonresponse to cardiac resynchronization therapy (CRT). Problems associated with the left ventricular (LV) lead and LV sensing can be challenging to detect and their incidence is unclear. The purpose of this study was to investigate mechanisms of loss of biventricular pacing due to LV lead- and LV sensing-associated problems. METHODS: In this bicentric study, CRT patients were surveilled using a novel remote monitoring algorithm from Biotronik (Germany) that registers LV electrograms (EGMs) during intermittent loss of resynchronization. The episodes were analyzed to assess the mechanisms of resynchronization interruptions. RESULTS: We analyzed 582 EGMs from 61 patients. During a median follow-up of 6 months, 59% of the patients had such episodes. The majority of the episodes (61%) were related to inappropriate inhibition of LV pacing, mostly due to upper rate lock-in caused by LV sensing (58%). In contrast, 8% of episodes showed intermittent loss of LV capture, which was identified thanks to LV sensing. The remaining 31% of episodes were due to physiological reasons for resynchronization interruptions (eg, supraventricular tachycardia [18%], premature beats [8%], and others [5%]). Patients with CRT interruption episodes had lower resynchronization rates (median: 98.5% vs 100%, P = .044). CONCLUSIONS: Inadequate programming (active LV sensing with T-wave protection) is the main cause of impaired resynchronization in devices with LV sensing. In general, we recommend the deactivation of the LV T-wave protection function.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Disfunção Ventricular Esquerda/terapia , Idoso , Algoritmos , Eletrocardiografia , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Disfunção Ventricular Esquerda/fisiopatologia
7.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32627211

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Coração Auxiliar , Idoso , França , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
8.
J Cardiovasc Electrophysiol ; 30(8): 1352-1361, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31231884

RESUMO

INTRODUCTION: Some cardiac resynchronization therapy (CRT) device manufacturers (Biotronik, Germany; Boston Scientific, United States) have implemented left ventricular (LV) sensing functionality to prevent pacing into the vulnerable phase. Physicians are only partially aware of programming pitfalls related to LV sensing and general programming advice is lacking. METHODS AND RESULTS: We provide an illustrative case-series-based review of the variety of potential problems with LV sensing. LV sensing may inappropriately impair CRT delivery due to LV-sensing issues or improper device programming. This can cause beat-wise loss of resynchronization but also ongoing desynchronization. On the other hand, LV sensing provides additional diagnostic information, which may reveal intermittent problems of the LV lead such as capture loss. We summarize the available evidence to provide manufacturer-specific recommendations on device programming and troubleshooting for daily clinical practice. CONCLUSION: CRT devices with LV sensing may suffer from impaired resynchronization due to programming pitfalls. If LV sensing is active (nominal setting in Biotronik and Boston Scientific devices), careful lookout for related problems and resynchronization percentage is required. Optimization is mandatory and even deactivation of LV sensing may have to be considered.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Tecnologia de Sensoriamento Remoto/instrumentação , Processamento de Sinais Assistido por Computador , Volume Sistólico , Função Ventricular Esquerda , Terapia de Ressincronização Cardíaca/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Valor Preditivo dos Testes , Tecnologia de Sensoriamento Remoto/efeitos adversos , Fatores de Risco , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 42(4): 478-482, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30515880

RESUMO

SecureSense is an implantable cardioverter defibrillator algorithm that differentiates lead-related oversensing from ventricular tachycardia/ventricular fibrillation by continuous comparison between the near-field (NF) and the far-field (FF) electrogram. If lead noise is identified, inappropriate therapy is withheld. Undersensing on the FF channel could result in inappropriate inhibition of life-saving therapy. Thus, the device automatically switches SecureSense to passive mode if undersensing on the FF channel is suspected. We report here the first cases of inappropriate automatic SecureSense deactivation due to misdiagnosed FF undersensing in pacemaker-dependent patients. Physicians should be aware that SecureSense does not withhold an inappropriate therapy for sustained oversensing in pacemaker-dependent patients.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Análise de Falha de Equipamento , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Desenho de Equipamento , Humanos , Masculino , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico
10.
J Cardiovasc Electrophysiol ; 29(8): 1125-1134, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29858871

RESUMO

INTRODUCTION: Recognition of implantable cardioverter defibrillator (ICD) lead malfunction before occurrence of life threatening complications is crucial. We aimed to assess the effectiveness of remote monitoring associated or not with a lead noise alert for early detection of ICD lead failure. METHODS: From October 2013 to April 2017, a median of 1,224 (578-1,958) ICD patients were remotely monitored with comprehensive analysis of all transmitted materials. ICD lead failure and subsequent device interventions were prospectively collected in patients with (RMLN) and without (RM) a lead noise alert (Abbott Secure Sense™ or Medtronic Lead Integrity Alert™) in their remote monitoring system. RESULTS: During a follow-up of 4,457 patient years, 64 lead failures were diagnosed. Sixty-one (95%) of the diagnoses were made before any clinical complication occurred. Inappropriate shocks were delivered in only one patient of each group (3%), with an annual rate of 0.04%. All high voltage conductor failures were identified remotely by a dedicated impedance alert in 10 patients. Pace-sense component failures were correctly identified by a dedicated alert in 77% (17 of 22) of the RMLN group versus 25% (8 of 32) of the RM group (P = 0.002). The absence of a lead noise alert was associated with a 16-fold increase in the likelihood of initiating either a shock or ATP (OR: 16.0, 95% CI 1.8-143.3; P = 0.01). CONCLUSION: ICD remote monitoring with systematic review of all transmitted data is associated with a very low rate of inappropriate shocks related to lead failure. Dedicated noise alerts further reduce inappropriate detection of ventricular arrhythmias.


Assuntos
Alarmes Clínicos , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Análise de Falha de Equipamento/métodos , Falha de Equipamento , Tecnologia de Sensoriamento Remoto/métodos , Adulto , Idoso , Alarmes Clínicos/tendências , Desfibriladores Implantáveis/tendências , Eletrodos Implantados/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
JACC Clin Electrophysiol ; 9(10): 2054-2066, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37715740

RESUMO

BACKGROUND: Substrate abnormalities can alter atrial activation during atrial tachycardias (ATs) thereby influencing AT-wave morphology on the surface electrocardiogram. OBJECTIVES: This study sought to identify determinants of isoelectric intervals during ATs with complex atrial activation patterns. METHODS: High-density activation maps of 126 ATs were studied. To assess the impact of the activated atrial surface on the presence of isoelectric intervals, this study measured the minimum activated area throughout the AT cycle, defined as the smallest activated area within a 50-millisecond period, by using signal processing algorithms (LUMIPOINT). RESULTS: ATs with isoelectric intervals (P-wave ATs) included 23 macro-re-entrant ATs (40%), 26 localized-re-entrant ATs (46%), and 8 focal ATs (14%), whereas those without included 46 macro-re-entrant ATs (67%), 21 localized-re-entrant ATs (30%), and 2 focal ATs (3%). Multivariable regression identified smaller minimum activated area and larger very low voltage area as independent predictors of P-wave ATs (OR: 0.732; 95% CI: 0.644-0.831; P < 0.001; and OR: 1.042; 95% CI: 1.006-1.080; P = 0.023, respectively). The minimum activated area with the cutoff value of 10 cm2 provided the highest predictive accuracy for P-wave ATs with sensitivity, specificity, and positive and negative predictive values of 96%, 97%, 97%, and 95%, respectively. In re-entrant ATs, smaller minimum activated area was associated with lower minimum conduction velocity within the circuit and fewer areas of delayed conduction outside of the circuit (standardized ß: 0.524; 95% CI: 0.373-0.675; P < 0.001; and standardized ß: 0.353; 95% CI: 0.198-0.508; P < 0.001, respectively). CONCLUSIONS: Reduced atrial activation area and voltage were associated with isoelectric intervals during ATs.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Eletrocardiografia
14.
Circ Arrhythm Electrophysiol ; 16(10): e012241, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37728002

RESUMO

BACKGROUND: Abnormal atrial potentials (AAPs) recorded during sinus rhythm/atrial pacing may indicate areas of slow conduction capable of supporting reentrant atrial tachycardia (AT). Therefore, we sought to examine the relationship between AAPs and AT circuits. METHODS: One hundred twenty-three reentrant ATs in 104 patients were analyzed. AAPs, consisting of fragmented potentials and split potentials, were assessed using the Rhythmia LUMIPOINT algorithm. RESULTS: There was 93±13% overlap between areas with AAPs during sinus rhythm/atrial pacing and areas of slow conduction along the reentry circuit during AT. The cumulative area of AAPs was smaller in patients with localized-reentrant ATs compared with anatomic macro-reentrant ATs (20.0 [14.6-30.5] versus 28.9 [21.8-35.6] cm2; P=0.021). Patients with perimitral ATs had larger areas of AAPs on the lateral wall whereas patients with roof-dependent ATs had larger areas of AAPs on the roof and posterior wall (P≤0.018 for all comparisons). The patchy scar that was associated with localized-reentrant AT exhibited a larger area of AAPs at its periphery than the scar that did not participate in localized-reentrant AT (3.1 [2.4-4.5] versus 1.0 [0.7-1.6] cm2; P<0.001). CONCLUSIONS: AAPs recorded during sinus rhythm/atrial pacing are associated with areas of slow conduction during reentrant AT. The burden and distribution of AAPs may provide actionable insights into AT circuit features, including in cases in which ATs are difficult to map.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Átrios do Coração , Frequência Cardíaca , Estimulação Cardíaca Artificial
15.
Heart Rhythm ; 19(5): 701-709, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35033665

RESUMO

BACKGROUND: An understanding of normal atrial activation during sinus rhythm can inform catheter ablation strategies to avoid deleterious impacts of ablation lesions on atrial conduction and mechanics. OBJECTIVE: The purpose of this study was to describe how the sinus node impulse originates, propagates, and collides in right and left atria with normal voltage. METHODS: Fifty consecutive patients undergoing catheter ablation of atrial fibrillation with endocardial atrial voltage >0.5 mV during high-density 3-dimensional mapping were studied. RESULTS: Sinus node exits varied among patients along a lateral oblique arc extending from the anterior aspect of the superior vena cava (SVC) to the mid-posterior wall of the right atrium (RA). Conduction slowing or block at one of the smooth components that faces the crista terminalis was observed in 54% of cases, including complete block at the SVC musculature and systemic venous sinus in 6% of cases. Depending on these 2 key features of RA activation, interatrial conduction was mediated by the Bachmann bundle (64%) and posterior bundles (54%), with an overlap of the resulting left atrial breakthrough location. Wavefront collision was consistently observed at 3 sites: the septal aspect of the cavotricuspid isthmus, and the lower aspects of the dome and of the mitral isthmus. CONCLUSION: During sinus rhythm, atrial activation occurs via distinct sequences mediated by a complex interaction of anatomic factors.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração , Humanos , Nó Sinoatrial , Veia Cava Superior/patologia
16.
Heart Rhythm ; 18(11): 1951-1958, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34217842

RESUMO

BACKGROUND: Mitral isthmus gaps have been ascribed to an epicardial musculature anatomically related to the great cardiac vein (GCV) and the vein of Marshall (VOM). Their lumen offers an access for radiofrequency application or ethanol infusion, respectively. OBJECTIVE: The purpose of this study was to evaluate the frequency of mitral isthmus gaps accessible via the GCV lumen, to assess their location around the GCV circumference, and to propose an efficient ablation strategy when present. METHODS: One hundred consecutive patients underwent VOM ethanol infusion (step 1) and endocardial linear ablation from the mitral annulus to the left inferior pulmonary vein (step 2). In cases of mitral isthmus gap, endovascular ablation of the GCV anchored wall facing the left atrium was systematically performed (step 3), while the opposite GCV free wall was targeted in case of block failure only (step 4). RESULTS: After VOM ethanol infusion and endocardial ablation, mitral isthmus block occurred in 51 patients (51%). Pacing maneuvers and activation sequences demonstrated an epicardial gap via the VOM in 2 patients (2%) and via the GCV in 47 patients (47%). In the latter case, block was achieved at the GCV anchored wall in 42 patients (89%) and the GCV free wall in 5 patients (11%). Global success rate of mitral isthmus block was 98%. No tamponade occurred. CONCLUSION: With the advent of VOM ethanol infusion, residual mitral isthmus gaps are mostly eliminated within the first centimeter of the GCV. Thorough mapping of the entire circumference of the GCV wall can help identify these epicardial gaps.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Vasos Coronários/anatomia & histologia , Etanol/administração & dosagem , Músculo Liso Vascular/anatomia & histologia , Veias/anatomia & histologia , Idoso , Mapeamento Epicárdico , Feminino , Bloqueio Cardíaco/etiologia , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Pericárdio/anatomia & histologia
17.
Heart Rhythm ; 18(10): 1647-1654, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34260987

RESUMO

BACKGROUND: Purkinje ectopics (PurkEs) are major triggers of idiopathic ventricular fibrillation (VF). Identifying clinical factors associated with specific PurkE characteristics could yield insights into the mechanisms of Purkinje-mediated arrhythmogenicity. OBJECTIVE: The purpose of this study was to examine the associations of clinical, environmental, and genetic factors with PurkE origin in patients with PurkE-initiated idiopathic VF. METHODS: Consecutive patients with PurkE-initiated idiopathic VF from 4 arrhythmia referral centers were included. We evaluated demographic characteristics, medical history, clinical circumstances associated with index VF events, and electrophysiological characteristics of PurkEs. An electrophysiology study was performed in most patients to confirm the Purkinje origin. RESULTS: Eighty-three patients were included (mean age 38 ± 14 years; 44 [53%] women), of whom 32 had a history of syncope. Forty-four patients had VF at rest. PurkEs originated from the right ventricle (RV) in 41 patients (49%), from the left ventricle (LV) in 36 (44%), and from both ventricles in 6 (7%). Seasonal and circadian distributions of VF episodes were similar according to PurkE origin. The clinical characteristics of patients with RV vs LV PurkE origins were similar, except for sex. RV PurkEs were more frequent in men than in women (76% vs 24%), whereas LV and biventricular PurkEs were more frequent in women (81% vs 19% and 83% vs 17%, respectively) (P < .0001). CONCLUSION: PurkEs triggering idiopathic VF originate dominantly from the RV in men and from the LV or both ventricles in women, adding to other sex-related arrhythmias such as Brugada syndrome or long QT syndrome. Sex-based factors influencing Purkinje arrhythmogenicity warrant investigation.


Assuntos
Eletrocardiografia , Ventrículos do Coração/fisiopatologia , Ramos Subendocárdicos/fisiopatologia , Medição de Risco/métodos , Fibrilação Ventricular/epidemiologia , Complexos Ventriculares Prematuros/epidemiologia , Adulto , Angiografia Coronária , Ecocardiografia , Feminino , França/epidemiologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Incidência , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Ramos Subendocárdicos/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Fatores Sexuais , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Complexos Ventriculares Prematuros/complicações , Complexos Ventriculares Prematuros/diagnóstico
18.
Heart Rhythm ; 18(7): 1115-1121, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33812085

RESUMO

BACKGROUND: Little is known about persistent atrial fibrillation (AF) ablation in patients with cardiac laminopathy (CLMNA). OBJECTIVES: We aimed to characterize atrial electrophysiological properties and to assess the long-term outcomes of persistent AF ablation in patients with CLMNA. METHODS: All patients with CLMNA referred in our center for persistent AF ablation were retrospectively included. Left atrial (LA) volume, left atrial appendage (LAA) cycle length, interatrial conduction delay, and LA voltage amplitude were analyzed during the ablation procedure. Sinus rhythm maintenance and LA contractile function were assessed during long-term follow-up. RESULTS: From 2011 to 2020, 8 patients were included. The mean age was 47 ± 14 years, and 3 patients (38%) were women. The LA volume was 205.8 ± 43.7 mL; the LAA AF cycle length was 250.7 ± 85.6 ms; and the interatrial conduction delay was 296.5 ± 110.1 ms. Large low-voltage areas (>50% of the LA surface; <0.5 mV electrogram) were recorded in all 8 patients. Two patients had inadvertent LAA disconnection during ablation. All A waves recorded by pulsed Doppler in sinus rhythm were <30 cm/s before and after AF ablation. Early arrhythmia recurrence was recorded in 7 patients (87%) (time to recurrence 4 ± 4 months; 1.5 procedures per patient). After a mean follow-up of 4.4 ± 3.2 years, 4 patients underwent implantable cardioverter-defibrillator therapy for life-threatening ventricular arrhythmia and 3 patients finally underwent heart transplantation. CONCLUSION: Patients with persistent AF afflicted by CLMNA exhibit severe LA impairment because of large low-voltage areas, prolonged conduction velocity, and reduced contractile function. Ablation procedures have a limited effect with a high recurrence rate.


Assuntos
Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos
19.
Heart Rhythm ; 18(3): 349-357, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33188900

RESUMO

BACKGROUND: Gaps in the roof line have been ascribed to epicardial conduction using the septopulmonary bundle. OBJECTIVES: We sought to evaluate the frequency of septopulmonary bundle bypass during roof line ablation, to describe anatomical conditions favoring this epicardial gap, and to propose an alternative strategy when present. METHODS: One hundred consecutive patients underwent atrial fibrillation ablation. A de novo roof line was created between the superior pulmonary veins. In cases of residual gaps, a floor line was created between the inferior pulmonary veins. Microtomography imaging and histological analyses of 5 human donor hearts were performed: a specific focus was made on the dome and the posterior wall. RESULTS: Residual gaps were more frequent in roof lines than floor lines (33% vs 15%; P = .049). Electrogram morphologies, activation sequences, and pacing maneuvers indicated an epicardial bypass of the roof line in all cases. Conduction block was obtained in 67 roof lines and 28 floor lines, resulting in a 95% success rate of linear block, without "box" isolation. Between the superior pulmonary veins, the atrial myocardium was thicker and consistently displayed adipose tissue separating the septopulmonary bundle from the septoatrial bundle. CONCLUSION: Epicardial conduction across the roof line is common and requires careful electrogram analysis to detect. In such cases, a floor line can be an effective alternative strategy, with clear validation criteria. Myocardial thickness and fat interposition may explain difficulties in achieving lesion transmurality during roof line ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Tomografia com Microscopia Eletrônica/métodos , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
20.
Heart Rhythm ; 17(12): 2072-2077, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32739474

RESUMO

BACKGROUND: The Heart Rhythm Society, the European Heart Rhythm Association, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society expert consensus statement on optimal implantable cardioverter-defibrillator programming recommends burst antitachycardia pacing (ATP) for the treatment of ventricular tachycardia (VT) up to high rates. The number of bursts is not specified, and treatment by ramps or low-energy shocks is not recommended. OBJECTIVES: We investigated the efficacy and safety of progressive therapies for VTs between 150 and 200 beats/min. After 3 failed bursts, we compared 3 ramps vs 3 bursts followed by a low-energy shock vs high-energy shock. METHODS: Using remote monitoring, we included monomorphic VT episodes treated with ≥1 burst. RESULTS: A total of 1126 VT episodes were included. A single burst was as likely to terminate VT between 150 and 200 beats/min as VT between 200 and 230 beats/min (63% vs 64%; P=.41), but was more likely to accelerate the latter (3.2% vs 0.25%; P<.01). For VT <200 beats/min, the likelihood of ATP success increased progressively (73% with 2 bursts, 78% with 3 bursts). Three additional bursts further increased VT termination to 89%, similar to the success rate with 3 additional ramps (88%; P=.17). Programming 6 bursts is associated with the probability of acceleration requiring shock of 6.6%. A low-energy first shock was less successful than a high-energy shock (66% vs 86%; P<.01) and more likely to accelerate VT (17% vs 0%; P<.01). CONCLUSION: Programming up to 6 burst ATP therapies for VTs 150-200 beats/min can avoid implantable cardioverter-defibrillator shocks in most patients. Ramp ATP after failed bursts were similarly effective. Low-energy shocks are less effective and more arrhythmogenic than high-energy shocks.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Eletrocardiografia , Frequência Cardíaca/fisiologia , Taquicardia Ventricular/terapia , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Taquicardia Ventricular/fisiopatologia