RESUMO

AIMS: To compare 5-year angiographic, optical coherence tomography (OCT), and clinical outcomes between patients treated with bioresorbable vascular scaffolds (BVS) and drug-eluting stents (DES). METHODS: The EverBio-2 trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) was a single-center, assessor-blinded, randomized controlled trial in which 240 patients were randomly allocated (1:1:1) to BVS, everolimus-eluting (EES) or biolimus-eluting (BES) DES. Clinical follow-up was scheduled up to 5 years. All patients, alive and who did not have repeat revascularization of the target lesion during follow-up were asked to return for angiographic follow-up at 5 years. RESULTS: Five-year angiographic follow-up was completed in 122 patients (51%) and OCT analysis was performed in 86 (36%) patients. In-stent late lumen loss was similar in both groups with 0.50 ± 0.38 mm in BVS versus 0.58 ± 0.36 mm in EES/BES, p = 0.20. Clinical follow-up was complete in 232 patients (97%) at 5 years. The rate of the device-oriented endpoint was 22% in the BVS and 18% in the EES/BES group (p = 0.49). The patient-oriented composite endpoint occurred in 40% of BVS- and 43% of EES/BES-treated patients (p = 0.72) at 5 years. No acute coronary syndrome due to stent thrombosis was detected after 2 years. Complete BVS strut resorption was observed at 5 years in the OCT subgroup. CONCLUSION: Five-year clinical outcomes were similar between BVS and DES patients as well as angiographic outcomes in a selected subgroup. However, a definitive conclusion cannot be drawn because the EverBio-2 trial was not powered for clinical and angiographic endpoints at 5 years of follow-up.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Stents Farmacológicos/efeitos adversos , Everolimo/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo/efeitos adversos , Stents , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 98(5): E768-E779, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33857355

RESUMO

OBJECTIVES: To investigate the impact of transcatheter heart valve (THV) sizing on procedural results and clinical outcomes following transcatheter aortic valve implantation (TAVI). BACKGROUND: The impact of individual THV sizing for patients with borderline aortic annulus anatomy remains unclear. METHODS: In the prospective BernTAVI registry, THV sizing conditions were retrospectively evaluated, and patients were categorized into three groups based on the recommendations and the sizing chart of the manufacturers: optimal sizing, borderline sizing (THV size located within 5% to each border of the optimal sizing recommendation), and suboptimal sizing (THV size outside the recommended range). The latter two groups were further subcategorized into THV-oversizing and THV-undersizing. The primary endpoint was a composite of all-cause death and unplanned repeat intervention at 1 year. RESULTS: Out of a total of 1,638 patients who underwent TAVI, 9.5 and 15.6% of patients were categorized into the borderline and suboptimal sizing group, respectively. Device success was achieved in 87.4, 88.9, and 83.6% of patients with optimal, borderline, and suboptimal sizing, respectively. The primary endpoint occurred in 12.3% of patients with optimal sizing, 14.9% of patients with borderline sizing (HRadj 1.35, 95%CI 0.87-2.09), and in 17.4% of patients with suboptimal sizing (HRadj 1.42, 95%CI 1.01-1.99). Within the suboptimal sizing cohort, unfavorable outcomes were mainly associated with THV undersizing (device success: 76.4%, primary endpoint: 23.9%, HRadj 1.98, 95%CI 1.36-2.87). CONCLUSION: Suboptimal TAVI prosthesis sizing is associated with an increased risk of all-cause death and unplanned repeat intervention within 1 year largely attributable to undersized THV prostheses.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Estudos Prospectivos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 93(6): 1116-1123, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30773838

RESUMO

AIMS: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry. METHODS AND RESULTS: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm2 to 1.7 ± 0.4 cm2 (P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM-naïve patients was 22.2% (6/27). CONCLUSIONS: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Europa (Continente) , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , América Latina , Masculino , Nova Zelândia , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
4.
Eur Heart J ; 38(36): 2729-2738, 2017 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-28633375

RESUMO

AIMS: The ADVANCE study was designed to evaluate the safety and effectiveness of transcatheter aortic valve implantation (TAVI) with a self-expanding bioprosthesis in real-world patients with symptomatic, severe aortic stenosis at high surgical risk for valve replacement. METHODS AND RESULTS: Study participants were enrolled from 44 experienced centres in 12 countries. Patient eligibility, treatment approach, and choice of anaesthesia were determined by the local Heart Team. The study was 100% monitored, and adverse events were adjudicated by an independent clinical events committee using Valve Academic Research Consortium (VARC-1) criteria. There were 1015 patients enrolled with 996 attempted TAVI procedures. Mean age was 81 years, and mean logistic EuroSCORE was 19.3 ± 12.3%. Five-year follow-up was available on 465 (46.7%) patients. At 5 years, the rate of all-cause mortality was 50.7% (95% confidence interval: 46.7%, 54.5%), and the rate of major stroke was 5.4%. Haemodynamic measures remained consistent for paired patients with a mean aortic valve gradient of 8.8 ± 4.4 mmHg (n = 198) and an effective orifice area of 1.7 ± 0.4 cm2 (n = 123). Aortic regurgitation (AR) decreased over time and among paired patients dropped from 12.8% to 8.0% moderate AR at 5 years (n = 125). Of the 860 patients with echocardiographic data or a reintervention after 30 days, there were 22 (2.6%) patients meeting the VARC-2 criteria for valve dysfunction and 10 (1.2%) patients with a reintervention >30 days. CONCLUSION: Five-year results in real-world, elderly, high-risk patients undergoing TAVI with a self-expanding bioprosthesis provided evidence for continued valve durability with low rates of reinterventions and haemodynamic valve dysfunction. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01074658.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Valva Aórtica , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Falha de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
Eur Heart J ; 38(28): 2211-2217, 2017 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-28430920

RESUMO

AIMS: To analyse reasons, timing and predictors of hospital readmissions after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: Patients included in the Bern TAVI Registry between August 2007 and June 2014 were analysed. Fine and Gray competing risk regression was used to identify factors predictive of hospital readmission within 1 year after TAVI with bootstrap analysis for internal validation. Of 868 patients alive at discharge, 221 (25.4%) were readmitted within 1 year. Compared with patients not requiring readmission, those with at least one readmission more frequently were male and more often had atrial fibrillation and higher creatinine values (P < 0.05 for all cases). For overall 308 readmissions, cardiovascular causes accounted for 46.1% with heart failure as the most frequent indication; non-cardiovascular readmissions occurred for surgery (11.7%), gastrointestinal disorders (9.7%), malignancy (4.9%), respiratory diseases (4.6%) and chronic kidney failure (2.6%). Male gender (subhazard ratio, SHR, 1.33, 95% confidence intervals, CI, 1.02-1.73, P = 0.035) and stage 3 kidney injury (SHR 2.04, 95% CI 1.12-3.71, P = 0.021) were found independent risk factors for any hospital readmission, whereas previous myocardial infarction (SHR 1.88, 95% CI 1.22-2.90, P = 0.004) and in-hospital life-threatening bleeding (SHR 2.18, 95%CI 1.24-3.85, P = 0.007) were associated with cardiovascular readmissions. The event rate for mortality was significantly increased after readmissions for any cause (RR 4.29, 95% CI 2.86-6.42, P < 0.001). CONCLUSION: Hospital readmission was observed in one out of four patients during the first year after TAVI and was associated with a significant increase in mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Readmissão do Paciente/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/mortalidade , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Feminino , Humanos , Tempo de Internação , Masculino , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Prospectivos , Sistema de Registros , Análise de Regressão , Suíça/epidemiologia
6.
Eur Heart J ; 38(45): 3359-3366, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28651336

RESUMO

AIMS: RESPOND is a prospective, open-label, single-arm study evaluating the outcomes following transcatheter aortic valve implantation (TAVI) with the repositionable and fully retrievable Lotus Valve used in routine clinical practice for the treatment of patients with aortic valve stenosis. METHODS AND RESULTS: RESPOND enrolled 1014 patients at sites across Europe, New Zealand, and Latin America; 996 patients received a Lotus Valve (mean age: 80.8 years; 50.8% female; Society of Thoracic Surgeons score: 6.0 ± 6.9). Repositioning was attempted in 29.2% of patients, with 99% success. The rate of all-cause mortality in the intent-to-treat population at 30 days (primary endpoint) was 2.6% (P < 0.001 vs. pre-specified performance goal). Thirty-day clinical follow-up was completed for 97.3% of patients. Among patients who received a Lotus Valve, the 30-day overall and disabling stroke rates were 3.0% and 2.2%, respectively. The 30-day permanent pacemaker implantation rate was 30.0% in all patients, and 34.6% in pacemaker-naïve patients. Echocardiographic data at baseline and pre-discharge were assessed by an independent core laboratory. Mean aortic valve gradient declined from 37.7 ± 15.2 mmHg at baseline to 10.8 ± 4.6 mmHg at hospital discharge (P < 0.001). Aortic valve area increased from 0.7 ± 0.2 cm2 at baseline to 1.8 ± 0.4 cm2 at discharge (P < 0.001). At hospital discharge, paravalvular leak (PVL) was absent or trace in 92% of patients; no patients had severe PVL, 0.3% of patients exhibited moderate PVL, and 7.7% of patients had mild PVL. Clinical follow-up in RESPOND will extend to 5 years. CONCLUSION: The results of RESPOND confirm the safety and efficacy of TAVI with the Lotus Valve in routine clinical practice. TRIAL REGISTRATION: ClinicalTrials.gov #NCT 02031302.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Medidas de Resultados Relatados pelo Paciente , Segurança do Paciente , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Sistema de Registros , Reoperação/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
Am Heart J ; 184: 71-80, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27892889

RESUMO

BACKGROUND: Among patients undergoing transcatheter aortic valve implantation (TAVI), concomitant mitral regurgitation (MR) has been associated with adverse prognosis. We aimed to assess long-term clinical outcomes according to MR etiology. METHODS: In a single-center registry of consecutive patients undergoing TAVI, we investigated the impact of functional (FMR) vs degenerative (DMR) MR on cardiovascular (CV) mortality throughout 2years of follow-up. RESULTS: Among 603 patients (mean age 82.4±5.7years, 55% female) undergoing TAVI, 149 patients had moderate or severe MR (24.7%). Functional MR and DMR were documented in 53 (36%) and 96 (64%) patients, respectively. At 2years, patients with FMR and DMR had higher rates of CV mortality (30.2% vs 32.4%) as compared with patients with no MR (14.6%; FMR vs no MR: hazard ratio [HR] 2.32, 95% CI 1.34-4.02, P=.003; DMR vs no MR: HR 2.56, 95% CI 1.66-3.96, P<.001). In adjusted analyses, DMR was associated with an increased risk of CV mortality throughout the 2-year follow-up (adjusted HR 2.21, 95% CI 1.4-3.49, P=.001) as compared with FMR (adjusted HR 1.13, 95% CI 0.59-2.18, P=.707). Relevant MR was postprocedurally significantly reduced in both the DMR and FMR groups, whereas improvement of a decreased left ventricular ejection fraction was predominantly seen in the FMR group as compared with baseline. CONCLUSION: Patients with severe, symptomatic aortic stenosis undergoing TAVI complicated by moderate or severe MR portend impaired prognosis. Particularly, patients with DMR are at increased risk for CV mortality during long-term follow-up.


Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Modelos de Riscos Proporcionais , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter
8.
Eur Heart J ; 36(32): 2167-76, 2015 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-26040806

RESUMO

AIMS: The purpose of the present study was to investigate the relationship between in-stent neoatherosclerosis (NA) and native atherosclerosis progression of untreated coronary segments. METHODS AND RESULTS: In-stent NA was assessed by optical coherence tomography (OCT) among patients included in the SIRTAX-LATE OCT study 5 years after drug-eluting stent (DES) (sirolimus-eluting and paclitaxel-eluting stents) implantation. Neoatherosclerosis was defined as the presence of fibroatheroma or fibrocalcific plaque within the neointima of stented segments with a longitudinal extension >1.0 mm. Atherosclerosis progression in untreated native coronary segments was evaluated by serial quantitative coronary angiography (QCA). The change in minimal lumen diameter (MLD) was serially assessed within matched segments at baseline and 5-year angiographic follow-up. The key clinical endpoint was non-target lesion (non-TL) revascularization throughout 5 years. A total of 88 patients with 88 lesions were available for OCT analysis 5 years after DES implantation. In-stent NA was observed in 16% of lesions with the majority of plaques being fibroatheromas (11.4%) followed by fibrocalcific plaques (5.7%). A total of 704 non-TL segments were serially evaluated by QCA. Between baseline and 5-year follow-up, the reduction in MLD was significantly more pronounced in patients with NA (-0.25 mm, 95% CI -0.36 to -0.17 mm) when compared with patients without NA (-0.13 mm, 95% CI -0.17 to -0.10 mm, P = 0.002). Similarly, non-TL revascularization was more frequent in patients with NA (78.6%) when compared with patients without NA (44.6%, P = 0.028) throughout 5 years. CONCLUSIONS: In-stent NA is more common among patients with angiographic and clinical evidence of native atherosclerosis progression suggesting similar pathophysiological mechanisms.SIRTAX trial is registered at http://www.clinicaltrials.gov/ct2/show/NCT00617084.


Assuntos
Estenose Coronária/patologia , Stents Farmacológicos , Oclusão de Enxerto Vascular/patologia , Paclitaxel , Idoso , Angiografia Coronária , Reestenose Coronária/patologia , Estenose Coronária/cirurgia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Paclitaxel/administração & dosagem , Falha de Prótese , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica/métodos , Moduladores de Tubulina/administração & dosagem
9.
Lancet ; 384(9960): 2111-22, 2014 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-25189359

RESUMO

BACKGROUND: Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS: We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS: Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION: In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING: Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.


Assuntos
Antibacterianos/uso terapêutico , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Implantes Absorvíveis , Idoso , Antibacterianos/administração & dosagem , Everolimo , Feminino , Humanos , Masculino , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/instrumentação , Polímeros , Método Simples-Cego , Sirolimo/administração & dosagem , Resultado do Tratamento
10.
Eur Heart J ; 35(37): 2530-40, 2014 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24682843

RESUMO

AIM: The aim of this study was to evaluate whether coronary artery disease (CAD) severity exerts a gradient of risk in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: A total of 445 patients with severe AS undergoing TAVI were included into a prospective registry between 2007 and 2012. The preoperative SYNTAX score (SS) was determined from baseline coronary angiograms. In case of revascularization prior to TAVI, residual SS (rSS) was also determined. Clinical outcomes were compared between patients without CAD (n = 158), patients with low SS (0-22, n = 207), and patients with high SS (SS > 22, n = 80). The pre-specified primary endpoint was the composite of cardiovascular death, stroke, or myocardial infarction (MI). At 1 year, CAD severity was associated with higher rates of the primary endpoint (no CAD: 12.5%, low SS: 16.1%, high SS: 29.6%; P = 0.016). This was driven by differences in cardiovascular mortality (no CAD: 8.6%, low SS: 13.6%, high SS: 20.4%; P = 0.029), whereas the risk of stroke (no CAD: 5.1%, low SS: 3.3%, high SS: 6.7%; P = 0.79) and MI (no CAD: 1.5%, low SS: 1.1%, high SS: 4.0%; P = 0.54) was similar across the three groups. Patients with high SS received less complete revascularization as indicated by a higher rSS (21.2 ± 12.0 vs. 4.0 ± 4.4, P < 0.001) compared with patients with low SS. High rSS tertile (> 14) was associated with higher rates of the primary endpoint at 1 year (no CAD:12.5%, low rSS: 16.5%, high rSS: 26.3%, P = 0.043). CONCLUSIONS: Severity of CAD appears to be associated with impaired clinical outcomes at 1 year after TAVI. Patients with SS > 22 receive less complete revascularization and have a higher risk of cardiovascular death, stroke, or MI than patients without CAD or low SS.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/complicações , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/patologia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/patologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
11.
Eur Heart J ; 35(38): 2672-84, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-24682842

RESUMO

AIM: Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre 'real-world' patient population in highly experienced centres. METHODS AND RESULTS: Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. CONCLUSION: The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/mortalidade , Causas de Morte , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 84(7): 1190-6, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24399612

RESUMO

OBJECTIVES: To assess feasibility and outcomes of left atrial appendage (LAA) closure when using a patent foramen ovale (PFO) for left atrial access. BACKGROUND: Because of the fear of entering the left atrium too high, using a PFO for left atrial access during LAA occlusion (LAAO) is generally discouraged. We report our single-center experience using a concomitant PFO for LAAO, thereby avoiding transseptal puncture. METHODS: LAAO was performed with local anesthesia and fluoroscopic guidance only (no echocardiography). The Amplatzer Cardiac Plug (ACP) was used in all patients. After LAAO, the PFO was closed at the same sitting, using an Amplatzer occluder through the ACP delivery sheath. Patients were discharged the same or the following day on dual antiplatelet therapy for 1-6 months, at which time a follow-up transesophageal echocardiogram (TEE) was performed. RESULTS: In 49 (96%) of 51 patients (35 males, age 70.9 ± 11.9 years), LAAO was successful using the PFO for left atrial access. In one patient, a long tunnel PFO precluded LAAO, which was performed via a more caudal transseptal puncture. In a second patient, a previously inserted ASD occluder precluded LAAO, which was abandoned because of pericardial bleeding. PFO closure was successful in all patients. Follow-up TEE was performed in 43 patients 138 ± 34 days after the procedure. It showed proper sitting of both devices in all patients. CONCLUSIONS: Using a PFO for LAAO had a high success rate and could be the default access in all patients with a PFO, potentially reducing procedural complications arising from transseptal puncture.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Forame Oval Patente/complicações , Dispositivo para Oclusão Septal , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Ecocardiografia Transesofagiana , Feminino , Fluoroscopia , Seguimentos , Forame Oval Patente/diagnóstico , Humanos , Masculino , Resultado do Tratamento
13.
Eur Heart J ; 34(25): 1894-905, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23487519

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) is an established treatment alternative to surgical aortic valve replacement in high-risk and inoperable patients and outcomes among patients with estimated low or intermediate risk remain to be determined. The aim of this study was to assess clinical outcomes among patients with estimated low or intermediate surgical risk undergoing TAVI. METHODS AND RESULTS: Between August 2007 and October 2011, 389 consecutive patients underwent TAVI and were categorized according to the Society of Thoracic Surgeons (STS) score into low (STS < 3%; n = 41, 10.5%), intermediate (STS ≥3% and ≤8%, n = 254, 65.3%), and high-risk (STS > 8%; n = 94, 24.2%) groups for the purpose of this study. Significant differences were found between the groups (low risk vs. intermediate risk vs. high risk) for age (78.2 ± 6.7 vs. 82.7 ± 5.7 vs. 83.7 ± 4.9, P < 0.001), body mass index (28.1 ± 6.1 vs. 26.5 ± 4.9 vs. 24.4 ± 4.6, P < 0.001), chronic renal failure (34 vs. 67 vs. 90%, P < 0.001), all-cause mortality at 30 days (2.4 vs. 3.9 vs. 14.9%, P = 0.001), and all-cause mortality at 1 year (10.1 vs. 16.1 vs. 34.5%, P = 0.0003). No differences were observed with regards to cerebrovascular accidents and myocardial infarction during 1-year follow-up. CONCLUSION: In contemporary practice, TAVI is not limited to inoperable or STS-defined high-risk patients and should be guided by the decision of an interdisciplinary Heart Team. Compared with patients at calculated high risk, well-selected patients with STS-defined intermediate or low risk appear to have favourable clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
14.
Eur Heart J ; 34(9): 684-92, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23008508

RESUMO

Aims This study aimed to assess functional course in elderly patients undergoing transcatheter aortic valve implantation (TAVI) and to find predictors of functional decline. Methods and results In this prospective cohort, functional course was assessed in patients ≥70 years using basic activities of daily living (BADL) before and 6 months after TAVI. Baseline EuroSCORE, STS score, and a frailty index (based on assessment of cognition, mobility, nutrition, instrumental and basic activities of daily living) were evaluated to predict functional decline (deterioration in BADL) using logistic regression models. Functional decline was observed in 22 (20.8%) of 106 surviving patients. EuroSCORE (OR per 10% increase 1.18, 95% CI: 0.83-1.68, P = 0.35) and STS score (OR per 5% increase 1.64, 95% CI: 0.87-3.09, P = 0.13) weakly predicted functional decline. In contrast, the frailty index strongly predicted functional decline in univariable (OR per 1 point increase 1.57, 95% CI: 1.20-2.05, P = 0.001) and bivariable analyses (OR: 1.56, 95% CI: 1.20-2.04, P = 0.001 controlled for EuroSCORE; OR: 1.53, 95% CI: 1.17-2.02, P = 0.002 controlled for STS score). Overall predictive performance was best for the frailty index [Nagelkerke's R(2) (NR(2)) 0.135] and low for the EuroSCORE (NR(2) 0.015) and STS score (NR(2) 0.034). In univariable analyses, all components of the frailty index contributed to the prediction of functional decline. Conclusion Over a 6-month period, functional status worsened only in a minority of patients surviving TAVI. The frailty index, but not established risk scores, was predictive of functional decline. Refinement of this index might help to identify patients who potentially benefit from additional geriatric interventions after TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/reabilitação , Próteses Valvulares Cardíacas , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Feminino , Idoso Fragilizado , Avaliação Geriátrica , Humanos , Masculino , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
15.
Eur Heart J ; 34(44): 3437-50, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24096324

RESUMO

AIMS: Our aim was to evaluate the invasive haemodynamic indices of high-risk symptomatic patients presenting with 'paradoxical' low-flow, low-gradient, severe aortic stenosis (AS) (PLF-LG) and low-flow, low-gradient severe AS (LEF-LG) and to compare clinical outcomes following transcatheter aortic valve implantation (TAVI) among these challenging AS subgroups. METHODS AND RESULTS: Of 534 symptomatic patients undergoing TAVI, 385 had a full pre-procedural right and left heart catheterization. A total of 208 patients had high-gradient severe AS [HGAS; mean gradient (MG) ≥40 mmHg], 85 had PLF-LG [MG ≤ 40 mmHg, indexed aortic valve area [iAVA] ≤0.6 cm(2) m(-2), stroke volume index ≤35 mL/m(2), ejection fraction (EF) ≥50%], and 61 had LEF-LG (MG ≤ 40 mmHg, iAVA ≤0.6 cm(2) m(-2), EF ≤40%). Compared with HGAS, PLF-LG and LEF-LG had higher systemic vascular resistances (HGAS: 1912 ± 654 vs. PLF-LG: 2006 ± 586 vs. LEF-LG: 2216 ± 765 dyne s m(-5), P = 0.007) but lower valvulo-arterial impedances (HGAS: 7.8 ± 2.7 vs. PLF-LG: 6.9 ± 1.9 vs. LEF-LG: 7.7 ± 2.5 mmHg mL(-1) m(-2), P = 0.027). At 30 days, no differences in cardiac death (6.5 vs. 4.9 vs. 6.6%, P = 0.90) or death (8.4 vs. 6.1 vs. 6.6%, P = 0.88) were observed among HGAS, PLF-LG, and LEF-LG groups, respectively. At 1 year, New York Heart Association functional improvement occurred in most surviving patients (HGAS: 69.2% vs. PLF-LG: 71.7% vs. LEF-LG: 89.3%, P = 0.09) and no significant differences in overall mortality were observed (17.6 vs. 20.5 vs. 24.5%, P = 0.67). Compared with HGAS, LEF-LG had a higher 1 year cardiac mortality (adjusted hazard ratio 2.45, 95% confidence interval 1.04-5.75, P = 0.04). CONCLUSION: TAVI in PLF-LG or LEF-LG patients is associated with overall mortality rates comparable with HGAS patients and all groups profit symptomatically to a similar extent.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Análise de Variância , Valva Aórtica , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Falha de Prótese , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda
16.
Front Cardiovasc Med ; 11: 1384222, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38911518

RESUMO

Introduction: Intravascular imaging, especially optical coherence tomography (OCT), has significantly improved percutaneous coronary intervention (PCI), yet its routine clinical application faces challenges. This case series introduces the Gentuity® High-Frequency Optical Coherence Tomography (HF-OCT), a novel device designed to enhance intracoronary imaging with a significantly faster pullback and smaller catheter size, potentially offering enhanced navigability in complex lesions. We aimed to assess the image quality of Gentuity® HF-OCT in complex vessel conditions, as well as presenting a case series to illustrate the application of the device in various clinical scenarios. Methods: In this case series, we included all patients who underwent intracoronary HF-OCT imaging at our center. The primary endpoint was image quality assessed by clear image length (CIL). Image quality was assessed in relation to (1) lesion severity assessed by minimum lumen area (MLA); (2) vessel size, differentiating between larger (diameter ≥ 4 mm) and smaller vessel segments; (3) pre- vs. post-PCI conditions, and (4) vessel tortuosity, categorized into none, moderate, and severe. Results: Twenty-four HF-OCT runs from 14 patients were included. No significant differences in CIL were observed across lesion severity terciles (p = 0.449), between small and large vessel segments [mean CIL% difference 1.3%; confidence interval (CI), -9.3 to 11.8; p = 0.802], and pre- vs. post-PCI conditions (mean CIL difference -3.9 mm; CI, -14.0 to 6.1; p = 0.373). Vessel tortuosity significantly impacted image quality, with clear reductions in CIL observed in cases of moderate (74.8; CI, 73.5 to 76.0; vs. 63.9; CI, 56.2 to 71.5; p = 0.043) and severe tortuosity (74.8; CI, 73.5 to 76.0; vs. 65.0; CI, 62.1 to 67.9; p = 0.002) compared to vessels with no tortuosity. Overall, the HF-OCT demonstrated excellent catheter deliverability and crossability, with very satisfactory image quality and no significant adverse events. Conclusion: The Gentuity® HF-OCT is a new OCT device capable of navigating both small- and large-diameter vessels, with similar image quality, but vessel tortuosity seems to have an impact on image quality. It appears to be as usable as conventional OCT for pre-PCI diagnosis and OCT-guided PCI, potentially bringing additional benefits in terms of deliverability, lesion crossover and ease of use in routine clinical practice.

17.
JACC Cardiovasc Interv ; 17(3): 405-418, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38355269

RESUMO

BACKGROUND: Studies comparing long-term outcomes between non-vitamin K antagonist (VKA) oral anticoagulant agents (direct oral anticoagulant agents [DOACs]) and VKA anticoagulant agents after transcatheter aortic valve replacement (TAVR) are scarce, with conflicting results. OBJECTIVES: The aim of this study was to examine the periprocedural, short-term, and long-term safety and effectiveness of DOACs vs VKAs in patients undergoing TAVR via femoral access with concomitant indications for oral anticoagulation. METHODS: Consecutive patients undergoing transfemoral TAVR in the prospective national SwissTAVI Registry between February 2011 and June 2021 were analyzed. Net clinical benefit (a composite of all-cause mortality, myocardial infarction, stroke, and life-threatening or major bleeding) and the primary safety endpoint (a composite of life-threatening and major bleeding) were compared between the VKA and DOAC groups at 30 days, 1 year, and 5 years after TAVR. RESULTS: After 1:1 propensity score matching, 1,454 patients were available for analysis in each group. There was no significant difference in the rate of the net clinical benefit and the safety endpoints between the groups as assessed at 30 days and 1 and 5 years post-TAVR between VKAs and DOACs. VKAs were associated with significantly higher rates of 1- year (HR: 1.28; 95% CI: 1.01-1.62) and 5-year (HR: 1.25; 95% CI: 1.11-1.40) all-cause mortality. Long-term risk for disabling stroke was significantly lower in the VKA group after excluding periprocedural events (HR: 0.64; 95% CI: 0.46-0.90). CONCLUSIONS: At 5 years after TAVR, VKAs are associated with a higher risk for all-cause mortality, a lower risk for disabling stroke, and a similar rate of life-threatening or major bleeding compared with DOACs. (SwissTAVI Registry; NCT01368250).


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrinolíticos , Vitamina K , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
18.
Circulation ; 125(9): 1110-21, 2012 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-22302840

RESUMO

BACKGROUND: Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES). METHODS AND RESULTS: We assessed the risk of stent thrombosis in a cohort of 12 339 patients with unrestricted use of drug-eluting stents (3819 SES, 4308 PES, 4212 EES). Results are incidence rates per 100 person-years after inverse probability of treatment weighting to adjust for group differences. During follow-up of up to 4 years, the overall incidence rate of definite stent thrombosis was lower with EES (1.4 per 100 person-years) compared with SES (2.9; hazard ratio, 0.41; 95% confidence interval, 0.27-0.62; P<0.0001) and PES (4.4; hazard ratio, 0.33; 95% confidence interval, 0.23-0.48; P<0.0001). The incidence rate per 100 person-years of early (0-30 days), late (31 days-1 year), and very late stent thrombosis amounted to 0.6, 0.1, and 0.6 among EES-treated patients; 1.0, 0.3, and 1.6 among SES-treated patients; and 1.3, 0.7, and 2.4 among PES-treated patients. Differences in favor of EES were most pronounced beyond 1 year, with a hazard ratio of 0.33 (EES versus SES; P=0.006) and 0.34 (EES versus PES; P<0.0001). There was a lower risk of cardiac death or myocardial with EES compared with PES (hazard ratio, 0.65; 95% confidence interval, 0.56-0.75; P<0.0001), which was directly related to the lower risk of stent thrombosis-associated events (EES versus PES: hazard ratio, 0.36; 95% confidence interval, 0.23-0.57). CONCLUSION: Current treatment with EES is associated with a lower risk of very late stent thrombosis compared with early-generation drug-eluting stents.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/estatística & dados numéricos , Idoso , Angioplastia Coronária com Balão/estatística & dados numéricos , Estudos de Coortes , Everolimo , Feminino , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Incidência , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Readmissão do Paciente/estatística & dados numéricos , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Análise de Sobrevida , Fatores de Tempo , Moduladores de Tubulina/administração & dosagem
19.
Catheter Cardiovasc Interv ; 82(7): E919-21, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22581741

RESUMO

Previous reports prove the safety and efficacy of cardiac pacing employing a guidewire in the left ventricle as unipolar pacing electrode. We describe the use of left ventricular guidewire pacing as an alternative to conventional transvenous temporary right ventricular pacing in the context of transcatheter aortic valve implantation.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/métodos , Marca-Passo Artificial , Função Ventricular Esquerda , Idoso , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Desenho de Equipamento , Humanos , Masculino , Índice de Gravidade de Doença , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 82(2): 283-9, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23412815

RESUMO

OBJECTIVES: To report a 10-year single center experience with Amplatzer devices for left atrial appendage (LAA) occlusion. BACKGROUND: Intermediate-term outcome data following LAA occlusion are scarce. METHODS: Short- and intermediate-term outcomes of patients who underwent LAA occlusion were assessed. All procedures were performed under local aesthesia without transesophageal echocardiography. Patients were discharged on acetylsalicylic acid and clopidogrel for 1-6 months. RESULTS: LAA occlusion was attempted in 152 patients (105 males, age 72 ± 10 years, CHA2 DS2 -Vasc-score 3.4 ± 1.7, HAS-BLED-score 2.4 ± 1.2). Nondedicated devices were used in 32 patients (21%, ND group) and dedicated Amplatzer Cardiac Plugs were used in 120 patients (79%, ACP group). A patent foramen ovale or atrial septal defect was used for left atrial access and closed at the end of LAA occlusion in 40 patients. The short-term safety endpoints (procedural complications, bleeds) occurred in 15 (9.8%) and the efficacy endpoints (death, stroke, systemic embolization) in 0 patients. Device embolization occurred more frequently in the ND as compared to the ACP group (5 patients or 12% vs. 2 patients or 2%). Mean intermediate-term follow up of the study population was 32 months (range 1-120). Late deaths occurred in 15 patients (5 cardiovascular, 7 noncardiac, 3 unexplained). Neurologic events occurred in 2, peripheral embolism in 1, and major bleeding in 4 patients. The composite efficacy and safety endpoint occurred in 7% and 12% of patients. CONCLUSION: LAA closure may be a good alternative to oral anticoagulation. This hypothesis needs to be tested in a randomized clinical trial to ensure that all potential biases of this observational study are accounted for.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Anestesia Local , Aspirina/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Clopidogrel , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Radiografia Intervencionista , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Suíça , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Fatores de Tempo , Resultado do Tratamento