Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Transfusion ; 60(7): 1364-1372, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32430950

RESUMO

BACKGROUND: Point-of-issue tests, such as the Verax Pan Genera Detection (PGD) test, can be used to mitigate the occurrence of septic reactions. Little is known about how widespread the adoption of the PGD test is across US hospitals. STUDY DESIGN/METHODS: The Red Cross hemovigilance database was used to determine the numbers of PGD-positive test results between 2013 and 2018. An examination of the impact of a reactive PGD test on product availability was performed for 2018. RESULTS: The number of reported cases doubled, rising from approximately 50 to 100 per year between 2013 and 2018. A total of 475 initially reactive PGD tests during the entire study period were reported, and 7 (1.5%) of these were determined to be true positives. Hospitals surveyed reported testing platelet units once, with no repeat testing if the unit was PGD reactive. Evaluation of the reported PGD reactive cases for apheresis platelets for 2018 (n = 93) resulted in an estimated cost to the blood center of $87,000, which included the labor and material costs of working up the cases and the estimated value of the lost 64 units and co-components. In addition, there was a loss of the opportunity to collect over 85 apheresis platelets during the time the implicated donor was temporarily deferred. CONCLUSIONS: The number of hospital reports of reactive PGD tests has shown modest growth in the past 5 years. The number of initially reactive PGD tests that were confirmed was minimal. Blood centers can incur cost and platelet inventory loss from initially false-positive test results.


Assuntos
Infecções Bacterianas/sangue , Infecções Bacterianas/microbiologia , Técnicas de Tipagem Bacteriana , Plaquetas/microbiologia , Segurança do Sangue , Plaquetoferese , Humanos , Cruz Vermelha
2.
J Pediatr ; 181: 302-305, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27852457

RESUMO

Alloantibody formation at less than 4 months of age is rare. Most antibodies identified in these patients are maternally derived. Anti-PP1Pk was detected in an 11-week-old infant that was not maternally derived. A multidisciplinary team approach led to appropriate testing, diagnosis, and transfusion management in this critically ill infant.


Assuntos
Eritrócitos/imunologia , Isoanticorpos/sangue , Transfusão de Sangue , Feminino , Humanos , Lactente
3.
Transfusion ; 60(9): 2158-2159, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-33460143
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA