1.
Eur J Nucl Med Mol Imaging ; 49(11): 3750-3760, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35593925

RESUMO

PURPOSE: We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. METHODS: One hundred ninety-five patients referred for [18F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original "PET90" (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, "PET45AI and PET45". Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SULmax and SULpeak), metabolic volumes (MV), and liver SULmean were measured, including both standard and EARL1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CVliv) were calculated. RESULTS: PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL1 SULpeak was not significantly different between both PET (P = 0.09). Lesion standard SULpeak, standard and EARL1 SULmax, LLR and CVliv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SULmean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SULmean (ICC ≥ 0.87). CONCLUSION: AI allows [18F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Inteligência Artificial , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
2.
Radiology ; 300(1): E301-E307, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33724061

RESUMO

Background Early reports show the unequal effect the COVID-19 pandemic might have on men versus women engaged in medical research. Purpose To investigate whether the COVID-19 pandemic has had an impact on scientific publishing by female physicians in medical imaging. Materials and Methods The authors conducted a descriptive bibliometric analysis of the gender of the first and last authors of manuscripts submitted to the top 50 medical imaging journals from March to May 2020 (n = 2480) compared with the same period of the year in 2018 (n = 2238) and 2019 (n = 2355). Manuscript title, date of submission, first and last names of the first and last authors, journal impact factor, and author country of provenance were recorded. The Gender-API software was used to determine author gender. Statistical analysis comprised χ2 tests and multivariable logistic regression. Results Percentages of women listed as first and last authors were 31.6% (1172 of 3711 articles) and 19.3% (717 of 3711 articles), respectively, in 2018-2019 versus 32.3% (725 of 2248 articles) and 20.7% (465 of 2248 articles) in 2020 (P = .61 and P = .21, respectively). For COVID-19-related articles, 35.2% (89 of 253 articles) of first authors and 20.6% (52 of 253 articles) of last authors were women. No associations were found between first- and last-author gender, year of publication, and region of provenance. First and last authorship of high-ranking articles was not in favor of North American women whatever the year (odds ratio [OR], 0.79 [P = .05] and 0.72 [P = .02], respectively). Higher rates of female last authorship of high-ranking articles were observed in Europe (P = .003) and of female first authorship of low-ranking publications in Asia in 2020 (OR, 1.38; 95% CI: 0.98, 1.92; P = .06). Female first and last authorship of COVID-19-related articles was overrepresented for lowest-rank publications (P = .02 and P = .01, respectively). Conclusion One in three first authors and one in five last authors were women in 2018-2019 and 2020, respectively. Although the first 2020 lockdown did not diminish the quantity of women-authored publications, the impact on the quality was variable. ©RSNA, 2021 See also the editorial by Robbins and Khosa in this issue.


Assuntos
Autoria , Bibliometria , Pesquisa Biomédica/estatística & dados numéricos , COVID-19 , Publicações Periódicas como Assunto/estatística & dados numéricos , Sexismo/estatística & dados numéricos , Feminino , Humanos , Masculino , Pandemias , Quarentena , SARS-CoV-2
3.
EJNMMI Res ; 14(1): 72, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39126532

RESUMO

BACKGROUND: [18F]FDG PET denoising by SubtlePET™ using deep learning artificial intelligence (AI) was previously found to induce slight modifications in lesion and reference organs' quantification and in lesion detection. As a next step, we aimed to evaluate its clinical impact on [18F]FDG PET solid tumour treatment response assessments, while comparing "standard PET" to "AI denoised half-duration PET" ("AI PET") during follow-up. RESULTS: 110 patients referred for baseline and follow-up standard digital [18F]FDG PET/CT were prospectively included. "Standard" EORTC and, if applicable, PERCIST response classifications by 2 readers between baseline standard PET1 and follow-up standard PET2 as a "gold standard" were compared to "mixed" classifications between standard PET1 and AI PET2 (group 1; n = 64), or between AI PET1 and standard PET2 (group 2; n = 46). Separate classifications were established using either standardized uptake values from ultra-high definition PET with or without AI denoising (simplified to "UHD") or EANM research limited v2 (EARL2)-compliant values (by Gaussian filtering in standard PET and using the same filter in AI PET). Overall, pooling both study groups, in 11/110 (10%) patients at least one EORTCUHD or EARL2 or PERCISTUHD or EARL2 mixed vs. standard classification was discordant, with 369/397 (93%) concordant classifications, unweighted Cohen's kappa = 0.86 (95% CI: 0.78-0.94). These modified mixed vs. standard classifications could have impacted management in 2% of patients. CONCLUSIONS: Although comparing similar PET images is preferable for therapy response assessment, the comparison between a standard [18F]FDG PET and an AI denoised half-duration PET is feasible and seems clinically satisfactory.

4.
Front Med (Lausanne) ; 10: 1137514, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36993807

RESUMO

Introduction: The yield per elution of a 68Ge/68Ga generator decreases during its lifespan. This affects the number of patients injected per elution or the injected dose per patient, thereby negatively affecting the cost of examinations and the quality of PET images due to increased image noise. We aimed to investigate whether AI-based PET denoising can offset this decrease in image quality parameters. Methods: All patients addressed to our PET unit for a 68Ga-DOTATOC PET/CT from April 2020 to February 2021 were enrolled. Forty-four patients underwent their PET scans according to Protocol_FixedDose (150 MBq) and 32 according to Protocol_WeightDose (1.5 MBq/kg). Protocol_WeightDose examinations were processed using the Subtle PET software (Protocol_WeightDoseAI). Liver and vascular SUV mean were recorded as well as SUVmax, SUVmean and metabolic tumour volume (MTV) of the most intense tumoural lesion and its background SUVmean. Liver and vascular coefficients of variation (CV), tumour-to-background and tumour-to-liver ratios were calculated. Results: The mean injected dose of 2.1 (0.4) MBq/kg per patient was significantly higher in the Protocol_FixedDose group as compared to 1.5 (0.1) MBq/kg for the Protocol_WeightDose group. Protocol_WeightDose led to noisier images than Protocol_FixedDose with higher CVs for liver (15.57% ± 4.32 vs. 13.04% ± 3.51, p = 0.018) and blood-pool (28.67% ± 8.65 vs. 22.25% ± 10.37, p = 0.0003). Protocol_WeightDoseAI led to less noisy images than Protocol_WeightDose with lower liver CVs (11.42% ± 3.05 vs. 15.57% ± 4.32, p < 0.0001) and vascular CVs (16.62% ± 6.40 vs. 28.67% ± 8.65, p < 0.0001). Tumour-to-background and tumour-to-liver ratios were lower for protocol_WeightDoseAI: 6.78 ± 3.49 vs. 7.57 ± 4.73 (p = 0.01) and 5.96 ± 5.43 vs. 6.77 ± 6.19 (p < 0.0001), respectively. MTVs were higher after denoising whereas tumour SUVmax were lower: the mean% differences in MTV and SUVmax were + 11.14% (95% CI = 4.84-17.43) and -3.92% (95% CI = -6.25 to -1.59). Conclusion: The degradation of PET image quality due to a reduction in injected dose at the end of the 68Ge/68Ga generator lifespan can be effectively counterbalanced by using AI-based PET denoising.

5.
Diagnostics (Basel) ; 13(9)2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37175017

RESUMO

Given the constant pressure to increase patient throughput while respecting radiation protection, global body PET image quality (IQ) is not satisfactory in all patients. We first studied the association between IQ and other variables, in particular body habitus, on a digital PET/CT. Second, to improve and homogenize IQ, we evaluated a deep learning PET denoising solution (Subtle PETTM) using convolutional neural networks. We analysed retrospectively in 113 patients visual IQ (by a 5-point Likert score in two readers) and semi-quantitative IQ (by the coefficient of variation in the liver, CVliv) as well as lesion detection and quantification in native and denoised PET. In native PET, visual and semi-quantitative IQ were lower in patients with larger body habitus (p < 0.0001 for both) and in men vs. women (p ≤ 0.03 for CVliv). After PET denoising, visual IQ scores increased and became more homogeneous between patients (4.8 ± 0.3 in denoised vs. 3.6 ± 0.6 in native PET; p < 0.0001). CVliv were lower in denoised PET than in native PET, 6.9 ± 0.9% vs. 12.2 ± 1.6%; p < 0.0001. The slope calculated by linear regression of CVliv according to weight was significantly lower in denoised than in native PET (p = 0.0002), demonstrating more uniform CVliv. Lesion concordance rate between both PET series was 369/371 (99.5%), with two lesions exclusively detected in native PET. SUVmax and SUVpeak of up to the five most intense native PET lesions per patient were lower in denoised PET (p < 0.001), with an average relative bias of -7.7% and -2.8%, respectively. DL-based PET denoising by Subtle PETTM allowed [18F]FDG PET global image quality to be improved and homogenized, while maintaining satisfactory lesion detection and quantification. DL-based denoising may render body habitus adaptive PET protocols unnecessary, and pave the way for the improvement and homogenization of PET modalities.

6.
Diagnostics (Basel) ; 12(10)2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36292136

RESUMO

This study aimed to investigate if combining clinical characteristics with pre-therapeutic 18 F-fluorodeoxyglucose (18 F-FDG) positron emission tomography (PET) radiomics could predict the presence of molecular alteration(s) in key molecular targets in lung adenocarcinoma. This non-interventional monocentric study included patients with newly diagnosed lung adenocarcinoma referred for baseline PET who had tumour molecular analyses. The data were randomly split into training and test datasets. LASSO regression with 100-fold cross-validation was performed, including sex, age, smoking history, AJCC cancer stage and 31 PET variables. In total, 109 patients were analysed, and it was found that 63 (57.8%) patients had at least one molecular alteration. Using the training dataset (n = 87), the model included 10 variables, namely age, sex, smoking history, AJCC stage, excessKustosis_HISTO, sphericity_SHAPE, variance_GLCM, correlation_GLCM, LZE_GLZLM, and GLNU_GLZLM. The ROC analysis for molecular alteration prediction using this model found an AUC equal to 0.866 (p < 0.0001). A cut-off value set to 0.48 led to a sensitivity of 90.6% and a positive likelihood ratio (LR+) value equal to 2.4. After application of this cut-off value in the unseen test dataset of patients (n = 22), the test presented a sensitivity equal to 90.0% and an LR+ value of 1.35. A clinico-metabolic 18 F-FDG PET phenotype allows the detection of key molecular target alterations with high sensitivity and negative predictive value. Hence, it opens the way to the selection of patients for molecular analysis.

7.
Front Oncol ; 11: 692973, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34504782

RESUMO

BACKGROUND: With a constantly increasing number of diagnostic images performed each year, Artificial Intelligence (AI) denoising methods offer an opportunity to respond to the growing demand. However, it may affect information in the image in an unknown manner. This study quantifies the effect of AI-based denoising on FDG PET textural information in comparison to a convolution with a standard gaussian postfilter (EARL1). METHODS: The study was carried out on 113 patients who underwent a digital FDG PET/CT (VEREOS, Philips Healthcare). 101 FDG avid lesions were segmented semi-automatically by a nuclear medicine physician. VOIs in the liver and lung as reference organs were contoured. PET textural features were extracted with pyradiomics. Texture features from AI denoised and EARL1 versus original PET images were compared with a Concordance Correlation Coefficient (CCC). Features with CCC values ≥ 0.85 threshold were considered concordant. Scatter plots of variable pairs with R2 coefficients of the more relevant features were computed. A Wilcoxon signed rank test to compare the absolute values between AI denoised and original images was performed. RESULTS: The ratio of concordant features was 90/104 (86.5%) in AI denoised versus 46/104 (44.2%) with EARL1 denoising. In the reference organs, the concordant ratio for AI and EARL1 denoised images was low, respectively 12/104 (11.5%) and 7/104 (6.7%) in the liver, 26/104 (25%) and 24/104 (23.1%) in the lung. SUVpeak was stable after the application of both algorithms in comparison to SUVmax. Scatter plots of variable pairs showed that AI filtering affected more lower versus high intensity regions unlike EARL1 gaussian post filters, affecting both in a similar way. In lesions, the majority of texture features 79/100 (79%) were significantly (p<0.05) different between AI denoised and original PET images. CONCLUSIONS: Applying an AI-based denoising on FDG PET images maintains most of the lesion's texture information in contrast to EARL1-compatible Gaussian filter. Predictive features of a trained model could be thus the same, however with an adapted threshold. Artificial intelligence based denoising in PET is a very promising approach as it adapts the denoising in function of the tissue type, preserving information where it should.

8.
Front Oncol ; 11: 714514, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34504791

RESUMO

Brain metastases (BM) are frequently detected during the follow-up of patients with malignant tumors, particularly in those with advanced disease. Despite a major progress in systemic anti-cancer treatments, the average overall survival of these patients remains limited (6 months from diagnosis). Also, cognitive decline is regularly reported especially in patients treated with whole brain external beam radiotherapy (WBRT), due to the absorbed radiation dose in healthy brain tissue. New targeted therapies, for an earlier and/or more specific treatment of the tumor and its microenvironment, are needed. Radioimmunotherapy (RIT), a combination of a radionuclide to a specific antibody, appears to be a promising tool. Inflammation, which is involved in multiple steps, including the early phase, of BM development is attractive as a relevant target for RIT. This review will focus on the (1) early biomarkers of inflammation in BM pertinent for RIT, (2) state of the art studies on RIT for BM, and (3) the importance of dosimetry to RIT in BM. These two last points will be addressed in comparison to the conventional EBRT treatment, particularly with respect to the balance between tumor control and healthy tissue complications. Finally, because new diagnostic imaging techniques show a potential for the detection of BM at an early stage of the disease, we focus particularly on this therapeutic window.

9.
J Nucl Med Technol ; 47(3): 227-232, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31019044

RESUMO

Spirometric gating devices (SGDs) can measure the respiratory signal with high temporal resolution and accuracy. The primary objective of this study was to assess the feasibility and tolerance of a gated lung PET/CT acquisition using an SGD. The secondary objective was to compare the technical quality, accuracy, and interoperability of the SGD with that of a standard respiratory gating device, Real-Time Position Management (RPM), based on measurement of vertical thoracoabdominal displacement. Methods: A prospective phase I monocentric clinical study was performed on patients undergoing 18F-FDG PET/CT for assessment of a solitary lung nodule, staging of lung malignancy, or planning of radiotherapy. After whole-body PET/CT, a centered gated acquisition of both PET and CT was simultaneously obtained with the SGD and RPM during normal breathing. Results: Of the 46 patients who were included, 6 were prematurely excluded (1 because of hyperglycemia and 5 because of distant metastases revealed by whole-body PET/CT, leading to an unjustified extra gated acquisition). No serious adverse events were observed. Of the 40 remaining patients, the gated acquisition was prematurely stopped in 1 patient because of mask discomfort (2.5%; confidence interval [CI], 0.1%-13.2%). This event was considered patient tolerance failure. The SGD generated accurately gated PET/CT images, with more than 95% of the breathing cycle detected and high temporal resolution, in 34 of the 39 patients (87.2%; 95% CI, 60.0%-100.0%) and failed to generate a biologic tumor volume in 1 of 21 patients with increased 18F-FDG uptake (4.8%; 95% CI, 0.1%-26.5%). The quality and accuracy of respiratory signal detection and synchronization were significantly better than those obtained with RPM (P < 0.05). Conclusion: This trial supports the use of an SGD for gated lung PET/CT because of its high patient tolerance and accuracy. Although this technique seems to technically outperform RPM for gated PET/CT, further assessment of its superiority and the clinical benefit is warranted. We believe that this technique could be used as a gold standard to develop innovative approaches to eliminate respiration-induced blurring artifacts.


Assuntos
Fluordesoxiglucose F18 , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Técnicas de Imagem de Sincronização Respiratória/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
10.
Clin Nucl Med ; 43(5): 333-334, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29485438

RESUMO

Vemurafenib improves the management of advanced melanoma due to selective inhibition of the mutated BRAF V600E kinase. FDG-PET-CT is a tool for the evaluation of the biologic impact of inhibiting mutant BRAF. With vemurafenib at day 15, all the patients had at least partial metabolic response. Reductions in uptake correlate with longer progression free survival. In this case, incomplete information provided by the patient led to the performance of his third PET 85 hours after the introduction of vemurafenib. This early case of complete metabolic response suggests that FDG-PET-CT is a useful marker of early biologic response to vemurafenib.


Assuntos
Antineoplásicos/uso terapêutico , Indóis/uso terapêutico , Melanoma/tratamento farmacológico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Inibidores de Proteínas Quinases/uso terapêutico , Sulfonamidas/uso terapêutico , Intervalo Livre de Doença , Fluordesoxiglucose F18 , Humanos , Melanoma/diagnóstico por imagem , Compostos Radiofarmacêuticos , Vemurafenib
11.
Clin Nucl Med ; 43(8): 604-605, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29916915

RESUMO

A 37-year-old woman with pheochromocytoma underwent presurgical FDG PET/CT. Despite her usual antiadrenergic medication consisting in 25 mg of carvedilol, PET/CT demonstrated intense and widespread FDG uptake in brown adipose tissue (BAT). No BAT FDG uptake was detectable on a repeated examination after specific preparation consisting in 40 mg propranolol and 5 mg diazepam. We therefore recommend this propranolol-diazepam preparation in patients with pheochromocytoma referred for PET/CT. Carvedilol-classically prescribed to alleviate effects of adrenergic overstimulation-seems ineffective on BAT. This observation questions the benefit of carvedilol to reduce ß3-adrenoreceptor-mediated effects, not only in BAT, but also in other tissues.


Assuntos
Tecido Adiposo Marrom/efeitos dos fármacos , Neoplasias das Glândulas Suprarrenais/tratamento farmacológico , Neoplasias das Glândulas Suprarrenais/patologia , Antagonistas Adrenérgicos beta/farmacologia , Carbazóis/farmacologia , Feocromocitoma/tratamento farmacológico , Feocromocitoma/patologia , Propanolaminas/farmacologia , Tecido Adiposo Marrom/patologia , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Carbazóis/uso terapêutico , Carvedilol , Feminino , Fluordesoxiglucose F18 , Humanos , Feocromocitoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Propanolaminas/uso terapêutico , Falha de Tratamento
12.
Clin Imaging ; 45: 1-7, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28551486

RESUMO

18FDG PET-CT is useful for early and differential diagnosis of dementia. ASL-MRI seems an attractive alternative. Visual agreement was calculated in 21 brain regions bilaterally in 9/11 patients with suspected early-stage dementia, excluding 2 patients due to ASL-MRI motion artefacts. Overall gross agreement was almost perfect and identical between and within modalities (κ=0.85-0.86, p<0.05). Intermodality regional agreement was variable, moderate (κ=0,56 in posterior cingulate) to perfect (including in precuneus), not different from intramodality agreement. Diagnostic accuracy was 5/9 (56%) for ASL-MRI and 7/9 (78%) for FDG PETCT. (p=0.31). Clinical experience and optimisation may further improve ASL-MRI's performance.


Assuntos
Encéfalo/diagnóstico por imagem , Demência/diagnóstico , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Artefatos , Circulação Cerebrovascular , Demência/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Marcadores de Spin
14.
Clin Nucl Med ; 41(5): e257-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26859202

RESUMO

This 65 year-old woman, 1 month postoperative after maxillary sinus carcinoma (pT4N0cM0) excision and reconstruction, presented with significant left facial clear fluid wound leakage. A salivary or cerebrospinal leakage was suspected. Fluid analysis, CT, and MRI were noncontributory. Dynamic salivary scintigraphy with SPECT-CT allowed for the detection and localization of the leakage from the left parotid gland. Radioactive dose rate of the wound bandage was 50 µSv/h compared with 0.05 µSv/h for background and confirmed the diagnosis. Left total parotidectomy resulted in resolution.


Assuntos
Glândula Parótida/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Glândulas Salivares/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Carcinoma/cirurgia , Feminino , Humanos , Neoplasias Maxilares/cirurgia , Pessoa de Meia-Idade
15.
Med Phys ; 41(11): 112503, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25370662

RESUMO

PURPOSE: Respiratory motion is a source of artifacts that reduce image quality in PET. Four dimensional (4D) PET/CT is one approach to overcome this problem. Existing techniques to limiting the effects of respiratory motions are based on prospective phase binning which requires a long acquisition duration (15-25 min). This time is uncomfortable for the patients and limits the clinical exploitation of 4D PET/CT. In this work, the authors evaluated an existing method and an alternative retrospective binning method to reduce the acquisition duration of 4D PET/CT. METHODS: The authors studied an existing mixed-amplitude binning (MAB) method and an alternative binning method by mixed-phases (MPhB). Before implementing MPhB, they analyzed the regularity of the breathing patterns in patients. They studied the breathing signal drift and missing CT slices that could be challenging for implementing MAB. They compared the performance of MAB and MPhB with current binning methods to measure the maximum uptake, internal volume, and maximal range of tumor motion. RESULTS: MPhB can be implemented depending on an optimal phase (in average, the exhalation peak phase -4.1% of the entire breathing cycle duration). Signal drift of patients was in average 35% relative to the breathing amplitude. Even after correcting this drift, MAB was feasible in 4D CT for only 64% of patients. No significant differences appeared between the different binning methods to measure the maximum uptake, internal volume, and maximal range of tumor motion. The authors also determined the inaccuracies of MAB and MPhB to measure the maximum amplitude of tumor motion with three bins (less than 3 mm for movement inferior to 12 mm, up to 6.4 mm for a 21 mm movement). CONCLUSIONS: The authors proposed an alternative binning method by mixed-phase binning that halves the acquisition duration of 4D PET/CT. Mixed-amplitude binning was challenging because of signal drift and missing CT slices. They showed that more than three bins were necessary for a more accurate measurement of the maximum amplitude of the tumor motion. However, the current 4D-CT technology limits the increase of the number of bins in 4D PET/CT because of missing CT slices. One can reconstruct 4D PET images with more bins but without attenuation/scatter correction.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento , Interpretação de Imagem Radiográfica Assistida por Computador , Respiração , Software