Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 32(1): 561-571, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34215940

RESUMO

OBJECTIVES: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. METHODS: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. RESULTS: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0-3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0-3) (p < .001). A cutoff value of - 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. CONCLUSIONS: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines. KEY POINTS: • In the setting of spinal trauma, dual-energy CT (DECT) is highly accurate in the evaluation of acute vertebral fractures and bone marrow edema presence and extent. • MRI provides moderate sensitivity and lower diagnostic confidence for the depiction of acute fracture lines, when compared to DECT, which might result in potentially inaccurate and underestimated severity assessment of injuries in certain cases when no fracture lines are visible on MRI. • DECT may represent a valid imaging alternative to MRI in specific settings of acute spinal trauma and in follow-up examinations, especially in elderly or unstable patients and in cases of subtle or complex orientated fracture lines.


Assuntos
Fraturas da Coluna Vertebral , Idoso , Medula Óssea , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
2.
Eur Radiol ; 32(5): 3076-3084, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34713330

RESUMO

OBJECTIVES: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. METHODS: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19-103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. RESULTS: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091-0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867-0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. CONCLUSIONS: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. KEY POINTS: •Dual-energy CT-derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).


Assuntos
Osteoporose , Fraturas por Osteoporose , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Osteoporose/epidemiologia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
3.
Eur Radiol ; 32(4): 2168-2177, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820684

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. METHODS: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. RESULTS: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). CONCLUSIONS: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. KEY POINTS: • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


Assuntos
Deslocamento do Disco Intervertebral , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Medula Óssea , Edema , Feminino , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
4.
Acta Radiol ; 63(3): 328-335, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33657848

RESUMO

BACKGROUND: High-resolution computed tomography (HRCT) is essential in narrowing the possible differential diagnoses of diffuse and interstitial lung diseases. PURPOSE: To investigate the value of a novel computer-based decision support system (CDSS) for facilitating diagnosis of diffuse lung diseases at HRCT. MATERIAL AND METHODS: A CDSS was developed that includes about 100 different illustrations of the most common HRCT signs and patterns and describes the corresponding pathologies in detail. The logical set-up of the software facilitates a structured evaluation. By selecting one or more CT patterns, the program generates a ranked list of the most likely differential diagnoses. Three independent and blinded radiology residents initially evaluated 40 cases with different lung diseases alone; after at least 12 weeks, observers re-evaluated all cases using the CDSS. RESULTS: In 40 patients, a total of 113 HRCT patterns were evaluated. The percentage of correctly classified patterns was higher with CDSS (96.8%) compared to assessment without CDSS (90.3%; P < 0.01). Moreover, the percentage of correct diagnosis (81.7% vs. 64.2%) and differential diagnoses (89.2% vs. 38.3%) were superior with CDSS compared to evaluation without CDSS (both P < 0.01). CONCLUSION: Addition of a CDSS using a structured approach providing explanations of typical HRCT patterns and graphical illustrations significantly improved the performance of trainees in characterizing and correctly identifying diffuse lung diseases.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
5.
Eur Radiol ; 31(7): 4428-4437, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409799

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded dual-energy CT virtual non-calcium (VNCa) reconstructions for the assessment of bone marrow edema (BME) of the scaphoid in patients with acute wrist trauma. METHODS: Our retrospective study included data from 141 patients (67 women, 74 men; mean age 43 years, range 19-80 years) with acute wrist trauma who had undergone third-generation dual-source dual-energy CT and 3-T MRI within 7 days. Eight weeks after assessment of conventional grayscale dual-energy CT scans for the presence of fractures, corresponding color-coded VNCa reconstructions were independently analyzed by the same six radiologists for the presence of BME. CT numbers on VNCa reconstructions were evaluated by a seventh radiologist. Consensus reading of MRI series by two additional radiologists served as the reference standard. RESULTS: MRI depicted 103 scaphoideal zones with BME in 76 patients. On qualitative analysis, VNCa images yielded high overall sensitivity (580/618 [94%]), specificity (1880/1920 [98%]), and accuracy (2460/2538 [97%]) for assessing BME as compared with MRI as reference standard. The interobserver agreement was excellent (κ = 0.98). CT numbers derived from VNCa images were significantly different in zones with and without edema (p < 0.001). A cutoff value of - 46 Hounsfield units provided a sensitivity of 91% and specificity of 97% for differentiating edematous scaphoid lesions. Receiver operating characteristic curve analysis revealed an overall area under the curve of 0.98. CONCLUSIONS: Qualitative and quantitative analyses showed excellent diagnostic accuracy of color-coded VNCa reconstructions for assessing traumatic BME of the scaphoid compared to MRI. KEY POINTS: • Color-coded virtual non-calcium (VNCa) reconstructions yield excellent diagnostic accuracy in assessing bone marrow edema of the scaphoid. • VNCa imaging enables detection of non-displaced fractures that are occult on standard grayscale CT. • Diagnostic confidence is comparable between VNCa imaging and MRI.


Assuntos
Medula Óssea , Osso Escafoide , Adulto , Idoso , Idoso de 80 Anos ou mais , Medula Óssea/diagnóstico por imagem , Cálcio , Edema/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osso Escafoide/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Eur Radiol ; 31(12): 9221-9231, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34076743

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. METHODS: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. RESULTS: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89-0.96] vs 485/665 [73%; 95% CI, 0.67-0.80]), specificity (4775/4990 [96%; 95% CI, 0.90-0.98] vs 4066/4990 [82%; 95% CI, 0.79-0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93-0.98] vs 4551/5655 [81%; 95% CI, 0.74-0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). CONCLUSIONS: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT. KEY POINTS: • Color-coded VNCa reconstructions derived from third-generation dual-source dual-energy CT yielded significantly higher diagnostic accuracy for the assessment of thoracic disk herniation and spinal nerve root impingement compared to standard grayscale CT. • VNCa imaging provided higher diagnostic confidence and image quality at lower noise levels compared to standard grayscale CT. • Color-coded VNCa images may potentially serve as a viable imaging alternative to MRI under circumstances where MRI is unavailable or contraindicated.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Idoso , Medula Óssea , Edema , Feminino , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Eur Radiol ; 30(1): 141-150, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31350586

RESUMO

OBJECTIVES: To evaluate the diagnostic accuracy of dual-energy computed tomography (CT) virtual non-calcium (VNCa) reconstructions for the depiction of traumatic knee bone marrow edema. METHODS: Fifty-seven patients (mean age, 50 years; range, 20-82 years) with acute knee trauma further divided into 30 women and 27 men, who had undergone third-generation dual-source dual-energy CT and 3-T magnetic resonance imaging (MRI) within 7 days between January 2017 and May 2018, were retrospectively analyzed. Six radiologists, blinded to clinical and MRI information, independently analyzed conventional grayscale dual-energy CT series for fractures; after 8 weeks, readers evaluated color-coded VNCa reconstructions for the presence of bone marrow edema in six femoral and six tibial regions. Quantitative analysis of CT numbers on VNCa reconstructions was performed by a seventh radiologist. Two additional radiologists, blinded to clinical and CT information, analyzed MRI series in consensus to define the reference standard. Sensitivity, specificity, and the area under the curve (AUC) were the primary metrics of diagnostic accuracy. RESULTS: MRI revealed 197 areas with bone marrow edema (91/342 femoral, 106/342 tibial). In the qualitative analysis, VNCa showed high overall sensitivity (1108/1182 [94%]) and specificity (2789/2922 [95%]) for depicting bone marrow edema. The AUC was 0.96 (femur) and 0.97 (tibia). A cutoff value of - 51 Hounsfield units (HU) provided high sensitivity (102/106 [96%]) and specificity (229/236 [97%]) for differentiating tibial bone marrow edema. CONCLUSIONS: In both quantitative and qualitative analyses, dual-energy CT VNCa reconstructions yielded excellent diagnostic accuracy for depicting traumatic knee bone marrow edema compared with MRI. KEY POINTS: • Dual-energy CT (DECT) virtual non-calcium (VNCa) reconstructions are highly accurate in depicting bone marrow edema of the femur and tibia. • Diagnostic confidence, image noise, and image quality were rated as equivalent in VNCa reconstructions and MRI (magnetic resonance imaging) series. • VNCa images may serve as an alternative imaging approach to MRI.


Assuntos
Doenças da Medula Óssea/patologia , Edema/patologia , Fraturas Ósseas/patologia , Traumatismos do Joelho , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Cálcio , Feminino , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/patologia , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tíbia/patologia , Adulto Jovem
8.
Radiology ; 290(2): 446-455, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30615548

RESUMO

Purpose To assess the diagnostic performance of dual-energy CT with reconstruction of virtual noncalcium (VNCa) images for the detection of lumbar disk herniation compared with standard CT image reconstruction. Materials and Methods For this retrospective study, 41 patients (243 intervertebral disks; overall mean age, 68 years; 24 women [mean age, 68 years] and 17 men [mean age, 68 years]) underwent clinically indicated third-generation, dual-source, dual-energy CT and 3.0-T MRI within 2 weeks between March 2017 and January 2018. Six radiologists, blinded to clinical and MRI information, independently evaluated conventional gray-scale dual-energy CT series for the presence and degree of lumbar disk herniation and spinal nerve root impingement. After 8 weeks, readers reevaluated examinations by using color-coded VNCa reconstructions. MRI evaluated by two separate experienced readers, blinded to clinical and dual-energy CT information, served as the standard of reference. Sensitivity and specificity were the primary metrics of diagnostic performance. Results A total of 112 herniated lumbar disks were depicted at MRI. VNCa showed higher overall sensitivity (612 of 672 [91%] vs 534 of 672 [80%]) and specificity (723 of 786 [92%] vs 665 of 786 [85%]) for detecting lumbar disk herniation compared with standard CT (all comparisons, P < .001). Interreader agreement was excellent for VNCa and substantial for standard CT (κ = 0.82 vs 0.67; P < .001). VNCa achieved superior diagnostic confidence, image quality, and noise scores compared with standard CT (all comparisons, P < .001). Conclusion Color-coded dual-energy CT virtual noncalcium reconstructions show substantially higher diagnostic performance and confidence for depicting lumbar disk herniation compared with standard CT. © RSNA, 2018.


Assuntos
Degeneração do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Radiology ; 293(2): 260-271, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502938

RESUMO

In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be reconstructed between 40 and 200 keV. Substantially improved iodine attenuation at lower kiloelectron volt levels and reduced beam-hardening artifacts at higher kiloelectron volt levels have been demonstrated from all major manufacturers of dual-energy CT units. Improved contrast attenuation with VM imaging at lower kiloelectron volt levels enables better delineation and diagnostic accuracy in the detection of various vascular or oncologic abnormalities. Low-kiloelectron-volt VM imaging may be useful for salvaging CT studies with suboptimal contrast material delivery or providing additional information on the arterial vasculature obtained from venous phase acquisitions. For patients with renal impairment, substantial reductions in the use of iodinated contrast material can be achieved by using lower-energy VM imaging. The authors recommend routine reconstruction of VM images at 50 keV when using dual-energy CT to exploit the increased contrast properties. For reduction of beam-hardening artifacts, VM imaging at 120 keV is useful for the initial assessment.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Doenças Cardiovasculares/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Neoplasias/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
10.
Eur Radiol ; 29(5): 2226-2232, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30488112

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based technique using iodine quantification and fat fraction analysis for the diagnosis of early acute pancreatitis METHODS: In this retrospective study, 45 patients (35 men and 10 women; mean age, 54.9 ± 14.0 years) with early acute pancreatitis were included. Serum lipase levels and follow-up examinations served as the reference standard. A matched control group (n = 45) was assembled for evaluation of material decomposition values of normal pancreatic parenchyma. Three blinded radiologists independently interpreted all cases on conventional grayscale DECT series. In addition, readers re-evaluated all cases by manually performing region-of-interest (ROI) measurements on pancreatic-phase DECT material density images of the head, body, and tail of each patient's pancreas. Receiver operating characteristic (ROC) curve analysis was performed to estimate the optimal threshold for discriminating between inflammatory and normal pancreas parenchyma. RESULTS: DECT-based iodine density values showed significant differences between inflammatory (1.8 ± 0.3 mg/mL) and normal pancreatic parenchyma (2.7 ± 0.7 mg/mL) (p ≤ 0.01). Fat fraction measurements showed no significant differences (p = 0.08). The optimal iodine density threshold for the diagnosis of acute pancreatitis was 2.1 mg/mL with a sensitivity of 96% and specificity of 77%. Iodine quantification revealed an area under the curve (AUC) of 0.86, significantly higher compared to standard image evaluation of the radiologists (AUC, 0.80; sensitivity, 78%; specificity, 82%) (p < 0.01). CONCLUSION: DECT using iodine quantification allows for diagnosis of early acute pancreatitis with higher sensitivity compared to standard image evaluation. KEY POINTS: • Iodine density values showed significant differences between inflammatory and normal pancreatic parenchyma. • DECT using iodine quantification allows for diagnosis of early acute pancreatitis. • An iodine density of ≤ 2.1 mg/mL optimizes the diagnosis of acute pancreatitis.


Assuntos
Iodo/farmacologia , Tomografia Computadorizada Multidetectores/métodos , Pâncreas/diagnóstico por imagem , Pancreatite/diagnóstico , Doença Aguda , Meios de Contraste/farmacologia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA