Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 32(12): 21936-21945, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38859535

RESUMO

We study the fluorescence of nanodiamond ensembles as a function of static external magnetic field and observe characteristic dip features close to the zero field with potential for magnetometry applications. We analyze the dependence of the feature's width and the contrast of the feature on the size of the diamond (in the range 30 nm-3000 nm) and on the strength of a bias magnetic field applied transversely to the field being scanned. We also perform optically detected magnetic resonance (ODMR) measurements to quantify the strain splitting of the zero-field ODMR resonance across various nanodiamond sizes and compare it with the width and contrast measurements of the zero-field fluorescence features for both nanodiamonds and bulk samples. The observed properties provide compelling evidence of cross-relaxation effects in the NV system occurring close to zero magnetic fields. Finally, the potential of this technique for use in practical magnetometry is discussed.

2.
Opt Lett ; 48(10): 2512-2514, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37186695

RESUMO

We present a design to increase the amount of collected fluorescence emitted by nitrogen-vacancy color centers in diamond used for quantum-sensing. An improvement was measured in collected fluorescence when comparing oppositely faced emitting surfaces by a factor of 3.8(1). This matches ray-tracing simulation results. This design therefore improves on the shot noise limited sensitivity in optical readout-based measurements of, for instance, magnetic and electric fields, pressure, temperature, and rotations.

3.
Phys Rev Lett ; 130(15): 153601, 2023 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-37115859

RESUMO

We demonstrate an alignment-based ^{87}Rb magnetometer that is immune to nonlinear Zeeman (NLZ) splitting, addressing an important problem in alkali-metal atomic magnetometry. In our scheme, there is a single magnetic resonance peak and well-separated hyperfine transition frequencies, making the magnetometer insensitive or even immune to NLZ-related heading errors. It is shown that the magnetometer can be implemented for practical measurements in geomagnetic environments, and the photon-shot-noise-limited sensitivity reaches 9 fT/sqrt[Hz] at 5 µT and remains at tens of fT/sqrt[Hz] at 50 µT at room temperature.

4.
Phys Rev Lett ; 130(6): 063201, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36827554

RESUMO

Achieving high energy resolution in spin systems is important for fundamental physics research and precision measurements, with alkali-noble-gas comagnetometers being among the best available sensors. We found a new relaxation mechanism in such devices, the gradient of the Fermi-contact-interaction field that dominates the relaxation of hyperpolarized nuclear spins. We report on precise control over spin distribution, demonstrating a tenfold increase of nuclear spin hyperpolarization and transverse coherence time with optimal hybrid optical pumping. Operating in the self-compensation regime, our ^{21}Ne-Rb-K comagnetometer achieves an ultrahigh inertial rotation sensitivity of 3×10^{-8} rad/s/Hz^{1/2} in the frequency range from 0.2 to 1.0 Hz, which is equivalent to the energy resolution of 3.1×10^{-23} eV/Hz^{1/2}. We propose to use this comagnetometer to search for exotic spin-dependent interactions involving proton and neutron spins. The projected sensitivity surpasses the previous experimental and astrophysical limits by more than 4 orders of magnitude.

5.
Proc Natl Acad Sci U S A ; 117(20): 10667-10672, 2020 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-32376633

RESUMO

The ever-increasing demand for high-capacity rechargeable batteries highlights the need for sensitive and accurate diagnostic technology for determining the state of a cell, for identifying and localizing defects, and for sensing capacity loss mechanisms. Here, we leverage atomic magnetometry to map the weak induced magnetic fields around Li-ion battery cells in a magnetically shielded environment. The ability to rapidly measure cells nondestructively allows testing even commercial cells in their actual operating conditions, as a function of state of charge. These measurements provide maps of the magnetic susceptibility of the cell, which follow trends characteristic for the battery materials under study upon discharge. In particular, hot spots of charge storage are identified. In addition, the measurements reveal the capability to measure transient internal current effects, at a level of µA, which are shown to be dependent upon the state of charge. These effects highlight noncontact battery characterization opportunities. The diagnostic power of this technique could be used for the assessment of cells in research, quality control, or during operation, and could help uncover details of charge storage and failure processes in cells.

6.
Phys Rev Lett ; 127(17): 173605, 2021 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-34739270

RESUMO

Stand-off magnetometry allows measuring magnetic field at a distance, and can be employed in geophysical research, hazardous environment monitoring, and security applications. Stand-off magnetometry based on resonant scattering from atoms or molecules is often limited by the scarce amounts of detected light. The situation would be dramatically improved if the light emitted by excited atoms were to propagate towards the excitation light source in a directional manner. Here, we demonstrate that this is possible by means of mirrorless lasing. In a tabletop experiment, we detect free-precession signals of ground-state sodium spins under the influence of an external magnetic field by measuring backward-directed light. This method enables scalar magnetometry in the Earth field range, that can be extended to long-range remote sensing.

7.
Phys Rev Lett ; 126(14): 141802, 2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33891466

RESUMO

We report the results of an experimental search for ultralight axionlike dark matter in the mass range 162-166 neV. The detection scheme of our Cosmic Axion Spin Precession Experiment is based on a precision measurement of ^{207}Pb solid-state nuclear magnetic resonance in a polarized ferroelectric crystal. Axionlike dark matter can exert an oscillating torque on ^{207}Pb nuclear spins via the electric dipole moment coupling g_{d} or via the gradient coupling g_{aNN}. We calibrate the detector and characterize the excitation spectrum and relaxation parameters of the nuclear spin ensemble with pulsed magnetic resonance measurements in a 4.4 T magnetic field. We sweep the magnetic field near this value and search for axionlike dark matter with Compton frequency within a 1 MHz band centered at 39.65 MHz. Our measurements place the upper bounds |g_{d}|<9.5×10^{-4} GeV^{-2} and |g_{aNN}|<2.8×10^{-1} GeV^{-1} (95% confidence level) in this frequency range. The constraint on g_{d} corresponds to an upper bound of 1.0×10^{-21} e cm on the amplitude of oscillations of the neutron electric dipole moment and 4.3×10^{-6} on the amplitude of oscillations of CP-violating θ parameter of quantum chromodynamics. Our results demonstrate the feasibility of using solid-state nuclear magnetic resonance to search for axionlike dark matter in the neV mass range.

8.
Opt Express ; 27(2): 1706-1717, 2019 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-30696232

RESUMO

We propose a hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magnetometer that can be operated at room-temperature. The sensitivity to the magnetic field limited by the photonshot-noise of the output laser beam is estimated to be less than 1 pT/Hz. Unlike usual NV center infrared magnetometry, this method would not require an external frequency stabilized laser. Since the proposed system relies on the competition between the laser threshold and an intracavity absorption, such laser-based optical sensor could be easily adapted to a broad variety of sensing applications based on absorption spectroscopy.

9.
Phys Rev Lett ; 122(19): 191302, 2019 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-31144940

RESUMO

We report the results of a search for axionlike dark matter using nuclear magnetic resonance (NMR) techniques. This search is part of the multifaceted Cosmic Axion Spin Precession Experiment program. In order to distinguish axionlike dark matter from magnetic fields, we employ a comagnetometry scheme measuring ultralow-field NMR signals involving two different nuclei (^{13}C and ^{1}H) in a liquid-state sample of acetonitrile-2-^{13}C (^{13}CH_{3}CN). No axionlike dark matter signal was detected above the background. This result constrains the parameter space describing the coupling of the gradient of the axionlike dark matter field to nucleons to be g_{aNN}<6×10^{-5} GeV^{-1} (95% confidence level) for particle masses ranging from 10^{-22} eV to 1.3×10^{-17} eV, improving over previous laboratory limits for masses below 10^{-21} eV. The result also constrains the coupling of nuclear spins to the gradient of the square of the axionlike dark matter field, improving over astrophysical limits by orders of magnitude over the entire range of particle masses probed.

10.
Phys Rev Lett ; 120(3): 033202, 2018 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-29400503

RESUMO

The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.

11.
Opt Lett ; 42(20): 4163-4166, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29028038

RESUMO

Dynamic hybrid optical pumping effects with a radio-frequency field-driven nonlinear magneto-optical rotation scheme are studied in a dual-species paraffin coated vapor cell. By pumping K atoms and probing Rb87 atoms, we achieve an intrinsic magnetic resonance linewidth of 3 Hz, and the observed resonance is immune to power broadening and light-shift effects. Such an operation scheme shows favorable prospects for atomic magnetometry applications.

12.
Opt Express ; 24(14): 15383-90, 2016 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-27410814

RESUMO

Light shifts are an important source of noise and systematics in optically pumped magnetometers. We demonstrate that the long spin-coherence time in paraffin-coated cells leads to spatial averaging of the vector light shift over the entire cell volume. This renders the averaged vector light shift independent, under certain approximations, of the light-intensity distribution within the sensor cell. Importantly, the demonstrated averaging mechanism can be extended to other spatially varying phenomena in anti-relaxation-coated cells with long coherence times.

13.
Opt Lett ; 39(22): 6367-70, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25490470

RESUMO

We demonstrate magnetic induction tomography (MIT) with an all-optical atomic magnetometer. Our instrument creates a conductivity map of conductive objects. Both the shape and size of the imaged samples compare very well with the actual shape and size. Given the potential of all-optical atomic magnetometers for miniaturization and extreme sensitivity, the proof-of-principle presented in this Letter opens up promising avenues in the development of instrumentation for MIT.


Assuntos
Magnetometria/instrumentação , Dispositivos Ópticos , Rubídio , Tomografia/instrumentação , Miniaturização
15.
Sci Rep ; 12(1): 324, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013346

RESUMO

Searches for pseudo-magnetic spin couplings require implementation of techniques capable of sensitive detection of such interactions. While Spin-Exchange Relaxation Free (SERF) magnetometry is one of the most powerful approaches enabling the searches, it suffers from a strong magnetic coupling, deteriorating the pseudo-magnetic coupling sensitivity. To address this problem, here, we compare, via numerical simulations, the performance of SERF magnetometer and noble-gas-alkali-metal co-magnetometer, operating in a so-called self-compensating regime. We demonstrate that the co-magnetometer allows reduction of the sensitivity to low-frequency magnetic fields without loss of the sensitivity to nonmagnetic couplings. Based on that we investigate the responses of both systems to the oscillating and transient spin perturbations. Our simulations reveal about five orders of magnitude stronger response to the neutron pseudo-magnetic coupling and about three orders of magnitude stronger response to the proton pseudo-magnetic coupling of the co-magnetometer than those of the SERF magnetometer. Different frequency responses of the co-magnetometer to magnetic and nonmagnetic perturbations enables differentiation between these two types of interactions. This outlines the ability to implement the co-magnetometer as an advanced sensor for the Global Network of Optical Magnetometer for Exotic Physics searches (GNOME), aiming at detection of ultra-light bosons (e.g., axion-like particles).

16.
Nat Commun ; 13(1): 7387, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36450723

RESUMO

Experimental searches for exotic spin-dependent forces are attracting a lot of attention because they allow to test theoretical extensions to the standard model. Here, we report an experimental search for possible exotic spin-dependent force, specifically spin-and-velocity-dependent forces, by using a K-Rb-21Ne co-magnetometer and a tungsten ring featuring a high nucleon density. Taking advantage of the high sensitivity of the co-magnetometer, the pseudomagnetic field from this exotic force is measured to be ≤7 aT. This sets limits on coupling constants for the neutron-nucleon and proton-nucleon interactions in the range of ≥0.1 m (mediator boson mass ≤2 µeV). The coupling constant limits are established to be [Formula: see text] and [Formula: see text], which are more than one order of magnitude tighter than astronomical and cosmological limits on the coupling between the new gauge boson such as Z' and standard model particles.

17.
EBioMedicine ; 82: 104152, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35834887

RESUMO

BACKGROUND: Tremors are frequent and disabling in people with multiple sclerosis (MS). Characteristic tremor frequencies in MS have a broad distribution range (1-10 Hz), which confounds the diagnostic from other forms of tremors. In this study, we propose a classification method for distinguishing MS tremors from other forms of cerebellar tremors. METHODS: Electromyogram (EMG), accelerometer and clinical data were obtained from a total of 120 [40 MS, 41 essential tremor (ET) and 39 Parkinson's disease (PD)] subjects. The proposed method - Soft Decision Wavelet Decomposition (SDWD) - was used to compute power spectral densities and receiver operating characteristic (ROC) analysis was performed for the automatic classification of the tremors. Association between the spectral features and clinical features (FTM - Fahn-Tolosa-Marin scale, UPDRS - Unified Parkinson's Disease Rating Scale), was assessed using a support vector regression (SVR) model. FINDINGS: Our developed analytical framework achieved an accuracy of up to 91.67% using accelerometer data and up to 91.60% using EMG signals for the differentiation of MS tremors and the tremors from ET and PD. In addition, SVR further revealed strong significant correlations between the selected discriminators and the clinical scores. INTERPRETATION: The proposed method, with high classification accuracy and strong correlations of these features to clinical outcomes, has clearly demonstrated the potential to complement the existing tremor-diagnostic approach in MS patients. FUNDING: This work was supported by the German Research Foundation (DFG): SFB-TR-128 (to SG, MM), MU 4354/1-1(to MM) and the Boehringer Ingelheim Fonds BIF-03 (to SG, MM).


Assuntos
Tremor Essencial , Esclerose Múltipla , Doença de Parkinson , Tremor Essencial/diagnóstico , Humanos , Aprendizado de Máquina , Esclerose Múltipla/diagnóstico , Doença de Parkinson/diagnóstico , Tremor/diagnóstico , Tremor/etiologia
18.
Biomed Tech (Berl) ; 67(5): 333-344, 2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-35960879

RESUMO

Transcranial magnetic stimulation (TMS) has widespread clinical applications from diagnosis to treatment. We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPMs) inside a portable shield that encloses only the forearm and hand of the subject. We present magnetomyograms (MMG)s of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) data. The biomagnetic signals recorded in the MMG provides detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond that of the EMG. This system demonstrates the value of biomagnetic signals in TMS-based clinical approaches and widens its availability and practical potential.


Assuntos
Movimento , Estimulação Magnética Transcraniana , Eletromiografia , Potencial Evocado Motor/fisiologia , Mãos/fisiologia , Humanos , Movimento/fisiologia
19.
J Magn Reson ; 322: 106867, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33423759

RESUMO

Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while keeping stray fields at a minimum. Here, we present the design, construction, and characterization for a stack of two Halbach rings with 10 cm inner diameter providing a homogeneous (<100 ppm over 1.0×1.0×0.5cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup. The final characterization is performed with a novel fiberized diamond-based sensor on a 3D translation stage documenting the high homogeneity of the constructed Halbach array and its suitability for the proposed use.

20.
Nat Commun ; 12(1): 7321, 2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34916510

RESUMO

Numerous theories extending beyond the standard model of particle physics predict the existence of bosons that could constitute dark matter. In the standard halo model of galactic dark matter, the velocity distribution of the bosonic dark matter field defines a characteristic coherence time τc. Until recently, laboratory experiments searching for bosonic dark matter fields have been in the regime where the measurement time T significantly exceeds τc, so null results have been interpreted by assuming a bosonic field amplitude Φ0 fixed by the average local dark matter density. Here we show that experiments operating in the T ≪ τc regime do not sample the full distribution of bosonic dark matter field amplitudes and therefore it is incorrect to assume a fixed value of Φ0 when inferring constraints. Instead, in order to interpret laboratory measurements (even in the event of a discovery), it is necessary to account for the stochastic nature of such a virialized ultralight field. The constraints inferred from several previous null experiments searching for ultralight bosonic dark matter were overestimated by factors ranging from 3 to 10 depending on experimental details, model assumptions, and choice of inference framework.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA