1.
Physiol Rep ; 11(12): e15746, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37332094

RESUMO

Longitudinal motion of the carotid arterial wall, as measured with ultrasound, has shown promise as an indicator of vascular health. The underlying mechanisms are however not fully understood. We have found, in in vivo studies, that blood pressure has a strong relation to the antegrade longitudinal displacement in early systole. Further, we have identified that a tapered geometry and the intramural friction in-between two parts of a vessel wall influence the longitudinal displacement. We therefore studied the interaction between pressure, vessel geometry and intramural friction, tapered and straight ultrasound phantoms in a paralleled hydraulic bench study and corresponding numerical models. Profound antegrade longitudinal motion was induced in the innermost part of both tapered phantoms and the numerical models, but to a lesser extent when intramural friction was increased in the simulations. Strong correlations (R = 0.82-0.96; p < 1e-3; k = 9.3-14 µm/mmHg) between longitudinal displacement and pulse pressure were found in six of seven regions of interest in tapered phantoms. The motion of the straight phantom and the corresponding numerical model was smaller, on average zero or close to zero. This study demonstrates that tapering of the lumen, low intramural friction, and pressure might be important conducive features to the antegrade longitudinal motion of the arterial wall in vivo.


Assuntos
Artérias Carótidas , Fricção , Análise de Elementos Finitos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Ultrassonografia , Pressão Sanguínea/fisiologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-27529873

RESUMO

The longitudinal movement of the arterial wall of large human arteries has shown promise to be an independent indicator of vascular health. Despite growing interest in this movement, its nature, causes, and implications are not fully understood, and existing phantoms have failed to show a pure longitudinal movement that is not secondary to the distension. An often overlooked aspect of the arterial wall is the interaction between the different layers. The longitudinal movement of the innermost layers, the intima and media, can be several hundred micrometers in the direction of flow during early systole. This is markedly larger than that of the adventitia, indicating that sliding occurs between the two layers. This feature was incorporated into a phantom by casting it in two parts. The molds were developed in-house using mainly a 3-D printer, a versatile and easy production method. Additionally, the phantom contains a tapered region. Using the phantom, we were able to demonstrate a pure longitudinal movement; when it was subjected to a pulsatile pressure, the wall displaced 220 [Formula: see text] (SD 40) radially and 560 [Formula: see text] (SD 74) longitudinally distal to the tapering. The motion followed the pressure variations. This paper serves as a guide for phantom production, explaining each step of the process.


Assuntos
Artérias/diagnóstico por imagem , Modelos Cardiovasculares , Imagens de Fantasmas , Ultrassonografia/instrumentação , Artérias/fisiologia , Desenho de Equipamento , Humanos , Impressão Tridimensional