Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 32(1): 68-75, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35931335

RESUMO

BACKGROUND: The purpose of this study was to (1) evaluate whether improved external rotation (ER) in patients with preoperative ER <0° impacts their clinical outcomes following reverse shoulder arthroplasty (RSA) for rotator cuff (RC) pathology and (2) describe the differences in preoperative factors and postoperative outcomes in this patient population. Our hypothesis was that clinical outcomes would not be affected by improvement in ER using a lateralized glenosphere design. METHODS: We retrospectively reviewed 55 patients with preoperative ER <0° who underwent primary RSA for RC pathology with lateralized glenosphere. Pre- and postoperative physician-reported ER was blindly measured using a videographic review of patients externally rotating their arm at the side. Patients were evaluated using 5 different patient-reported outcome score thresholds, measured at 12 months postoperatively: (1) minimal clinically important difference (MCID) for American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) scores (ie, ≥20-point increase); (2) MCID for Simple Shoulder Test (SST) scores (≥2.4-point increase); (3) visual analog scale (VAS) for pain score >0; (4) mean ASES score (≥75); and (5) mean SST score (≥6.8), each of which was used to stratify the patients into 2 groups-greater than or equal to vs. less than the threshold. This resulted in 5 different evaluations comparing the 2 groups for any difference in postoperative ER or preoperative factors, including Hamada and Goutallier scores. RESULTS: Regardless of the measured outcome, there was no difference in either postoperative physician- or patient-reported ER between patients who achieved scores higher or lower than the thresholds. Both Hamada and Goutallier score distributions were not different between groups across all the evaluated outcomes. Patients who achieved the MCID for ASES had worse preoperative VAS pain (7 vs. 4, P = .011) and SST (1 vs. 3, P = .020) scores. Across all outcome thresholds, except MCID for SST, pain reduction (ΔVAS) was significantly more pronounced in patients exceeding the thresholds. Improved forward flexion rather than ER was observed in those who achieved the ASES (160° vs. 80°, P = .020) and SST MCIDs (150° vs. 90°, P = .037). Finally, patients who exceeded the thresholds experienced higher satisfaction rates. CONCLUSION: Improvement in ER does not appear to impact patient-reported outcome measures, including ASES and SST in patients with preoperative ER <0° undergoing RSA with a lateralized glenosphere. Patients with more severe pain and worse function at baseline experience less postoperative pain and clinically significant improvement in their reported outcomes.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Lesões do Manguito Rotador/cirurgia , Amplitude de Movimento Articular , Dor Pós-Operatória
2.
J Shoulder Elbow Surg ; 31(6S): S136-S142, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35182767

RESUMO

BACKGROUND: Severe glenoid bone loss (SGBL) poses significant technical challenges. Adequate fixation of glenoid implants may require the use of alternative screw placement. Although bone volumes for the spine and lateral pillars have previously been defined, insufficient evidence exists regarding the distribution of screw placement for fixation in such regions for cases with SGBL. The purpose of this study is to evaluate the variability of screw placement. We hypothesize that determining this variability and establishing common patterns of glenoid bone loss will allow for recommendations for preoperative planning, and implant design and selection. METHODS: An internal registry of 2 high-volume shoulder and elbow surgeons was queried, and 65 three-dimensional scapulae models exhibiting SGBL were identified. A fellowship-trained shoulder and elbow surgeon simulated the placement of two 3.5 mm × 30 mm screws, one in the scapular spine (CS) bone volume and one in the inferior column (IS) bone volume. Three orthogonal reference planes were created using anatomic reference points: the scapula trigonum, estimated glenoid center, and inferior pole. Screw positions were mapped, and deviations from the reference planes were calculated. Mutual positions of the IS to CS were also computed. Intraobserver reliability was assessed using 10 randomly selected samples. Median and 25th and 75th percentiles were reported for screw orientation distributions. Means and standard deviations were reported for screw head positions. RESULTS: We demonstrated excellent intraobserver reliability (intraclass correlation coefficients, 0.90-0.98). Fifty percent of CS were oriented 10° ± 5° of retroversion from the scapula plane, with 5° ± 5° of inclination. For IS, 50% were positioned 0° ± 4° from the scapula plane, with -33° ± 7° of inclination. The relationship of the IS with the CS was medial and posterior in 49% of cases, lateral and posterior in 45%, and lateral and anterior in 6% of cases. On average, the distance between the CS and IS heads was 25 mm ± 4 mm. DISCUSSION: For SGBL, adequate fixation of glenoid implants can be achieved by placing screws in the spine and lateral columns, with excellent reproducibility. Future implant designs should accommodate CS positioned -16° to -5° from the scapula plane, with 0° to 12° of inclination, and IS positioned -6° to 4° from the scapula plane, with -40° to -25° of inclination. Moreover, mutual screw positions suggested bone loss distributions anteriorly and inferiorly. Future implant designs should consider the potential benefits of augmentation to accommodate interscrew distances of 21-29 mm and anatomic locations of the IS relative to the CS.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Parafusos Ósseos , Humanos , Reprodutibilidade dos Testes , Escápula/cirurgia , Articulação do Ombro/cirurgia
3.
J Shoulder Elbow Surg ; 31(8): e386-e398, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35339705

RESUMO

BACKGROUND: The rationale for advances in implant design is to improve performance in comparison to their predecessors. The purpose of this study was to compare a newer, self-pressurizing peripheral peg glenoid to a traditional polyethylene pegged glenoid through biomechanical evaluation and a retrospective radiographic and clinical review. METHODS: Three testing conditions (uncemented, partially cemented, and fully cemented) were chosen to assess the 2 component designs in a foam block model. The number of hammer hits to seat the component, amount of time to seat the component, and resistance-to-seat were collected. The implants were then cyclically loaded following ASTM F2028-17 testing standard. Clinically, postoperative radiographs of patients with a self-pressurized glenoid component (n = 225 patients) and traditional glenoid component (n = 206 patients) were evaluated for radiolucent lines and glenoid seating at various timepoints. Clinical outcomes (American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, Simple Shoulder Test, and visual analog scale pain scores) and complications were recorded. The presence of radiolucent lines at the bone-cement interface was evaluated using the Modified Franklin Grade and the Lazarus grade. RESULTS: The self-pressurizing glenoid design required significantly more hammer hits than traditional glenoid designs in all groups tested (P < .029). Moreover, the self-pressurizing design had significantly more resistance-to-seat than traditional components in both the uncemented and partially cemented group (P < .002). No difference in resistance-to-seat was found between designs in the fully cemented group. The uncemented and partially cemented groups did not survive the full 50,000 cycles; however the self-pressurizing design had significantly less motion than the traditional design (P < .001). No differences between component designs were found in the fully cemented group at 50,000 cycles. The self-pressurizing glenoid component had 0.005% radiographic radiolucent lines, and the traditional glenoid component had 45% radiographic radiolucent lines, with 38% of the radiolucencies in the traditional glenoid component group being defined as grade E. There were no progressive radiolucencies, differences in clinical outcomes, or complications at 2 years postoperatively. CONCLUSION: In the fully cemented condition, the 2 component designs had comparable performance; however, the differences in designs could be better observed in the uncemented group. The self-pressurizing all-polyethylene design studied has superior biomechanical stability. Clinically, the improved stability of the glenoid component correlated with a reduction of radiolucent lines and will likely lead to a reduction in glenoid component loosening.


Assuntos
Cavidade Glenoide , Articulação do Ombro , Seguimentos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-36733708

RESUMO

Variations among methods to measure glenoid version have created uncertainty regarding which method provides the most consistent measurements of morphology. Greater deformity may also make accurate depiction of the native morphology more challenging. This study examined 4 current methods (Friedman, corrected Friedman, Ganapathi-Iannotti, and Matsumura) and an experimental scapular border-derived coordinate system method, to compare measurement inconsistencies between methods and reference systems and assess the impact of glenoid deformity on measured glenoid version. Methods: Three-dimensional scapulae were created from computed tomography (CT) scans of 74 shoulders that had undergone arthroplasty (28 A2, 22 B2, 10 B3, and 14 C glenoids) and 34 shoulders that had not undergone arthroplasty. Glenoid version measurements were made in Mimics using the 4 methods. For the experimental method, scapulae were reconstructed, and 3 orthogonal global coordinate planes (GCPs) were derived from the medial and lateral borders. Version was measured as the angle between the sagittal reference plane and an anterior-posterior glenoid vector. The intraclass correlation coefficient (ICC) was calculated for the Friedman and corrected Friedman methods. Inconsistencies were assessed for all methods using the interquartile range, mean and standard deviation, and repeated-measures analysis of variance. Concordance correlation coefficients (CCCs) were calculated to assess agreement among the methods. Results: Scapular plane-based methods (experimental, Friedman, and corrected Friedman) yielded an average version between -10° and -12°, with average measurement differences among these methods of <2°. Vault methods (Ganapathi-Iannotti and Matsumura) overestimated or underestimated version by an average of 5° to 7° compared with scapular plane-based methods, and showed significant differences of >12° when compared with each other. Scapular plane-based methods maintained consistency with increasing deformity. Conclusions: The other methods of version measurement using the scapular planes as the reference were highly comparable with the corrected Friedman method. However, when the reference plane was the glenoid vault, version measurements were inconsistent with scapular plane-based methods, which is attributed to differences in the reference systems. In surgical planning, the coordinate system utilized will impact version measurements, which can result in variations in the planned surgical solutions. Additionally, as glenoid deformity increases, this variation resulting from the utilization of different coordinate systems is magnified.

5.
Cureus ; 15(6): e40601, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37469809

RESUMO

Introduction Gynecological teaching associates (GTAs) are trained to teach the pelvic exam using themselves as models, and it has been hypothesized that their use can improve learners' confidence and interpersonal skills. This study aims to gain greater insight into whether the use of GTAs is associated with increased medical students' confidence when performing the pelvic exam during clinical rotations. Methods An email survey was distributed to medical students in two different classes at a single United States Medical Licensing Examination (USMLE)-accredited medical school: one that learned the pelvic exam using GTAs and one that did not. A Fisher's exact test was performed to determine associations between the use of GTAs and confidence in performing the pelvic exam, with a p-value of <0.01. Results Out of the 85 survey participants, 68 had performed a pelvic exam in the clinical setting and thus rated their confidence level. Of the 38 students who learned using a GTA, 66% (p<0.0024) reported a confidence level of four or five (out of five) compared to 50% of the 30 students who were not able to practice using a GTA. There was a statistically significant difference in the confidence levels of students who practiced on GTAs compared to those who did not. Discussion Our findings demonstrated that students who were able to learn the pelvic exam using GTAs reported higher confidence levels when subsequently performing a pelvic exam in a clinical setting. Conclusion Our findings support investment in GTA programming for teaching the pelvic exam in medical school curricula.

6.
Obstet Gynecol ; 140(1): 91-93, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35849462

RESUMO

Immediate postpartum placement of intrauterine devices (IUDs) can help reduce unintended short-interval pregnancy; however, the rate of spontaneous device expulsion is increased. The objective of this study is to evaluate the risk of expulsion with ultrasound-guided placement of immediate postpartum IUDs. Retrospective review of all patients receiving immediate postpartum IUDs after vaginal delivery at Prisma Health Richland Hospital from 2018 to 2020 was performed. Outcomes were available for 78 patients in the ultrasound-guided cohort and for 226 in the control cohort. The expulsion rate was 15.4% (95% CI 8.2-25.3%) for the ultrasound-guided cohort and 14.2% (95% CI 9.9-19.4%) for the control cohort. Our data suggest that using ultrasonography to guide placement of IUDs immediately after vaginal delivery is not associated with the risk of expulsion.


Assuntos
Dispositivos Intrauterinos , Parto Obstétrico , Feminino , Humanos , Expulsão de Dispositivo Intrauterino , Período Pós-Parto , Gravidez , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA