Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Appl Microbiol ; 123(3): 582-593, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28419654

RESUMO

Synthetic plastics, which are widely present in materials of everyday use, are ubiquitous and slowly-degrading polymers in environmental wastes. Of special interest are the capabilities of microorganisms to accelerate their degradation. Members of the metabolically diverse genus Pseudomonas are of particular interest due to their capabilities to degrade and metabolize synthetic plastics. Pseudomonas species isolated from environmental matrices have been identified to degrade polyethylene, polypropylene, polyvinyl chloride, polystyrene, polyurethane, polyethylene terephthalate, polyethylene succinate, polyethylene glycol and polyvinyl alcohol at varying degrees of efficiency. Here, we present a review of the current knowledge on the factors that control the ability of Pseudomonas sp. to process these different plastic polymers and their by-products. These factors include cell surface attachment within biofilms, catalytic enzymes involved in oxidation or hydrolysis of the plastic polymer, metabolic pathways responsible for uptake and assimilation of plastic fragments and chemical factors that are advantageous or inhibitory to the biodegradation process. We also highlight future research directions required in order to harness fully the capabilities of Pseudomonas sp. in bioremediation strategies towards eliminating plastic wastes.


Assuntos
Plásticos/metabolismo , Pseudomonas/metabolismo , Biodegradação Ambiental , Plásticos/síntese química , Polietilenos/metabolismo , Poliestirenos/metabolismo , Pseudomonas/classificação , Pseudomonas/genética , Pseudomonas/isolamento & purificação , Succinatos/metabolismo
2.
Arch Orthop Trauma Surg ; 129(2): 225-6, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18297294

RESUMO

Bone transport for large femoral segmental bone defects is a technically challenging task. We describe a patient with a 14 cm bone loss at the metaphyseal/diaphyseal junction of the distal femur, treated with a monolateral/ring fixator hybrid. We propose that such combination can provide sufficient stability for bone tranport to be successfully completed.


Assuntos
Regeneração Óssea , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Osteogênese por Distração/instrumentação , Acidentes de Trânsito , Consolidação da Fratura , Humanos , Motocicletas
3.
Proc Inst Mech Eng H ; 209(3): 197-202, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8519409

RESUMO

A novel fine wire bone transport system for use with Ilizarov frames has been used in Bristol. It uses parallel wires instead of crossed wires. Its stiffness has been tested and compared with a crossed wire construct. In its basic form it is not as stiff to bending and shear loading, however, by modification it can be made at least as stiff. A parallel wire construct does not transfix as much soft tissue as a crossed wire construct when used in the leg. This is advantageous, because soft tissue transfixion causes pain and limb swelling, which impair patient mobilization.


Assuntos
Fios Ortopédicos , Osso e Ossos , Fixadores Externos , Técnica de Ilizarov , Fenômenos Biomecânicos , Osso e Ossos/fisiologia , Humanos , Modelos Biológicos , Movimento , Osteogênese
4.
Injury ; 43(7): 1135-40, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22465515

RESUMO

The aim of the present study was to investigate the safety and efficacy of local implantation of BMP-7 for the treatment of resistant non-unions in the upper and lower limb. Fifty-two patients (30 males, mean age 52.8 years; range 20-81) were treated with local BMP-7 implantation in a bovine bone-derived collagen paste with or without revision of fixation. Thirty-six patients had closed injuries, ten had open injuries and six had infected non-unions. Patients had undergone a mean of 2 (1-5) operations prior to implantation of BMP-7. Clinical and radiological union was achieved in 94% at a mean time of 5.6 months (3-19). Two patients with subtrochanteric femoral fractures failed to achieve union secondary to inadequate fracture stabilisation, persistent unfavourable biological environment and systemic co-morbidities. One patient developed synostosis attributed to the BMP-7 application. This study demonstrates BMP-7 implanted in a bovine-derived collagen paste is an effective adjunctive treatment for resistant non-unions in the upper and lower limb.


Assuntos
Proteína Morfogenética Óssea 7/administração & dosagem , Consolidação da Fratura/efeitos dos fármacos , Fraturas Ósseas/tratamento farmacológico , Fraturas não Consolidadas/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Proteína Morfogenética Óssea 7/farmacologia , Feminino , Fraturas do Fêmur/tratamento farmacológico , Seguimentos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/fisiopatologia , Humanos , Fraturas do Úmero/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Fraturas do Ombro/tratamento farmacológico , Fraturas da Tíbia/tratamento farmacológico , Resultado do Tratamento , Fraturas da Ulna/tratamento farmacológico
7.
Ann R Coll Surg Engl ; 91(1): 63-5, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18990262

RESUMO

INTRODUCTION: External fixator frames are widely used in limb reconstruction surgery. They are used for relatively long periods and the multidimensional impact on patients is documented. We examined the role of a nurse-led specialist group when supporting patients both pre-operatively and postoperatively. PATIENTS AND METHODS: All patients with external fixators were contacted via postal questionnaire. Questions asked covered regularity of attendance at the specialist group, information received and problems with the frames. RESULTS: Thirty-seven patients replied. Twenty-one had attended the clinic and nearly all (32) had been offered the opportunity to attend. Most reported being well prepared for surgery and felt that the information given was satisfactory. Problems were generally addressed within the group and patients attended the group with frame-related problems before attending their general practitioner or the accident and emergency department. All patients found the group environment supportive. CONCLUSIONS: We describe a unique patient support group. To our knowledge, it is the first in the country. It is a valuable resource in equipping patients prior to surgery as well as dealing with problems that arise with the frame in situ. We recommend it to other limb reconstruction units.


Assuntos
Fios Ortopédicos , Fixadores Externos , Extremidades/cirurgia , Satisfação do Paciente , Procedimentos de Cirurgia Plástica/psicologia , Grupos de Autoajuda , Humanos , Técnica de Ilizarov/psicologia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Educação de Pacientes como Assunto , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Procedimentos de Cirurgia Plástica/enfermagem
8.
Ann R Coll Surg Engl ; 91(7): 596-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19558771

RESUMO

INTRODUCTION: The aim of this study was to compare the effectiveness of different ways of referring patients to an osteoporosis assessment service at an orthopaedic fracture clinic of a hospital in the UK. PATIENTS AND METHODS: Three methods of identifying and referring to an osteoporosis assessment service were evaluated. RESULTS: Relying on doctors for such a referral gave a catchment rate of only 1.6%. Involving patients themselves, asking them to self-refer, increased the catchment rate to 63% (P < 0.0001). Having a specialist osteoporosis and fracture liaison nurse present in clinic and reviewing the notes of patients checking in, to see if they match criteria for osteoporosis assessment, further increased catchment to 77% (P = 0.036). CONCLUSIONS: Simply having an osteoporosis assessment service and strict criteria to identify which patients should be referred to such a service will not necessarily increase catchment rate for osteoporosis patients. A nurse physically present in the clinic provided the best result, and supports the need of investing in an osteoporosis and fracture liaison nurse.


Assuntos
Fraturas Espontâneas/etiologia , Osteoporose/diagnóstico , Encaminhamento e Consulta/organização & administração , Idoso , Fraturas Espontâneas/enfermagem , Humanos , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/enfermagem , Educação de Pacientes como Assunto/métodos , Avaliação de Programas e Projetos de Saúde , Encaminhamento e Consulta/normas , Encaminhamento e Consulta/estatística & dados numéricos , Especialidades de Enfermagem/organização & administração , Reino Unido
9.
J Trauma ; 34(2): 309, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8459479

RESUMO

Fractures of the clavicle and scapula are usually treated conservatively. After malunion functional results are usually good, however, function and shoulder contour can be improved by corrective osteotomies.


Assuntos
Fraturas não Consolidadas/cirurgia , Osteotomia/métodos , Escápula/lesões , Traumatismos Torácicos/complicações , Clavícula/diagnóstico por imagem , Clavícula/lesões , Clavícula/cirurgia , Feminino , Fraturas não Consolidadas/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Radiografia , Escápula/diagnóstico por imagem , Escápula/cirurgia
10.
J Trauma ; 36(3): 356-7, 1994 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8145316

RESUMO

Proximal tibial fractures below an osteoarthritic knee have a greater risk of nonunion. Treatment by cast immobilization alone is problematic. Internal fixation alone means the patient will remain handicapped because of the knee. Total knee replacement with a long-stemmed prosthesis treats both the fracture and the arthritic knee.


Assuntos
Fraturas não Consolidadas/cirurgia , Prótese do Joelho , Osteoartrite/complicações , Fraturas da Tíbia/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas não Consolidadas/complicações , Fraturas não Consolidadas/diagnóstico por imagem , Humanos , Masculino , Radiografia , Fraturas da Tíbia/complicações , Fraturas da Tíbia/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA