Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 116(2): e5-e7, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-35932792

RESUMO

Endovascular devices have become increasingly available, which has led to an increase in use of frozen elephant trunk stents for extended repair during type A aortic dissection. Frozen elephant trunk deployment is usually done under direct visualization of both the true and false lumen but rarely, the endograft can inadvertently end in the false lumen. This can lead to false lumen pressurization and end-organ malperfusion. Herein we describe a novel intraoperative rescue technique for misplaced frozen elephant trunk into the false lumen, easily executed in a standard operating room using transesophageal echocardiography and intravascular ultrasound guidance.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Stents , Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos
2.
J Neurosurg ; 120(5): 1179-87, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24628617

RESUMO

OBJECT: The aim of this study was to examine observer reliability of frequently used arteriovenous malformation (AVM) grading scales, including the 5-tier Spetzler-Martin scale, the 3-tier Spetzler-Ponce scale, and the Pollock-Flickinger radiosurgery-based scale, using current imaging modalities in a setting closely resembling routine clinical practice. METHODS: Five experienced raters, including 1 vascular neurosurgeon, 2 neuroradiologists, and 2 senior neurosurgical residents independently reviewed 15 MRI studies, 15 CT angiograms, and 15 digital subtraction angiograms obtained at the time of initial diagnosis. Assessments of 5 scans of each imaging modality were repeated for measurement of intrarater reliability. Three months after the initial assessment, raters reassessed those scans where there was disagreement. In this second assessment, raters were asked to justify their rating with comments and illustrations. Generalized kappa (κ) analysis for multiple raters, Kendall's coefficient of concordance (W), and interclass correlation coefficient (ICC) were applied to determine interrater reliability. For intrarater reliability analysis, Cohen's kappa (κ), Kendall's correlation coefficient (tau-b), and ICC were used to assess repeat measurement agreement for each rater. RESULTS: Interrater reliability for the overall 5-tier Spetzler-Martin scale was fair to good (ICC = 0.69) to extremely strong (Kendall's W = 0.73) on initial assessment and improved on reassessment. Assessment of CT angiograms resulted in the highest agreement, followed by MRI and digital subtraction angiography. Agreement for the overall 3-tier Spetzler-Ponce grade was fair to good (ICC = 0.68) to strong (Kendall's W = 0.70) on initial assessment, improved on reassessment, and was comparable to agreement for the 5-tier Spetzler-Martin scale. Agreement for the overall Pollock-Flickinger radiosurgery-based grade was excellent (ICC = 0.89) to extremely strong (Kendall's W = 0.81). Intrarater reliability for the overall 5-tier Spetzler-Martin grade was excellent (ICC > 0.75) in 3 of the 5 raters and fair to good (ICC > 0.40) in the other 2 raters. CONCLUSION: The 5-tier Spetzler-Martin scale, the 3-tier Spetzler-Ponce scale, and the Pollock-Flickinger radiosurgery-based scale all showed a high level of agreement. The improved reliability on reassessment was explained by a training effect from the initial assessment and the requirement to defend the rating, which outlines a potential downside for grades determined as part of routine clinical practice to be used for scientific purposes.


Assuntos
Angiografia Cerebral , Malformações Arteriovenosas Intracranianas/diagnóstico , Imageamento por Ressonância Magnética , Angiografia Digital , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/patologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA