J Cardiovasc Magn Reson ; 25(1): 34, 2023 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-37331930

RESUMO

The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free ("needle-free") and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination.


Assuntos
Infarto do Miocárdio , Humanos , Infarto do Miocárdio/patologia , Valor Preditivo dos Testes , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Espectroscopia de Ressonância Magnética
2.
J Cardiovasc Magn Reson ; 23(1): 120, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34689798

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is characterized by increased left ventricular wall thickness, cardiomyocyte hypertrophy, and fibrosis. Adverse cardiac risk characterization has been performed using late gadolinium enhancement (LGE), native T1, and extracellular volume (ECV). Relaxation time constants are affected by background field inhomogeneity. T1ρ utilizes a spin-lock pulse to decrease the effect of unwanted relaxation. The objective of this study was to study T1ρ as compared to T1, ECV, and LGE in HCM patients. METHODS: HCM patients were recruited as part of the Novel Markers of Prognosis in Hypertrophic Cardiomyopathy study, and healthy controls were matched for comparison. In addition to cardiac functional imaging, subjects underwent T1 and T1ρ cardiovascular magnetic resonance imaging at short-axis positions at 1.5T. Subjects received gadolinium and underwent LGE imaging 15-20 min after injection covering the entire heart. Corresponding basal and mid short axis LGE slices were selected for comparison with T1 and T1ρ. Full-width half-maximum thresholding was used to determine the percent enhancement area in each LGE-positive slice by LGE, T1, and T1ρ. Two clinicians independently reviewed LGE images for presence or absence of enhancement. If in agreement, the image was labeled positive (LGE + +) or negative (LGE --); otherwise, the image was labeled equivocal (LGE + -). RESULTS: In 40 HCM patients and 10 controls, T1 percent enhancement area (Spearman's rho = 0.61, p < 1e-5) and T1ρ percent enhancement area (Spearman's rho = 0.48, p < 0.001e-3) correlated with LGE percent enhancement area. T1 and T1ρ percent enhancement areas were also correlated (Spearman's rho = 0.28, p = 0.047). For both T1 and T1ρ, HCM patients demonstrated significantly longer relaxation times compared to controls in each LGE category (p < 0.001 for all). HCM patients also showed significantly higher ECV compared to controls in each LGE category (p < 0.01 for all), and LGE -- slices had lower ECV than LGE + + (p = 0.01). CONCLUSIONS: Hyperenhancement areas as measured by T1ρ and LGE are moderately correlated. T1, T1ρ, and ECV were elevated in HCM patients compared to controls, irrespective of the presence of LGE. These findings warrant additional studies to investigate the prognostic utility of T1ρ imaging in the evaluation of HCM patients.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/patologia , Fibrose , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Valor Preditivo dos Testes
3.
J Magn Reson Imaging ; 49(1): 59-68, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30390347

RESUMO

BACKGROUND: Uterine artery (UtA) hemodynamics might be used to predict risk of hypertensive pregnancy disorders, including preeclampsia and intrauterine growth restriction. PURPOSE OR HYPOTHESIS: To determine the feasibility of 4D flow MRI in pregnant subjects by characterizing UtA anatomy, computing UtA flow, and comparing UtA velocity, and pulsatility and resistivity indices (PI, RI) with transabdominal Doppler ultrasound (US). STUDY TYPE: Prospective cross-sectional study from June 6, 2016, to May 2, 2018. POPULATION OR SUBJECTS OR PHANTOM OR SPECIMEN OR ANIMAL MODEL: Forty-one singleton pregnant subjects (age [range] = 27.0 ± 5.9 [18-41] years) in their second or third trimester. We additionally scanned three subjects who had prepregnancy diabetes or chronic hypertension. FIELD STRENGTH/SEQUENCE: The subjects underwent UtA and placenta MRI using noncontrast angiography and 4D flow at 1.5T. ASSESSMENT: UtA anatomy was described based on 4D flow-derived noncontrast angiography, while UtA flow properties were characterized by net flow, systolic/mean/diastolic velocity, PI and RI through examination of 4D flow data. PI and RI are standard hemodynamic parameters routinely reported on Doppler US. STATISTICAL TESTS: Spearman's rank correlation, Wilcoxon signed rank tests, and Bland-Altman plots were used to preliminarily investigate the relationships between flow parameters, gestational age, and Doppler US. or RESULTS: 4D flow MRI and UtA flow quantification was feasible in all subjects. There was considerable heterogeneity in UtA geometry in each subject between left and right UtAs and between subjects. Mean 4D flow-based parameters were: mean bilateral flow rate = 605.6 ± 220.5 mL/min, PI = 0.72 ± 0.2, and RI = 0.47 ± 0.1. Bilateral flow did not change with gestational age. We found that MRI differed from US in terms of lower PI (mean difference -0.1) and RI (mean difference < -0.1) with Wilcoxon signed rank test P = 0.05 and P = 0.13, respectively. DATA CONCLUSION: 4D flow MRI is a feasible approach for describing UtA anatomy and flow in pregnant subjects. LEVEL OF EVIDENCE: Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:59-68.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Hemodinâmica , Hipertensão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pré-Eclâmpsia/diagnóstico por imagem , Ultrassonografia Doppler , Artéria Uterina/diagnóstico por imagem , Adolescente , Adulto , Estudos Transversais , Estudos de Viabilidade , Feminino , Humanos , Hipertensão/complicações , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
4.
Magn Reson Med ; 78(2): 678-688, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27579717

RESUMO

PURPOSE: Develop self-gated MRI for distinct heartbeat morphologies in subjects with arrhythmias. METHODS: Golden angle radial data was obtained in seven sinus and eight arrhythmias subjects. An image-based cardiac navigator was derived from single-shot images, distinct beat types were identified, and images were reconstructed for repeated morphologies. Image sharpness, contrast, and volume variation were quantified and compared with self-gated MRI. Images were scored for image quality and artifacts. Hemodynamic parameters were computed for each distinct beat morphology in bigeminy and trigeminy subjects and for sinus beats in patients with infrequent premature ventricular contractions. RESULTS: Images of distinct beat types were reconstructed except for two patients with infrequent premature ventricular contractions. Image contrast and sharpness were similar to sinus self-gated images (contrast = 0.45 ± 0.13 and 0.43 ± 0.15; sharpness = 0.21 ± 0.11 and 0.20 ± 0.05). Visual scoring was highest in self-gated images (4.1 ± 0.3) compared with real-time (3.9 ± 0.4) and ECG-gated cine (3.4 ± 1.5). ECG-gated cine had less artifacts than self-gating (2.3 ± 0.7 and 2.1 ± 0.2), but was affected by misgating in two subjects. Among arrhythmia subjects, post-extrasystole/sinus (58.1 ± 8.6 mL) and interrupted sinus (61.4 ± 5.9 mL) stroke volume was higher than extrasystole (32.0 ± 16.5 mL; P < 0.02). CONCLUSION: Self-gated imaging can reconstruct images during ectopy and allowed for quantification of hemodynamic function of different beat morphologies. Magn Reson Med 78:678-688, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Algoritmos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Cardiovasc Magn Reson ; 19(1): 17, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28196494

RESUMO

BACKGROUND: The evolution of T1ρ and of other endogenous contrast methods (T2, T1) in the first month after reperfused myocardial infarction (MI) is uncertain. We conducted a study of reperfused MI in pigs to serially monitor T1ρ, T2 and T1 relaxation, scar size and transmurality at 1 and 4 weeks post-MI. METHODS: Ten Yorkshire swine underwent 90 min of occlusion of the circumflex artery and reperfusion. T1ρ, T2 and native T1 maps and late gadolinium enhanced (LGE) cardiovascular magnetic resonance (CMR) data were collected at 1 week (n = 10) and 4 weeks (n = 5). Semi-automatic FWHM (full width half maximum) thresholding was used to assess scar size and transmurality and compared to histology. Relaxation times and contrast-to-noise ratio were compared in healthy and remote myocardium at 1 and 4 weeks. Linear regression and Bland-Altman was performed to compare infarct size and transmurality. RESULTS: Relaxation time differences between infarcted and remote myocardial tissue were ∆T1 (infarct-remote) = 421.3 ± 108.8 (1 week) and 480.0 ± 33.2 ms (4 week), ∆T1ρ = 68.1 ± 11.6 and 74.3 ± 14.2, and ∆T2 = 51.0 ± 10.1 and 59.2 ± 11.4 ms. Contrast-to-noise ratio was CNRT1 = 7.0 ± 3.5 (1 week) and 6.9 ± 2.4 (4 week), CNRT1ρ = 12.0 ± 6.2 and 12.3 ± 3.2, and CNRT2 = 8.0 ± 3.6 and 10.3 ± 5.8. Infarct size was not significantly different for T1ρ, T1 and T2 compared to LGE (p = 0.14) and significantly decreased from 1 to 4 weeks (p < 0.01). Individual infarct size changes were ∆T1ρ = -3.8%, ∆T1 = -3.5% and ∆LGE = -2.8% from 1 - 4 weeks, but there was no observed change in infarct size for T2 or histologically. CONCLUSIONS: T1ρ was highly correlated with alterations left ventricle (LV) pathology at 1 and 4 weeks post-MI and therefore it may be a useful method endogenous contrast imaging of infarction.


Assuntos
Cicatriz/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Reperfusão Miocárdica , Miocárdio/patologia , Animais , Biópsia , Cicatriz/patologia , Meios de Contraste/administração & dosagem , Modelos Animais de Doenças , Modelos Lineares , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Razão Sinal-Ruído , Volume Sistólico , Sus scrofa , Fatores de Tempo , Função Ventricular Esquerda
7.
J Magn Reson Imaging ; 43(3): 585-93, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26331591

RESUMO

PURPOSE: To evaluate the impact of end-diastolic (ED) and end-systolic (ES) cardiac phase selection methods, since task force recommendations have neither provided quantitative evidence nor explored errors introduced by clinical shortcuts. MATERIALS AND METHODS: Multislice, short-axis cine images were collected in 60 clinical patients on a 1.5T scanner. User-initialized active contour segmentation software quantified global left ventricular (LV) volume across all cardiac phases. Different approaches for selection of ED and ES phase were evaluated by quantification of temporal and volumetric errors. RESULTS: For diastole, the mid-ventricular maximum slice volume coincided with maximum global volume in 82.1% of patients with ejection fraction (EF) ≥55% (P = 0.66) and 71.9% of patients with EF <55% (P = 0.28) and is an accurate approximation of maximum global volume while the first and last phases in a retrospectively electrocardiogram (ECG)-gated acquisition introduced differences in cardiac phase selection (P < 0.001) which led to large errors in measured volume in some patients (12.7 and 10.1 mL, respectively). For systole, post-systolic shortening occurred in a significantly higher number of patients with EF <55% (18.9%) compared to 3.6% of patients with EF ≥55% (P = 0.001), which differentially impacted end-systolic volume estimation. CONCLUSION: For end-diastolic phase selection, our results indicated that the use of the mid-ventricular slice volume maximum provided accurate volume estimates, while selection of the first or last cardiac phase introduced differences in measured volume. For end-systolic phase, patients with EF <55% had a higher prevalence of post-systolic shortening, which suggests aortic valve closure should be used to estimate end-systolic volume.


Assuntos
Diástole , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética , Sístole , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Volume Sistólico , Função Ventricular Esquerda
8.
Magn Reson Med ; 73(2): 857-64, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24777559

RESUMO

PURPOSE: In this work, the limits of image reconstruction in k-space are explored when non-bijective gradient fields are used for spatial encoding. THEORY: The image space analogy between parallel imaging and imaging with non-bijective encoding fields is partially broken in k-space. As a consequence, it is hypothesized and proven that ambiguities can only be resolved partially in k-space, and not completely as is the case in image space. METHODS: Image-space and k-space based reconstruction algorithms for multi-channel radiofrequency data acquisitions are programmed and tested using numerical simulations as well as in vivo measurement data. RESULTS: The hypothesis is verified based on an analysis of reconstructed images. It is found that non-bijective gradient fields have the effect that densely sampled autocalibration data, used for k-space reconstruction, provide less information than a separate scan of the receiver coil sensitivity maps, used for image space reconstruction. Consequently, in k-space only the undersampling artifact can be unfolded, whereas in image space, it is also possible to resolve aliasing that is caused by the non-bijectivity of the gradient fields. CONCLUSION: For standard imaging, reconstruction in image space and in k-space is nearly equivalent, whereas there is a fundamental difference with practical consequences for the selection of image reconstruction algorithms when non-bijective encoding fields are involved.


Assuntos
Algoritmos , Artefatos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Armazenamento e Recuperação da Informação/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Langmuir ; 31(43): 11858-67, 2015 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-26446176

RESUMO

Ultrasound contrast agents are typically microbubbles (MB) with a gas core that is stabilized by a shell made of lipids, proteins, or polymers. The high impedance mismatch between the gas core and an aqueous environment produces strong contrast in ultrasound (US). Poly(lactic acid) (PLA) MB, previously developed in our laboratory, have been shown to be highly echogenic both in vitro and in vivo. Combining US with other imaging modalities such as fluorescence, magnetic resonance imaging (MRI), or computerized tomography (CT) could improve the accuracy of many US applications and provide more comprehensive diagnostic information. Furthermore, our MB have the capacity to house a drug in the PLA shell and create drug-loaded nanoparticles in situ when passing through an ultrasound beam. To create multimodal contrast agents, we hypothesized that the polymer shell of our PLA MB platform could accommodate additional payloads. In this study, we therefore modified our current MB by encapsulating nanoparticles including aqueous or organic quantum dots (QD), magnetic iron oxide nanoparticles (MNP), or gold nanoparticles (AuNP) to create bimodality platforms in a manner that minimally compromised the performance of each individual imaging technique.


Assuntos
Meios de Contraste , Imagem Multimodal , Nanopartículas/química , Polímeros/química , Animais , Linhagem Celular , Humanos , Camundongos , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Pontos Quânticos , Difração de Raios X
10.
J Cardiovasc Magn Reson ; 17: 37, 2015 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-25994390

RESUMO

BACKGROUND: Data obtained during arrhythmia is retained in real-time cardiovascular magnetic resonance (rt-CMR), but there is limited and inconsistent evidence to show that rt-CMR can accurately assess beat-to-beat variation in left ventricular (LV) function or during an arrhythmia. METHODS: Multi-slice, short axis cine and real-time golden-angle radial CMR data was collected in 22 clinical patients (18 in sinus rhythm and 4 patients with arrhythmia). A user-initialized active contour segmentation (ACS) software was validated via comparison to manual segmentation on clinically accepted software. For each image in the 2D acquisitions, slice volume was calculated and global LV volumes were estimated via summation across the LV using multiple slices. Real-time imaging data was reconstructed using different image exposure times and frame rates to evaluate the effect of temporal resolution on measured function in each slice via ACS. Finally, global volumetric function of ectopic and non-ectopic beats was measured using ACS in patients with arrhythmias. RESULTS: ACS provides global LV volume measurements that are not significantly different from manual quantification of retrospectively gated cine images in sinus rhythm patients. With an exposure time of 95.2 ms and a frame rate of > 89 frames per second, golden-angle real-time imaging accurately captures hemodynamic function over a range of patient heart rates. In four patients with frequent ectopic contractions, initial quantification of the impact of ectopic beats on hemodynamic function was demonstrated. CONCLUSION: User-initialized active contours and golden-angle real-time radial CMR can be used to determine time-varying LV function in patients. These methods will be very useful for the assessment of LV function in patients with frequent arrhythmias.


Assuntos
Arritmias Cardíacas/diagnóstico , Frequência Cardíaca , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Interface Usuário-Computador , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda , Adulto , Arritmias Cardíacas/fisiopatologia , Técnicas de Imagem de Sincronização Cardíaca , Estudos de Casos e Controles , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Software , Fatores de Tempo , Disfunção Ventricular Esquerda/fisiopatologia
11.
Sci Rep ; 14(1): 53, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167550

RESUMO

The objective of this study is to define CT imaging derived phenotypes for patients with hepatic steatosis, a common metabolic liver condition, and determine its association with patient data from a medical biobank. There is a need to further characterize hepatic steatosis in lean patients, as its epidemiology may differ from that in overweight patients. A deep learning method determined the spleen-hepatic attenuation difference (SHAD) in Hounsfield Units (HU) on abdominal CT scans as a quantitative measure of hepatic steatosis. The patient cohort was stratified by BMI with a threshold of 25 kg/m2 and hepatic steatosis with threshold SHAD ≥ - 1 HU or liver mean attenuation ≤ 40 HU. Patient characteristics, diagnoses, and laboratory results representing metabolism and liver function were investigated. A phenome-wide association study (PheWAS) was performed for the statistical interaction between SHAD and the binary characteristic LEAN. The cohort contained 8914 patients-lean patients with (N = 278, 3.1%) and without (N = 1867, 20.9%) steatosis, and overweight patients with (N = 1863, 20.9%) and without (N = 4906, 55.0%) steatosis. Among all lean patients, those with steatosis had increased rates of cardiovascular disease (41.7 vs 27.8%), hypertension (86.7 vs 49.8%), and type 2 diabetes mellitus (29.1 vs 15.7%) (all p < 0.0001). Ten phenotypes were significant in the PheWAS, including chronic kidney disease, renal failure, and cardiovascular disease. Hepatic steatosis was found to be associated with cardiovascular, kidney, and metabolic conditions, separate from overweight BMI.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Fígado Gorduroso , Hepatopatia Gordurosa não Alcoólica , Humanos , Doenças Cardiovasculares/complicações , Sobrepeso/complicações , Sobrepeso/diagnóstico por imagem , Diabetes Mellitus Tipo 2/complicações , Fígado Gorduroso/complicações , Tomografia Computadorizada por Raios X/métodos , Fenótipo , Hepatopatia Gordurosa não Alcoólica/complicações
12.
Magn Reson Med ; 67(6): 1620-32, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22127679

RESUMO

A technique is described to localize MR signals from a target volume using nonlinear pulsed magnetic fields and spatial encoding trajectories designed using local k-space theory. The concept of local k-space is outlined theoretically, and this principle is applied to simulated phantom and cardiac MRI data in the presence of surface and quadrupolar gradient coil phase modulation. Phantom and in vivo human brain images are obtained using a custom, high-performance quadrupolar gradient coil integrated with a whole-body 3-T MRI system to demonstrate target localization using three-dimensional T 2*-weighted spoiled gradient echo, two-dimensional segmented, multiple gradient encoded spin echo, and three-dimensional balanced steady-state free precession acquisitions. This method may provide a practical alternative to selective radiofrequency excitation at ultra-high-field, particularly for steady-state applications where repetition time (TR) must be minimized and when the amount of energy deposited in human tissues is prohibitive. There are several limitations to the approach including the spatial variation in resolution, high frequency aliasing artifacts, and spatial variation in echo times and contrast.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Dinâmica não Linear , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Magn Reson Imaging ; 35(4): 891-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22128105

RESUMO

PURPOSE: To determine (i) the feasibility and intra- and inter-scan reproducibility of T(1ρ) MRI in assessing cartilage degeneration in a guinea pig model with naturally occurring joint disease that closely mimics human osteoarthritis (OA), (ii) demonstrate the sensitivity of T(1ρ) MRI in assessing the age dependent cartilage degeneration in OA progression as compared to histopathological changes. MATERIALS AND METHODS: Duncan-Hartley guinea pigs were obtained at various ages and maintained under an IACUC approved protocol. The left hind stifle joint was imaged using T(1ρ) MRI on a 9.4 Tesla Varian horizontal 20 cm bore scanner using a custom surface coil. Reproducibility of T(1ρ) MRI was assessed using 4-month-old guinea pigs (N = 3). Three age cohorts; 3 month (N = 8), 5 month (N = 6), and 9 month (N = 5), were used to determine the age-dependent osteoarthritic changes as measured by T(1ρ) MRI. Validation of age-dependent cartilage degeneration was confirmed by histology and Safranin-O staining. RESULTS: T(1ρ) values obtained in the cartilage of the stifle joint in guinea pigs were highly reproducible with an inter-scan mean coefficient of variation (CV) of 6.57% and a maximum intra-scan CV of 9.29%. Mean cartilage T(1ρ) values in animals with late stage cartilage degeneration were 56.3-56.9 ms (5-9 month cohorts) were both significantly (P < 0.01) higher than that obtained from 3-month-old cohort (44 ms) demonstrating an age-dependent variation. T(1ρ) was shown to be significantly greater than T(2) . T(1ρ) dispersion was observed in this animal model for the first time showing an increase of 45% between 500 Hz and 1500 Hz spin-locking frequency. Cartilage thickness measurements were calculated from single mid-coronal histology sections from same animals used for T(1ρ) MRI. Thickness calculations showed insignificant differences between 3- and 5-month cohorts and was significantly decreased by 9 months of age (P < 0.01). A moderate correlation (R(2) = 0.45) existed between T(1ρ) values and signal intensity of Safranin-O stain. CONCLUSION: The data presented demonstrate that T(1ρ) MRI is highly reproducible in this spontaneous model of OA and may serve as a noninvasive tool to characterize joint cartilage degeneration during OA. Age-dependent changes, verified with histological measurements of proteoglycan loss, correlated with T(1ρ) across different age groups. T(1ρ) has adequate dynamic range and is sensitive to detect and track the progression of cartilage degeneration in the guinea pig model before gross anatomical changes such as cartilage thinning has occurred. This study presents a technological advancement that would permit longitudinal studies of evaluating disease-modifying therapies useful for treating human OA.


Assuntos
Cartilagem/patologia , Modelos Animais de Doenças , Imageamento por Ressonância Magnética/métodos , Osteoartrite/patologia , Animais , Cobaias , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Cardiovasc Magn Reson ; 14: 37, 2012 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-22704222

RESUMO

BACKGROUND: Late gadolinium enhanced (LGE) cardiovascular magnetic resonance (CMR) is frequently used to evaluate myocardial viability, estimate total infarct size and transmurality, but is not always straightforward is and contraindicated in patients with renal failure because of the risk of nephrogenic systemic fibrosis. T2- and T1-weighted CMR alone is however relatively insensitive to chronic myocardial infarction (MI) in the absence of a contrast agent. The objective of this manuscript is to explore T1ρ-weighted rotating frame CMR techniques for infarct characterization without contrast agents. We hypothesize that T1ρ CMR accurately measures infarct size in chronic MI on account of a large change in T1ρ relaxation time between scar and myocardium. METHODS: 7Yorkshire swine underwent CMR at 8 weeks post-surgical induction of apical or posterolateral myocardial infarction. Late gadolinium enhanced and T1ρ CMR were performed at high resolution to visualize MI. T1ρ-weighted imaging was performed with a B1 = 500 Hz spin lock pulse on a 3 T clinical MR scanner. Following sacrifice, the heart was excised and infarct size was calculated by optical planimetry. Infarct size was calculated for all three methods (LGE, T1ρ and planimetry) and statistical analysis was performed. T1ρ relaxation time maps were computed from multiple T1ρ-weighted images at varying spin lock duration. RESULTS: Mean infarct contrast-to-noise ratio (CNR) in LGE and T1ρ CMR was 2.8 ± 0.1 and 2.7 ± 0.1. The variation in signal intensity of tissues was found to be, in order of decreasing signal intensity, LV blood, fat and edema, infarct and healthy myocardium. Infarct size measured by T1ρ CMR (21.1% ± 1.4%) was not significantly different from LGE CMR (22.2% ± 1.5%) or planimetry (21.1% ± 2.7%; p < 0.05).T1ρ relaxation times were T1ρinfarct = 91.7 ms in the infarct and T1ρremote = 47.2 ms in the remote myocardium. CONCLUSIONS: T1ρ-weighted imaging using long spin locking pulses enables high discrimination between infarct and myocardium. T1ρ CMR may be useful to visualizing MI without the need for exogenous contrast agents for a wide range of clinical cardiac applications such as to distinguish edema and scar tissue and tissue characterization of myocarditis and ventricular fibrosis.


Assuntos
Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica/fisiologia , Infarto do Miocárdio/patologia , Miocárdio/patologia , Animais , Doença Crônica , Meios de Contraste/administração & dosagem , Modelos Animais de Doenças , Seguimentos , Ventrículos do Coração/fisiopatologia , Injeções Intravenosas , Imagem Cinética por Ressonância Magnética/efeitos adversos , Meglumina/administração & dosagem , Infarto do Miocárdio/fisiopatologia , Reprodutibilidade dos Testes , Suínos
16.
Front Cardiovasc Med ; 9: 867479, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35711358

RESUMO

Background: Chest radiation therapy (RT) is known to be associated with cardiotoxicity. However, the changes in myocardial tissue characterization with radiation-induced cardiotoxicity are not well-understood. Objectives: This study sought to assess the changes in left ventricular function and tissue characterization using cardiovascular magnetic resonance (CMR) in patients receiving RT. Materials and Methods: Between June 2015 and July 2018, we enrolled patients with breast, lung cancer, or lymphoma with plan to receive chest radiation after chemotherapy. CMR was performed using a 1.5T scanner at baseline and 6 months after RT. Myocardial volume, function, strain analysis using feature tracking, and tissue characterization including late gadolinium enhancement (LGE), T1, T2, T1ρ (rho), and extracellular volume fraction (ECV) were measured and compared using non-parametric methods. Results: The final cohort consisted of 16 patients, 11 of whom completed both baseline and follow-up CMRs. Patients were matched to 10 healthy controls. At baseline prior to RT, compared to controls, patients had lower global circumferential strain (GCS) (15.3 ± 2.2% vs.18.4 ± 2.1%, p = 0.004), and elevated T2 (47.9 ± 4.8 ms vs. 45.0 ± 1.5 ms, p = 0.04) and T1ρ values (78.4 ± 5.9 vs. 66.9 ± 4.6 ms, p < 0.001). Two patients had LGE. There was no significant difference in the average T1 values or ECV. There was a trend toward lower LV ejection fraction and global longitudinal strain (GLS). At 6-month follow-up after RT, there were no significant changes in all the CMR parameters. Conclusion: At 6-month following chest radiation therapy, there was no change in LV and RV EF, LV and RV GLS, LV GCS, and myocardial tissue characterization using LGE, T1, ECV, T2, and T1ρ in a small cohort of patients. However, the baseline T2 and T1ρ were elevated and LV GCS was reduced compared to controls indicating ongoing myocardial edema and subclinical dysfunction post-chemotherapy.

17.
Radiology ; 258(3): 832-42, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21212364

RESUMO

PURPOSE: To prospectively determine the reproducibility of quantitative magnetic resonance (MR) imaging biomarkers of the morphology and composition (spin lattice relaxation time in rotating frame [T1-ρ], T2) of knee cartilage in a multicenter multivendor trial involving patients with osteoarthritis (OA) and asymptomatic control subjects. MATERIALS AND METHODS: This study was HIPAA compliant and approved by the institutional review committees of the participating sites, with written informed consent obtained from all participants. Fifty subjects from five sites who were deemed to have normal knee joints (n = 18), mild OA (n = 16), or moderate OA (n = 16) on the basis of Kellgren-Lawrence scores were enrolled. Each participant underwent four sequential 3-T knee MR imaging examinations with use of the same imager and with 2-63 days (median, 18 days) separating the first and last examinations. Water-excited three-dimensional T1-weighted gradient-echo imaging, T1-ρ imaging, and T2 mapping of cartilage in the axial and coronal planes were performed. Biomarker reproducibility was determined by using intraclass correlation coefficients (ICCs) and root-mean-square coefficients of variation (RMS CVs, expressed as percentages). RESULTS: Morphometric biomarkers had high reproducibility, with ICCs of 0.989 or greater and RMS CVs lower than 4%. The largest differences between the healthy subjects and the patients with radiographically detected knee OA were those in T1-ρ values, but precision errors were relatively large. Reproducibility of T1-ρ values was higher in the thicker patellar cartilage (ICC range, 0.86-0.93; RMS CV range, 14%-18%) than in the femorotibial joints (ICC range, 0.20-0.84; RMS CV range, 7%-19%). Good to high reproducibility of T2 was observed, with ICCs ranging from 0.61 to 0.98 and RMS CVs ranging from 4% to 14%. CONCLUSION: MR imaging measurements of cartilage morphology, T2, and patellar T1-ρ demonstrated moderate to excellent reproducibility in a clinical trial network.


Assuntos
Cartilagem Articular/patologia , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/patologia , Adolescente , Adulto , Biomarcadores/análise , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Análise dos Mínimos Quadrados , Masculino , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes
18.
Magn Reson Med ; 63(5): 1376-82, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20432308

RESUMO

Nine asymptomatic subjects and six patients underwent T(1)rho MRI to determine whether Outerbridge grade 1 or 2 cartilage degeneration observed during arthroscopy could be detected noninvasively. MRI was performed 2-3 months postarthroscopy, using sagittal T(1)-weighted and axial and coronal T(1)rho MRI, from which spatial T(1)rho relaxation maps were calculated from segmented T(1)-weighted images. Median T(1)rho relaxation times of patients with arthroscopically documented cartilage degeneration and asymptomatic subjects were significantly different (P < 0.001), and median T(1)rho exceeded asymptomatic articular cartilage median T(1)rho by 2.5 to 9.2 ms. In eight observations of mild cartilage degeneration at arthroscopy (Outerbridge grades 1 and 2), mean compartment T(1)rho was elevated in five, but in all observations, large foci of increased T(1)rho were observed. It was determined that T(1)rho could detect some, but not all, Outerbridge grade 1 and 2 cartilage degeneration but that a larger patient population is needed to determine the sensitivity to these changes.


Assuntos
Algoritmos , Artroscopia , Doenças das Cartilagens/patologia , Cartilagem/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Magn Reson Med ; 64(5): 1453-60, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20677236

RESUMO

T1ρ relaxation times were quantified in a swine model of chronic, left ventricular myocardial infarction. It was found that there were low frequency relaxation mechanisms that suppress endogenous contrast at low spin-lock amplitudes and in T2-weighted images. A moderate amplitude spin-locking pulse could overcome these relaxation mechanisms. Relaxation dispersion data were measured over a range of RF field amplitudes, and a model was formulated to include dipole-dipole relaxation modulated by molecular rotation and an apparent exchange mechanism. These techniques may find some use in the clinic for the observation of chronic, left ventricular cardiac remodeling.


Assuntos
Algoritmos , Modelos Animais de Doenças , Interpretação de Imagem Assistida por Computador/métodos , Infarto do Miocárdio/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Animais , Humanos , Aumento da Imagem/métodos , Infarto do Miocárdio/complicações , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade , Marcadores de Spin , Suínos
20.
PLoS One ; 15(12): e0244286, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33373391

RESUMO

BACKGROUND: Segmented cine cardiac MRI combines data from multiple heartbeats to achieve high spatiotemporal resolution cardiac images, yet predefined k-space segmentation trajectories can lead to suboptimal k-space sampling. In this work, we developed and evaluated an autonomous and closed-loop control system for radial k-space sampling (ARKS) to increase sampling uniformity. METHODS: The closed-loop system autonomously selects radial k-space sampling trajectory during live segmented cine MRI and attempts to optimize angular sampling uniformity by selecting views in regions of k-space that were not previously well-sampled. Sampling uniformity and the ability to detect cardiac phase in vivo was assessed using ECG data acquired from 10 normal subjects in an MRI scanner. The approach was then implemented with a fast gradient echo sequence on a whole-body clinical MRI scanner and imaging was performed in 4 healthy volunteers. The closed-loop k-space trajectory was compared to random, uniformly distributed and golden angle view trajectories via measurement of k-space uniformity and the point spread function. Lastly, an arrhythmic dataset was used to evaluate a potential application of the approach. RESULTS: The autonomous trajectory increased k-space sampling uniformity by 15±7%, main lobe point spread function (PSF) signal intensity by 6±4%, and reduced ringing relative to golden angle sampling. When implemented, the autonomous pulse sequence prescribed radial view angles faster than the scan TR (0.98 ± 0.01 ms, maximum = 1.38 ms) and increased k-space sampling mean uniformity by 10±11%, decreased uniformity variability by 44±12%, and increased PSF signal ratio by 6±6% relative to golden angle sampling. CONCLUSION: The closed-loop approach enables near-uniform radial sampling in a segmented acquisition approach which was higher than predetermined golden-angle radial sampling. This can be utilized to increase the sampling or decrease the temporal footprint of an acquisition and the closed-loop framework has the potential to be applied to patients with complex heart rhythms.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Algoritmos , Feminino , Voluntários Saudáveis , Coração/fisiologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino
SELEÇÃO DE REFERÊNCIAS