Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Diabetes Obes Metab ; 26(6): 2267-2274, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38479807

RESUMO

AIMS: To examine the effects of a home-based exergame training over 6 weeks on cardio-metabolic and cognitive health, as well as training adherence, in physically inactive individuals. MATERIALS AND METHODS: Twenty participants were equipped with an exergame system specifically designed for use at home. Each participant performed at least three weekly exercise sessions at ≥80% of their individual maximum heart rate, over 6 weeks. Exercise duration increased biweekly until 75 min of vigorous exercise were performed in Weeks 5 and 6. Maximum oxygen uptake (VO2max), cardio-metabolic profiling, and neuro-cognitive tests were performed at baseline and study end. Additionally, training adherence was assessed via training diaries. RESULTS: After 6 weeks of home-based exergaming, VO2max increased significantly, while there was a significant decrease in heart rate (resting and maximum), blood pressure (systolic, diastolic and mean), and low-density lipoprotein cholesterol. Dynamic balance and reaction time improved after 6 weeks of exergaming. Training adherence was 88.4%. CONCLUSIONS: Home-based exergaming induced a clinically relevant increase in VO2max, a determinant of cardiovascular health, accompanied by further improvements in cardiovascular, metabolic and neuro-cognitive parameters. Exergaming may, therefore, offer an innovative approach to increasing regular physical activity, improving metabolic risk profile, and preventing chronic diseases.


Assuntos
Cognição , Exercício Físico , Frequência Cardíaca , Consumo de Oxigênio , Jogos de Vídeo , Humanos , Masculino , Feminino , Adulto , Cognição/fisiologia , Frequência Cardíaca/fisiologia , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Exercício Físico/fisiologia , Comportamento Sedentário , Terapia por Exercício/métodos , Pressão Sanguínea/fisiologia , Cooperação do Paciente
2.
Diabetes Technol Ther ; 26(4): 263-275, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38194227

RESUMO

Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC) that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively, and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels are suggested that enable the collection of comparator data with these characteristics. This work is an important step toward establishing a future standard for the performance evaluation of CGM systems.


Assuntos
Glicemia , Hiperglicemia , Humanos , Automonitorização da Glicemia/métodos , Monitoramento Contínuo da Glicose , Hiperglicemia/diagnóstico , Hiperglicemia/prevenção & controle
3.
Sci Rep ; 13(1): 14782, 2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37679415

RESUMO

Oxygenation is a crucial indicator of tissue viability and function. Oxygen tension ([Formula: see text]), i.e. the amount of molecular oxygen present in the tissue is a direct result of supply (perfusion) and consumption. Thus, measurement of [Formula: see text] is an effective method to monitor tissue viability. However, tissue oximetry sensors commonly used in clinical practice instead rely on measuring oxygen saturation ([Formula: see text]), largely due to the lack of reliable, affordable [Formula: see text] sensing solutions. To address this issue we present a proof-of-concept design and validation of a low-cost, lifetime-based oxygen sensing fiber. The sensor consists of readily-available off-the shelf components such as a microcontroller, a light-emitting diode (LED), an avalanche photodiode (APD), a temperature sensor, as well as a bright in-house developed porphyrin molecule. The device was calibrated using a benchtop setup and evaluated in three in vivo animal models. Our findings show that the new device design in combination with the bright porphyrin has the potential to be a useful and accurate tool for measuring [Formula: see text] in tissue, while also highlighting some of the limitations and challenges of oxygen measurements in this context.


Assuntos
Tecnologia de Fibra Óptica , Porfirinas , Animais , Gasometria , Oximetria , Oxigênio
4.
J Diabetes Sci Technol ; 17(6): 1506-1526, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37599389

RESUMO

The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Humanos , Automonitorização da Glicemia/métodos
5.
ACS Sens ; 6(1): 43-53, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33325684

RESUMO

Measurement of intramuscular oxygen could play a key role in the early diagnosis of acute compartment syndrome, a common condition occurring after severe trauma leading to ischemia and long-term consequences including rhabdomyolysis, limb loss, and death. However, to date, there is no existing oxygen sensor approved for such a purpose. To address the need to improve the assessment of compartment syndrome, a portable fiber-optic device for intramuscular oxygen measurements was developed. The device is based on phosphorescence quenching, where the tip of an optical fiber was coated with a poly(propyl methacrylate) (PPMA) matrix containing a brightly emitting Pt(II)-core porphyrin. The optoelectronic circuit is highly portable and is based on a microspectrometer and a microcontroller readout with a smartphone. Results from an in vivo tourniquet porcine model show that the sensor is sensitive across the physiological oxygen partial pressure range of 0-80 mmHg and exhibits an appropriate and reproducible response to changes in intramuscular oxygen. A commercial laboratory oxygen sensor based on a lifetime measurement did not respond as expected.


Assuntos
Síndromes Compartimentais , Oxigênio , Animais , Hipóxia , Fibras Ópticas , Suínos
6.
Biomed Opt Express ; 11(12): 6989-7002, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33408975

RESUMO

Wearable devices have found widespread applications in recent years as both medical devices as well as consumer electronics for sports and health tracking. A metric of health that is often overlooked in currently available technology is the direct measurement of molecular oxygen in living tissue, a key component in cellular energy production. Here, we report on the development of a wireless wearable prototype for transcutaneous oxygenation monitoring based on quantifying the oxygen-dependent phosphorescence of a metalloporphyrin embedded within a highly breathable oxygen sensing film. The device is completely self-contained, weighs under 30 grams, performs on-board signal analysis, and can communicate with computers or smartphones. The wearable measures tissue oxygenation at the skin surface by detecting the lifetime and intensity of phosphorescence, which undergoes quenching in the presence of oxygen. As well as being insensitive to motion artifacts, it offers robust and reliable measurements even in variable atmospheric conditions related to temperature and humidity. Preliminary in vivo testing in a porcine ischemia model shows that the wearable is highly sensitive to changes in tissue oxygenation in the physiological range upon inducing a decrease in limb perfusion.

7.
Transl Vis Sci Technol ; 7(4): 2, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30002949

RESUMO

PURPOSE: Feasibility testing of a novel volume renders technology to display optical coherence tomography data (OCT) in a virtual reality (VR) environment. METHODS: A VR program was written in C++/OpenGL to import and display volumetric OCT data in real time with 180 frames per second using a high-end computer and a tethered head-mounted display. Following exposure, participants completed a Simulator Sickness Questionnaire (SSQ) to assess for nausea, disorientation, and oculomotor disturbances. A user evaluation study of this software was conducted to explore the potential utility of this application. RESULTS: Fifty-seven subjects completed the user testing (34 males and 23 females). Mean age was 48.5 years (range, 21-77 years). Mean acquired work experience of the 35 ophthalmologists (61.40%) included in the group was 15.46 years (range, 1-37 years). Twenty-nine participants were VR-naïve. The SSQ showed a mean total score of 5.8 (SD = 9.44) indicating that the system was well tolerated and produced minimal side effects. No difference was reported between VR-naïve participants and experienced users. Overall, immersed subjects reported an enjoyable VR-OCT presence effect. CONCLUSIONS: A usable and satisfying VR imaging technique was developed to display and interact with original OCT data. TRANSLATIONAL RELEVANCE: An advanced high-end VR image display method was successfully developed to provide new views and interactions in an ultra high-speed projected digital scenery using point-cloud OCT data. This represents the next generation of OCT image display technology and a new tool for patient engagement, medical education, professional training, and telecommunications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA