1.
Anal Bioanal Chem ; 401(7): 2093-102, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21643859

RESUMO

Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in an increased CO on propofol breath concentrations and on the correlation between propofol blood and breath concentrations were investigated in seven acutely instrumented pigs. Discontinuous propofol determination in breath by means of alveolar sampling and SPME-GC-MS showed good agreement (R(2)=0.959) with continuous alveolar real-time measurement by means of PTR-MS. In all investigated animals, increasing cardiac output led to a deterioration of the relationship between breath and blood propofol concentrations (R(2)=0.783 for gas chromatography-mass spectrometry and R(2)=0.795 for PTR-MS). Decreasing pulmonary blood flow and cardiac output through banding of the pulmonary artery did not significantly affect the relationship between propofol breath and blood concentrations (R(2)>0.90). Estimation of propofol blood concentrations from exhaled alveolar concentrations seems possible by means of different analytical methods even when cardiac output is decreased. Increases in cardiac output preclude prediction of blood propofol concentration from exhaled concentrations.


Assuntos
Anestésicos Intravenosos/análise , Testes Respiratórios , Débito Cardíaco/efeitos dos fármacos , Expiração , Propofol/análise , Circulação Pulmonar/efeitos dos fármacos , Animais , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Hemodinâmica , Masculino , Suínos
2.
Int J Radiat Oncol Biol Phys ; 107(4): 683-693, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32437921

RESUMO

PURPOSE: After publication of the radiation field design in the American College of Surgeons Oncology Group Z0011 trial, a radiation therapy quality assurance review was integrated into the Intergroup-Sentinel-Mamma (INSEMA) trial. We aimed to investigate the role of patient characteristics, extent of axillary surgery, and radiation techniques for dose distribution in ipsilateral axillary levels. METHODS AND MATERIALS: INSEMA (NCT02466737) has randomized 5542 patients who underwent breast-conserving surgery. Of these, 276 patients from 108 radiation therapy facilities were included in the central review, using the planning records of the first 3 patients treated at each site. RESULTS: Of the 276 patients, 41 had major deviations (ie, no axillary contouring or submission of insufficient records) leading to exclusion. A total of 235 (85.1%) radiation therapy planning records were delineated according to the INSEMA protocol, including 9 (3.8%) cases with minor deviations. At least 25% of INSEMA patients were unintentionally treated with ≥95% of the prescribed breast radiation dose in axillary level I. Approximately 50% of patients were irradiated with a median radiation dose of more than 85% of prescription dose in level I. Irradiated volumes and applied doses were significantly lower in levels II and III compared with level I. However, 25% of patients still received a median radiation dose of ≥75% of prescription dose to level II. Subgroup analysis revealed a significant association between incidental radiation dose in the axilla and obesity. Younger age, boost application, and fractionation schedule showed no impact on axillary dose distribution. CONCLUSIONS: Assuming ≥80% of prescribed breast dose as the optimal dose for curative radiation of low-volume disease in axillary lymph nodes, at least 50% of reviewed INSEMA patients received an adequate dose in level I, even with contemporary 3-dimensional techniques. Dose coverage was much less in axillary levels II and III, and far below therapeutically relevant doses.


Assuntos
Ensaios Clínicos como Assunto , Mastectomia Segmentar , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Controle de Qualidade