Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 17(4)2017 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-28430127

RESUMO

We present an image-guided laparoscopic surgical tool (IGLaST) to prevent bleeding. By applying optical frequency domain imaging (OFDI) to a specially designed laparoscopic surgical tool, the inside of fatty tissue can be observed before a resection, and the presence and size of blood vessels can be recognized. The optical sensing module on the IGLaST head has a diameter of less than 390 µm and is moved back and forth by a linear servo actuator in the IGLaST body. We proved the feasibility of IGLaST by in vivo imaging inside the fatty tissue of a porcine model. A blood vessel with a diameter of about 2.2 mm was clearly observed. Our proposed scheme can contribute to safe surgery without bleeding by monitoring vessels inside the tissue and can be further expanded to detect invisible nerves of the laparoscopic thyroid during prostate gland surgery.


Assuntos
Laparoscopia , Animais , Imagem Óptica , Suínos , Tomografia de Coerência Óptica
2.
Sensors (Basel) ; 16(1)2016 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-26805840

RESUMO

We have developed a modified optical frequency domain imaging (OFDI) system that performs parallel imaging of three-dimensional (3D) surface profiles by using the space division multiplexing (SDM) method with dual-area swept sourced beams. We have also demonstrated that 3D surface information for two different areas could be well obtained in a same time with only one camera by our method. In this study, double field of views (FOVs) of 11.16 mm × 5.92 mm were achieved within 0.5 s. Height range for each FOV was 460 µm and axial and transverse resolutions were 3.6 and 5.52 µm, respectively.

3.
J Opt Soc Am A Opt Image Sci Vis ; 28(10): 2026-32, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21979507

RESUMO

The analog mean-delay (AMD) method is a new alternative method to measure the lifetime of a fluorescence molecule. Because of its powerful advantages of accurate lifetime determination, good photon economy, and a high photon detection rate, the AMD method is considered to be very suitable for high-speed confocal fluorescence lifetime imaging microscopy (FLIM). For the practical usage of the AMD method in FLIM (AMD-FLIM), detailed study on various experimental conditions and parameters that affect the precision and the accuracy of the AMD method is required. In this paper, we present the relation between the precision and accuracy of the lifetime versus iteration number in the AMD method, the best cutoff frequency of a low-pass filter used in the AMD-FLIM system for a given fluorophore, and the optimum position and width of the integration window by using Monte Carlo simulations and a series of AMD-FLIM experiments.

4.
J Opt Soc Am A Opt Image Sci Vis ; 27(11): 2402-10, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21045905

RESUMO

The analog mean-delay (AMD) method is a new powerful alternative method in determining the lifetime of a fluorescence molecule for high-speed confocal fluorescence lifetime imaging microscopy. Even though the photon economy and the lifetime precision of the AMD method are proven to be as good as those of the state-of-the-art time-correlated single photon counting method, there have been some speculations and concerns about the accuracy of this method with respect to the absolute lifetime value of a fluorescence probe. In the AMD method, the temporal waveform of an emitted fluorescence signal is directly recorded with a slow digitizer whose bandwidth is much lower than the temporal resolution of the lifetime to be measured. We have found that the drifts and the fluctuations of the absolute zero position in a measured temporal waveform are the major problems in the AMD method. We have proposed electrical and optical referencing techniques that may suppress these errors. It is shown that there may exist more than 2 ns drift in a measured temporal waveform during the period of the first 12 min after electronic components are turned on. The standard deviation of a measured lifetime after this warm-up period can be as large as 51 ps without any referencing technique. We have shown that this error can be reduced to 9 ps with our electronic referencing technique. It is demonstrated that this can be further reduced to 4 ps by the optical referencing technique we have introduced.


Assuntos
Microscopia de Fluorescência/métodos , Microscopia de Fluorescência/normas , Equipamentos e Provisões Elétricas , Microscopia de Fluorescência/instrumentação , Fenômenos Ópticos , Padrões de Referência , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA