Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
Exp Physiol ; 109(2): 255-270, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37975151

RESUMO

Women continue to be under-represented in thermoregulatory research despite their undergoing unique physiological changes across the lifespan. This study investigated the biophysical, thermo-physiological, and perceptual determinants of cool-seeking behaviour during exercise in younger and older women. Eleven younger (25 ± 5 years; 1.7 ± 0.1 m; 63.1 ± 5.2 kg) and 11 older women (53 ± 6 years; 1.7 ± 0.1 m; 65.4 ± 13.9 kg) performed a 40-min incremental cycling test in a thermoneutral environment (22 ± 1.7°C; 36 ± 4% relative humidity). Throughout the test, participants freely adjusted the temperature of a cooling probe applied to their wrists to offset their thermal discomfort. We continuously recorded the probe-wrist interface temperature to quantify participants' cool-seeking behaviour. We also measured changes in participants' rate of metabolic heat production, core and mean skin temperatures, and skin wetness. Finally, we body-mapped participants' skin heat, cold and wetness sensitivity. Our results indicated that: (1) older and younger women exhibited similar onset and magnitude of cool-seeking behaviour, despite older women presented reduced autonomic heat-dissipation responses (i.e., whole-body sweat losses); (2) older women's thermal behaviour was less determined by changes in core temperature (this being a key driver in younger women), and more by changes in multiple thermo-physiological and biophysical parameters (i.e., physical skin wetness, temperature and heat production); (3) older women did not present lower regional skin thermal and wetness sensitivity than younger women. We conclude that predictions of female cool-seeking behaviours based on thermo-physiological variables should consider the effects of ageing. These findings are relevant for the design of wearable cooling systems and sports garments that meet the thermal needs of women across the lifespan.


Assuntos
Regulação da Temperatura Corporal , Exercício Físico , Humanos , Feminino , Idoso , Regulação da Temperatura Corporal/fisiologia , Exercício Físico/fisiologia , Temperatura Cutânea , Sudorese , Pele , Temperatura Alta
2.
Exp Physiol ; 109(8): 1330-1340, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38847458

RESUMO

Female development includes significant morphological changes across the breast. Yet, whether differences in breast surface area (BrSA) modify sweat gland density and output remains unclear. The present study investigated the relationship between BrSA and sweat gland density and output in 22 young to middle-aged women (28 ± $\ \pm \ $ 10 years) of varying breast sizes (BrSA range: 147-561 cm2) during a submaximal run in a warm environment (32  ± $ \pm \ $ 0.6°C; 53  ± $ \pm \ $ 1.7% relative humidity). Local sweat gland density and local sweat rate (LSR) above and below the nipple and at the bra triangle were measured. Expired gases were monitored for the estimation of evaporative requirements for heat balance (Ereq, in W/m2). Associations between BrSA and (i) sweat gland density; (ii) LSR; and (iii) sweat output per gland for the breast sites were determined via correlation and regression analyses. Our results indicated that breast sweat gland density decreased linearly as BrSA increased (r = -0.76, P < 0.001), whereas sweat output per gland remained constant irrespective of BrSA (r = 0.29, P = 0.28). This resulted in LSR decreasing linearly as BrSA increased (r = -0.62, P = 0.01). Compared to the bra triangle, the breast had a 64% lower sweat gland density (P < 0.001), 83% lower LSR (P < 0.001) and 53% lower output per gland (P < 0.001). BrSA (R2 = 0.33, P = 0.015) explained a greater proportion of variance in LSR than Ereq (in W/m2) (R2 = 0.07, P = 0.538). These novel findings extend the known relationship between body morphology and sweat gland density and LSR, to the female breast. This knowledge could innovate user-centred design of sports bras by accommodating breast size-specific needs for sweat management, skin wetness perception and comfort.


Assuntos
Mama , Temperatura Alta , Glândulas Sudoríparas , Sudorese , Humanos , Feminino , Adulto , Sudorese/fisiologia , Glândulas Sudoríparas/fisiologia , Mama/fisiologia , Adulto Jovem , Regulação da Temperatura Corporal/fisiologia
3.
Exp Physiol ; 109(10): 1698-1709, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39173060

RESUMO

Female development includes significant morphological changes across the breast. Yet, whether differences in breast surface area (BrSA) modify breast skin stiffness and tactile sensitivity at rest and after exercise in the heat remain unclear. We investigated the relationship between BrSA and skin stiffness and tactile sensitivity in 20 young to middle-aged women (27 ± 8 years of age) of varying breast sizes (BrSA range: 147-502 cm2) at rest and after a submaximal run in a warm climatic chamber (32 C ${\mathrm{C}}$  ±  0 . 6 C ; ${\mathrm{0}}{\mathrm{.6C;}}$ 53% ± 1.7% relative humidity). Skin stiffness above and below the nipple and tactile sensitivity from the nipple down were measured. Associations between BrSA and both skin stiffness and tactile sensitivity at rest were determined via correlation analyses. Effects of exercise and test site were assessed by a two-way ANOVA. Skin stiffness was positively correlated with BrSA 3 cm above the areola edge (r = 0.61, P = 0.005) and at the superior areola border (r = 0.54, P = 0.016), but not below the nipple (P > 0.05). The area 3 cm below the areola was also significantly stiffer than all other test sites (P < 0.043). Tactile sensitivity did not vary with BrSA (P > 0.09), but it varied across the breast (i.e., the area 3 cm below the areola was more sensitive than the inferior areola edge; P = 0.018). Skin stiffness and tactile sensitivity across the breast decreased after exercise by ∼37% (P < 0.001) and ∼45% (P = 0.008), respectively. These findings expand our fundamental understanding of the mechanosensory properties of the female breast, and they could help to inform sportswear innovation to better meet the support needs of women of different breast sizes at rest and following exercise.


Assuntos
Mama , Exercício Físico , Temperatura Alta , Descanso , Tato , Humanos , Feminino , Adulto , Exercício Físico/fisiologia , Mama/fisiologia , Adulto Jovem , Descanso/fisiologia , Tato/fisiologia , Fenômenos Fisiológicos da Pele , Pele
4.
Skin Res Technol ; 30(7): e13830, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38951871

RESUMO

BACKGROUND: Consumer products such as electrical shavers exert a combination of dynamic loading in the form of pressure and shear on the skin. This mechanical stimulus can lead to discomfort and skin tissue responses characterised as "Skin Sensitivity". To minimise discomfort following shaving, there is a need to establish specific stimulus-response relationships using advanced tools such as optical coherence tomography (OCT). OBJECTIVE: To explore the spatial and temporal changes in skin morphology and microvascular function following an electrical shaving stimulus. METHODS: Ten healthy male volunteers were recruited. The study included a 60-s electrical shaving stimulus on the forearm, cheek and neck. Skin parameters were recorded at baseline, 20 min post stimulus and 24 h post stimulus. Structural and dynamic skin parameters were estimated using OCT, while transepidermal water loss (TEWL) was recorded to provide reference values for skin barrier function. RESULTS: At baseline, six of the eight parameters revealed statistically significant differences between the forearm and the facial sites, while only surface roughness (Rq) and reflectivity were statistically different (p < 0.05) between the cheek and neck. At 20 min post shaving, there was a significant increase in the TEWL values accompanied by increased blood perfusion, with varying magnitude of change dependent on the anatomical site. Recovery characteristics were observed 24 h post stimulus with most parameters returning to basal values, highlighting the transient influence of the stimulus. CONCLUSIONS: OCT parameters revealed spatial and temporal differences in the skin tissue response to electrical shaving. This approach could inform shaver design and prevent skin sensitivity.


Assuntos
Pele , Tomografia de Coerência Óptica , Humanos , Masculino , Tomografia de Coerência Óptica/métodos , Adulto , Pele/irrigação sanguínea , Pele/diagnóstico por imagem , Antebraço/irrigação sanguínea , Adulto Jovem , Microvasos/diagnóstico por imagem , Microvasos/fisiologia , Bochecha/irrigação sanguínea , Bochecha/diagnóstico por imagem , Perda Insensível de Água/fisiologia , Voluntários Saudáveis , Fenômenos Fisiológicos da Pele , Estimulação Elétrica , Pescoço/diagnóstico por imagem , Pescoço/irrigação sanguínea , Microcirculação/fisiologia
5.
J Tissue Viability ; 2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39084958

RESUMO

AIM: Individuals in the community with reduced mobility are at risk of exposure to prolonged lying and sitting postures, which may cause pressure ulcers. The present study combines continuous pressure monitoring technology and intelligent algorithms to evaluate posture, mobility, and pressure profiles in a cohort of community dwelling patients, who had acquired pressure ulcers. MATERIALS AND METHODS: This study represents a secondary analysis of the data from the Quality Improvement project 'Pressure Reduction through COntinuous Monitoring In the community SEtting (PROMISE)'. 22 patients with pressure ulcers were purposely selected from 105 recruited community residents. Data were collected using a commercial continuous pressure monitoring system over a period of 1-4 days, and analysed with an intelligent algorithm using machine learning to determine posture and mobility events. Duration and magnitude of pressure signatures of each static posture and exposure thresholds were identified based on a sigmoid relationship between pressure and time. RESULTS: Patients revealed a wide range of ages (30-95 years), BMI (17.5-47 kg/m2) and a series of co-morbidities, which may have influenced the susceptibility to skin damage. Posture, mobility, and pressure data revealed a high degree of inter-subject variability. Largest duration of static postures ranged between 1.7 and 19.8 h, with 17/22 patients spending at least 60 % of their monitoring period in static postures which lasted >2 h. Data revealed that many patients spent prolonged periods with potentially harmful interface pressure conditions, including pressure gradients >60 mmHg/cm. CONCLUSION: This study combined posture, mobility, and pressure data from a commercial pressure monitoring technology through an intelligent algorithm. The community residents who had acquired a pressure ulcer at the time of monitoring exhibited trends which exposed their skin and subdermal tissues to prolonged high pressures during static postures. These indicators need further validation through prospective clinical trials.

6.
J Tissue Viability ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39232983

RESUMO

AIM: Pressure-ulcer occurrence in the seated patient is understudied. Preventative devices have been developed and are prescribed commonly, but there is little quantitative evidence of their effectiveness. This study explores the concept of a lateral pressure device, a prevention device that applies pressure to the sides of the seated buttocks, to reduce the amount of tissue distortion and blood-vessel occlusion. It is hypothesized that this device will reduce deep tissue injury by reducing the pressure at the bone-muscle interface, as demonstrated computationally in previous research. This study aimed to use oximetry to investigate the efficacy of the device in maintaining transcutaneous gas tensions of the tissue as close to baseline as possible. METHODS: Oximetry electrodes were attached to participants' ischial tuberosity and greater trochanter for different amounts of lateral pressure. The amount of lateral pressure is a given percentage of the pressure due to the participants' underbody pressure. RESULTS: The results show that 50 % lateral pressure is sufficient to produce an improvement in participants' gas tensions at their ischial tuberosity, without negatively impacting the tissue at their greater trochanter, relative to the control of sitting with no application of lateral pressure. CONCLUSION: Despite a rudimentary prototype device design, and that participants each placed their own oximetry sensors, results support the application of lateral pressure as a method to maintain transcutaneous gas tensions. Further work should be carried out on a larger sample to consolidate these findings.

7.
Skin Res Technol ; 29(1): e13239, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36382670

RESUMO

BACKGROUND: Personal protective equipment, including respirator devices, has been used to protect healthcare workers (HCWs) during the COVID-19 pandemic. These are fitted to skin sites on the face to prevent airborne transmission but have resulted in reports of discomfort and adverse skin reactions from their continued usage. The present study addresses the objective changes in both the structural integrity and biological response of the skin following prolonged and consecutive use of respirators. MATERIALS AND METHODS: A longitudinal cohort study, involving 17 HCWs who wear respirators daily, was designed. Changes in the barrier properties and biological response of the skin were assessed at three facial anatomical sites, namely, the nasal bridge, left cheek and at a location outside the perimeter of respirator. Assessments were made on three different sessions corresponding to the first, second and third consecutive days of mask usage. Skin parameters included transepidermal water loss (TEWL), stratum corneum (SC) hydration and erythema, as well as cytokine biomarkers sampled from sebum using a commercial tape. RESULTS: The cheek and the site outside the perimeter covered by the respirator presented minimal changes in skin parameters. By contrast, significant increases in both the TEWL (up to 4.8 fold) and SC hydration (up to 2.7 fold) were detected at the nasal bridge on the second consecutive day of respirator-wearing. There was a high degree of variation in the individual expression of pro-and anti-inflammatory cytokines. Increasing trends in nasal bridge TEWL values were associated with the body mass index (p < 0.05). CONCLUSIONS: The most sensitive objective parameter in detecting changes in the skin barrier proved to be the increase in TEWL at the nasal bridge, particularly on the second day of consecutive respirator usage. By contrast, other measures of skin were less able to detect remarkable variations in the barrier integrity. Consideration for protecting skin health is required for frontline workers, who continue to wear respirators for prolonged periods over consecutive days during the pandemic.


Assuntos
COVID-19 , Humanos , COVID-19/prevenção & controle , Pandemias/prevenção & controle , Estudos Longitudinais , Água , Ventiladores Mecânicos , Pessoal de Saúde , Atenção à Saúde
8.
Skin Res Technol ; 29(2): e13292, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36823505

RESUMO

BACKGROUND: Skin is the largest organ in the body, representing an important interface to monitor health and disease. However, there is significant variation in skin properties for different ages, genders and body regions due to the differences in the structure and morphology of the skin tissues. This study aimed to evaluate the use of non-invasive tools to discriminate a range of mechanical and functional skin parameters from different skin sites. MATERIALS AND METHODS: A cohort of 15 healthy volunteers was recruited following appropriate informed consent. Four well-established CE-marked non-invasive techniques were used to measure four anatomical regions: palm, forearm, sole and lower lumbar L3, using a repeated measures design. Skin parameters included trans-epidermal water loss (TEWL), pH (acidity), erythema, stratum corneum hydration and stiffness and elasticity using Myoton Pro (skin and muscle probe). Differences between body locations for each parameter and the intra-rater reliability between days were evaluated by the same operator. RESULTS: The results indicate that parameters differed significantly between skin sites. For the Myoton skin probe, the sole recorded the highest stiffness value of 1006 N/m (SD ± 179), while the lower lumbar recorded the least value of 484 N/m (SD ± 160). The muscle indenter Myoton probe revealed the palm's highest value of 754 N/m (± 108), and the lower lumbar recorded the least value of 208 N/m (SD ± 44). TEWL values were lowest on the forearm, averaging 11 g/m2/h, and highest on the palm, averaging 41 g/m2/h. Similar skin hydration levels were recorded in three of the four sites, with the main difference being observed in the sole averaging 13 arbitrary units. Erythema values were characterised by a high degree of inter-subject variation, and no significant differences between sites or sides were observed. The Myoton Pro Skin showed excellent reliability (intra-class correlation coefficients > 0.70) for all sites with exception of one site right lower back; the Myoton pro muscle probes showed good to poor reliability (0.90-017), the corneometer showed excellent reliability (>0.75) among all the sites tested, and the TEWL showed Good to poor reliability (0.74-0.4) among sites. CONCLUSION: The study revealed that using non-invasive methods, the biophysical properties of skin can be mapped, and significant differences in the mechanical and functional properties of skin were observed. These parameters were reliably recorded between days, providing a basis for their use in assessing and monitoring changes in the skin during health and disease.


Assuntos
Fenômenos Fisiológicos da Pele , Pele , Humanos , Feminino , Masculino , Reprodutibilidade dos Testes , Pele/metabolismo , Epiderme , Eritema , Água/metabolismo , Perda Insensível de Água/fisiologia
9.
Spinal Cord ; 61(2): 111-118, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35978113

RESUMO

STUDY DESIGN: Cohort observational study. OBJECTIVES: To examine the movement profiles of individuals with spinal cord injury (SCI) during their inpatient rehabilitative phase using continuous pressure monitoring (CPM), evaluating the trends in those with skin damage. SETTING: SCI specialist rehabilitation centre in the United Kingdom. METHODS: Individuals with SCI (n = 12) were assessed using CPM in the bed and chair over a 24-72 h. Pressure data was used as a surrogate for movement using both nursing interpretation and an intelligent algorithm. Clinical features were obtained including participants age, injury level, ASIA score, co-morbidities and prescribed support surfaces. Trends between movement profiles (frequency and intervals), SCI demographics and observed skin damage were assessed using cross-tabulation and histograms. RESULTS: The data revealed significant correlations (p < 0.05) between the nursing observation and algorithm for predicting movement, although the algorithm was more sensitive. Individuals with high level injuries (C1-T6) were observed to have a lower frequency of movement and larger intervals between movements when compared to low level injuries (T7-L5) during both lying and sitting periods. The individuals observed to have skin damage were predominantly those who had both a low frequency of movement and extended gaps between movements. CONCLUSIONS: Movements for pressure relief in both the bed and chair environments were dependent on the level of injury in individuals with SCI during their inpatient rehabilitation. Distinct movement patterns corresponded with those who acquired skin damage, revealing the potential clinical applications for technologies to monitor PU risk and inform personalised care.


Assuntos
Úlcera por Pressão , Traumatismos da Medula Espinal , Humanos , Úlcera por Pressão/etiologia , Pacientes Internados , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/reabilitação , Estudos de Coortes
10.
Skin Pharmacol Physiol ; 36(1): 38-50, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36572004

RESUMO

INTRODUCTION: Proteins, such as cytokines and chemokines, are present in varying concentrations in a range of biofluids, with an important signalling role in maintaining homeostasis. Commercial tapes have been employed to non-invasively collect these potential biomarkers in sebum from the skin surface to examine their concentrations in conditions including acne, atopic dermatitis, and pressure ulcers. However, the identification of robust biomarker candidates is limited by the low abundance of specific proteins extracted by current methodologies. Therefore, this study was designed to develop an optimized extraction method for potential inflammatory biomarkers in sebum collected with Sebutapes. METHODS: Commercial tapes (Sebutapes) coated with synthetic sebum were used to systematically evaluate the effects of chemical and mechanical stimuli on extraction efficiency. Varying concentrations of high- and low-abundance biomarkers (IL-1α, IL-6, IL-8, INF-γ, TNF-α, and IL-1RA) were used to spike the synthetic sebum samples. Methodological variables included different surfactants, mechanical stimuli, and buffer volume. Extraction efficiency was estimated using immunoassay kits from the extracted buffer. RESULTS: The results revealed that the use of a surfactant, i.e., ß-dodecyl maltoside, in addition to the mechanical stimuli, namely, sonication and centrifugation, resulted in an increased recovery of cytokines, ranging from 80% for high-abundant cytokines, such as IL-1α and IL-1RA, and up to 50% for low-abundance cytokines, including TNF-α, IL-6 and IL-8. Compared to previous methods, the new extraction protocol resulted in between a 1.5-2.0-fold increase in extraction efficiency. CONCLUSION: The study revealed that there was a high degree of variability in the extraction efficiency of different cytokines. However, improved efficiency was achieved across all cytokines with selective surfactants and mechanical stimuli. The optimised protocol will provide means to detect low levels of potential biomarkers from skin surface, enabling the evaluation of local changes in pro- and anti-inflammatory cytokines present in different skin conditions.


Assuntos
Biomarcadores , Extração Líquido-Líquido , Sebo , Biomarcadores/química , Biomarcadores/metabolismo , Citocinas/metabolismo , Proteína Antagonista do Receptor de Interleucina 1/metabolismo , Interleucina-6/metabolismo , Interleucina-8/metabolismo , Sebo/química , Sebo/metabolismo , Tensoativos , Fator de Necrose Tumoral alfa , Extração Líquido-Líquido/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA