1.
Eur Radiol ; 32(11): 7700-7709, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35441839

RESUMO

OBJECTIVES: The aim of this study was to compare the quality of images obtained using single-energy computed tomography (SECT) performed with automated tube voltage adaptation (TVA) with dual-energy CT (DECT) weighted average images. METHODS: Eighty patients were prospectively randomized to undergo either SECT with TVA (n = 40, ref. mAs 200) or radiation dose-matched DECT (n = 40, 80/Sn150 kV, ref. mAs tube A 91/tube B 61) on a dual-source CT scanner. Objective image quality was evaluated as dose-normalized contrast-to-noise ratio (CNRD) for the jugular veins relative to fatty tissue and muscle tissue and for muscle tissue relative to fatty issue. For subjective image quality, reproduction of anatomical structures, image artifacts, image noise, spatial resolution, and overall diagnostic acceptability were evaluated at sixteen anatomical substructures using Likert-type scales. RESULTS: Effective radiation dose (ED) was comparable between SECT and DECT study groups (2.9 ± 0.6 mSv/3.1 ± 0.7 mSv, p = 0.5). All examinations were rated as excellent or good for clinical diagnosis. Compared to the CNRD in the SECT group, the CNRD in the DECT group was significantly higher for the jugular veins relative to fatty tissue (7.51/6.08, p < 0.001) and for muscle tissue relative to fatty tissue (4.18/2.90, p < 0.001). The CNRD for the jugular veins relative to muscle tissue (3.33/3.18, p = 0.51) was comparable between groups. Image artifacts were less pronounced and overall diagnostic acceptability was higher in the DECT group (all p = 0.01). CONCLUSIONS: DECT weighted average images deliver higher objective and subjective image quality than SECT performed with TVA in head and neck imaging. KEY POINTS: • Weighted average images derived from dual-energy CT deliver higher objective and subjective image quality than single-energy CT using automated tube voltage adaptation in head and neck imaging. • If available, dual-energy CT acquisition may be preferred over automated low tube voltage adopted single-energy CT for both malignant and non-malignant conditions.


Assuntos
Cabeça , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem , Pescoço
2.
Eur Radiol ; 32(7): 4340-4351, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35184220

RESUMO

OBJECTIVES: To investigate the efficacy of an in-line non-rigid motion-compensated reconstruction (NRC) in an image-navigated high-resolution three-dimensional late gadolinium enhancement (LGE) sequence with Dixon water-fat separation, in a clinical setting. METHODS: Forty-seven consecutive patients were enrolled prospectively and examined with 1.5 T MRI. NRC reconstructions were compared to translational motion-compensated reconstructions (TC) of the same datasets in overall and different sub-category image quality scores, diagnostic confidence, contrast ratios, LGE pattern, and semiautomatic LGE quantification. RESULTS: NRC outperformed TC in all image quality scores (p < 0.001 to 0.016; e.g., overall image quality 5/5 points vs. 4/5). Overall image quality was downgraded in only 23% of NRC datasets vs. 53% of TC datasets due to residual respiratory motion. In both reconstructions, LGE was rated as ischemic in 11 patients and non-ischemic in 10 patients, while it was absent in 26 patients. NRC delivered significantly higher LGE-to-myocardium and blood-to-myocardium contrast ratios (median 6.33 vs. 5.96, p < 0.001 and 4.88 vs. 4.66, p < 0.001, respectively). Automatically detected LGE mass was significantly lower in the NRC reconstruction (p < 0.001). Diagnostic confidence was identical in all cases, with high confidence in 89% and probable in 11% datasets for both reconstructions. No case was rated as inconclusive. CONCLUSIONS: The in-line implementation of a non-rigid motion-compensated reconstruction framework improved image quality in image-navigated free-breathing, isotropic high-resolution 3D LGE imaging with undersampled spiral-like Cartesian sampling and Dixon water-fat separation compared to translational motion correction of the same datasets. The sharper depictions of LGE may lead to more accurate measures of LGE mass. KEY POINTS: • 3D LGE imaging provides high-resolution detection of myocardial scarring. • Non-rigid motion correction provides better image quality in cardiac MRI. • Non-rigid motion correction may lead to more accurate measures of LGE mass.


Assuntos
Meios de Contraste , Gadolínio , Meios de Contraste/farmacologia , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Água
3.
Eur Radiol ; 31(4): 2263-2271, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32970184

RESUMO

OBJECTIVES: Conventional perfusion-weighted MRI sequences often provide poor spatial or temporal resolution. We aimed to overcome this problem in head and neck protocols using a golden-angle radial sparse parallel (GRASP) sequence. METHODS: We prospectively included 58 patients for examination on a 3.0-T MRI using a study protocol. GRASP (A) was applied to a volumetric interpolated breath-hold examination (VIBE) with 135 reconstructed pictures and high temporal (2.5 s) and spatial resolution (0.94 × 0.94 × 3.00 mm). Additional sequences of matching temporal resolution (B: 2.5 s, 1.88 × 1.88 × 3.00 mm), with a compromise between temporal and spatial resolution (C: 7.0 s, 1.30 × 1.30 × 3.00 mm) and with matching spatial resolution (D: 145 s, 0.94 × 0.94 × 3.00 mm), were subsequently without GRASP. Instant inline-image reconstructions (E) provided one additional series of averaged contrast information throughout the entire acquisition duration of A. Overall diagnostic image quality, edge sharpness and contrast of soft tissues, vessels and lesions were subjectively rated using 5-point Likert scales. Objective image quality was measured as contrast-to-noise ratio in D and E. RESULTS: Overall, the anatomic and pathologic image quality was substantially better with the GRASP sequence for the temporally (A/B/C, all p < 0.001) and spatially resolved comparisons (D/E, all p < 0.002 except lesion edge sharpness with p = 0.291). Image artefacts were also less likely to occur with GRASP. Differences in motion, aliasing and truncation were mainly significant, but pulsation and fat suppression were comparable. In addition, the contrast-to-noise ratio of E was significantly better than that of D (pD-E < 0.001). CONCLUSIONS: High temporal and spatial resolution can be obtained synchronously using a GRASP-VIBE technique for perfusion evaluation in head and neck MRI. KEY POINTS: • Golden-angle radial sparse parallel (GRASP) sampling allows for temporally resolved dynamic acquisitions with a very high image quality. • Very low-contrast structures in the head and neck region can benefit from using the GRASP sequence. • Inline-image reconstruction of dynamic and static series from one single acquisition can replace the conventional combination of two acquisitions, thereby saving examination time.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Artefatos , Meios de Contraste , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Perfusão
4.
Eur Radiol ; 31(6): 3951-3961, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33263160

RESUMO

OBJECTIVES: To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. MATERIAL AND METHODS: Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and examined with 1.5 T MRI. Overall subjective image quality, LGE pattern and extent, diagnostic confidence for detection of LGE, and scan time were evaluated and compared to standard 2D LGE imaging. Robustness of Dixon fat suppression was evaluated for 3D Dixon LGE imaging. For statistical analysis, the non-parametric Wilcoxon rank sum test was performed. RESULTS: LGE was rated as ischemic in 9 patients and non-ischemic in 11 patients while it was absent in 20 patients. Image quality and diagnostic confidence were comparable between both techniques (p = 0.67 and p = 0.66, respectively). LGE extent with respect to segmental or transmural myocardial enhancement was identical between 2D and 3D (water-only and in-phase). LGE size was comparable (3D 8.4 ± 7.2 g, 2D 8.7 ± 7.3 g, p = 0.19). Good or excellent fat suppression was achieved in 93% of the 3D LGE datasets. In 6 patients with pericarditis, the 3D sequence with Dixon fat suppression allowed for a better detection of pericardial LGE. Scan duration was significantly longer for 3D imaging (2D median 9:32 min vs. 3D median 10:46 min, p = 0.001). CONCLUSION: The 3D LGE sequence provides comparable LGE detection compared to 2D imaging and seems to be superior in evaluating the extent of pericardial involvement in patients suspected with pericarditis due to the robust Dixon fat suppression. KEY POINTS: • Three-dimensional LGE imaging provides high-resolution detection of myocardial scarring. • Robust Dixon water-fat separation aids in the assessment of pericardial disease. • The 2D image navigator technique enables 100% respiratory scan efficacy and permits predictable scan times.


Assuntos
Gadolínio , Imageamento Tridimensional , Meios de Contraste , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética , Água
5.
J Cardiovasc Magn Reson ; 22(1): 39, 2020 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-32460852

RESUMO

BACKGROUND AND PURPOSE: Interpretation of T2 values remains difficult due to limited comparability across hardware and software systems and the lack of validated measurement recommendations for the number and orientation of mandatory slices. Our aims were to provide a standardized comparison of intra- and inter-individual T2 values in the short and long axes and to investigate inter-scanner reproducibility. METHOD AND MATERIALS: Ninety cardiovascular magnetic resonance (CMR) studies in 30 healthy subjects were performed with three identical 1.5 T CMR scanners (same hardware and software) using a balanced steady-state free precession (bSSFP) gradient echo sequence in three short axis (SAx) and three long axis (LAx) views. A commercially available T2 mapping software package of the latest generation with automatic in-line motion correction was used for acquisition. Regions of interest were manually drawn in each of the 16 myocardial segments according to the American Heart Association (AHA) model in three SAx and three LAx acquisitions. Analysis of inter-scanner, inter-segmental, intra-segmental, inter-regional and inter-level differences was performed. RESULTS: Inter-scanner reproducibility was high and the mean myocardial T2 value for all evaluated segments was 45.7 ± 3.4 ms. Significant inter-segmental variations of mean T2 values were found. Mean intra-segmental T2 values were comparable between LAx and SAx acquisitions in 72%. Significantly higher T2 values were found in apical segments and a significant disparity among different regions was found for SAx and LAx orientations. CONCLUSION: Standardized cardiac T2 mapping is highly reproducible on identical CMR systems. T2 values vary significantly between single heart segments, regions, levels, and axes in young, healthy subjects.


Assuntos
Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/instrumentação , Software , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
6.
J Cardiovasc Magn Reson ; 22(1): 53, 2020 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-32684167

RESUMO

BACKGROUND: Conventional 2D inversion recovery (IR) and phase sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) have been widely incorporated into routine CMR for the assessment of myocardial viability. However, reliable suppression of fat signal, and increased isotropic spatial resolution and volumetric coverage within a clinically feasible scan time remain a challenge. In order to address these challenges, this work proposes a highly efficient respiratory motion-corrected 3D whole-heart water/fat LGE imaging framework. METHODS: An accelerated IR-prepared 3D dual-echo acquisition and motion-corrected reconstruction framework for whole-heart water/fat LGE imaging was developed. The acquisition sequence includes 2D image navigators (iNAV), which are used to track the respiratory motion of the heart and enable 100% scan efficiency. Non-rigid motion information estimated from the 2D iNAVs and from the data itself is integrated into a high-dimensional patch-based undersampled reconstruction technique (HD-PROST), to produce high-resolution water/fat 3D LGE images. A cohort of 20 patients with known or suspected cardiovascular disease was scanned with the proposed 3D water/fat LGE approach. 3D water LGE images were compared to conventional breath-held 2D LGE images (2-chamber, 4-chamber and stack of short-axis views) in terms of image quality (1: full diagnostic to 4: non-diagnostic) and presence of LGE findings. RESULTS: Image quality was considered diagnostic in 18/20 datasets for both 2D and 3D LGE magnitude images, with comparable image quality scores (2D: 2.05 ± 0.72, 3D: 1.88 ± 0.90, p-value = 0.62) and overall agreement in LGE findings. Acquisition time for isotropic high-resolution (1.3mm3) water/fat LGE images was 8.0 ± 1.4 min (3-fold acceleration, 60-88 slices covering the whole heart), while 2D LGE images were acquired in 5.6 ± 2.2 min (12-18 slices, including pauses between breath-holds) albeit with a lower spatial resolution (1.40-1.75 mm in-plane × 8 mm slice thickness). CONCLUSION: A novel framework for motion-corrected whole-heart 3D water/fat LGE imaging has been introduced. The method was validated in patients with known or suspected cardiovascular disease, showing good agreement with conventional breath-held 2D LGE imaging, but offering higher spatial resolution, improved volumetric coverage and good image quality from a free-breathing acquisition with 100% scan efficiency and predictable scan time.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Adiposidade , Água Corporal/química , Doenças Cardiovasculares/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Coração/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Tecido Adiposo/fisiopatologia , Adulto , Idoso , Suspensão da Respiração , Técnicas de Imagem de Sincronização Cardíaca , Doenças Cardiovasculares/fisiopatologia , Eletrocardiografia , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
7.
Eur Radiol ; 29(8): 4207-4214, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30338365

RESUMO

OBJECTIVES: The aim of this study was to compare image quality of single-source dual-energy CT (SS-DECT) with third-generation dual-source dual-energy CT (DS-DECT) in head and neck cancer. MATERIALS AND METHODS: One hundred two patients with histologically proven head and neck cancer were prospectively randomized to undergo radiation dose-matched SS-DECT (n = 51, 120 kV, split-filter technique, 384 ref. mAs) or DS-DECT (n = 51, 80/Sn150 kV, tube A 100/tube B 67 ref. mAs). Inline default images (DI) and virtual monoenergetic images (VMI) for two different low energies (40 and 60 keV) were reconstructed. Objective image quality was evaluated as dose-normalized contrast to noise ratio (CNRD), and subjective image quality was rated on a 5-point Likert scale. RESULTS: In both groups, highest CNRD values for vessel and tumor attenuation were obtained at 40 keV. DS-DECT was significantly better than SS-DECT regarding vessel and tumor attenuation. Overall subjective image quality in the SS-DECT group was highest on the DI followed by 40 keV and 60 keV. In the DS-DECT group, subjective image quality was highest at 40 keV followed by 60 keV and the DI. Forty kiloelectron volts and 60 keV were significantly better in the DS-DECT compared to the SS-DECT group (both p < 0.01). CONCLUSIONS: In split-filter SS-DECT as well as in DS-DECT, highest overall image quality in head and neck imaging can be obtained with a combination of DI and low keV reconstructions. DS-DECT is superior to split-filter SS-DECT in terms of subjective image quality and vessel and tumor attenuation. KEY POINTS: • Image quality was diagnostic with both dual-energy techniques; however, the dual-source technique delivered significantly better results. • Highest overall image quality in head and neck imaging can be obtained with a combination of default images and low keV reconstructions with both dual-energy techniques. • The results of this study may have relevance for the decision-making process regarding replacement of CT scanners and focused patient examination considering image quality and subsequent therapeutic decision-making.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/normas , Feminino , Cabeça/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Exposição à Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Tomografia Computadorizada por Raios X/métodos
8.
J Med Syst ; 43(1): 14, 2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30535865

RESUMO

A CT system with a tablet as mobile user interface and a wireless remote control for positioning and radiation release has recently been presented. Our aim was to evaluate the effects of a mobile CT examination workflow on the radiographers' performance compared to conventional examinations. A prototype of a radiation protection cabin was installed besides the gantry of a CT system. The CT system was equipped with a simplified user interface on a portable tablet and a mobile remote control. 98 patients with an indication for CT of the chest were randomly assigned to examination using the mobile devices (study group, n = 47) or using the conventional stationary workflow on the console (reference group, n = 51). Three ceiling mounted fisheye cameras were used for motion tracking of the radiographers, two in the examination room and one in the control room. Relative density of detection heat-maps and area counts were assessed using a dedicated software tool to quantify radiographers' movements. Duration of each task of the examination was manually recorded using a stopwatch. In the reference group 25% of the area counts were located inside of the examination room, while it was 48% in the study group. The time spent in the same room with the patient increased from 3:06 min (29%) to 6:01 min (57%) using the mobile workflow (p < 0.05), thereof 0:59 min (9%) were spent in moderate separation with maintained voice and visual contact in the radiation protection cabin. Heat-maps showed an increase of the radiographer's working area, indicating a higher freedom of movement. Total duration of the examination was slightly less in the study group without statistical significance (median time: study 10:36, reference 10:50 min; p = 0.29). A mobile CT examination transfers the radiographers' interaction with the scanner from the control room into the examination room. There, radiographers' freedom of movement is higher, without any tradeoffs regarding the examination duration.


Assuntos
Computadores de Mão , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Fluxo de Trabalho , Humanos , Movimento , Sistemas Automatizados de Assistência Junto ao Leito , Proteção Radiológica/métodos , Análise e Desempenho de Tarefas , Fatores de Tempo , Interface Usuário-Computador
9.
J Sports Sci Med ; 17(3): 392-401, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30116112

RESUMO

Delayed-onset muscle soreness (DOMS), an ultrastructural muscle injury, is one of the most common reasons for impaired muscle performance. The purpose of this study was to investigate the influence of sport compression garments on the development of exercise-induced intramuscular edema in the context of DOMS. DOMS was induced in 15 healthy participants. The participants performed a standardized eccentric exercise of the calf muscles. Magnetic resonance imaging (MRI) was performed at baseline and 60h after exercise (T2-weighted signal intensity and T2 relaxation time was evaluated in each compartment and the intramuscular edema in the medial head of the gastrocnemius muscle was segmented). After the exercise, a conventional compression garment (18-21 mmHg) was placed on one randomized calf for 60h. The level of muscle soreness was evaluated using a visual analogue pain scale. T2-weighted signal intensity, T2 relaxation time and intramuscular edema showed a significant interaction for time with increased signal intensities/intramuscular edema in the medial head of the gastrocnemius muscle at follow-up compared to baseline. No significant main effect for compression or interaction between time and limb occurred. Further, no significant differences in the soleus muscle and the lateral head of the gastrocnemius muscle were noted between limbs or over time. After exercise, there was significantly increased muscle soreness in both lower legs in resting condition and when going downstairs and a decreased range of motion in the ankle joint. No significant difference was observed between the compressed and the non-compressed calf. Our results indicate that wearing conventional compression garments after DOMS has been induced has no significant effect on the development of muscle edema, muscle soreness, range of motion and calf circumference.


Assuntos
Edema/prevenção & controle , Músculo Esquelético/lesões , Mialgia/prevenção & controle , Meias de Compressão , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Medição da Dor , Amplitude de Movimento Articular , Adulto Jovem
10.
Neuroradiology ; 59(2): 169-176, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28091696

RESUMO

INTRODUCTION: Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. METHODS: All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. RESULTS: All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNReye globe/air did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. CONCLUSION: Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality.


Assuntos
Doenças dos Seios Paranasais/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Estanho
11.
J Ultrasound Med ; 36(11): 2227-2235, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28556090

RESUMO

OBJECTIVES: The aim of this study was to assess the effectiveness of sonography for diagnosing sialolithiasis in comparison with the existing reference standard of direct identification of a stone. METHODS: A total of 659 glands with signs of obstructive sialadenopathy were evaluated retrospectively. Sonographic examinations of the large head salivary glands had been performed initially in all cases. Direct depiction of a stone during sialoendoscopy or transoral ductal surgery or observation of stone fragmentation with discharge of concrements after extracorporeal shock wave lithotripsy, was regarded as definitive evidence and as the reference standard for the presence of sialolithiasis. The sonographic results were compared with those for direct identification of stones. RESULTS: The sensitivity of sonography was 94.7%, with specificity of 97.4%, a positive predictive value of 99.4%, and a negative predictive value of 79.6%. Stones that were not diagnosed correctly on sonography were most often located in the distal area of the duct. CONCLUSIONS: These results show that sialolithiasis can be diagnosed by sonography with a high degree of certainty. Sonography thus appears to be highly appropriate as the examination method of choice.


Assuntos
Cálculos das Glândulas Salivares/diagnóstico por imagem , Ultrassonografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ductos Salivares/diagnóstico por imagem , Glândulas Salivares/diagnóstico por imagem , Sensibilidade e Especificidade
12.
Eur Radiol ; 26(11): 4155-4161, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26911887

RESUMO

OBJECTIVES: Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. METHODS: In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192x0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 × 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. RESULTS: All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDIvol 1.2 mGy vs. 4.4 mGy, p < 0.001). CONCLUSIONS: Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. KEY POINTS: • Spectral optimization (tin filtration) is beneficial to low-dose parasinus CT • Tin filtration at 100 kV yields sufficient image quality for pre-operative planning • Diagnostic parasinus CT can be performed with an effective dose <0.05 mSv.


Assuntos
Seios Paranasais/diagnóstico por imagem , Sinusite/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Proteção Radiológica/instrumentação , Raios X , Adulto Jovem
13.
Radiology ; 277(2): 406-12, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26225451

RESUMO

PURPOSE: To evaluate the ability of magnetic resonance (MR) imaging to induce deoxyribonucleic acid (DNA) damage in patients who underwent cardiac MR imaging in daily routine by using γ-H2AX immunofluorescence microscopy. MATERIALS AND METHODS: This study complies with the Declaration of Helsinki and was performed according to local ethics committee approval. Informed patient consent was obtained. Blood samples from 45 patients (13 women, 32 men; mean age, 50.3 years [age range, 20-89 years]) were obtained before and after contrast agent-enhanced cardiac MR imaging. MR imaging-induced double-strand breaks (DSBs) were quantified in isolated blood lymphocytes by using immunofluorescence microscopy after staining the phosphorylated histone variant γ-H2AX. Twenty-nine patients were examined with a myocarditis protocol (group A), 10 patients with a stress-testing protocol (group B), and six patients with flow measurements and angiography (group C). Paired t test was performed to compare excess foci before and after MR imaging. RESULTS: The mean baseline DSB level before MR imaging and 5 minutes after MR imaging was, respectively, 0.116 DSB per cell ± 0.019 (standard deviation) and 0.117 DSB per cell ± 0.019 (P = .71). There was also no significant difference in DSBs in these subgroups (group A: DSB per cell before and after MR imaging, respectively, 0.114 and 0.114, P = .91; group B: DSB per cell before and after MR imaging, respectively, 0.123 and 0.124, P = .78; group C: DSB per cell before and after MR imaging, respectively, 0.114 and 0.115, P = .36). CONCLUSION: By using γ-H2AX immunofluorescence microscopy, no DNA DSBs were detected after cardiac MR imaging.


Assuntos
Quebras de DNA de Cadeia Dupla , Cardiopatias/diagnóstico , Linfócitos , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade
14.
Neuroradiology ; 56(9): 797-803, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24961883

RESUMO

INTRODUCTION: Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. METHODS: One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDIvol. RESULTS: Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8%. CONCLUSIONS: TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality.


Assuntos
Eletricidade , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
15.
Diagnostics (Basel) ; 13(7)2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37046460

RESUMO

This study compares the diagnostic performance and image quality of single-shot turbo spin-echo DWI (tseDWI), standard readout-segmented DWI (rsDWI), and a modified rsDWI version (topupDWI) for cholesteatoma diagnostics. Thirty-four patients with newly suspected unilateral cholesteatoma were examined on a 1.5 Tesla MRI scanner. Diagnostic performance was evaluated by calculating and comparing the sensitivity and specificity using histopathological results as the standard of reference. Image quality was independently reviewed by two readers using a 5-point Likert scale evaluating image distortions, susceptibility artifacts, image resolution, lesion conspicuity, and diagnostic confidence. Twenty-five cholesteatomas were histologically confirmed after surgery and originated in the study group. TseDWI showed the highest sensitivity with 96% (95% confidence interval (CI): 88-100%), followed by topupDWI with 92% (95% CI: 81-100%) for both readers. The sensitivity for rsDWI was 76% (95% CI: 59-93%) for reader 1 and 84% (95% CI: 70-98%) for reader 2, respectively. Both tseDWI and topupDWI revealed a specificity of 100% (95% CI: 66-100%) and rsDWI of 89% (95% CI: 52-100%). Both tseDWI and topupDWI showed fewer image distortions and susceptibility artifacts compared to rsDWI. Image resolution was consistently rated best for topupDWI, followed by rsDWI, which both outperformed tseDWI. TopupDWI and tseDWI showed comparable results for lesions' conspicuity and diagnostic confidence, both outperforming rsDWI. Modified readout-segmented DWI using the topup-correction method is preferable to standard rsDWI and may be regarded as an accurate alternative to single-shot turbo spin-echo DWI in cholesteatoma diagnostics.

16.
Acad Radiol ; 30(12): 2962-2972, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37179206

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the diagnostic utility of iterative metal artifact reduction (iMAR) in computed tomography (CT)-imaging of oral and oropharyngeal cancers when obscured by dental hardware artifacts and to determine the most appropriate iMAR settings for this purpose. MATERIALS AND METHODS: The study retrospectively enrolled 27 patients (8 female, 19 male; mean age 64±12.7years) with histologically confirmed oral or oropharyngeal cancer obscured by dental artifacts in contrast-enhanced CT. Raw CT data were reconstructed with ascending iMAR strengths (levels 1/2/3/4/5) and one reconstruction without iMAR (level 0). For subjective analysis, two blinded radiologists rated tumor visualization and artifact severity on a five-point Likert scale. For objective analysis, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and artifact index (AI) were determined. RESULTS: iMAR reconstructions improved the subjective image quality of tumor edge and contrast, and the objective parameters of tumor SNR and CNR, reaching their optimum at iMAR levels 4 and 5 (P<.001). AI decreased with iMAR reconstructions reaching its minimum at iMAR level 5 (P<.001). Tumor detection rates increased 2.4-fold with iMAR 5, 2.1-fold with iMAR 4, and 1.9-fold with iMAR 3 compared to reconstructions without iMAR. Disadvantages such as algorithm-induced artifacts increased significantly with higher iMAR strengths (P<.05), reaching a maximum with iMAR 5. CONCLUSION: iMAR significantly improves CT imaging of oral and oropharyngeal cancers, as confirmed by both subjective and objective measures, with best results at highest iMAR strengths.


Assuntos
Artefatos , Neoplasias Orofaríngeas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Metais , Tomografia Computadorizada por Raios X/métodos , Neoplasias Orofaríngeas/diagnóstico por imagem , Algoritmos
17.
Diagnostics (Basel) ; 13(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37510147

RESUMO

(1) Purpose: to compare right ventricular (RV) functional parameters in children with surgically repaired congenital heart disease (CHD) using single/double breath hold (BH) and free-breathing (FB) real-time compressed sensing (CS) cine cardiac magnetic resonance (cMRI) with standard retrospective segmented multi breath hold (RMB) cine cMRI. (2) Methods: Twenty patients with CHD underwent BH and FB, as well as RMB cine cMRI, at 3T to obtain a stack of continuous axial images of the RV. Two radiologists independently performed qualitative analysis of the image quality (rated on a 5-point scale; 1 = non-diagnostic to 5 = excellent) and quantitative analysis of the RV volume measurements. (3) Results: The best image quality was provided by RMB (4.5; range 2-5) compared to BH (3.9; range 3-5; p = 0.04) and FB (3.6; range 3-5; p < 0.01). The RV functional parameters were comparable among BH, FB, and RMB with a difference of less than 5%. The scan times for BH (44 ± 38 s, p < 0.01) and FB (24 ± 7 s, p < 0.01) were significantly reduced compared to for RMB (261 ± 68 s). (4) Conclusions: CS-FB and CS-BH real-time cine cMRI in children with CHD provides diagnostic image quality with excellent accuracy for measuring RV function with a significantly reduced scan time compared to RMB.

18.
Invest Radiol ; 58(3): 216-222, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36165876

RESUMO

OBJECTIVES: Presurgical identification and morphologic characterization of the peroneal perforator arteries (PPAs) are essential for osseomyocutaneous flap surgery. The aim of this study was to evaluate PPAs using time-of-flight (TOF) angiography in 7 T magnetic resonance imaging in comparison with dual-energy computed tomographic angiography (CTA). MATERIALS AND METHODS: In this prospective study, TOF angiography and CTA of both lower legs were acquired before flap surgery from 07/2019 to 02/2020. Magnetic resonance imaging was performed using a dedicated 28-channel knee coil with an acquisition time of 9:55 minutes (voxel size: 0.4 × 0.4 × 0.8 mm). Computed tomographic angiography was acquired with a third-generation dual-source computed tomography on the same day. Virtual monoenergetic reconstructions at 40 keV photon energy served as the standard of reference for PPA identification and subtyping. Two independent readers assessed the image quality, quantity, length assessment, and classification according to surgical considerations of PPAs for TOF angiography and CTA. Both TOF angiography and CTA were used for presurgical flap design and were evaluated by an orofacial surgeon. RESULTS: Ten patients (mean age, 59.9 ± 14.9 years; 7 men) were included. Time-of-flight angiography and CTA identified 53 and 51 PPAs in total, respectively. Time-of-flight angiography showed superior image quality (both readers, P < 0.05). Time-of-flight angiography enabled specific classification of PPA subtypes more often (53 vs 39; P < 0.05), and both readers reported higher diagnostic confidence for TOF angiography than CTA in all patients (interrater agreement κ = 0.8; P < 0.05). Regarding length assessment, PPAs were significantly more conspicuous with TOF angiography (TOF mean , 50 ± 11 mm; CTA mean , 40 ± 9 mm; P = 0.001). In comparison with CTA, TOF angiography prospectively changed the orofacial surgeon's final decision on the presurgical selected PPAs in 60% of cases. CONCLUSIONS: Presurgical assessment of PPAs is feasible using TOF in 7 T magnetic resonance imaging. Moreover, TOF angiography was superior to CTA for classifying and identifying PPAs, which may facilitate the planning of reconstructive surgery.


Assuntos
Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Angiografia por Ressonância Magnética/métodos , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Artérias
19.
Bioengineering (Basel) ; 10(12)2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38135956

RESUMO

Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.

20.
Eur J Nucl Med Mol Imaging ; 39(11): 1712-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22854986

RESUMO

PURPOSE: The purpose of this study was to evaluate DNA double-strand breaks (DSBs) in blood lymphocytes of patients undergoing positron emission tomography (PET)/CT using γ-H2AX immunofluorescence microscopy and to differentiate between (18)F-fluorodeoxyglucose (FDG) and CT-induced DNA lesions. METHODS: This study was approved by the local Ethics Committee and complies with Health Insurance Portability and Accountability Act (HIPAA) requirements. After written informed consent was obtained, 33 patients underwent whole-body (18)F-FDG PET/CT (3 MBq/kg body weight, 170/100 reference mAs at 120 kV). The FDG PET and CT portions were performed as an initial CT immediately followed by the PET. Blood samples were obtained before, at various time points following (18)F-FDG application and up to 24 h after the CT scan. Distinct foci representing DSBs were quantified in isolated lymphocytes using fluorescence microscopy after staining against the phosphorylated histone variant γ-H2AX. RESULTS: The DSB values at the various time points were significantly different (p < 0.001). The median baseline level was 0.08/cell (range 0.06-0.12/cell). Peaks of radiation-induced DSBs were found 30 min after (18)F-FDG administration (median excess foci 0.11/cell, range 0.06-0.27/cell) and 5 min after CT (median excess foci 0.17/cell, range 0.05-0.54/cell). A significant correlation between CT-induced DSBs and dose length product was obtained (ρ = 0.898, p < 0.001). After 24 h DSB values were still slightly but significantly elevated (median foci 0.11/cell, range 0.10-0.14/cell, p = 0.003) compared to pre-exposure levels. CONCLUSION: PET/CT-induced DSBs can be monitored using γ-H2AX immunofluorescence microscopy. Peak values may be obtained 30 min after (18)F-FDG injection and 5 min after CT. The radionuclide contributes considerably to the total DSB induction in this setting.


Assuntos
Quebras de DNA de Cadeia Dupla , Reparo do DNA , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Histonas/metabolismo , Humanos , Linfócitos/efeitos da radiação , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade , Fosforilação