Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 44(3): 622-625, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30702694

RESUMO

We describe a means of communication in which a user with no external receiver hears an audible audio message directed only at him/her. A laser transmits the message, which is encoded upon a modulated laser beam and sent directly to the receiver's ear via the photoacoustic effect. A 1.9 µm thulium laser matched to an atmospheric water vapor absorption line is chosen to maximize sound pressure while maintaining eye-safe power densities. We examine the photoacoustic transfer function describing this generation of audible sound and the important operational parameters, such as laser spot size, and their impact on a working system.

2.
Light Sci Appl ; 8: 119, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31885865

RESUMO

Full noncontact laser ultrasound (LUS) imaging has several distinct advantages over current medical ultrasound (US) technologies: elimination of the coupling mediums (gel/water), operator-independent image quality, improved repeatability, and volumetric imaging. Current light-based ultrasound utilizing tissue-penetrating photoacoustics (PA) generally uses traditional piezoelectric transducers in contact with the imaged tissue or carries an optical fiber detector close to the imaging site. Unlike PA, the LUS design presented here minimizes the optical penetration and specifically restricts optical-to-acoustic energy transduction at the tissue surface, maximizing the generated acoustic source amplitude. With an appropriate optical design and interferometry, any exposed tissue surfaces can become viable acoustic sources and detectors. LUS operates analogously to conventional ultrasound but uses light instead of piezoelectric elements. Here, we present full noncontact LUS results, imaging targets at ~5 cm depths and at a meter-scale standoff from the target surface. Experimental results demonstrating volumetric imaging and the first LUS images on humans are presented, all at eye- and skin-safe optical exposure levels. The progression of LUS imaging from tissue-mimicking phantoms, to excised animal tissue, to humans in vivo is shown, with validation from conventional ultrasound images. The LUS system design insights and results presented here inspire further LUS development and are a significant step toward the clinical implementation of LUS.

3.
J Biomed Opt ; 24(2): 1-11, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30550046

RESUMO

Short optical pulses emitted from a tunable Q-switched laser (800 to 2000 nm) generate laser ultrasound (LUS) signals at the surface of biological tissue. The LUS signal's acoustic frequency content, dependence on sample type, and optical wavelength are observed in the far field. The experiments yield a reference dataset for the design of noncontact LUS imaging systems. Measurements show that the majority of LUS signal energy in biological tissues is within the 0.5 and 3 MHz frequency bands and the total acoustic energy generated increases with the optical absorption coefficient of water, which governs tissue optical absorption in the infrared range. The experimental results also link tissue surface roughness and acoustic attenuation with limited LUS signal bandwidth in biological tissue. Images constructed using 810-, 1064-, 1550-, and 2000-nm generation laser wavelengths and a contact piezoelectric receiver demonstrates the impact of the generation laser wavelength on image quality. A noncontact LUS-based medical imaging system has the potential to be an effective medical imaging device. Such a system may mitigate interoperator variability associated with current medical ultrasound imaging techniques and expand the scope of imaging applications for ultrasound.


Assuntos
Ultrassom/métodos , Ultrassonografia/métodos , Diagnóstico por Imagem/métodos , Lasers
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA