Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
J Infect Chemother ; 30(7): 668-671, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38135218

RESUMO

Universal screening for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on admission is reportedly beneficial in preventing nosocomial infections. However, some issues remain, including low positivity rate, cost, and time required for testing. We describe SARS-CoV-2 reverse transcription polymerase chain reaction (PCR) for universal screening in asymptomatic patients on planned admissions. In total, 14,574 patients were included between October 12, 2020, and June 23, 2022. The PCR-positive rate for the period was 0.44 % (64/14,574). The PCR positivity for the epidemic period by strain was 0.28 % (95 % confidence interval [CI] 0.12-0.56 %), 0.16 % (95 % CI 0.05-0.37 %), 0.21 % (95 % CI 0.09-0.41 %), and 0.9 % (95 % CI 0.65-1.2 %) for the wild-type strain, Alpha, Delta, and Omicron variants, respectively. The proportion of Ct values < 30 was higher in the first half of the epidemic (first vs. second, 29.4 % [95 % CI 16.9-44.8 %] vs. 16.7 % [95 % CI 6.0-28.5 %]), whereas that of Ct values ≥ 35 increased significantly in the second half (first vs. second, 32.4 % [95 % CI 19.3-47.8 %] vs. 70.0 % [95 % CI 53.5-83.4 %]). Of all positives, 50 % (32/64) had a coronavirus disease (COVID-19) history before PCR screening, with a median of 28 days (10-105) from COVID-19 onset or positive to PCR screening. PCR screening may help detect positives with high viral loads early in the epidemic for each mutant strain, with an increasing proportion of positives with low viral loads later in the epidemic. PCR testing may be unnecessary for recently diagnosed cases and patients in whom reinfection is unlikely.


Assuntos
Infecções Assintomáticas , Teste de Ácido Nucleico para COVID-19 , COVID-19 , Programas de Rastreamento , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Masculino , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Feminino , Infecções Assintomáticas/epidemiologia , Adulto , Idoso , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Idoso de 80 Anos ou mais
2.
Echocardiography ; 40(12): 1374-1382, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37985209

RESUMO

BACKGROUND: Residual regurgitation after transcatheter edge-to-edge mitral valve repair (TMVR) is a predictor of poor prognosis in patients with functional mitral regurgitation (FMR). This study sought to identify the mitral valve (MV) parameters measured by three-dimensional transesophageal echocardiography (3D-TEE) and MV leaflet features that predict residual mitral regurgitation (MR) after TMVR in patients with FMR. METHODS: Consecutive patients with FMR who underwent TMVR were classified into two groups based on the degree of residual MR just after TMVR: < 2+ in the optimal MR reduction group and ≥ 2+ in the suboptimal MR reduction group. The two groups were compared with respect to 3D-TEE parameters and the MV leaflet features, including the following parameters: stiffness, defined as a leaflet that remains at a fixed angle even during diastole, and thickness, measured in both clear and rough zones. RESULTS: Thirty-four of 46 patients (74%) were classified as the optimal MR reduction group. Multivariable analysis showed that anterior mitral leaflet + posterior mitral leaflet length/anteroposterior annulus diameter (p = .044) and MV leaflet stiffness (p = .007) were independent predictors of residual MR. CONCLUSION: MV leaflet stiffness and the ratio of MV leaflet lengths to the annulus diameter may be good predictors of residual MR after TMVR in patients with FMR.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Resultado do Tratamento
3.
J Nucl Cardiol ; 29(5): 2652-2663, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34561849

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) can rapidly improve cardiac sympathetic nervous function (CSNF) within 2 weeks in patients with aortic stenosis (AS). However, whether such short-term improvements will be sustained thereafter remains unclear. METHODS: Patients with severe AS who underwent TAVR between October 2017 and June 2019 were enrolled in this single-center, prospective, observational study. 123I-meta-iodobenzylguanidine imaging was performed at baseline, within 2 weeks after TAVR, and at 6 to 12 months post-TAVR to evaluate the heart-mediastinum ratio (H/M) and washout rate. RESULTS: Of 183 consecutive patients, 75 (19 men; median age: 86 years) were evaluated. The late H/M significantly improved within 2 weeks after TAVR (P = .041) and further improved over 6 to 12 months after TAVR (P = .041). Multivariate analysis revealed that the baseline mean aortic valve pressure gradient (mPG) was an independent predictor of mid-term improvement in the late H/M (> 0.1) (P = .037). Patients with a high baseline mPG (≥ 58 mmHg) exhibited a significantly greater increase in the late H/M than those with a low baseline mPG (< 42 mmHg) (0.24 vs 0.01; P = .029). CONCLUSION: CSNF demonstrated sustained improvement from within 2 weeks after TAVR until 6 to 12 months later. Such improvement was related to baseline hemodynamic AS severity.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , 3-Iodobenzilguanidina , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Radioisótopos do Iodo , Masculino , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
5.
Eur J Nucl Med Mol Imaging ; 47(7): 1657-1667, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31502014

RESUMO

PURPOSE: The effects of transcatheter aortic valve replacement (TAVR) on cardiac sympathetic nervous (CSN) function have not been fully explored. This study aimed to investigate the early (within 2 weeks) effects of TAVR on CSN function in patients with severe aortic valve stenosis (AS) using 123I-metaiodobenzylguanidine (MIBG) scintigraphy. METHODS: Of 143 consecutive patients who were scheduled to undergo TAVR, 67 (18 men; median age 86 years) were evaluated in this single-centre prospective observational study. MIBG scintigraphy was performed at baseline and 3-14 days after the TAVR procedure to evaluate the heart-mediastinum ratio (H/M) and washout rate (WR). Differences between baseline and post-TAVR MIBG parameters were analysed. MIBG parameter changes were compared with echocardiographic parameters. Furthermore, factors involved in the improvement in MIBG parameters were investigated. RESULTS: All patients successfully underwent TAVR with improved echocardiographic parameters, including aortic valve area (AVA; 0.6 cm2 vs. 1.6 cm2), peak velocity (4.5 m/s vs. 2.0 m/s), mean pressure gradient (50 mmHg vs. 9 mmHg), and left ventricular ejection fraction (56% vs. 62%) (all p < 0.001). On MIBG imaging, delayed H/M significantly increased (2.57 vs. 2.68, p < 0.001), whereas WR decreased (32.2% vs. 26.8%, p < 0.001). In multivariate analysis, higher baseline WR was associated with improvement in WR (> 3%). Female sex, Clinical Frailty Scale score ≤ 5, baseline estimated glomerular filtration rate, and baseline AVA were predictors of improvement in delayed H/M (> 0.1). Baseline AVA and E/E' were independent predictors of improvement in both WR and delayed H/M. CONCLUSIONS: The CSN function was impaired in patients with AS, as assessed using MIBG scintigraphy. WR and delayed H/M improved immediately after TAVR. Improvement in CSN function may be related to echocardiographic AS severity at baseline before TAVR.


Assuntos
Estenose da Valva Aórtica , Coração , Radioisótopos do Iodo , Cintilografia , Sistema Nervoso Simpático , Substituição da Valva Aórtica Transcateter , 3-Iodobenzilguanidina/metabolismo , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Coração/diagnóstico por imagem , Coração/inervação , Humanos , Masculino , Índice de Gravidade de Doença , Fatores Sexuais , Volume Sistólico , Sistema Nervoso Simpático/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/normas , Resultado do Tratamento , Função Ventricular Esquerda
6.
Circ J ; 84(2): 269-276, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31902829

RESUMO

BACKGROUND: Cardiac conduction disturbance (CD) is the most frequent complication following transcatheter aortic valve replacement (TAVR). This study examined whether the anatomy of the membranous septum (MS) could provide useful information about the risk of CD following TAVR with a balloon-expandable valve (BEV).Methods and Results:Among 132 consecutive patients, 106 (mean age, 85.6±5.1 years; 75 females) were included in the study. Using preoperative CT and angiography, MS length and implantation depth (ID) were assessed. The MS length minus the prosthesis ID was calculated (∆MSID). Correlation between CD, defined as new-onset left-bundle branch block (LBBB) or the need for permanent pacemaker (PPM) within 1 week after the procedure, and MS length were evaluated. A total of 19 patients (18%) developed CD following TAVR. MS length was significantly shorter in these patients than in those without CD (5.3±1.3 vs. 6.6±1.4; P<0.001), and was the important predictor of CD (odds ratio [OR]: 0.43, 95% confidence interval [CI]: 0.27-0.69, P<0.001). When considering the pre- and postprocedural parameters, the ∆MSID was smaller in patients with CD (-1.7±1.5 vs. 0.8±1.9, P<0.001), and emerged as the important predictor of CD (OR: 0.47, 95% CI: 0.33-0.69, P<0.001). CONCLUSIONS: Short MS is associated with an increased risk of CD after TAVR with BEV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Bloqueio de Ramo/etiologia , Angiografia por Tomografia Computadorizada , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Septo Interventricular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Septo Interventricular/fisiopatologia
7.
Heart Vessels ; 35(5): 672-680, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31701229

RESUMO

Heart failure (HF) is often accompanied by skeletal muscle weakness and exercise intolerance, which are known as prognostic factors of HF. Comprehensive evaluation of physical function is important, but it is not commonly conducted because of the lack of equipment or appropriate expertise. Measurement of rectus femoris diameter (RFD) by ultrasound is convenient and noninvasive, but it has not been clarified that RFD could represent physical functions in HF patients. This study evaluated 185 consecutive HF patients and underwent assessment including RFD, grip power (GP), knee extension strength (KES), skeletal muscle index (SMI), nutrition status, cardiopulmonary exercise testing, and New York Heart Association (NYHA) functional class. RFD was related with NYHA class and significantly correlated with GP, KES, SMI, body mass index, pre-albumin level, geriatric nutritional risk index, and peak VO2 (r = 0.631, 0.676, 0.510, 0.568, 0.380, 0.539, 0.527, respectively; p < 0.001). Multivariate regression analysis revealed that estimated glomerular filtration rate (ß = 0.551) and RFD (ß = 0.326) were predictive factors of peak VO2. Gender, age, brain natriuretic peptide level, left ventricular ejection fraction, and hemoglobin level were the other explanatory parameters. The cut off value of RFD for sarcopenia diagnosis was estimated as 15 mm (sensitivity = 0.767 and specificity = 0.808). RFD is a simple and useful marker which reflects skeletal muscle strength/volume, exercise tolerance, nutrition status, and NYHA class. It is also associated with sarcopenia in HF patients.


Assuntos
Tolerância ao Exercício , Insuficiência Cardíaca/diagnóstico por imagem , Força Muscular , Músculo Quadríceps/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Ultrassonografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aptidão Cardiorrespiratória , Teste de Esforço , Feminino , Força da Mão , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estado Nutricional , Consumo de Oxigênio , Valor Preditivo dos Testes , Músculo Quadríceps/fisiopatologia , Sarcopenia/fisiopatologia
8.
Heart Lung Circ ; 28(4): 655-659, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30224170

RESUMO

BACKGROUND: Chronic thromboembolic pulmonary hypertension (CTEPH) is a progressive disorder with a poor prognosis. Recently, balloon pulmonary angioplasty (BPA) has been reported to be an effective treatment for inoperable patients with CTEPH. However, this catheter-based treatment has potentially life-threatening vascular complications. To improve the efficacy and safety of BPA, we assessed the morphological evaluation of organised thrombus and the vascular injury by BPA procedure. METHODS: In this study, we assessed the morphology of organised thrombi and the vascular injury observed by angioscopy during BPA in 28 lesions from nine CTEPH patients. RESULTS: Angioscopy visualised various forms of organised thrombi such as 'Mesh', 'Slit', 'Flap' and 'Mass' and allowed for a detailed evaluation of organised thrombus that was difficult to do by conventional contrast angiography. In addition, after balloon dilation for BPA, angioscopy revealed a haemorrhage due to a vessel wall injury caused by wiring and/or ballooning. CONCLUSIONS: Assessment of organised thrombus and vascular injury by angioscopy might contribute to improving the treatment of the patients with CTEPH.


Assuntos
Angioplastia com Balão/métodos , Angioscopia/métodos , Hipertensão Pulmonar/diagnóstico , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Angiografia , Doença Crônica , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia , Pressão Propulsora Pulmonar/fisiologia , Resultado do Tratamento , Ultrassonografia de Intervenção
9.
J Heart Valve Dis ; 27(1): 71-77, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30560602

RESUMO

BACKGROUND: Brachial-ankle pulse wave (ba-PW) analysis is an established technique for assessing arterial stiffness and cardiovascular risk. The peripheral arterial pulse wave configuration may be useful for valvular heart disease (VHD) detection because it is closely related to the physical signs of VHD; however, few reports have been made assessing the efficacy of ba-PW analysis for VHD screening. METHODS: Consecutive VHD patients scheduled for valve surgery were enrolled in the study. These included 58 patients with aortic stenosis (AS) (mean age 74 ± 1.1 years), 67 with aortic regurgitation (AR) (mean age 59 ± 1.9 years), and 65 with mitral regurgitation (MR) (mean age 62 ± 1.6 years). Ba-PW analysis was conducted using the VaSera VS-1500 screening system before and after surgery. Upstroke time (UT), ejection time (ET), pre-ejection period (PEP), PEP/ET ratio, mean arterial pressure (%MAP), and cardio-ankle vascular index (CAVI) were compared with a control group (n = 65; mean age 69 ± 1.5 years) without VHD. RESULTS: The UT was significantly shorter in the AR group (132.9 ± 4.0 ms) and MR group (134.5 ± 2.5 ms), but significantly longer in the AS group (178.2 ± 2.8 ms) compared to controls (149.6 ± 3.6 ms; all p <0.01). The ET was significantly longer in the AS group (318.5 ± 7.4 ms) and AR group (320.0 ± 4.6 ms), but significantly shorter in the MR group (289.0 ± 3.8 ms) compared to controls (305.3 ± 3.4 ms; all p <0.05). In ROC analyses of each group compared to controls, areas under the curve of UT, corrected (c)UT, ET and cET in the AS group, UT/ET ratio in the AR group, and PEP/UT ratio in the MR group were all >0.7. CONCLUSIONS: Multiple pulse wave parameters reflect VHD hemodynamics and may be useful for screening for the condition.


Assuntos
Índice Tornozelo-Braço , Doenças das Valvas Cardíacas/fisiopatologia , Idoso , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Análise de Onda de Pulso
10.
Circ J ; 81(11): 1693-1698, 2017 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-28637970

RESUMO

BACKGROUND: Patients with ST-elevation myocardial infarction (STEMI) who arrive at a hospital via self-transport reportedly have a delayed door-to-balloon time (DBT). However, the clinical impacts of delayed DBT on in-hospital mortality among such patients are not well known.Methods and Results:In total, 1,172 STEMI patients who underwent primary percutaneous coronary intervention between January 2009 and December 2013 from the Acute Myocardial Infarction (AMI) Kyoto Registry were analyzed. Compared with the emergency medical service (EMS) group (n=804), the self-transport group (n=368) was younger and had a significantly longer DBT (115 min vs. 90 min, P<0.01), with fewer patients having a Killip classification of 2 or higher. The in-hospital mortality rate was lower in the self-transport group than in the EMS group (3.3% vs. 7.1%, P<0.01). A DBT >90 min was an independent predictor of in-hospital mortality in EMS patients (odds ratio (OR)=2.43, P=0.01) but not in self-transport patients (OR=0.89, P=0.87). CONCLUSIONS: The present study demonstrated that there was no relationship between in-hospital prognosis and DBT ≤90 min in STEMI patients using self-transport. The prognosis of these patients cannot be improved by focusing only on DBT. Treatment strategies based on means of transport should also be considered.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Transporte de Pacientes/métodos , Idoso , Idoso de 80 Anos ou mais , Serviços Médicos de Emergência , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Sistema de Registros , Fatores de Tempo
11.
Int Heart J ; 58(6): 1008-1011, 2017 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-29151483

RESUMO

A 54-year-old woman with a history of multiple cardiac surgeries suffered from hypoxemia caused by a right-to-left intra-cardiac shunt due to coronary sinus (CS) anomaly with persistent left superior vena cava (PLSVC). Both the contrast echocardiography and enhanced computed tomography (CT) provided conclusive diagnosis of this rare congenital anomaly, which was overlooked for a long time. However, an important diagnostic clue was left-arm injection of the contrast media. In the present case, previously performed enhanced CT with its routine manner, i.e., contrast through the right arm, missed this anomaly. It is crucial to note that the unusual type of unroofed CS with PLSVC, presenting with an entirely right-to-left intra-cardiac shunt, cannot be delineated on an enhanced routine chest CT if the contrast media is injected through the right arm.


Assuntos
Meios de Contraste/administração & dosagem , Seio Coronário/anormalidades , Átrios do Coração/anormalidades , Cardiopatias Congênitas/diagnóstico por imagem , Hipóxia/etiologia , Seio Coronário/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Átrios do Coração/diagnóstico por imagem , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Humanos , Hipóxia/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores
13.
J Heart Valve Dis ; 24(6): 744-751, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27997781

RESUMO

BACKGROUND: Patients are occasionally encountered with high mitral pressure gradients after mitral valve repair for degenerative mitral regurgitation (MR), despite the use of a 'truesized' ring based on the anterior leaflet dimension. The study aim was to assess these patients at rest and during exercise, using echocardiography. METHODS: Sixty-seven patients who underwent mitral repair for degenerative disease using a semi-rigid, complete annuloplasty ring were assessed. A truesized ring was always selected for the annuloplasty. Of these patients, 20 were enrolled for exercise stress echocardiography. The indexed ring orifice area (iROA) was calculated by dividing the geometric orifice area of the annuloplasty ring by the patient's body surface area (BSA). Postoperatively, the patients were in sinus rhythm and had less than moderate MR. RESULTS: During peak exercise, seven patients were considered to have severe mitral stenosis (MS), with a mean pressure gradient (mPG) >15 mmHg. The annuloplasty rings used in these seven patients were significantly smaller than those used in the other 13 patients (28.6 ± 1.9 mm versus 33.1 ± 3.1 mm; p = 0.003). The mPG at peak exercise was strongly correlated with the iROA (r = -0.767, p <0.001). CONCLUSIONS: Mitral repair, even following the use of a true-sized ring, may be associated with severe MS when the ring size is relatively small for the patient's BSA. This association was shown to become more prominent during exercise.

14.
J Med Ultrason (2001) ; 51(2): 275-282, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38228943

RESUMO

The initial means of detecting right ventricular (RV) dilatation is often transthoracic echocardiography (TTE), and once the presence of RV dilatation is suspected, there is the possibility of RV volume overload, RV pressure overload, RV myocardial disease, and even nonpathological RV dilatation. With respect to congenital heart disease with RV volume overload, defects or valvular abnormalities can be easily detected with TTE, with the exception of some diseases. Volumetric assessment using three-dimensional echocardiography may be useful in determining the intervention timing in these diseases. When the disease progresses in patients with pulmonary hypertension as a result of RV pressure overload, RV dilatation becomes more prominent than hypertrophy, and RV functional parameters predict the prognosis at this stage of maladaptive remodeling. The differential diagnosis of cardiomyopathy or comparison with nonpathological RV dilatation may be difficult in the setting of RV myocardial disease. The characteristics of RV functional parameters such as two-dimensional speckle tracking may help differentiate RV cardiomyopathy from other conditions. We review the diseases presenting with RV dilatation, their characteristics, and echocardiographic findings and parameters that are significant in assessing their status or intervention timing.


Assuntos
Ecocardiografia , Ventrículos do Coração , Humanos , Diagnóstico Diferencial , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Hipertrofia Ventricular Direita/diagnóstico por imagem , Hipertrofia Ventricular Direita/fisiopatologia , Ecocardiografia Tridimensional/métodos , Dilatação Patológica/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem
15.
JACC Case Rep ; 29(7): 102284, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38645288

RESUMO

Pulmonary vein stenosis might be caused by mediastinal migration into the vacated pleural space after pneumonectomy. In a patient complaining of worsening dyspnea in the left lateral decubitus position after left pneumonectomy, transthoracic echocardiography during different postures revealed pulmonary vein stenosis that worsened in the left lateral position.

16.
Int J Cardiol ; 413: 132348, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38977224

RESUMO

BACKGROUND: Balloon aortic valvuloplasty (BAV) has gained renewed interest as a bridge to transcatheter aortic valve replacement (TAVR) for patients with aortic stenosis (AS). However, it is unclear whether they patients should undergo TAVR directly or receive a staged bridge to BAV before TAVR is unclear. We used a national database to examine the association between BAV and TAVR in patients with TAVR and its effect on in-hospital mortality. METHODS: Using the nationwide inpatient database of the Japanese registry of all cardiac and vascular diseases and the combination of the diagnosis procedure combination, we retrospectively analyzed 27,600 patients with AS who underwent TAVR between October 2013 and March 2021. Outcomes of the direct TAVR group (n = 27,387) were compared with those of the BAV bridge to TAVR group (n = 213), which received BAV at least 1 day before TAVR. RESULTS: The median age was 85 (interquartile range: 82-88) years, with 33.3% (n = 9188) being male. Unplanned/emergent admissions increased with TAVR, whereas the use of BAV bridge to TAVR decreased. The in-hospital mortality rate was 1.3% and decreased over time. However, the BAV bridge to TAVR had a significantly higher in-hospital mortality than direct TAVR (5.6% vs. 1.3%; p < .0001). Factors associated with in-hospital mortality included age, body mass index, chronic renal disease, percutaneous coronary intervention, and BAV bridge to TAVR. CONCLUSIONS: In unplanned/emergent and planned admission settings, the in-hospital mortality rate for BAV bridge to TAVR is worse than that for direct TAVR. Practical criteria for BAV bridge to TAVR should be proposed to improve outcomes.

17.
Int J Cardiol ; 395: 131404, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37777073

RESUMO

BACKGROUND: Worsening mitral regurgitation (MR) is a complication of intervention for atrial septal defect (ASD). Little is known about mitral valve (MV) characteristics associated with worsening MR. We aimed to elucidate MR outcomes and predictors of worsening MR after transcatheter ASD closure. METHODS: We analyzed changes in MR from prior to transcatheter ASD closure to 6 months after the procedure and predictors of worsening MR via baseline transthoracic echocardiography in 238 patients (64.7% females; mean age, 53 ± 22 years). RESULTS: Worsening MR was defined as worsening to moderate in patients with less than or equal to mild MR at baseline or vena contracta width increasing of ≥2 mm by 6-month follow-up in patients with moderate MR. Worsening MR was observed in 29 patients (12.2%). The associated echocardiographic findings were pseudoprolapse, hamstringing, stiffness, and anteroposterior and intercommissural mitral annulus diameter in the univariable logistic regression analysis (all P < 0.05). Multivariable analysis after adjusting for age; long-standing persistent atrial fibrillation; and ASD size showed that models combining MV leaflet findings such as pseudoprolapse or hamstringing, or anterior leaflet stiffness with the ratio of the sum of anterior and posterior leaflet lengths to intercommissural mitral annulus diameter were statistically significant for predicting worsening MR (R2 = 0.393, P < 0.001 and R2 = 0.385, P < 0.001, respectively). CONCLUSIONS: Worsening MR after transcatheter ASD closure might depend on MV leaflet findings and annulus size in patients with long-standing persistent atrial fibrillation.


Assuntos
Fibrilação Atrial , Comunicação Interatrial , Insuficiência da Valva Mitral , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Estudos Retrospectivos , Valva Mitral , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia
18.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37543193

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Qualidade de Vida , Análise Custo-Benefício , Estudos Prospectivos , Fragilidade/etiologia , Estenose da Valva Aórtica/etiologia , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
19.
Circ J ; 77(12): 2990-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24088304

RESUMO

BACKGROUND: Dilated cardiomyopathy (DCM) is characterized by a dilated left ventricular cavity with systolic dysfunction manifested by heart failure. It has been revealed that mutations in genes for cytoskeleton or sarcomere proteins cause DCM. However, the disease-causing mutations can be found only in far less than half of patients with a family history, indicating that there should be other disease genes for DCM. Formin homology 2 domain containing 3 (FHOD3) is a sarcomeric protein expressed in the heart that plays an essential role in sarcomere organization during myofibrillogenesis. The purpose of this study was to explore a possible novel disease gene for DCM. METHODS AND RESULTS: We analyzed 48 Japanese familial DCM patients for mutations in FHOD3, and a missense variant, Tyr1249Asn, which was predicted to modify the 3D structure and damage protein function, was found in a case with adult-onset DCM. Functional studies revealed that the DCM-associated mutation significantly reduced the ability to induce actin dynamics-dependent activation of serum response factor, although no remarkable change in the cellular localization was induced in neonatal rat cardiomyocytes transfected with a mutant construct of FHOD3. CONCLUSIONS: The DCM-associated FHOD3 variant may cause DCM by interfering with actin filament assembly.


Assuntos
Cardiomiopatia Dilatada , Proteínas dos Microfilamentos , Proteínas Musculares , Mutação de Sentido Incorreto , Miócitos Cardíacos/metabolismo , Fator de Resposta Sérica , Adulto , Substituição de Aminoácidos , Animais , Povo Asiático , Cardiomiopatia Dilatada/genética , Cardiomiopatia Dilatada/metabolismo , Células Cultivadas , Forminas , Humanos , Japão , Masculino , Proteínas dos Microfilamentos/genética , Proteínas dos Microfilamentos/metabolismo , Pessoa de Meia-Idade , Proteínas Musculares/genética , Proteínas Musculares/metabolismo , Ratos , Fator de Resposta Sérica/genética , Fator de Resposta Sérica/metabolismo
20.
ESC Heart Fail ; 10(2): 1336-1346, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36725669

RESUMO

AIMS: This study aimed to clarify the relationship between cardiovascular prognosis and left ventricular hypertrophy (LVH) in patients with severe aortic stenosis who underwent transcatheter aortic valve replacement (TAVR) and to investigate the relationship between cardiac sympathetic nerve (CSN) function and these factors using 123 I-metaiodobenzylguanidine scintigraphy. METHODS AND RESULTS: In this single-centre, retrospective observational study, 349 patients who underwent TAVR at our institution between July 2017 and May 2020 were divided into two groups: those with severe LVH pre-operatively [severe LVH (+) group] and those without LVH pre-operatively [severe LVH (-) group]. The rates of freedom from cardiovascular events (cardiovascular death and heart failure hospitalization) were compared. The relationship between changes in left ventricular mass index (LVMi) and changes in delay heart-mediastinum ratio (H/M) from before TAVR to 6 months after TAVR was also investigated. The event-free rate was significantly lower in the severe LVH (+) group (87.1% vs. 96.0%, log-rank P = 0.021). The severe LVH (+) group exhibited a significantly lower delay H/M value, scored by 123 I-metaiodobenzylguanidine scintigraphy, than the severe LVH (-) group (2.33 [1.92-2.67] vs. 2.67 [2.17-3.68], respectively, P < 0.001). Moreover, the event-free rate of post-operative cardiovascular events was lower among patients with a delay H/M value < 2.50 than that among other patients (87.7% vs. 97.2%, log-rank P = 0.012). LVMi was significantly higher (115 [99-130] vs. 90 [78-111] g/m2 , P < 0.001) and delay H/M value was significantly lower (2.53 [1.98-2.83] vs. 2.71 [2.25-3.19], P = 0.025) in the severe LVH (+) group than in the severe LVH (-) group at 6 months after TAVR. Patients with improved LVH at 6 months after TAVR also had increased delay H/M (from 2.51 [2.01-2.81] to 2.67 [2.26-3.02], P < 0.001), whereas those without improved LVH had no significant change in delay H/M (from 2.64 [2.23-3.06] to 2.53 [1.97-3.00], P = 0.829). CONCLUSIONS: Severe LVH before TAVR is a prognostic factor for poor post-operative cardiovascular outcomes. LVH associated with aortic stenosis and CSN function are correlated, suggesting their involvement in LVH prognosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/epidemiologia , Hipertrofia Ventricular Esquerda/complicações , Mediastino/cirurgia , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA