Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 99: 89-95, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37977344

RESUMO

BACKGROUND: In this study, we examined the safety and effectiveness of removing inferior vena cava (IVC) filters with residual acute thrombosis after endovascular therapy. METHODS: A retrospective chart review of 712 patients who underwent retrievable IVC filter implantation between July 2018 and December 2022 was conducted. Residual thrombosis with the IVC filter occurred in 18 patients, and the volume of residual acute thrombosis in the IVC filter exceeded 1 mL in all cases. Angiography was performed to evaluate the size of the residual thrombosis and its position with respect to the filter. The double series filter technique (first filter, infrarenal IVC filter; second filter, suprarenal IVC filter) was used to remove the filter and thrombosis. We summarize the diagnosis, treatment, and surgical experience of these patients. RESULTS: In this study, 16 of 18 patients (88.9%) demonstrated residual thrombosis in the IVC filter. One patient (5.6%) demonstrated thrombosis located both inside and floating above the filter, and one patient (5.6%) demonstrated thrombosis located both inside and underneath the filter. The technical success rate of double series IVC filter retrieval was 100%. Seventeen patients (94.4%) underwent single-stage suprarenal IVC filter retrieval, and one patient (5.6%, 1/18) underwent two-stage retrieval. In terms of residual thrombosis removal, 14 patients (77.7%) achieved complete removal and 4 patients (22.3%) achieved partial removal. Residual thrombosis could not be removed through the sheath in one patient, so femoral vein thrombectomy was performed. No other procedure-related complications were observed. The median follow-up time was 22.5 ± 6.8 months. No recurrence of thrombus symptoms was reported, and B ultrasound and computed tomography demonstrated smooth blood flow in the IVC, renal veins, and pulmonary artery. CONCLUSIONS: For patients with residual acute thrombosis on the IVC filter and in whom there was absence of a more appropriate treatment after percutaneous mechanical thrombectomy or catheter-directed thrombolysis therapy, the double series IVC filter technique was a safe approach to improve the IVC filter retrieval rate in the early stage, as well as for simultaneous residual thrombus removal.


Assuntos
Embolia Pulmonar , Filtros de Veia Cava , Trombose Venosa , Humanos , Embolia Pulmonar/etiologia , Filtros de Veia Cava/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Trombose Venosa/terapia , Remoção de Dispositivo/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
2.
Vascular ; : 17085381241257161, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38805192

RESUMO

OBJECTIVES: The purpose of this study was to investigate the hemodynamic consequences of thoracic endovascular aortic repair which reconstructed left subclavian artery by chimney stent (ch-TEVAR). METHODS: Two patients who underwent thoracic endovascular aortic repair (TEVAR) and left subclavian artery (LSA) reconstruction using chimney stents were selected. Preoperative and postoperative CTA images were collected to reconstruct hemodynamic models for comparing and analyzing blood pressure, blood flow velocity, and wall shear stress in the aortic arch and its major branches. Concurrently, morphological alterations and position of chimney stent were also assessed. RESULTS: After the reconstruction of LSA in ch-TEVAR, no endoleak was seen, but the stent in LSA was compressed. The blood flow velocity of the LSA increased and disordered, the pressure was reduced, and the WSS was increased. Even more, there were a large amount of turbulence found in the LSA of one case, and its LSA was blocked. CONCLUSION: Chimney stent reduces the occurrence of endoleak due to its excellent deformation ability, but the compressed stent has a greater impact on the hemodynamics of LSA and eventually leads to LSA occlusion; in order to keep the LSA unobstructed, it is necessary to pay attention to the position of the chimney stent and keep it straight and do not fold or twist. Chimney stent has little influence on the aortic arch and the rest of the aortic arch branches.

3.
Vascular ; : 17085381241254428, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38797865

RESUMO

BACKGROUND: Carotid body tumors extending to the skull base are hypervascular tumors which are difficult to access using a traditional lateral cervical approach. Preoperative embolization can reduce intraoperative blood loss. CASE PRESENTATION: We report two patients with a carotid body tumor extending to the skull base who underwent preoperative embolization of the external carotid artery using an Amplatzer vascular plug. Two days after embolization, surgical resection was performed. Embolization was successful in both patients and resection proceeded smoothly. Both were discharged on postoperative day 9 without complications. The tumor in each patient was classified as Shamblin group III. Computed tomography angiography of the neck six months after surgery showed patency of the ipsilateral internal carotid artery and no tumor recurrence. CONCLUSION: Preoperative embolization of the external carotid artery using the Amplatzer vascular plug is safe and feasible for patients with carotid body tumors extending to the skull base.

4.
Vascular ; : 17085381231192376, 2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37496151

RESUMO

OBJECTIVES: An analysis was conducted to demonstrate early and midterm outcomes of using adjustable puncture needle-based in situ fenestration (ISF) technique for Ankura aortic stent graft to reconstruct the supra-arch branch in thoracic endovascular aortic repair (TEVAR). METHODS: A retrospective analysis of 68 cases of aortic lesions with insufficient proximal anchoring area admitted to our department from March 2017 to December 2021 was performed. In situ fenestration thoracic endovascular repair (TEVAR) was performed at the same time during the operation. Among them, there were fifty-eight cases of thoracic aortic dissection, seven cases of thoracic aortic aneurysm, and three cases of thoracic aortic ulcer. Intraoperative adjustable puncture with needle was used for the Ankura aorta stent graft to perform ISF and reconstruction of the supra-arch branch. RESULTS: The success rate of ISF was 94.1% (64/68). Only in four cases, attempts were made to create ISF in the left subclavian artery (LSA), and all the four were unsuccessful because of sharp and tortuosity angle. Among them, forty-four cases were only LSA fenestration, and one case was left common carotid artery (LCCA) fenestration + LSA embolism. LSA + left vertebral artery (LVA) fenestration was performed in two cases, LSA fenestration +LCCA chimney was performed in fourteen cases, LCCA + LSA fenestration + innominate artery (INA) chimney was performed in one case, and LCCA fenestration + INA chimney + LSA embolism was performed in two cases. The overall neurologic event rate was 3.1% (spinal cord ischemia 0, with stroke observed in two cases). Postoperatively, one patient (1.6%) died on the third day after TEVAR due to the retrograde dissections. There were four cases of endoleak (6.3%; three type I and one type II). The average follow-up was 29.2 ± 14.4 months, and no patient died during the follow-up period. Three cases of endoleak disappeared, and one case did not increase further. In addition, other two cases of retrograde dissections were observed at 3 and 5 months after TEVAR. Fortunately, they were scheduled for emergency surgery with ascending aorta replacement and improved well. There was only one case of LSA occlusion after ISF which was reconstructed by endovascular treatment. Two patients were found with distal stent graft-induced new entries (dSINE), and TEVAR was performed again during the follow-up period. CONCLUSION: Early and midterm outcomes demonstrated that ISF via the adjustable puncture needle device for the Ankura aorta stent graft is a feasible and effective treatment method, which can achieve high technical success and satisfactory short-term results.

5.
Cir Cir ; 92(3): 338-346, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38862121

RESUMO

OBJECTIVE: The effect of a pre-operative biliary stent on complications after pancreaticoduodenectomy (PD) remains controversial. MATERIALS AND METHOD: We conducted a meta-analysis according to the preferred reporting items for systematic reviews and meta-analyses guidelines, and PubMed, Web of Science Knowledge, and Ovid's databases were searched by the end of February 2023. 35 retrospective studies and 2 randomized controlled trials with a total of 12641 patients were included. RESULTS: The overall complication rate of the pre-operative biliary drainage (PBD) group was significantly higher than the no-PBD group (odds ratio [OR] 1.46, 95% confidence interval [CI] 1.22-1.74; p < 0.0001), the incidence of post-operative delayed gastric emptying was increased in patients with PBD compared those with early surgery (OR 1.21, 95% CI: 1.02-1.43; p = 0.03), and there was a significant increase in post-operative wound infections in patients receiving PBD with an OR of 2.2 (95% CI: 1.76-2.76; p < 0.00001). CONCLUSIONS: PBD has no beneficial effect on post-operative outcomes. The increase in post-operative overall complications and wound infections urges the exact indications for PBD and against routine pre-operative biliary decompression, especially for patients with total bilirubin < 250 umol/L waiting for PD.


OBJETIVO: El efecto de una endoprótesis biliar pre-operatoria sobre las complicaciones después de la pancreaticoduodenectomía sigue siendo controvertido. MATERIALES Y MÉTODO: Se llevó a cabo un metaanálisis siguiendo las directrices PRISMA y se realizaron búsquedas en PubMed, Web of Science Knowledge y la base de datos de Ovid hasta finales de febrero de 2023. Se incluyeron 35 estudios retrospectivos y 2 ensayos controlados aleatorizados, con un total de 12,641 pacientes. RESULTADOS: La tasa global de complicaciones del grupo drenaje biliar pre-operatorio (PBD) fue significativamente mayor que la del grupo no-PBD (odds ratio [OR]: 1.46; intervalo de confianza del 95% [IC 95%]: 1.22-1.74; p < 0.0001), la incidencia de vaciado gástrico retardado posoperatorio fue mayor en los pacientes con PBD en comparación con los de cirugía precoz (OR: 1.21; IC95%: 1.02-1.43; p = 0.03), y hubo un aumento significativo de las infecciones posoperatorias de la herida en los pacientes que recibieron PBD (OR: 2.2; IC 95%: 1.76-2.76; p < 0.00001). CONCLUSIONES: El drenaje biliar pre-operatorio no tiene ningún efecto beneficioso sobre el resultado posoperatorio. El aumento de las complicaciones posoperatorias globales y de las infecciones de la herida urge a precisar las indicaciones de PBD y a desaconsejar la descompresión biliar pre-operatoria sistemática, en especial en pacientes con bilirrubina total inferior a 250 µmol/l en espera de pancreaticoduodenectomía.


Assuntos
Drenagem , Pancreaticoduodenectomia , Complicações Pós-Operatórias , Cuidados Pré-Operatórios , Stents , Humanos , Pancreaticoduodenectomia/efeitos adversos , Cuidados Pré-Operatórios/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Esvaziamento Gástrico , Ampola Hepatopancreática , Neoplasias Pancreáticas/cirurgia , Neoplasias do Ducto Colédoco/cirurgia
6.
J Hepatocell Carcinoma ; 10: 1435-1443, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37691972

RESUMO

Purpose: In the study, patients with unresectable hepatocellular carcinoma (uHCC) were treated with either transcatheter chemoembolization (TACE) combined with lenvatinib and PD-(L)1 inhibitor (TACE-L-P) or TACE combined with lenvatinib (TACE-L). We compared the efficacy and safety of TACE-L-P with TACE-L, and analyzed factors affecting prognosis. Materials and Methods: A total of 122 patients were treated with either TACE-L-P (n = 64) or TACE-L (n = 58), and their data was collected and analyzed. We assessed tumor response, progression-free survival (PFS), prognostic factors for PFS and adverse events (AEs) to compare the efficacy and safety of TACE-L-P with TACE-L for patients with uHCC. Results: TACE-L-P group's patients had a better objective response rate (ORR) (57.8% vs 41.4%, P = 0.047) and a better disease control rate (93.7% vs 81%, P = 0.013), as long as a longer median progression-free survival (PFS) (8 months vs 4.6 months, HR: 0.461; 95% CI: [0.314-0.675]; P = 0.001) than TACE-L group's patients. According to multivariate analysis, independent prognostic factors for PFS included treatment option (TACE-L-P / TACE-L; RH = 0.461; 95% CI [0.314-0.675]; P = 0.001), PVTT (Yes/No; RH =1 0.599;95% CI [1 0.095-2 0.336]; P=0 0.017), extrahepatic metastasis (Yes/No; RH=1 0.847;95% CI [1 0.176 -2 0.909]; P=0 0.008). AEs in TACE-L-P group was similar with TACE-L group. Conclusion: TACE-L-P has more promising clinical outcomes in patients with uHCC than TACE-L, and their safety is similar.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA