Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Clin Transplant ; 32(1)2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29112278

RESUMO

Cytomegalovirus (CMV) pneumonia causes major morbidity and mortality. Its diagnosis requires demonstration of viral cytopathic changes in tissue, entailing risks of lung biopsy. This study aimed to determine CMV viral load (VL) thresholds in bronchoalveolar lavage fluid (BALF) for diagnosis of CMV pneumonia in immunocompromised patients. CMV VL in BALF was studied in 17 patients (83% transplant recipients) and 21 control subjects with and without CMV pneumonia, respectively, using an FDA-approved PCR assay (Cobas® AmpliPrep/Cobas TaqMan® CMV Test, Roche Molecular Systems, Inc.) calibrated to the WHO International Standard for CMV DNA (NIBSC: 09/162). Receiver operating characteristic curve analysis produced a BALF CMV VL threshold of 34 800, IU/mL with 91.7% sensitivity and 100.0% specificity for diagnosis of possible, probable, and proven CMV pneumonia in transplant patients, while a threshold of 656 000 IU/mL yielded 100% sensitivity and specificity among biopsy-proven cases. For all immunocompromised patients, a VL threshold of 274 IU/mL was selected. VL thresholds also were normalized to BALF cell count yielding a threshold of 0.32 IU/106 cells with 91.7% sensitivity and 90.5% specificity for possible, probable, and proven CMV pneumonia in transplant recipients. Monitoring CMV VL in BALF may be a less invasive method for diagnosing CMV pneumonia in immunocompromised patients.


Assuntos
Líquido da Lavagem Broncoalveolar/virologia , Infecções por Citomegalovirus/diagnóstico , Citomegalovirus/genética , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Hospedeiro Imunocomprometido , Transplante de Órgãos/efeitos adversos , Pneumonia Viral/diagnóstico , Adulto , Idoso , Citomegalovirus/isolamento & purificação , Infecções por Citomegalovirus/genética , Infecções por Citomegalovirus/virologia , DNA Viral/genética , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/genética , Pneumonia Viral/virologia , Prognóstico , Carga Viral
2.
J Clin Microbiol ; 52(7): 2689-93, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24829247

RESUMO

Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved.


Assuntos
Testes Diagnósticos de Rotina/métodos , Laboratórios/organização & administração , Técnicas de Diagnóstico Molecular/métodos , Testes Diagnósticos de Rotina/economia , Testes Diagnósticos de Rotina/normas , Humanos , Laboratórios/economia , Laboratórios/normas , Técnicas de Diagnóstico Molecular/economia , Técnicas de Diagnóstico Molecular/normas , Fluxo de Trabalho
3.
J Clin Microbiol ; 51(1): 95-100, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23100352

RESUMO

The Abbott HBV RUO Sequencing assay (Abbott Molecular Inc., Des Plaines, IL), which combines automated sample processing, real-time PCR, and bidirectional DNA sequencing, was evaluated for detection of nucleos(t)ide analogue (NA) resistance-associated mutations located in the hepatitis B virus (HBV) polymerase (Pol) gene. Interpretive software from the assay manufacturer was modified to allow interrogation of the overlapping HBV surface (S) gene sequence for HBV genotype determination and detection of immune escape mutations. Analytical sensitivity (detection and sequencing) of the assay was determined to be 103.9 IU/ml (95% confidence interval [CI], 80.0 to 173.3) for HBV genotype A. Testing of commercially available HBV genotype panels consisting of 23 individual members yielded complete agreement between expected results and results obtained from the laboratory-developed HBV genotype library. Excellent specificity was observed among clinical specimens with serologic or molecular markers for various unrelated blood-borne viruses (n = 6) and sera obtained from healthy, HBV-negative blood donors (n = 20). Retrospectively selected clinical specimens tested by a commercial reference laboratory HBV sequencing assay (n = 54) or the Trugene HBV Genotyping kit (n = 7) and the Abbott HBV RUO Sequencing assay showed minor differences in detection and reporting of NA resistance-associated mutations in 7 of 61 (11.5%) specimens but complete agreement of genotype results. The Abbott HBV RUO Sequencing assay provided a convenient and efficient assay workflow suitable for routine clinical laboratory use, with the flexibility to be modified for customized detection of NA resistance-associated mutations, HBV genotype determination, and detection of immune escape mutations from a single contiguous HBV sequence.


Assuntos
Farmacorresistência Viral , Vírus da Hepatite B/genética , Hepatite B/virologia , Técnicas de Diagnóstico Molecular/métodos , Software , Virologia/métodos , Automação Laboratorial/métodos , DNA Viral/química , DNA Viral/genética , Vírus da Hepatite B/efeitos dos fármacos , Vírus da Hepatite B/isolamento & purificação , Humanos , Mutação de Sentido Incorreto , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Análise de Sequência de DNA/métodos
4.
J Clin Microbiol ; 49(8): 3040-3, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21613437

RESUMO

Hepatitis C virus (HCV) genotype (GT) distribution and frequency were studied among 22,407 unique specimens tested at a national reference testing laboratory. Subjects with HCV GT 3 were younger (P < 0.0001) than those with GT 1, 2, or 4, and the regional frequencies of HCV GT 2 and 3 ranged from 19.9% to 29.2%.


Assuntos
Hepacivirus/classificação , Hepacivirus/genética , Hepatite C/epidemiologia , Hepatite C/virologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Genótipo , Hepacivirus/isolamento & purificação , Humanos , Masculino , Pessoa de Meia-Idade , Epidemiologia Molecular , Prevalência , Estados Unidos/epidemiologia , Adulto Jovem
5.
J Clin Microbiol ; 48(3): 969-71, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20042629

RESUMO

No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Infecções por HIV/virologia , HIV-1/genética , Humanos , Sensibilidade e Especificidade
6.
J Mol Diagn ; 22(8): 968-974, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32565306

RESUMO

Clinical molecular laboratory professionals are at the frontline of the response to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, providing accurate, high-quality laboratory results to aid in diagnosis, treatment, and epidemiology. In this role, we have encountered numerous regulatory, reimbursement, supply-chain, logistical, and systems challenges that we have struggled to overcome to fulfill our calling to provide patient care. In this Perspective from the Association for Molecular Pathology Infectious Disease Subdivision Leadership team, we review how our members have risen to these challenges, provide recommendations for managing the current pandemic, and outline the steps we can take as a community to better prepare for future pandemics.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Pandemias , Patologia Molecular , Pneumonia Viral/epidemiologia , COVID-19 , Infecções por Coronavirus/diagnóstico , Humanos , Liderança , Técnicas de Diagnóstico Molecular , Patologia Molecular/organização & administração , Pneumonia Viral/diagnóstico , SARS-CoV-2 , Sociedades Médicas , Estados Unidos/epidemiologia
7.
J Clin Microbiol ; 47(4): 889-95, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19193837

RESUMO

The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay (ART) and the Cobas AmpliPrep/Cobas TaqMan HIV-1 test (CTM) are commercially available assays for quantification of HIV-1 RNA in plasma. We evaluated performance characteristics, workflow, throughput, reliability, and direct costs of these assays. Both assays yielded good correlation of quantitative results (r = 0.95) among clinical specimens, with a mean difference of -0.34 log(10) copies/ml. Testing of healthy donor plasma specimens yielded "target not detected" results by ART, with "HIV-1 RNA detected, <40 copies/ml" results for 3.3% (3 of 90 samples) of these specimens by CTM. Both the m2000sp/m2000rt (ART) and docked CAP/CTM96 (CTM) instrument systems were capable of operating with continuous, uninterrupted workflow. When daily maintenance and cleaning were included, ART and CTM run durations (5 h 52 min and 6 h 4 min, respectively) and hands-on times (53 min and 46 min, respectively) were similar for a run batch size of 24. While ART was more flexible in terms of run batch size, CTM required fewer user interventions and consistently produced higher specimen throughput rates at 8, 16, and 24 h. Assay run failure rates were 6.3% (1 of 16 runs) and 4.2% (1 of 24 runs) for ART and CTM, respectively (P = 1.000), with invalid specimen result rates of 1.0% (5 of 495 specimens) and 2.8% (11 of 399 specimens), respectively (P = 0.073). Direct reagent and consumable costs for each assay were comparable (difference of <10%). In selecting an assay for implementation, laboratories should consider how various assay and instrument features might impact laboratory operation and patient care.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/economia , Técnicas de Diagnóstico Molecular/métodos , Carga Viral/métodos , Automação/métodos , Doadores de Sangue , Humanos , RNA Viral/sangue , Fatores de Tempo
8.
J Clin Microbiol ; 47(7): 2317-20, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19420174

RESUMO

A retrospective examination of quantitation standard growth curves associated with 1,000 unique clinical serum specimens tested by a laboratory-developed TaqMan hepatitis C virus analyte-specific reagent-based assay revealed anomalous growth curves associated with 0.40% (95% confidence interval, 0.11% to 1.00%) of these specimens.


Assuntos
Erros de Diagnóstico , Hepacivirus/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , RNA/isolamento & purificação , Kit de Reagentes para Diagnóstico , Carga Viral/métodos , Hepacivirus/genética , Humanos , RNA/genética
9.
J Clin Virol ; 99-100: 97-100, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29396354

RESUMO

BACKGROUND: Hepatitis virus C (HCV) genotype (GT) determination and subtype (ST) differentiation (1a versus 1b) remain important for the selection of appropriate direct-acting antiviral (DAA) therapy. OBJECTIVES: This study is a retrospective comparison of HCV GT and ST result distribution when using the Abbott RealTime HCV Genotype II assay (HCVGT II) alone and in combination with the Abbott RealTime HCV Genotype Plus RUO assay (HCVGT Plus) for routine testing of clinical serum specimens at a reference laboratory. STUDY DESIGN: HCVGT II results of specimens tested from June 2014 through January 2016 (period 1) were compared with combined results from HCVGT II and HCVGT Plus (HCVGT II/Plus) performed from January 2016 through January 2017 (period 2). RESULTS: A total of 44,127 and 25,361 specimens were tested during periods 1 and 2, respectively. Use of HCVGT II/Plus significantly reduced the frequency of GT 1 results without ST (0.4%) when compared to preliminary HCVGT II results during period 2 (5.3%; p < 0.01) and final HCVGT II results in period 1 (5.5%; p < 0.01). HCVGT II/Plus also resulted in GT 6 reactivity in 38 specimens with results of "HCV detected" (n = 17) or GT 1 (n = 21) following initial HCVGT II testing during period 2. CONCLUSIONS: When compared to the use of HCVGT II alone, HCVGT II/Plus significantly reduced the frequency of GT 1 without ST results observed in a large reference laboratory, while also enabling the identification of HCV GT 6.


Assuntos
Técnicas de Genotipagem/métodos , Hepacivirus/genética , Hepatite C/diagnóstico , Hepatite C/virologia , Reação em Cadeia da Polimerase em Tempo Real , Regiões 5' não Traduzidas/genética , Genótipo , Hepacivirus/classificação , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Análise de Sequência de DNA , Testes Sorológicos , Proteínas do Core Viral/genética , Carga Viral , Proteínas não Estruturais Virais/genética
10.
J Clin Virol ; 37(3): 195-8, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16973410

RESUMO

BACKGROUND: The AMPLICOR HIV-1 DNA Test, version 1.5 (AMP HIV-1 DNA 1.5), is a new commercially available PCR assay for the detection of human immunodeficiency virus type 1 (HIV-1) proviral DNA in human whole blood. OBJECTIVE: This study evaluates the performance characteristics of the assay following automated sample processing by the MagNA Pure LC instrument (MP). STUDY DESIGN: Analytical sensitivity and reproducibility were assessed by testing replicate HIV-1 DNA dilution panels over 5 days. Clinical sensitivity and specificity were studied among 28 HIV-1 DNA-positive clinical specimens, 60 specimens from healthy blood donors, and 63 specimens from HIV-1-seropositive patients with HIV-1 RNA plasma levels ranging from <50 to >100,000 copies/mL. RESULTS: Following MP sample processing, the assay yielded an analytical sensitivity (95% detection rate) of 66.3 copies/mL (95% CI, 50.7-106.8), with clinical sensitivity and specificity of 100%. CONCLUSIONS: MP is a reliable, labor-saving platform capable of processing specimens for AMP HIV-1 DNA 1.5. When combined with MP sample processing, AMP HIV-1 DNA 1.5 is a sensitive and reproducible assay for the detection of HIV-1 DNA in clinical whole blood specimens. However, the current AMP HIV-1 DNA 1.5 kit configuration may result in inefficient utilization of reagents.


Assuntos
DNA Viral/sangue , HIV-1/genética , Provírus/isolamento & purificação , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , DNA Viral/isolamento & purificação , Processamento Eletrônico de Dados , HIV-1/isolamento & purificação , Humanos , Lactente , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade
11.
J Clin Virol ; 37(3): 218-21, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16973411

RESUMO

BACKGROUND: INNO-LiPA HBV Genotyping (LiPA HBV GT) and INNO-LiPA HBV PreCore (LiPA HBV PC) are commercially available assays for hepatitis B virus (HBV) characterization. These assays are labor-intensive and may be prone to exogenous DNA contamination due to their use of nested PCR amplification procedures and lack of contamination control measures. OBJECTIVE: Standardized, single-round INNO-LiPA PCR amplification protocols incorporating uracil N-glycosylase and automated sample processing by the MagNA Pure LC instrument were evaluated. STUDY DESIGN: HBV standards containing 10,000, 1000, 100, 10, and 0 IU/mL were analyzed to determine the analytical sensitivity and reproducibility of these modified procedures. One hundred clinical serum specimens with viral titers ranging from 390 to 16,900,000 IU/mL were tested by modified LiPA HBV GT, while 34 specimens with viral titers ranging from 378 to 11,600,000 IU/mL were tested by modified LiPA HBV PC. RESULTS: Modified LiPA HBV GT and LiPA HBV PC each yielded analytical sensitivities of 100% at an HBV DNA level of 1000 IU/mL and 90% at a level of 100 IU/mL. Among clinical specimens, success rates for both INNO-LiPA procedures were > or =94%. CONCLUSIONS: Both modified INNO-LiPA procedures were sensitive and reproducible, with improved efficiency and suitability for routine laboratory use.


Assuntos
DNA Viral/análise , Vírus da Hepatite B/genética , Hepatite B/diagnóstico , Reação em Cadeia da Polimerase/métodos , Genótipo , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Clin Virol ; 34(2): 155-7, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16023890

RESUMO

BACKGROUND: The current manual sample processing method recommended for use with the TRUGENE HBV Genotyping Kit (TRUGENE HBV; Bayer HealthCare LLC, Tarrytown, NY) is labor-intensive and may be prone to specimen cross-contamination. Recent evaluations of the MagNA Pure LC (MP; Roche Applied Science, Indianapolis, IN) suggest that it is suitable for automated, contamination-free extraction and purification of viral nucleic acids from large-volume (1.0 mL) serum or plasma specimens. OBJECTIVES: We evaluated the MP Total Nucleic Acid Isolation Kit--Large Volume (Roche Applied Science) in conjunction with TRUGENE HBV to establish the analytical sensitivity (threshold titer) of the assay, in HBV DNA International Units (IU)/mL, for obtaining consistent, interpretable sequence data from TRUGENE HBV. STUDY DESIGN: HBV analytical standards, prepared as 10 replicates (1.0 mL each) at each of the following concentrations: 200, 1000, 5000, and 10,000 IU/mL, were processed by MP and analyzed by TRUGENE HBV according to manufacturer's instructions. Performance of TRUGENE HBV used in conjunction with MP sample processing was evaluated further using 22 clinical serum specimens containing low titers of HBV DNA. RESULTS: All replicates of HBV analytical standards at 1000, 5000, and 10,000 IU/mL yielded interpretable TRUGENE HBV sequences, whereas interpretable sequences were obtained in 90% (9 of 10) of the replicates at 200 IU/mL. TRUGENE HBV sequences were interpretable in 86% (19 of 22) of the clinical specimens studied. CONCLUSIONS: MP sample processing is efficient and suitable for use with TRUGENE HBV. When combined with MP sample processing, TRUGENE HBV yielded interpretable sequences from HBV analytical standards and clinical serum specimens with HBV DNA titers of > or =200 IU/mL.


Assuntos
DNA Viral/isolamento & purificação , Vírus da Hepatite B/classificação , Vírus da Hepatite B/genética , Virologia/métodos , Genótipo , Vírus da Hepatite B/isolamento & purificação , Humanos , Sensibilidade e Especificidade , Soro/virologia
14.
Diagn Microbiol Infect Dis ; 49(1): 59-61, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15135502

RESUMO

Use of the MagNA Pure LC Total Nucleic Acid Isolation Kit-Large Volume in conjunction with the TRUGENE HIV-1 Genotyping Kit yielded consistent, interpretable sequence data from 1-mL plasma preparations containing HIV-1 RNA concentrations of > or =400 copies/mL. This finding was confirmed in 18 of 24 low-titer clinical specimens.


Assuntos
HIV-1/genética , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Automação , Genótipo , HIV-1/isolamento & purificação , Humanos , RNA Viral/análise , Estudos de Amostragem , Sensibilidade e Especificidade
16.
Diagn Microbiol Infect Dis ; 75(4): 440-2, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23428458

RESUMO

Testing of clinical plasma specimens by the COBAS AmpliPrep/COBAS TaqMan CMV Test (CAP/CTM CMV), COBAS AMPLICOR CMV MONITOR Test (CAM CMV), and a laboratory-developed assay using analyte-specific reagents (LC CMV) demonstrated substantial result bias for CAP/CTM CMV versus CAM CMV (r = 0.436) and CAP/CTM CMV versus LC CMV (r = 0.773).


Assuntos
Infecções por Citomegalovirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Transplante , Carga Viral/métodos , Virologia/métodos , Infecções por Citomegalovirus/virologia , Humanos
17.
J Clin Microbiol ; 45(9): 3101-4, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17634308

RESUMO

The COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5 (CAP/CA), and the COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5, were compared. CAP/CA reduced and consolidated labor while modestly increasing assay throughput without increased failure rates or direct costs, regardless of batch size and assay format.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Virologia/métodos , HIV-1/genética , Humanos , Técnicas de Diagnóstico Molecular/economia , Sensibilidade e Especificidade , Virologia/economia
18.
J Clin Microbiol ; 44(4): 1490-4, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16597881

RESUMO

TaqMan hepatitis B virus (HBV) analyte-specific reagent (ASR; Roche Molecular Systems, Inc., Branchburg, NJ) is designed for the quantification of HBV DNA in serum or plasma. The performance characteristics of TaqMan HBV ASR following automated sample processing with the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, IN) were evaluated in this study. Analytical sensitivity and precision were assessed with commercially available HBV standards, while clinical serum specimens from HBsAg-seropositive patients and healthy blood donors were used to determine clinical sensitivity, specificity, and correlation with other commercially available assays. Analytical studies yielded a limit of detection of 2.4 IU/ml, with good linearity and correlation (R(2) = 0.9958) with expected HBV DNA titers over a wide range (6.0 x 10(0) to 2.1 x 10(8) IU/ml). Clinical sensitivity and specificity of the assay combined with automated sample processing were both 100%. Comparison of TaqMan HBV ASR and VERSANT HBV DNA 3.0 assay (bDNA; Bayer HealthCare LLC, Tarrytown, NY) results among clinical specimens yielded good correlation (R(2) = 0.9237), with a mean difference in titer of -0.213 log(10) IU/ml (95% confidence interval, -0.678 to 1.10 log(10) IU/ml). The overall test failure rate was 2.0% among 204 clinical serum specimens tested. Total time required for MP sample processing and automated postelution handling of 24 samples was 224 min, with 57 min of actual hands-on time. MP is a reliable, labor-saving platform suitable for use with TaqMan HBV ASR, providing sensitive and accurate quantification of HBV DNA levels over a range of 8 log(10) IU/ml.


Assuntos
DNA Viral/análise , Vírus da Hepatite B/fisiologia , Virologia/métodos , Vírus da Hepatite B/genética , Vírus da Hepatite B/isolamento & purificação , Humanos , Indicadores e Reagentes , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade , Soro/virologia , Taq Polimerase
19.
J Clin Microbiol ; 44(2): 318-23, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16455877

RESUMO

The Invader 1.0 assay (Invader HCV Genotyping Assay, version 1.0; Third Wave Technologies, Inc., Madison, WI) has been developed for the rapid differentiation of hepatitis C virus (HCV) genotypes 1 to 6 based on sequence variation within the HCV 5' noncoding (NC) region. In the present study, we evaluated the compatibility of Invader 1.0 with the COBAS MONITOR (COBAS AMPLICOR HCV MONITOR Test, version 2.0; Roche Molecular Systems, Inc., Branchburg, NJ), COBAS AMPLICOR (COBAS AMPLICOR Hepatitis C Virus Test, version 2.0; Roche Molecular Systems, Inc.), and COBAS TaqMan (COBAS TaqMan HCV Test; Roche Molecular Systems, Inc.) assays. The minimum HCV RNA titers required for successful HCV genotyping (>/=90% success rate) were 1,000 IU/ml for COBAS MONITOR, 100 IU/ml for COBAS AMPLICOR, and 10 IU/ml for COBAS TaqMan. Invader 1.0 results obtained from unpurified COBAS TaqMan amplification products of 111 retrospectively selected clinical serum specimens (genotypes 1 to 6, with virus titers ranging from 15.1 to 2.1 x 10(7) IU/ml) showed 98% concordance with results obtained from the TRUGENE HCV 5' NC Genotyping Kit (Bayer HealthCare LLC, Tarrytown, NY), used in conjunction with COBAS AMPLICOR. Although the assay is sensitive, accurate, and easy to perform, additional optimization of the Invader 1.0 interpretive software (Invader Data Analysis Worksheet) may be necessary to reduce potential misidentification of HCV genotypes in low-titer specimens. In summary, Invader 1.0 is compatible with a variety of commercially available PCR-based HCV 5' NC region amplification assays and is suitable for routine HCV genotyping in clinical laboratories.


Assuntos
Regiões 5' não Traduzidas/genética , Hepacivirus/classificação , Hepacivirus/genética , Hepatite C/virologia , Técnicas de Amplificação de Ácido Nucleico , Kit de Reagentes para Diagnóstico , Variação Genética , Genótipo , Hepacivirus/isolamento & purificação , Humanos , RNA Viral/sangue , Sensibilidade e Especificidade , Software
20.
J Clin Microbiol ; 43(1): 293-8, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15634985

RESUMO

The COBAS TaqMan HCV Test (TaqMan HCV; Roche Molecular Systems Inc., Branchburg, N.J.) for hepatitis C virus (HCV) performed on the COBAS TaqMan 48 Analyzer (Roche Molecular Systems) currently relies on a manual sample processing method. Implementation of an automated sample processing method would facilitate the clinical use of this test. In this study, we evaluated the performance characteristics of TaqMan HCV following automated sample processing by the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, Ind.). The analytical sensitivity of TaqMan HCV following sample processing by MP was 8.1 IU/ml (95% confidence interval, 6.1 to 15.2). The assay showed good linearity (R(2) = 0.99) across a wide range of HCV RNA levels (25 to 5 x 10(6) IU/ml), with coefficients of variation ranging from 10% to 46%. Among 83 clinical specimens, the sensitivity and specificity of TaqMan HCV were 100% and 95%, respectively, when compared to the COBAS AMPLICOR hepatitis C virus test, version 2.0 (COBAS AMPLICOR; Roche Molecular Systems), with TaqMan HCV detecting two more HCV RNA-positive specimens than COBAS AMPLICOR. Both specimens were confirmed to be HCV RNA positive by the VERSANT HCV RNA qualitative test (Bayer HealthCare LLC, Tarrytown, N.Y.). There was also strong correlation (R(2) = 0.95) and good agreement between the results from TaqMan HCV and the VERSANT HCV RNA 3.0 assay (bDNA) (Bayer HealthCare LLC) among a group of 93 clinical specimens. The MP is a versatile, labor-saving sample processing platform suitable for reliable performance of TaqMan HCV.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/diagnóstico , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/sangue , Automação , Hepacivirus/classificação , Hepacivirus/genética , Hepatite C/virologia , Humanos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase , RNA Viral/isolamento & purificação , Sensibilidade e Especificidade , Taq Polimerase , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA