RESUMO
OBJECTIVE: Local Liquid drug (LLD) delivery devices have recently emerged as a novel approach to treat peripheral arterial disease. This systemic review aims to identify and evaluate the clinical utility of the most commonly used delivery devices. METHODS: A systemic review was performed using the Medical Subjects Heading terms of "drug delivery," "liquid," "local," and "cardiovascular disease" in PubMed, Google Scholar, and Scopus. RESULTS: Four commonly used delivery devices were identified, including (1) the Bullfrog Micro-Infusion Device, (2) the ClearWay RX Catheter, (3) the Occlusion Perfusion Catheter, and (4) the Targeted Adjustable Pharmaceutical Administration. All have shown to successfully deliver liquid therapeutic into the target lesion and have exhibited favorable safety and efficacy profiles in preclinical and clinical trials. The LLD devices have the ability to treat very long or multiple lesions with a single device, providing a more economical option. The safety profile in LLD clinical studies is also favorable in view of recent concerns regarding adverse events with crystalline-paclitaxel-coated devices. CONCLUSION: There is clear clinical evidence to support the concept of local liquid delivery to treat occlusive arterial disease. CLINICAL IMPACT: The 'leave nothing behind' strategy has been at the forefront of the most recent innovations in the field of interventional cardiology and vascular interventions. Although drug coated balloons have overcome limitations associated with plain old balloon angioplasty and peripheral stents, recent safety concerns and cost considerations have impacted their usage. In this review, various liquid drug delivery devices are presented, showcasing their capabilities and success in both preclinical and clinical settings. These innovative liquid delivery devices, capable of targeted delivery and their ability to be re-used for multiple treatment sites, may provide solutions for current unmet clinical needs.
RESUMO
BACKGROUND: Drug-coated balloons (DCBs), which deliver anti-proliferative drugs with the aid of excipients, have emerged as a new endovascular therapy for the treatment of peripheral arterial disease. In this study, we evaluated the use of keratose (KOS) as a novel DCB-coating excipient to deliver and retain paclitaxel. METHODS: A custom coating method was developed to deposit KOS and paclitaxel on uncoated angioplasty balloons. The retention of the KOS-paclitaxel coating, in comparison to a commercially available DCB, was evaluated using a novel vascular-motion simulating ex vivo flow model at 1 h and 3 days. Additionally, the locoregional biological response of the KOS-paclitaxel coating was evaluated in a rabbit ilio-femoral injury model at 14 days. RESULTS: The KOS coating exhibited greater retention of the paclitaxel at 3 days under pulsatile conditions with vascular motion as compared to the commercially available DCB (14.89 ± 4.12 ng/mg vs. 0.60 ± 0.26 ng/mg, p = 0.018). Histological analysis of the KOS-paclitaxel-treated arteries demonstrated a significant reduction in neointimal thickness as compared to the uncoated balloons, KOS-only balloon and paclitaxel-only balloon. CONCLUSIONS: The ability to enhance drug delivery and retention in targeted arterial segments can ultimately improve clinical peripheral endovascular outcomes.
Assuntos
Antineoplásicos/administração & dosagem , Materiais Revestidos Biocompatíveis , Portadores de Fármacos/química , Sistemas de Liberação de Medicamentos , Ceratose , Angioplastia com Balão , Animais , Fármacos Cardiovasculares/administração & dosagem , Avaliação Pré-Clínica de Medicamentos , Imuno-Histoquímica , Paclitaxel/administração & dosagem , Doença Arterial Periférica/tratamento farmacológico , Doença Arterial Periférica/etiologia , Doença Arterial Periférica/metabolismo , Doença Arterial Periférica/patologiaRESUMO
BACKGROUND: Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. OBJECTIVE: The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. METHODS AND RESULTS: Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. CONCLUSION: Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo.
Assuntos
Angioplastia Coronária com Balão/instrumentação , Antineoplásicos Fitogênicos/uso terapêutico , Plásticos Biodegradáveis/uso terapêutico , Doença das Coronárias/terapia , Stents Farmacológicos , Imunossupressores/uso terapêutico , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Animais , Materiais Revestidos Biocompatíveis/uso terapêutico , Modelos Animais de Doenças , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/classificação , Análise de Falha de Equipamento/métodos , Teste de Materiais/métodos , Modelos Anatômicos , Coelhos , Fatores de TempoRESUMO
OBJECTIVES: This study was designed to evaluate the safety of a novel drug-coated balloon (DCB) with 2 µg/mm(2) paclitaxel and a carrier comprised of polysorbate and sorbitol in a swine femoral artery model. BACKGROUND: DCB have emerged as a therapeutic alternative in the treatment of peripheral vascular disease. METHODS: The femoral arteries of 45 swine were treated with low pressure balloon inflation either 1× clinical dose (single inflation, 2 µg/mm(2) paclitaxel) or 4× dose (2 DCBs, each with 4 µg/mm(2) paclitaxel) or control (uncoated) balloons. The treated arteries, downstream vascular beds, and organs were assessed histologically at 28, 90, and 180-days. Twenty-four swine were treated with 1× dose for pharmacokinetic analysis through 30 days. RESULTS: Arterial tissue paclitaxel concentration was 58.8 ± 54.2 ng/mg at 1-hr and 0.3 ± 0.4 ng/mg at 30 days, whereas plasma paclitaxel could no longer be detected after 1 day. The treated arteries displayed minimal endothelial loss, fibrin deposition, and inflammation with long-term dose-dependent drug effect (medial smooth muscle cell loss) peaking at 90 days for both 1× (1.1 ± 1.4 vs. 0.0 ± 0.0, P = 0.008) and 4× dose (2.0 ± 1.5 vs. 0.0 ± 0.0, P < 0.001). In parallel, healing of the treated arteries was evident by significantly greater medial proteoglycan and collagen deposition at 180 days. No evidence of ischemia from downstream emboli or systemic toxicity was observed even for 4× DCB groups. CONCLUSIONS: The findings indicate desired pharmacologic levels with biologic effects at early and healing at late time points in the treated arteries, without evidence of significant downstream emboli or systemic toxicity, consistent with safety of the Lutonix DCB.
Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/farmacocinética , Materiais Revestidos Biocompatíveis , Artéria Femoral/efeitos dos fármacos , Paclitaxel/administração & dosagem , Paclitaxel/farmacocinética , Dispositivos de Acesso Vascular , Animais , Fármacos Cardiovasculares/sangue , Desenho de Equipamento , Artéria Femoral/metabolismo , Artéria Femoral/patologia , Modelos Animais , Paclitaxel/sangue , Polissorbatos , Punções , Sorbitol , Sus scrofa , Cicatrização/efeitos dos fármacosRESUMO
Vascular hemostasis after venous and arterial access in cardiovascular procedures remains a challenge. As sheath size gets larger for structural heart and vascular procedures, no dedicated closure devices exist that can overcome all the challenges of achieving vascular hemostasis, in particular on the venous side. Efficiently and reliably ensuring hemostasis at the access point is crucial for enhancing the safety of a procedure. Historically, hemostasis relied on manually compressing venous access sites. However, the shift towards larger sheaths and the more frequent use of continuous anticoagulation has strained this approach. Achieving hemostasis solely through compression in these scenarios demands heightened vigilance and prolonged application, resulting in increased patient discomfort and extended immobility. Consequently, manual compression may consume more time for healthcare providers and contribute to bed occupancy in hospitals. This review article summarizes the development of the SiteSeal® Vascular Closure Device, a novel leave-nothing-behind approach to achieve hemostasis. The introduction of this technology has provided clinicians with a safer and more effective way to achieve immediate hemostasis, facilitate early ambulation, and enable earlier discharges with fewer access site complications compared with traditional manual compression.
RESUMO
Currently, there are no ex vivo systems that can model the motion of peripheral arteries and allow for the evaluation of pharmacokinetics (PK) of endovascular devices. The objective of this study was to develop a novel peripheral simulating bioreactor system to evaluate drug pharmacokinetics of stents. We utilized 3D-printed and off-the-shelf components to construct a peripheral-simulating bioreactor system capable of mimicking the motion of peripheral arteries. Servo motors were primarily used to shorten/elongate, twist, and bend explanted porcine carotid arteries. To evaluate the pharmacokinetics in the bioreactor, drug-eluting stents were deployed within explanted arteries and subjected to vascular motion along with pulsatile flow conditions. Following 30 min and 24 h, the arteries were removed, and paclitaxel levels were measured. Scanning electron microscopy was also performed to evaluate the stent surface. Arterial paclitaxel levels of the stent-treated arteries were found to be higher at 30 min than at 24 h following pulsatile and no vascular motion and even higher at 24 h following pulsatile flow and vascular motion. The residual drug on the stent significantly decreased from 30 min to 24 h. Scanning electron microscopy confirmed the loss of paclitaxel coating at 24 h and greater disturbance in stents under peripheral motion versus pulsatile only. This system represents the first ex vivo system to determine the PK of drug-eluting stents under physiological flow and vascular motion conditions. This work provides a novel system for a quick and inexpensive preclinical tool to study acute drug tissue concentration kinetics of drug-releasing interventional vascular devices designed for peripheral applications.
RESUMO
Introduction: Sirolimus is currently being explored as an alternative drug to paclitaxel for the treatment of peripheral artery disease (PAD). To date, sirolimus has only been used as drug coatings for stents and balloons and no studies have yet demonstrated the delivery of sirolimus in liquid form. The purpose of this pilot study was to investigate the feasibility of the delivery of liquid sirolimus into arterial segments in a benchtop peripheral artery bioreactor. Methods: The feasibility to deliver liquid therapy was first tested on four drug delivery devices using a fluorescently tagged liquid drug and an ex vivo porcine artery benchtop model. The four devices included the Bullfrog micro-infusion device, ClearWay RX catheter, Occlusion perfusion catheter (OPC), and the targeted adjustable pharmaceutical administration system (TAPAS). Penetration of the fluorescently tagged drug was measured via microscopic imaging and quantification of the depth of drug penetration into all device-treated tissue. Based on the penetration outcome, we then selected a single device to deliver liquid sirolimus into the ex vivo porcine artery model undergoing physiological flow and pressure conditions. The liquid sirolimus-treated arteries were collected from the ex vivo bioreactor at 1- and 24-hour post-delivery and arterial drug retention analyzed by liquid chromatography-tandem mass spectrometry. Results: Fluorescent microscopy demonstrated that drug delivery with the OPC had greater drug penetration into the medial wall as compared to other devices (OPC: 234 ± 161â µm; TAPAS: 127 ± 68â µm; ClearWay: 118 ± 77â µm; Bullfrog: 2.12 ± 3.78â µm; p = 0.098). The results of the ex vivo flow-circuit bench top model showed that the OPC device successfully delivered the liquid sirolimus at 1-hour (5.17 ± 4.48â ng/mg) and 24-hour (0.78 ± 0.55â ng/mg). Conclusions: These results demonstrate for the first time the ability to deliver liquid sirolimus directly to the medial layer of an artery via a liquid delivery catheter.
RESUMO
Acellular vascular scaffolds with capture molecules have shown great promise in recruiting circulating endothelial colony forming cells (ECFCs) to promote in vivo endothelialization. A microenvironment conducive to cell spreading and differentiation following initial cell capture are key to the eventual formation of a functional endothelium. In this study, syndecan-4 and stromal cell-derived factor-1 alpha were used to functionalize an elastomeric biomaterial composed of poly(glycerol sebacate), Silk Fibroin and Type I Collagen, termed PFC, to enhance ECFC-material interaction. Functionalized PFC (fPFC) showed significantly greater ECFCs capture capability under physiological flow. Individual cell spreading area on fPFC (1474 ± 63 µm2 ) was significantly greater than on PFC (1187 ± 54 µm2 ) as early as 2 h, indicating enhanced cell-material interaction. Moreover, fPFC significantly upregulated the expression of endothelial cell specific markers such as platelet endothelial cell adhesion molecule (24-fold) and Von Willebrand Factor (11-fold) compared with tissue culture plastic after 7 days, demonstrating differentiation of ECFCs into endothelial cells. fPFC fabricated as small diameter conduits and tested using a pulsatile blood flow bioreactor were stable and maintained function. The findings suggest that the new surface functionalization strategy proposed here results in an endovascular material with enhanced endothelialization.
Assuntos
Quimiocina CXCL12 , Células Endoteliais , Sindecana-4 , Diferenciação Celular , Células Cultivadas , Quimiocina CXCL12/metabolismo , Células Endoteliais/metabolismo , Neovascularização Fisiológica , Sindecana-4/metabolismoRESUMO
The local delivery of antiproliferative agents to inhibit neointimal growth is not specific to vascular smooth muscle cells (VSMC) and delays reendothelialization and vascular healing. This investigation was intended to evaluate the effect of luminal delivery of a VSMC-specific aptamer on endothelial healing. The impact of an RNA aptamer (Apt 14) was first examined on the migration and proliferation of primary cultured porcine aortic endothelial cells (ECs) in response to in vitro scratch wound injury. We further evaluated the impact of Apt 14 on reendothelialization when delivered locally in a swine iliofemoral injury model. Although Apt 14 did not affect EC migration and proliferation, in vitro results confirmed that paclitaxel significantly inhibited EC migration and proliferation. En face scanning electron microscopy demonstrated confluent endothelium with elongated EC morphology in Apt 14-treated arteries 14 and 28 days post-treatment. In contrast, vessels treated with paclitaxel-coated balloons displayed a cobblestone morphology and significant platelet and fibrin attachment at cell junctions. These results provide the first evidence of the efficacy of a cell-targeted RNA aptamer to facilitate endothelial healing in a clinically relevant large animal model.
RESUMO
The ability of endothelial cells to sense and respond to dynamic changes in blood flow is critical for vascular homeostasis and cardiovascular health. The mechanical and geometric properties of the nuclear and cytoplasmic compartments affect mechanotransduction. We hypothesized that alterations to these parameters have resulting mechanosensory consequences. Using atomic force microscopy and mathematical modeling, we assessed how the nuclear and cytoplasmic compartment stiffnesses modulate shear stress transfer to the nucleus within aging endothelial cells. Our computational studies revealed that the critical parameter controlling shear transfer is not the individual mechanics of these compartments, but the stiffness ratio between them. Replicatively aged cells had a reduced stiffness ratio, attenuating shear transfer, while the ratio was not altered in a genetic model of accelerated aging. We provide a theoretical framework suggesting that dysregulation of the shear stress response can be uniquely imparted by relative mechanical changes in subcellular compartments.
RESUMO
OBJECTIVE: Tissue-engineered blood vessels (TEBV) have been proposed as an alternative to prosthetic grafts for dialysis access. However, arteriovenous (AV) grafts must withstand extreme flow rates and frequent needle trauma. In a proof-of-concept study, we sought to determine whether scaffold-based TEBV could withstand the hemodynamic and mechanical challenges of chronic dialysis access. METHODS: TEBV were constructed using decellularized arterial scaffolds seeded with autologous ovine endothelial cells (EC) derived from circulating endothelial progenitor cells (EPC) using a novel high-affinity capture approach. Seeded scaffolds were preconditioned to arterial pressure and flow in a bioreactor for 2 weeks prior to implantation to create carotid artery to jugular vein AV grafts in each animal. TEBV were healed for 1 month before initiating percutaneous needle puncture 3 days/week. TEBV wall geometry and patency were monitored using duplex imaging and were either explanted for histologic analysis at 2 months (n = 5) or followed for up to 6 months until venous outflow stenosis threatened AV graft patency (n = 6). RESULTS: Despite high flow, TEBV maintained stable geometry with only modest wall dilation (under 6%) by 4 months after implantation. Needle access was well tolerated with a single puncture site complication, a small pseudoaneurysm, occurring in the late group. Time-to-hemostasis at puncture sites averaged 4 ± 2 minutes. Histologic analysis at 2 months demonstrated repopulation of the outer TEBV wall by host cells and healing of needle punctures by cellular ingrowth and new matrix deposition along the tract. TEBV followed beyond 2 months showed stable wall geometry but, consistent with the primary mode of clinical AV graft failure, all TEBV eventually developed venous anastomotic stenosis (mean, 4.4 ± 0.9 months; range, 3.3-5.6 months postimplantation; n = 6). CONCLUSIONS: This pilot study supports the concept of creating dialysis access from scaffold-based autologous TEBV. Engineered AV grafts were created within a clinically relevant time frame and demonstrated stable wall geometry despite high flow and repeated puncture. Cellular ingrowth and puncture site healing may improve wall durability, but venous outflow stenosis remains the primary mode of TEBV graft failure in the ovine model.
Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Artérias Carótidas/cirurgia , Células Endoteliais/transplante , Hemodinâmica , Veias Jugulares/cirurgia , Diálise Renal , Engenharia Tecidual , Angiografia Digital , Animais , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Reatores Biológicos , Pressão Sanguínea , Implante de Prótese Vascular/efeitos adversos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Artérias Carótidas/fisiopatologia , Técnicas de Cultura de Células , Células Cultivadas , Constrição Patológica , Análise de Falha de Equipamento , Estudos de Viabilidade , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/patologia , Veias Jugulares/fisiopatologia , Teste de Materiais , Modelos Animais , Agulhas , Projetos Piloto , Desenho de Prótese , Falha de Prótese , Fluxo Pulsátil , Punções , Fluxo Sanguíneo Regional , Ovinos , Transplante de Células-Tronco , Estresse Mecânico , Fatores de Tempo , Engenharia Tecidual/métodos , Alicerces Teciduais , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler em Cores , Ultrassonografia Doppler de Pulso , Grau de Desobstrução VascularRESUMO
OBJECTIVE: The purpose of this study was to determine the impact of varying inflation parameters on paclitaxel delivery and retention using a commercially available DCB. BACKGROUND: Drug-coated balloons (DCB) have become the standard treatment for peripheral artery disease. Clinical data suggest that varying DCB delivery parameters directly impact patient outcome. Differences in delivery parameters can potentially alter the retention of the drug coating on DCBs. METHODS: Harvested porcine carotid arteries were utilized in an ex vivo pulsatile flow bioreactor system. The DCBs were then deployed at a DCB-to-artery ratio of 1:1 or 1.25:1, an inflation time of 30 seconds or 1 minute and transit time of 30 seconds or 3 minutes. The amount of drug retention in arterial tissue was evaluated by pharmacokinetic analysis at 1 hour and 1 day post DCB deployment. RESULTS: Arterial paclitaxel levels were found to be less at an inflation ratio of 1:1 with 3-minute transit time as compared to 30 seconds of transit time at 1 hour (12.3 ± 1.6 ng/mg vs. 391 ± 139 ng/mg, P = .036). At 1-day, DCBs deployed at a ratio of 1:1 resulted in less drug retention as compared to 1.25:1 (61.3 ± 23.1 ng/mg vs. 404 ± 195 ng/mg, P = .013). CONCLUSION: Arterial paclitaxel retention is reduced with extended transit times and sub-optimal expansion of the balloon. Optimization of delivery parameters can serve as an effective strategy to enhance clinical DCB outcomes.
Assuntos
Angioplastia com Balão , Fármacos Cardiovasculares , Doença Arterial Periférica , Animais , Fármacos Cardiovasculares/farmacocinética , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel , Doença Arterial Periférica/terapia , Preparações Farmacêuticas , Suínos , Resultado do TratamentoRESUMO
Anti-proliferative agents have been the primary therapeutic drug of choice to inhibit restenosis after endovascular treatment. However, recent safety and efficacy concerns for patients who underwent peripheral artery disease revascularization have demonstrated the need for alternative therapeutics. The aim of this investigation was to investigate the efficacy of a cell-specific RNA aptamer inhibiting vascular smooth muscle cell proliferation and migration. First, the impact of the RNA aptamer (Apt 14) on the wound healing of primary cultured porcine vascular smooth muscle cells (VSMCs) was examined in response to a scratch wound injury. We then evaluated the effect of local luminal delivery of Apt 14 on neointimal formation in a clinically relevant swine iliofemoral injury model. In contrast with a non-selected control aptamer (NSC) that had no impact on VSMC migration, Apt 14 attenuated the wound healing of primary cultured porcine VSMCs to platelet-derived growth factor-BB. Histological analysis of the Apt 14-treated arteries demonstrated a significant reduction in neointimal area percent diameter stenosis compared with arteries treated with saline and NSC controls. The findings of this study suggest that aptamers can function as selective inhibitors and thus provide more fine-tuning to inhibit selective pathways responsible for neointimal hyperplasia.
RESUMO
Coronary bifurcations represent specific regions of the arterial tree that are susceptible to atherosclerotic lesions. While the effects of vessel compliance, curvature, pulsatile blood flow, and cardiac motion on coronary endothelial shear stress have been widely explored, the effects of myocardial contraction on arterial wall stress/strain (WS/S) and vessel stiffness distributions remain unclear. Local increase of vessel stiffness resulting from wall-strain stiffening phenomenon (a local process due to the nonlinear mechanical properties of the arterial wall) may be critical in the development of atherosclerotic lesions. Therefore, the aim of this study was to quantify WS/S and stiffness in coronary bifurcations and to investigate correlations with plaque sites. Anatomic coronary geometry and cardiac motion were generated based on both computed tomography and MRI examinations of eight patients with minimal coronary disease. Computational structural analyses using the finite element method were subsequently performed, and spatial luminal arterial wall stretch (LW(Stretch)) and stiffness (LW(Stiff)) distributions in the left main coronary bifurcations were calculated. Our results show that all plaque sites were concomitantly subject to high LW(Stretch) and high LW(Stiff), with mean amplitudes of 34.7 ± 1.6% and 442.4 ± 113.0 kPa, respectively. The mean LW(Stiff) amplitude was found slightly greater at the plaque sites on the left main coronary artery (mean value: 482.2 ± 88.1 kPa) compared with those computed on the left anterior descending and left circumflex coronary arteries (416.3 ± 61.5 and 428.7 ± 181.8 kPa, respectively). These findings suggest that local wall stiffness plays a role in the initiation of atherosclerotic lesions.
Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/patologia , Imageamento por Ressonância Magnética , Contração Miocárdica , Placa Aterosclerótica/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Fenômenos Biomecânicos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Elasticidade , Feminino , Análise de Elementos Finitos , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Dinâmica não Linear , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Placa Aterosclerótica/fisiopatologia , Valor Preditivo dos Testes , Estresse Mecânico , Fatores de TempoRESUMO
OBJECTIVES: There is significant room for improvement in the development of tissue-engineered blood vessels (TEBVs) for vascular reconstruction. Most commonly, TEBVs are seeded with endothelial cells (ECs) only. This provides an antithrombogenic surface but suboptimal physiologic characteristics compared with native arteries, due to lack of smooth muscle cells (SMCs) in the vessel media. Although SMCs are critical in vessel architecture and function throughout the vascular tree, few studies have incorporated SMCs in TEBVs implanted in vivo. As such, the goal of the present study was to evaluate the effect of SMC coseeding with ECs on TEBV maturation, structure, and function after prolonged in vivo maturation. METHODS: Dual-seeded TEBVs (dsTEBVs) were created by coseeding autologous ECs derived from circulating progenitor cells and SMCs from artery explants onto the lumen and outer surface of extracellular matrix scaffolds, respectively. Control vessels were seeded with ECs alone (ecTEBV). All vessels were preconditioned to pulsatile flow for 10 to 14 days in a bioreactor, implanted as arterial interposition grafts in sheep, and allowed to heal and adapt in vivo for 4 months before ex vivo physiologic testing and histologic analysis. RESULTS: All implants were patent at 4 months. There were no structural failures, aneurysms, or infectious complications. The dsTEBVs exhibited a greater degree of wall maturation, characterized by higher medial cellularity (P = .01) and greater percentage of α-actin (P = .005) and SMC-specific muscle myosin heavy chain (P = .005) staining compared with ecTEBVs. Contractile responses to phenylephrine and serotonin were significantly greater in isolated rings of dsTEBVs than those observed in ecTEBVs (P = .01). CONCLUSIONS: To our knowledge, this is the first study that demonstrates enhanced in vivo wall maturation and contractile function of TEBVs coseeded with autologous SMCs and ECs compared with EC seeding alone. These data suggest a coseeding strategy can be accomplished in a clinically relevant timeframe (typically 6 weeks) and may provide advantages for arterial reconstruction compared with vessels engineered only with endothelium.
Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Músculo Liso Vascular/transplante , Miócitos de Músculo Liso/transplante , Engenharia Tecidual , Actinas/metabolismo , Animais , Reatores Biológicos , Artéria Carótida Primitiva/cirurgia , Células Cultivadas , Técnicas de Cocultura , Células Endoteliais/transplante , Feminino , Artéria Femoral/cirurgia , Músculo Liso Vascular/efeitos dos fármacos , Músculo Liso Vascular/metabolismo , Miócitos de Músculo Liso/efeitos dos fármacos , Miócitos de Músculo Liso/metabolismo , Cadeias Pesadas de Miosina/metabolismo , Desenho de Prótese , Fluxo Pulsátil , Ovinos , Fatores de Tempo , Alicerces Teciduais , Transplante Homólogo , Grau de Desobstrução Vascular , Vasoconstrição/efeitos dos fármacos , Vasoconstritores/farmacologiaRESUMO
Purpose: The goal of this study was to develop an ex vivo system capable of rapidly evaluating arterial drug levels in living, isolated porcine carotid arteries. Methods: A vascular bioreactor system was developed that housed a native porcine carotid artery under physiological flow conditions. The ex vivo bioreactor system was designed to quantify the acute drug transfer of catheter-based drug delivery devices into explanted carotid arteries. To evaluate our ex vivo system, a paclitaxel-coated balloon and a perfusion catheter device delivering liquid paclitaxel were utilized. At 1-h post-drug delivery, arteries were removed, and paclitaxel drug levels measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Parallel experiments were performed in a pig model to validate ex vivo measurements. Results: LC-MS/MS analysis demonstrated arterial paclitaxel levels of the drug-coated balloon-treated arteries to be 48.49 ± 24.09 ng/mg and the perfusion catheter-treated arteries to be 25.42 ± 9.74 ng/mg at 1 h in the ex vivo system. Similar results were measured in vivo, as arterial paclitaxel concentrations were measured at 59.23 ± 41.27 ng/mg for the drug-coated balloon-treated arteries and 23.43 ± 20.23 ng/mg for the perfusion catheter-treated arteries. Overall, no significant differences were observed between paclitaxel measurements of arteries treated ex vivo vs. in vivo. Conclusion: This system represents the first validated ex vivo pulsatile system to determine pharmacokinetics in a native blood vessel. This work provides proof-of-concept of a quick, inexpensive, preclinical tool to study acute drug tissue concentration kinetics of drug-releasing interventional vascular devices.
RESUMO
Perfusion catheters have recently emerged as a novel approach to deliver liquid anti-proliferative agents into flow obstructed arterial segments. The purpose of this study was to determine the impact of luminal delivery pressure on liquid drug penetration into the vessel wall. An ex vivo model using harvested porcine carotid arteries and a two-dimensional computational model were utilized to determine the impact of delivery pressure of liquid therapy into the arterial wall. A pig peripheral injury model determined the impact of intra-luminal delivery pressure on drug retention. Ex vivo results demonstrated that depth of fluid penetration varies from 6.93 ± 1.90% at 0 atm to 27.75 ± 6.61% penetration of the medial layer at 0.4 atm. Computational results had similar outcomes, as penetration varied between 4.4% and 22.84%. The in vivo results demonstrated significant increase in drug delivery to the arterial tissue at 0.4 atm versus 0.1 atm at 1 h (23.43 ± 13.59 ng/mg vs. 2.49 ± 1.81 ng/mg, p = 0.026) and 7 days (0.50 ± 0.39 ng/mg vs. 0.018 ± 0.023 ng/mg, p = 0.0496). The result of this study provides an innovative strategic and technical approach to enable targeted liquid therapy.
Assuntos
Artérias Carótidas/metabolismo , Doença Arterial Periférica/terapia , Animais , Sistemas de Liberação de Medicamentos , SuínosRESUMO
BACKGROUND: A strategy in minimizing thrombotic events of vascular constructs is to seed the luminal surface with autologous endothelial cells (ECs). The task of seeding ECs can be achieved via bioreactors, which induce mechanical forces (shear stress, strain, pressure) onto the ECs. Although bioreactors can achieve a confluent layer of ECs in vitro, their acute response to blood remains unclear. Moreover, the necessary mechanical conditions that will increase EC adhesion and function remain unclear. We hypothesize that preconditioning seeded endothelium under physiological flow will enhance their retention and function. OBJECTIVE: To determine the role of varying preconditioning protocols on seeded ECs in vitro and in vivo. METHODS: Scaffolds derived from decelluarized arteries seeded with autologous ECs were preconditioned for 9 days. Three specific protocols, low steady shear stress (SS), high SS, and cyclic SS were investigated. After preconditioning, the seeded grafts were exposed to 15 minutes of blood via an ex vivo arteriovenous shunt model or alternately an in vivo arteriovenous bypass graft model. RESULTS: The shunt model demonstrated ECs remained intact for all conditions. In the arteriovenous bypass model, only the cyclic preconditioned grafts remained intact, maintained morphology, and resisted the attachment of circulating blood elements such as platelets, red blood cells, and leukocytes. Western blotting analysis demonstrated an increase in the protein expression of eNOS and prostaglandin I synthase for the cyclic high shear stress-conditioned cells relative to cells conditioned with high shear stress alone. CONCLUSION: Cyclic preconditioning has been shown here to increase the ECs ability to resist blood flow-induced shear stress and the attachment of circulating blood elements, key attributes in minimizing thrombotic events. These studies may ultimately establish protocols for the formation of a more durable endothelial monolayer that may be useful in the context of small vessel arterial reconstruction.
Assuntos
Prótese Vascular , Artérias Carótidas/citologia , Células Endoteliais/fisiologia , Células-Tronco/fisiologia , Engenharia Tecidual , Alicerces Teciduais , Animais , Derivação Arteriovenosa Cirúrgica , Reatores Biológicos , Implante de Prótese Vascular , Western Blotting , Artérias Carótidas/transplante , Artérias Carótidas/ultraestrutura , Adesão Celular , Técnicas de Cultura de Células , Proliferação de Células , Células Cultivadas , Sistema Enzimático do Citocromo P-450/metabolismo , Células Endoteliais/metabolismo , Células Endoteliais/transplante , Células Endoteliais/ultraestrutura , Feminino , Oxirredutases Intramoleculares/metabolismo , Veias Jugulares/cirurgia , Óxido Nítrico Sintase Tipo III/metabolismo , Desenho de Prótese , Fluxo Pulsátil , Ovinos , Transplante de Células-Tronco , Células-Tronco/metabolismo , Células-Tronco/ultraestrutura , Estresse Mecânico , Suínos , Fatores de Tempo , Engenharia Tecidual/instrumentação , Engenharia Tecidual/métodosRESUMO
OPINION STATEMENT: Vulnerable carotid plaques at risk for rupture/ulceration do not always correlate with the severity of stenosis at bifurcation sites. Therefore, information on plaque morphology and composition is essential for identifying patients at high risk for acute major cerebrovascular events. Traditional imaging modalities, including angiography and ultrasound, are slowly being replaced by CT imaging, as this technology is readily available in most hospitals and provides high-resolution capabilities at relatively low cost. Improvements in MRI, particularly high-resolution gadolinium-enhanced MRI, currently make this modality the most informative technology, as it allows easy identification of lesion morphometry, calcification, and hemorrhage. Further, multimodal imaging of carotid artery plaques using fluorodeoxyglucose positron emission tomography/CT is slowly growing out of its infancy and is providing valuable information on the inflammatory component of the plaque, a critical indicator of lesion instability. These recent advancements in imaging technologies will no doubt dictate early treatment options for symptomatic and asymptomatic patients with noncritical carotid stenosis in the near future. Ultimately, however, the identification of important molecular surrogates in early lesion progression may eventually predict late-term risk and likely will provide the ideal strategy for reducing the morbidity and mortality of stroke.
RESUMO
The purpose of this pilot study was to investigate the feasibility of a perfusion catheter to deliver liquid paclitaxel into arterial segments. A clinically relevant rabbit ilio-femoral injury model was utilized to determine the impact of liquid paclitaxel delivered locally into the vessel wall using a perfusion catheter at 1 h to 14 days. Treatment by two clinically available forms of liquid paclitaxel, a solvent-based (sb) versus an albumin-bound (nab), along with a control (uncoated balloons), were investigated. Pharmacokinetic results demonstrated an increase in the retention of the sb-paclitaxel versus the nab-paclitaxel at 1 h; however, no other differences were observed at days one, three, and seven. Histological findings at 14 days showed significantly less neointimal area in the sb-paclitaxel treated arteries as compared with the nab-paclitaxel and the uncoated balloon-treated arteries. Additionally, percent area stenosis was significantly less in the sb-paclitaxel group. These results support the concept of local liquid delivery of paclitaxel into the arterial segments.