RESUMO
OBJECTIVE: This study aims to evaluate the effectiveness of individualized hemodialysis for unconventional hypotension in diabetic nephropathy patients. METHODS: A total of 60 patients were selected and randomly divided into study group and control group. The control group used the standard dialysis model, while the study group used the individualized hemodialysis scheme, in which the dialysis was performed using an individualized dialysis machine temperature control, pattern of natrium, and pattern of step ultrafiltration in combination with dialysate-containing glucose. RESULTS: The total occurrence rate of hypotension, dry weight standard-reaching rate, and blood quality during and after dialysis in the study group were superior to those in the control group (P < 0.05). Furthermore, the symptom scores in the study group (dizziness score, chest distress score, sweating score, muscle spasm score, gastrointestinal symptom score, and temporary mind change score) were lower than those in the control group (P < 0.05). The serum sodium, potassium, and chloride concentration in these two groups after dialysis was not statistically different (P > 0.05). CONCLUSION: The combined application of low temperature, pattern of natrium, pattern of step ultrafiltration, and dialysate-containing glucose individualization is safe and effective for preventing and controlling the occurrence of intradialytic hypotension (IDH), improve symptoms, and improve the dry weight standard-reaching rate.
Assuntos
Nefropatias Diabéticas/terapia , Hipotensão/prevenção & controle , Diálise Renal/métodos , Idoso , Nefropatias Diabéticas/complicações , Soluções para Diálise/farmacologia , Feminino , Humanos , Hipotensão/etiologia , Rins Artificiais , Masculino , Pessoa de Meia-Idade , Diálise Renal/efeitos adversos , Sódio/sangue , UltrafiltraçãoRESUMO
This study aims to investigate the efficacy and safety of neutral macroporous resin hemoperfusion in treating maintenance hemodialysis (MHD) patients with refractory uremic pruritus (RUP).Ninety patients were enrolled and were randomly divided into 3 groups: control group, experiment 1 group, and experiment 2 group. Clinical symptom scores of skin itching were recorded before and at 4 and 8 weeks after the treatment. In addition, serum parathyroid hormone (PTH), calcium (Ca), phosphorus (P), and C-reactive protein (CRP) were detected; and the calcium-phosphorus product ([Ca]â×â[P]) was calculated to compare the curative effect.VSA score, modified Duo pruritus score, and CRP: these indices decreased to some extent at 4 and 8 weeks after treatment in the 2 experiment groups, compared with pretreatment (Pâ<â0.05); and differences among these 3 groups were statistically significant (Pâ<â0.05). PTH, P, and [Ca]â×â[P]: these indices decreased to some extent at 4 and 8 weeks after treatment in the 2 experiment groups, compared with pretreatment (Pâ<â0.05); and differences between the control and experiment 1 groups, as well as between the control and experiment 2 groups, were statistically significant (Pâ<â0.05). However, the difference between the experiment 1 and experiment 2 groups were not statistically significant (Pâ<â0.05).The effects of HA330 and HA130 resin hemoperfusion apparatus on secondary hyperparathyroidism and the disorder of calcium and phosphorus metabolism are similar. The mechanism may be related to its strong adsorption effect, and its capacity to widely remove inflammatory mediators, immune mediators, and endotoxins.
Assuntos
Hemoperfusão/métodos , Prurido/etiologia , Prurido/terapia , Diálise Renal/efeitos adversos , Uremia/etiologia , Uremia/terapia , Adulto , Idoso , Proteína C-Reativa , Cálcio/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hormônio Paratireóideo/sangue , Fósforo/sangueRESUMO
An UPLC-MS/MS method for determination of ten steroid hormones in animal origin food has been developed with pretreatment of the samples by matrix solid-phase dispersion (MSPD). The MSPD conditions, including the dispersing sorbents, elution solvents, ratio of sorbent to sample and the volume of the elution solvent have been investigated and optimised, and the method has been evaluated and validated. The results showed that the developed method has satisfactory linearity between the MS/MS responses of the analytes and the concentration of the steroid hormones, and the limits of the detection can reach 0.01µg/kg for most of the analytes. The spiking recoveries of the steroid hormones in chicken, pork, beef and sausage samples were between 76.8% and 98.7% with RSDs lower than 10%. The results demonstrated that the developed approach has high sensitivity and repeatability, and can rapidly determinate the trace residues of steroid hormones in complex food matrices.
Assuntos
Contaminação de Alimentos/análise , Produtos da Carne/análise , Extração em Fase Sólida/métodos , Esteroides/química , Esteroides/isolamento & purificação , Espectrometria de Massas em Tandem/métodos , Animais , Bovinos , Galinhas , Espectrometria de Massas por Ionização por Electrospray/métodos , SuínosRESUMO
Surface molecular imprinted polymers (MIPs) on silica gel particles for highly selective recognition of tetrabromobisphenol A (TBBPA) were prepared by a sol-gel process. Diphenolic Acid (DPA) and bisphenol A (BPA), whose structures were similar to that of TBBPA were selected as dummy template molecules, and 3-aminopropyltriethoxysilane (APTES) and tetramethoxysilane (TEOS) were chosen as functional monomer and cross-linker, respectively. The obtained materials were characterized by FT-IR with diffuse reflectance accessory and the results indicated polymers were successfully grafted on the surface of silica gel supporters. The maximum static adsorption capacities for TBBPA of the DPA-MIPs, BPA-MIPs and non-imprinted polymers (NIPs) were 45, 38 and 22 mg g(-1) respectively, and the results of dynamic adsorption showed that the adsorption equilibrium can be achieved within 15 min for DPA- and BPA-MIPs. Both the DPA- and BPA-MIPs have higher selectivity for TBBPA than that of NIP when they are used as the sorbents for the solid phase extraction (SPE), while the adsorption property of DPA-MIPs was superior to that of BPA-MIPs at low concentration levels of TBBPA. The results indicated DPA-MIPs had more high affinity binding sites for TBBPA, which demonstrated that the strong interactions between the template and the functional monomer were favorable to form high affinity binding sites and improve the selectivity of the polymers. A corresponding analytical method for determination of the TBBPA residues in environmental samples was developed. The recoveries of TBBPA in tap water, river water and lake water were in the range from 85% to 97% with relative standard deviations below 7%, and its limit of detection can reach 2 ng mL(-1).
Assuntos
Impressão Molecular/métodos , Bifenil Polibromatos/isolamento & purificação , Dióxido de Silício/química , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/isolamento & purificação , Água/química , Adsorção , Cromatografia Líquida , Água Doce/química , Fenóis/química , Bifenil Polibromatos/análise , Bifenil Polibromatos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/químicaRESUMO
Molecularly imprinted film with diphenolic acid (DPA) as dummy template molecule has been grafted on the surface of Mn-doped ZnS quantum dots (QDs) to develop a selective and sensitive sensor for rapid determination of tetrabromobisphenol A (TBBPA) in water and soils. The obtained DPA-MIP-QDs sensor has distinguished selectivity and high binding affinity to TBBPA. The fluorescence quenching fractions of the sensor presented a satisfactory linearity with the concentrations of TBBPA in the range of 0.1-100 µM, and its limit of detection can reach 0.015 µM. The sensor has been successfully applied to determine the TBBPA in water and soil samples, and the average recoveries of the TBBPA at various spiking levels ranged from 80.2% to 96.5% with relative standard deviation below 8.0%. The results provided a clue to develop sensors for rapid determination of hazardous materials from complex matrixes.