Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
1.
Heart Lung Circ ; 32(2): 252-260, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36443175

RESUMO

BACKGROUND: Most modern cardiac implantable electronic device (CIED) systems are now compatible with magnetic resonance imaging (MRI) scans. The requirement for both pre- and post-MRI CIED checks imposes significant workload to the cardiac electrophysiology service. Here, we sought to determine the burden of CIED checks associated with MRI scans. METHODS: We identified all CIED checks performed peri-MRI scans at our institution over a 3-year period between 1 July 2017 to 30 June 2020, comprising three separate financial years (FY). Device check reports, MRI scan reports and clinical summaries were collated. The workload burden was determined by assessing the occasions and duration of service. Analysis was performed to determine cost burden/projections for this service and identify factors contributing to the workload. RESULTS: A total of 739 CIED checks were performed in the peri-MRI scan setting (370 pre- and 369 post-MRI scan), including 5% (n=39) that were performed outside of routine hours (weekday <8 am or >5 pm, and weekends). MRIs were performed for 295 patients (75±13 years old, 64% male) with a CIED (88% permanent pacemaker, and 12% high voltage device), including 49 who had more than one MRI scan. The proportion of total MRI scans for patients with a CIED in-situ increased each FY (from 0.5% of all MRIs in FY1, to 0.9% in FY2, to 1.0% in FY3). The weekly workload increased (R2=0.2, p<0.001), but with week-to-week variability due to ad hoc scheduling (209 days with only one MRI vs 78 days with ≥2 MRIs for CIED patients). The projected annual cost of this service will increase to AUD$161,695 in 10 years for an estimated annual 546 MRI scans for CIED patients. CONCLUSIONS: There is an increasing workload burden and expense associated with CIED checks in the peri-MRI setting. Appropriate budgeting, staff allocation and standardisation of automated CIED pre-programming features among manufacturers are urgently needed.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Imageamento por Ressonância Magnética/métodos
2.
J Cardiovasc Electrophysiol ; 33(6): 1300-1311, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35441755

RESUMO

AIMS: The objective of the study was to conduct a systematic review to describe and compare the different approaches for performing cardiac electrophysiology (EP) procedures in patients with interrupted inferior vena cava (IVC) or equivalent entities causing IVC obstruction. METHODS: We conducted a structured search to identify manuscripts reporting EP procedures with interrupted IVC or IVC obstruction of any aetiology published up until August 2020. No restrictions were applied in the search strategy. We also included seven local cases that met inclusion criteria. RESULTS: The analysis included 142 patients (mean age 48.9 years; 48% female) undergoing 143 procedures. Obstruction of the IVC was not known before the index procedure in 54% of patients. Congenital interruption of IVC was the most frequent cause (80%); and, associated congenital heart disease (CHD) was observed in 43% of patients in this setting. The superior approach for ablation was the most frequently used strategy (52%), followed by inferior approach via the azygos or hemiazygos vein (24%), transhepatic approach (14%), and retroaortic approach (10%). Electroanatomical mapping (58%), use of long sheaths (41%), intracardiac echocardiography (19%), transesophageal echocardiography (15%) and remote controlled magnetic navigation (13%) were used as adjuncts to aid performance. Ablation was successful in 135 of 140 procedures in which outcomes were reported. Major complications were only reported in patients undergoing AF ablation, including two patients with pericardial effusion, one of whom required surgical repair, and another patient who died after inadvertent entry into an undiagnosed atrioesophageal fistula from a previous procedure. CONCLUSION: The superior approach is most frequent approach for performing EP procedures in the setting of obstructed IVC. Transhepatic approach is a feasible alternative, and may provide a "familiar approach" for transseptal access when it is required. Adjunctive use of long sheaths, intravascular echocardiography, electro-anatomical mapping and remote magnetic navigation may be helpful, especially if there is associated complex CHD. With careful planning, EP procedures can usually be successfully performed with a low risk of complications.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Cardiopatias Congênitas , Malformações Vasculares , Veia Cava Inferior , Eletrofisiologia Cardíaca , Ecocardiografia , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veia Cava Inferior/anormalidades , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
3.
BMC Cardiovasc Disord ; 22(1): 439, 2022 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-36209063

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are small subcutaneously implanted devices that detect changes in R-wave amplitudes (RWAs), effective in arrhythmia-monitoring. Although ICMs have proven to be immensely successful, electrical artefacts are frequent and can lead to misdiagnosis. Thus, there is a growing need to sustain and increase efficacy in detection rates by gaining insight into various patient-specific factors such as body postures and activities. METHODS: RWAs were measured in 15 separate postures, including supine, lying on the right-side (RS) or left-side (LS) and sitting, and two separate ICM orientations, immediately after implantation of Confirm Rx™ ICM in 99 patients. RESULTS: The patients (53 females and 46 males, mean ages 66.62 ± 14.7 and 66.40 ± 12.25 years, respectively) had attenuated RWAs in RS, LS and sitting by ~ 26.4%, ~ 27.8% and ~ 21.2% respectively, compared to supine. Gender-based analysis indicated RWAs in RS (0.32 mV (0.09-1.03 mV), p < 0.0001) and LS (0.37 mV (0.11-1.03 mV), p = 0.004) to be significantly attenuated compared to supine (0.52 mV (0.20-1.03 mV) for female participants. Similar attenuation was not evident for male participants. Further, parasternally oriented ICMs (n = 44), attenuated RWAs in RS (0.37 mV(0.09-1.03 mV), p = 0.05) and LS (0.34 mV (0.11-1.03 mV), p = 0.02) compared to supine (0.48 mV (0.09-1.03 mV). Similar differences were not observed in participants with ICMs in the 45°-relative-to-sternum (n = 46) orientation. When assessing the combined effect of gender and ICM orientation, female participants demonstrated plausible attenuation in RWAs for RS and LS postures compared to supine, an effect not observed in male participants. CONCLUSION: This is the first known study depicting the effects on RWA due to body postures and activities immediately post-implantation with an overt impact by gender and orientation of ICM. Future work assessing the cause of gender-based differences in RWAs may be critical. TRIAL REGISTRATION: Clinical Trials, NCT03803969. Registered 15 January 2019 - Retrospectively registered, https://clinicaltrials.gov/NCT03803969.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura
4.
J Math Biol ; 85(1): 8, 2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35819503

RESUMO

We study the probability of fixation in a stochastic two-species competition model. By identifying a naturally occurring fast timescale, we derive an approximation to the associated backward Kolmogorov equation that allows us to obtain an explicit closed form solution for the probability of fixation of either species. We use our result to study fitness tradeoff strategies and show that, despite some tradeoffs having nearly negligible effects on the corresponding deterministic dynamics, they can have large implications for the outcome of the stochastic system.


Assuntos
Processos Estocásticos , Dinâmica Populacional , Probabilidade
5.
J Electrocardiol ; 73: 42-48, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35633601

RESUMO

BACKGROUND: Little data exists on electrogram sensing in current generation of miniaturized insertable cardiac monitors (ICMs). OBJECTIVE: To compare the sensing capability of ICM with different vector length: Medtronic Reveal LINQ (~40 mm) vs. Biotronik Biomonitor III (BM-III, ~70 mm). METHODS: De-identified remote monitoring transmissions from n = 40 patients with BM-III were compared with n = 80 gender and body mass index (BMI)-matched patients with Reveal LINQ. Digital measurement of P- and R-wave amplitude from calibrated ICM electrograms was undertaken by 3 investigators independently. Further, we evaluated the impact of BMI and gender on P-wave visibility. RESULTS: Patients in both groups were well matched for gender and BMI (53% male, mean BMI 26.7 kg/m2, both p = NS). Median P- and R-wave amplitude were 97% & 56% larger in the BM-III vs. LINQ [0.065 (IQR 0.039-0.10) vs. 0.033 (IQR 0.022-0.050) mV, p < .0001; & 0.78 (IQR 0.52-1.10) vs. 0.50 (IQR 0.41-0.89) mV, p = .012 respectively). The P/R-wave ratio was 36% greater with the BM-III (p < .001). The 25th percentile of P-wave amplitude for all 120 patients was .026 mV. Logistic regression analysis showed BM-III was more likely than LINQ to have P-wave amplitude ≥.026 mV (OR 7.47, 95%CI 1.965-29.42, p = .003), and increasing BMI was negatively associated with P-wave amplitude ≥.026 mV (OR 0.84, 95%CI 0.75-0.95, p = .004). However, gender was not significantly associated with P-wave amplitude ≥.026 mV (p = .37). CONCLUSION: The longer ICM sensing vector of BM-III yielded larger overall P- and R- wave amplitude than LINQ. Both longer sensing vector and lower BMI were independently associated with greater P-wave visibility.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Feminino , Humanos , Masculino
6.
Heart Lung Circ ; 31(8): 1054-1063, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35760743

RESUMO

Recognising the need for a national approach for the recommended best practice for the follow-up of implanted cardiac rhythm devices to ensure patient safety, this document has been produced by the Cardiac Society of Australia and New Zealand (CSANZ). It draws on accepted practice standards and guidelines of international electrophysiology bodies. It lays out methodology, frequency, and content of follow-up, including remote monitoring; personnel, including physician, allied health, nursing and industry; paediatric and adult congenital heart patients; and special considerations including magnetic resonance imaging scanning, perioperative management, and hazard alerts.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Adulto , Austrália , Criança , Eletrônica , Seguimentos , Humanos , Nova Zelândia
7.
Heart Lung Circ ; 31(8): 1119-1125, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35461785

RESUMO

BACKGROUND: Requests from the emergency department (ED) for cardiac implantable electronic device (CIED) checks constitute a large workload for cardiac electrophysiology services. We sought to determine the yield of, and clinical characteristics associated with, clinically relevant (remarkable) issues from ED CIED checks. METHODS: Consecutive CIED checks from our ED over a 12-month period were studied. A remarkable issue (RI) was defined as arrhythmia relating to the presentation or device/lead issue requiring reprogramming or intervention. The association between the presenting complaint and an RI was assessed using regression analysis. Multivariable regression model was used to identify pre-specified patient-level characteristics that were predictive of a RI. RESULTS: A RI was found in 28% (n=98) of 354 ED CIED checks for 306 patients (76±16 yrs, 59% male). Most patients had no RI (n=224, 73%). One third of checks occurred after-hours and these had a higher yield of RIs than those during routine clinic hours (35% vs 23%, p=0.018). Presenting with a perceived ICD shock was predictive of a RI (odds ratio [OR] 6.0, 95% CI=1.8-20.0). Syncope/presyncope was five-fold less likely to be predictive of a RI (OR 0.19, 95% CI=0.13-0.28) despite being the most common indication for CIED check (51%, n=180 checks). Only history of AF was predictive of RI while advancing age was predictive of not finding a RI. CONCLUSION: Almost three-quarters of ED CIED checks did not yield any RI. Patient-reported ICD shock and history of AF were predictive of RI, while syncope/presyncope was not. New models of care especially during after-hours, may help to reduce the burden on cardiac electrophysiology services and health care costs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Atenção à Saúde , Eletrônica , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino
8.
Anal Bioanal Chem ; 413(14): 3801-3811, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33961103

RESUMO

Salmonella is a prevalent pathogen causing serious morbidity and mortality worldwide. There are over 2600 serovars of Salmonella. Among them, Salmonella Enteritidis, Salmonella Typhimurium, and Salmonella Paratyphi were reported to be the most common foodborne pathogenic serovars in the EU and China. In order to provide a more efficient approach to detect and distinguish these serovars, a new analytical method was developed by combining surface-enhanced Raman spectroscopy (SERS) with multi-scale convolutional neural network (CNN). We prepared 34-nm gold nanoparticles (AuNPs) as the label-free Raman substrate, measured 1854 SERS spectra of these three Salmonella serovars, and then proposed a multi-scale CNN model with three parallel CNNs to achieve multi-dimensional extraction of SERS spectral features. We observed the impact of the number of iterations and training samples on the recognition accuracy by changing the ratio of the number of the training and testing sets. By comparing the calculated data with experimental one, it was shown that our model could reach recognition accuracy more than 97%. These results indicate that it was not only feasible to combine SERS spectroscopy with multi-scale CNN for Salmonella serotype identification, but also for other pathogen species and serovar identifications.


Assuntos
Infecções por Salmonella/microbiologia , Salmonella/química , Análise Espectral Raman/métodos , Ouro/química , Humanos , Nanopartículas Metálicas/química , Redes Neurais de Computação , Salmonella/classificação , Salmonella/isolamento & purificação , Fatores de Tempo
9.
Pacing Clin Electrophysiol ; 44(2): 266-273, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33433913

RESUMO

OBJECTIVE: To characterize contemporary pacemaker procedure trends. METHODS: Nationwide analysis of pacemaker procedures and costs between 2008 and 2017 in Australia. The main outcome measures were total, age- and gender-specific implant, replacement, and complication rates, and costs. RESULTS: Pacemaker implants increased from 12,153 to 17,862. Implantation rates rose from 55.3 to 72.6 per 100,000, a 2.8% annual increase (incidence rate ratio [IRR] 1.028; 95% CI, 1.02-1.04; p < .001). Pacemaker implants in the 80+ age group were 17.37-times higher than the < 50 group (95% CI 16.24-18.59; p < .001), and in males were 1.48-times higher than in females (95% CI 1.42-1.55; p < .001). However, there were similar increases according to age (p = .10) and gender (p = .68) over the study period. Left ventricular lead rates were stable (IRR 0.995; 95% CI 0.98-1.01; p = .53). Generator replacements decreased from 20.5 to 18.3 per 100,000 (IRR 0.975; 95% CI 0.97-0.98; p < .001). Although procedures for generator-related complications were stable (IRR 0.995; 95% CI 0.98-1.01; p = .54), those for lead-related complications decreased (IRR 0.985; 95% CI 0.98-0.99; p < .001). Rates for all pacemaker procedures were consistently greater in males (p < .001). Although annual costs of all pacemaker procedures increased from $178 million to $329 million, inflation-adjusted costs were more stable, rising from $294 million to $329 million. CONCLUSIONS: Increasing demand for pacemaker implants is driven by the ageing population and rising rates across all ages, while replacement and complication procedure rates appeared more stable. Males have consistently greater pacemaker procedure rates than females. Our findings have significant clinical and public health implications for healthcare resource planning.


Assuntos
Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Austrália , Custos e Análise de Custo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/economia , Marca-Passo Artificial/estatística & dados numéricos , Marca-Passo Artificial/tendências , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Utilização de Procedimentos e Técnicas/tendências , Estudos Retrospectivos , Fatores de Tempo
10.
J Theor Biol ; 486: 110104, 2020 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-31809716

RESUMO

Environmental variation can play an important role in ecological competition by influencing the relative advantage between competing species. Here, we consider such effects by extending a classical, competitive Moran model to incorporate an environment that fluctuates periodically in time. We adapt methods from work on these classical models to investigate the effects of the magnitude and frequency of environmental fluctuations on two important population statistics: the probability of fixation and the mean time to fixation. In particular, we find that for small frequencies, the system behaves similar to a system with a constant fitness difference between the two species, and for large frequencies, the system behaves similar to a neutrally competitive model. Most interestingly, the system exhibits nontrivial behavior for intermediate frequencies. We conclude by showing that our results agree quite well with recent theoretical work on competitive models with a stochastically changing environment, and discuss how the methods we develop ease the mathematical analysis required to study such models.


Assuntos
Probabilidade , Dinâmica Populacional
11.
Europace ; 22(2): 288-298, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31995177

RESUMO

AIMS: There is growing evidence that magnetic resonance imaging (MRI) scanning in patients with non-conditional cardiac implantable electronic devices (CIEDs) can be performed safely. Here, we aim to assess the safety of MRI in patients with non-conditional CIEDs. METHODS AND RESULTS: English scientific literature was searched using PubMed/Embase/CINAHL with keywords of 'magnetic resonance imaging', 'pacemaker', 'implantable defibrillator', and 'cardiac resynchronization therapy'. Studies assessing outcomes of adverse events or significant changes in CIED parameters after MRI scanning in patients with non-conditional CIEDs were included. References were excluded if the MRI conditionality of the CIEDs was undisclosed; number of patients enrolled was <10; or studies were case reports/series. About 35 cohort studies with a total of 5625 patients and 7196 MRI scans (0.5-3 T) in non-conditional CIEDs were included. The overall incidence of lead failure, electrical reset, arrhythmia, inappropriate pacing and symptoms related to pocket heating, or torque ranged between 0% and 1.43%. Increase in pacing lead threshold >0.5 V and impedance >50Ω was seen in 1.1% [95% confidence interval (CI) 0.7-1.8%] and 4.8% (95% CI 3.3-6.4%) respectively. The incidence of reduction in P- and R-wave sensing by >50% was 1.5% (95% CI 0.6-2.9%) and 0.4% (95% CI 0.06-1.1%), respectively. Battery voltage reduction of >0.04 V was reported in 2.2% (95% CI 0.2-6.1%). CONCLUSION: This meta-analysis affirms the safety of MR imaging in non-conditional CIEDs with no death or implantable cardioverter-defibrillator shocks and extremely low incidence of lead or device-related complications.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Arritmias Cardíacas/terapia , Coração , Humanos
12.
Pacing Clin Electrophysiol ; 42(7): 1038-1046, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31119745

RESUMO

INTRODUCTION: We conducted this study to show the safety and efficacy of a new implantable cardiac monitor (ICM), the BioMonitor 2 (Biotronik SE & Co. KG; Berlin, Germany), and to describe the arrhythmia detection performance. METHODS: The BioMonitor 2 has an extended sensing vector and is implanted close to the heart. It can transmit up to six subcutaneous electrocardiogram strips by Home Monitoring each day. We enrolled 92 patients with a standard device indication for an ICM in a single-arm, multicenter prospective trial. Patients were followed for 3 months, and 48-h Holter recordings were used to evaluate the arrhythmia detection performance. RESULTS: One patient withdrew consent and in one patient, the implantation failed. Two study device-related serious adverse events were reported, satisfying the primary safety hypothesis. Implantations took 7.4 ± 4.4 min from skin cut to suture. At 1 week, the R-wave amplitude was 0.75 ± 0.53 mV. In the 82 patients with completed Holter recordings, all patients with arrhythmias were correctly identified. False positive detections of arrhythmia were mostly irregular rhythms wrongly detected as atrial fibrillation (episode-based positive predictive value 72.5%). Daily Home Monitoring transmission was 94.9% successful. CONCLUSION: Safety and efficacy of the new device has been demonstrated. The detected R-wave amplitudes are large, leading to a low level of inappropriate detections due to over- or undersensing.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Theor Popul Biol ; 121: 12-25, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29627266

RESUMO

Through the lens of game theory, cooperation is frequently considered an unsustainable strategy: if an entire population is cooperating, each individual can increase its overall fitness by choosing not to cooperate, thereby still receiving all the benefit of its cooperating neighbors while no longer expending its own energy. Observable cooperation in naturally-occurring public goods games is consequently of great interest, as such systems offer insight into both the emergence and sustainability of cooperation. Here we consider a population that obeys a public goods game on a network of discrete regions (that we call colonies), between any two of which individuals are free to migrate. We construct a system of piecewise-smooth ordinary differential equations that couple the within-colony population dynamics and the between-colony migratory dynamics. Through a combination of analytical and numerical methods, we show that if the workers within the population migrate sufficiently fast relative to the cheaters, the network loses stability first through a Hopf bifurcation, then a torus bifurcation, after which one or more colonies collapse. Our results indicate that fast moving cheaters can act to stabilize worker-cheatercoexistence within network that would otherwise collapse. We end with a comparison of our results with the dynamics observed in colonies of the ant species Pristomyrmex punctatus, and argue that they qualitatively agree.


Assuntos
Migração Animal , Formigas , Comportamento Animal , Animais , Ecologia , Teoria dos Jogos , Abrigo para Animais , Modelos Biológicos , Dinâmica Populacional , Meio Social
14.
Europace ; 20(FI_3): f366-f376, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29267853

RESUMO

Aims: Several techniques have been utilized for the ablation of persistent (P) and long-standing persistent (LsP) atrial fibrillation (AF); however, the best approach of substrate ablation remains poorly defined. This study aims to examine the impact of ablation approach on outcomes associated with P or LsP AF ablation by conducting a meta-analysis and regression on contemporary literature. Methods and results: A systematic literature review was conducted up to 29 July 2015 for scientific literature reporting on outcomes associated with P or LsP AF ablation. One hundred and thirteen studies reported outcomes in a total of 18 657 patients undergoing various ablation approaches for the treatment of P-LsP AF between 2001 and 2015. The point efficacy estimate of a single-AF ablation procedure without the use of anti-arrhythmic drugs was 43% (95% CI; 39-47%). Multiple procedures and/or the use of anti-arrhythmic drugs increase success to 69% (95% CI; 66-71%). Meta-regression revealed that ablation technique (P < 0.001) and left atrial size (P = 0.02) were predictive of single procedure, drug-free success. The addition of extra-pulmonary substrate approaches was associated with declining efficacy when compared to a pulmonary vein ablation alone. Conclusion: The efficacy of a single-AF ablation procedure for P or LsP AF is 43%; however, can be increased to 69% with the use of multiple procedures and/or anti-arrhythmic drugs. Current literature supports the finding that pulmonary vein antrum ablation/isolation is at least equivalently efficacious to other contemporary P-LsP ablation strategies.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Fatores de Risco , Fatores de Tempo
15.
Artigo em Inglês | MEDLINE | ID: mdl-29477215

RESUMO

BACKGROUND: It has been suggested that ethnicity can make a significant difference to the likelihood of thromboembolic stroke related to atrial fibrillation. Ethnic differences have been shown to alter inflammatory and haemostatic factors; however, this may all be confounded by differences in cardiovascular risk factors between different ethnicity. The impact of different ethnicities on the thrombogenic profile is not known. The aim of this study was to investigate differences in markers of inflammation, endothelial function and tissue remodelling between Caucasian and Indian populations with supraventricular tachycardia (SVT). METHODS: Patients with structurally normal hearts undergoing catheter ablation for SVT were studied. This study included 23 Australian (Caucasian) patients from the Royal Adelaide Hospital, Adelaide, Australia and 24 Indian (Indian) patients from the Christian Medical College, Vellore, India. Blood samples were collected from the femoral vein, and right and left atria. Blood samples were analysed for the markers of endothelial function (ADMA, ET-1), inflammation (CD40L, VCAM-1, ICAM-1), and tissue remodelling (MMP-9, TIMP-1) using ELISA. RESULTS: The study populations were well matched for cardiovascular risk factors and the absence of structural heart disease. No difference in the echocardiographic measurements between the two ethnicities was found. In this context, there was no difference in markers of inflammation, endothelial function or tissue remodelling between the two SVT populations. CONCLUSION: Caucasian and Indian populations demonstrate similar inflammatory, endothelial function or tissue remodelling profiles. This study suggests a lack of an impact of different ethnicity in these populations in terms of thrombogenic risk.

17.
Appl Microbiol Biotechnol ; 101(13): 5365-5375, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28508923

RESUMO

In the fresh produce industry, validation of sanitation efficacy is critical to prevent cross-contamination of produce. The current validation approaches are either based on time-consuming plate counting assays or indirect measurements of chemical properties of wash water. In the study, the focus was to identify biomarkers that can provide direct assessment of oxidative damage in bacteria upon exposure to sanitizers in the presence of fresh produce and correlation of these oxidative biomarkers with logarithmic inactivation of bacteria. Two endogenous bacterial biomarkers, protein carbonylation and thiol oxidation, were evaluated for assessing oxidative damage in Escherichia coli O157:H7 and Listeria innocua during sanitation of pre-cut lettuce leaves with NaOCl or H2O2. Results show that NaOCl treatment was more effective than H2O2 for oxidation of both the intracellular thiols and protein carbonylation in the selected strains. Statistical analysis of the measurements illustrates that oxidation of the intracellular thiol induced by NaOCl or H2O2 was correlated with logarithmic reduction of E. coli O157:H7 and L. innocua. In contrast, changes in the protein carbonylation content were not correlated with reduction in bacterial cell viability. In summary, these results provide a novel approach to validate sanitation efficacy for the fresh produce industry.


Assuntos
Bactérias/metabolismo , Desinfecção , Microbiologia de Alimentos , Lactuca/microbiologia , Estresse Oxidativo , Bactérias/química , Bactérias/efeitos dos fármacos , Biomarcadores/análise , Desinfetantes/farmacologia , Escherichia coli/química , Escherichia coli/efeitos dos fármacos , Escherichia coli/metabolismo , Peróxido de Hidrogênio/farmacologia , Lactuca/efeitos dos fármacos , Listeria/química , Listeria/efeitos dos fármacos , Listeria/metabolismo , Oxidantes/farmacologia , Oxirredução , Carbonilação Proteica , Saneamento , Hipoclorito de Sódio/farmacologia , Compostos de Sulfidrila/análise , Compostos de Sulfidrila/metabolismo
18.
Compr Rev Food Sci Food Saf ; 16(3): 431-455, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-33371559

RESUMO

Cocoa is part of the cultural heritage in many areas of South and Central America and has played an important role in the history of human culture there. The modern methods of cocoa bean production for the purpose of the manufacture of modern chocolate are tied to the origin and development of cocoa bean fermentation and processing methods and the science of microbiology. To date, however, there has not been a study that discusses the impacts of both science and culture on the evolution of cocoa beans and cocoa bean processing. This work provides both a detailed overview of the evolution and historical development of cocoa, from its earliest forms to modern chocolate manufacturing, an in-depth discussion of the biochemistry of cocoa bean fermentation, as well as a compilation of primary research studies with details on fermentation methods, the scientific bases of interactions in microbial fermentations, and methods for their investigation, as well as metabolites that are produced. As a result, we present here the major microorganisms among all the ones that have been identified in previous studies. This database will aid researchers seeking standardized inoculants to drive cocoa bean fermentation, as well as serve as a guide for inventorying and assessing other food evolution-related studies regarding traditional and artisanal-based food systems.

19.
Cell Microbiol ; 17(5): 688-701, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25387594

RESUMO

Some of the world's most important diseases are caused by bacterial pathogens that deliver toxic effector proteins directly into eukaryotic cells using type III secretion systems. The myriad of pathological outcomes caused by these pathogens is determined, in part, by the manipulation of host cell physiology due to the specific activities of individual effectors among the unique suite each pathogen employs. YspI was found to be an effector, delivered by Yersinia enterocolitica Biovar 1B, that inhibits host cell motility. The action of YspI comes about through its specific interaction with focal adhesion kinase, FAK, which is a fulcrum of focal adhesion complexes for controlling cellular motility. The interaction was defined by a specific domain of YspI that bound to the FAK kinase domain. Further examination revealed that YspI-FAK interaction leads to a reduction of FAK steady-state levels without altering its phosphorylation state. This collection of observations and results showed YspI displays unique functionality by targeting the key regulator of focal adhesion complexes to inhibit cellular movement.


Assuntos
Proteínas de Bactérias/metabolismo , Sistemas de Secreção Bacterianos , Movimento Celular/efeitos dos fármacos , Células Epiteliais/fisiologia , Proteína-Tirosina Quinases de Adesão Focal/antagonistas & inibidores , Fatores de Virulência/metabolismo , Yersinia enterocolitica/fisiologia , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/enzimologia , Células Epiteliais/microbiologia , Células HeLa , Humanos , Ligação Proteica , Mapeamento de Interação de Proteínas , Yersinia enterocolitica/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA