Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 37(1): 8-15, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36357306

RESUMO

OBJECTIVES: Ischemic remodeling of the left ventricle in patients with coronary artery disease (CAD) results in geometric changes of the mitral valve (MV) apparatus, leading to reduced MV leaflet coaptation. Although the calculation of the coaptation area has value in assessing the effects of left ventricular remodeling on the MV, it is difficult and time-consuming to measure. In this study the authors hypothesized that the tenting volume (TV) would have a greater association with coaptation area than tenting height (TH) or tenting area (TA). DESIGN: A retrospective review. SETTING: A single tertiary-care academic hospital. PARTICIPANTS: There were 145 adult patients who underwent coronary artery bypass graft surgery between April 2018 and July 2020. MEASUREMENTS AND MAIN RESULTS: Intraoperative 2- and 3-dimensional transesophageal echocardiographic studies were obtained in the precardiopulmonary bypass period. Offline analysis was used to obtain TH, TA, TV and coaptation area for each patient. Correlation between the coaptation area and the TH, TA, and TV was conducted using Pearson's correlation. The median age of the population was 68.0 years (61.0-73.3), the body mass index was 29.0 kg/m2 (25.7-33.5), and 17.8% were females. Increases in TV were the most reliable predictor of decreases in coaptation area (R2 = 0.75) followed by TA (R2 = 0.48) and TH (R2 = 0.47). CONCLUSION: As a representative of the complete topography of the MV, the authors' study demonstrated that in patients with CAD, TV has a greater negative correlation with coaptation area as compared to TH or TA.


Assuntos
Doença da Artéria Coronariana , Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Adulto , Feminino , Humanos , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Remodelação Ventricular , Isquemia
2.
J Cardiothorac Vasc Anesth ; 37(7): 1088-1094, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37062664

RESUMO

The clinical utility of transesophageal echocardiography (TEE) is well-established for patients undergoing cardiac surgery. With the increase in percutaneous structural heart disease procedures that rely on TEE for procedural guidance, the use of TEE probes is expanding. Although there are well-established protocols for routine cleaning and decontaminating TEE probes between patient use, there is a lack of awareness and misconceptions about maintaining TEE probes' structural and electrical integrity. The electrical leakage test (ELT) is routinely performed between patient use. From a patient safety standpoint, the ELT is necessary to ensure the longevity of this expensive equipment and prevent disruptions to the workflow in a busy department caused by TEE probes being decommissioned due to probe damage. This technical communication aims to highlight the importance of maintaining TEE probes' structural and electrical integrity. The article also highlights and discusses probe handling techniques between patient use, emphasizing the ELT to ensure patient safety and compliance with national and international standards.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana , Humanos , Ecocardiografia Transesofagiana/métodos
3.
J Cardiothorac Vasc Anesth ; 37(11): 2194-2203, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37316432

RESUMO

Transcatheter edge-to-edge repair (TEER) of the mitral valve is a complex procedure requiring continuous image guidance with 2-dimensional and 3-dimensional transesophageal echocardiography. In this context, the role of the echocardiographer is of paramount importance. Training in interventional echocardiography for procedures such as TEER requires comprehending the complicated workflow of the hybrid operating room and advanced imaging skills that go beyond traditional echocardiography training to guide the procedure. Despite TEER being more commonly performed, the training structure for interventional echocardiographers is lagging, with many practitioners not having any formal training in image guidance for this procedure. In this context, novel training strategies must be developed to increase exposure and aid training. In this review, the authors present a step-wise approach to training for image guidance during TEER of the mitral valve. The authors have deconstructed this complex procedure into modular components and have incremental stages of training based on different steps of the procedure. At each step, trainees must demonstrate proficiency before advancing to the next step, thus ensuring a more structured approach to attaining proficiency in this complex procedure.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA