Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Front Robot AI ; 10: 1224492, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37323643

RESUMO

[This corrects the article DOI: 10.3389/frobt.2023.1123153.].

3.
Front Robot AI ; 10: 1123153, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37251354

RESUMO

A Healthcare-assistive Infection-control RObot (HIRO) is a healthcare-assistive robot that is deployed in an outpatient primary care clinic to sanitise the premises, monitor people in its proximity for their temperature and donning of masks, and usher them to service points. This study aimed to determine the acceptability, perceptions of safety, and concerns among the patients, visitors, and polyclinic healthcare workers (HCWs) regarding the HIRO. A cross-sectional questionnaire survey was conducted from March to April 2022 when the HIRO was at Tampines Polyclinic in eastern Singapore. A total of 170 multidisciplinary HCWs serve approximately 1,000 patients and visitors daily at this polyclinic. The sample size of 385 was computed using a proportion of 0.5, 5% precision, and 95% confidence interval. Research assistants administered an e-survey to gather demographic data and feedback from 300 patients/visitors and 85 HCWs on their perceptions of the HIRO using Likert scales. The participants watched a video on the HIRO's functionalities and were given the opportunity to directly interact with it. Descriptive statistics was performed and figures were presented in frequencies and percentages. The majority of the participants viewed the HIRO's functionalities favourably: sanitising (96.7%/91.2%); checking proper mask donning (97%/89.4%); temperature monitoring (97%/91.7%); ushering (91.7%/81.1%); perceived user friendliness (93%/88.3%), and improvement in the clinic experience (96%/94.2%). A minority of the participants perceived harm from the HIRO's liquid disinfectant (29.6%/31.5%) and that its voice-annotated instructions may be upsetting (14%/24.8%). Most of the participants accepted the HIRO's deployment at the polyclinic and perceived it to be safe. The HIRO used ultraviolet irradiation for sanitisation during after-clinic hours instead of disinfectants due to the perceived harm.

4.
JBR-BTR ; 81(3): 129-30, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10547261

RESUMO

Ultrasonographic and pathologic findings in a 26-year-old patient with a benign papilloma of the bladder are described. Ultrasound features include an irregular polypoid mass extending from the bladder wall.


Assuntos
Papiloma/diagnóstico por imagem , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Adulto , Cistoscopia , Seguimentos , Humanos , Masculino , Papiloma/patologia , Pólipos/diagnóstico por imagem , Pólipos/patologia , Ultrassonografia , Neoplasias da Bexiga Urinária/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA