Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Spinal Cord ; 62(1): 6-11, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37919382

RESUMO

STUDY DESIGN: Retrospective case-control study. OBJECTIVES: To investigate signal changes on T1w/T2w signal intensity ratio maps within cervical cord in patients with degenerative cervical myelopathy (DCM). SETTING: Novosibirsk Neurosurgery Center, Russia. METHODS: A total of 261 patients with DCM and 42 age- and sex-matched healthy controls were evaluated using the T1w/T2w mapping method and spinal cord automatic morphometry. The T1w/T2w signal intensity ratio, which reflects white matter integrity, and the spinal cord cross-sectional area (CSA) were calculated and compared between the patients and the controls. In patients with DCM, the correlations between these parameters and neurological scores were also evaluated. RESULTS: The regional T1w/T2w ratio values from the cervical spinal cord at the level of maximal compression in patients with DCM were significantly lower than those in healthy controls (p < 0.001), as were the regional CSA values (p < 0.001). There was a positive correlation between the regional values of the T1w/T2w ratio and the values of the CSA at the level of maximal spinal cord compression. CONCLUSIONS: T1w/T2w mapping revealed that spinal cord tissue damage exists at the level of maximal compression in patients with DCM in association with spinal cord atrophy according to automatic morphometry. These changes were correlated with each other.


Assuntos
Medula Cervical , Compressão da Medula Espinal , Doenças da Medula Espinal , Traumatismos da Medula Espinal , Humanos , Estudos de Casos e Controles , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Doenças da Medula Espinal/diagnóstico por imagem , Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/etiologia , Compressão da Medula Espinal/cirurgia , Medula Cervical/diagnóstico por imagem
2.
Sensors (Basel) ; 24(3)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38339508

RESUMO

The possibility of determining the elastic modules, viscosity coefficients, dielectric constant and electrical conductivity of a viscous conducting liquid using a piezoelectric resonator with a longitudinal electric field is shown. For the research, we chose a piezoelectric resonator made on an AT-cut quartz plate with round electrodes, operating with a shear acoustic mode at a frequency of about 4.4 MHz. The resonator was fixed to the bottom of a 30 mL liquid container. The samples of a mixture of glycerol and water with different viscosity and conductivity were used as test liquids. First, the frequency dependences of the real and imaginary parts of the electrical impedance of a free resonator were measured and, using the Mason electromechanical circuit, the elastic module, viscosity coefficient, piezoelectric constant and dielectric constant of the resonator material (quartz) were determined. Then, the container was filled with the test sample of a liquid mixture so that the resonator was completely covered with liquid, and the measurement of the frequency dependences of the real and imaginary parts of the electrical impedance of the loaded resonator was repeated. The dependences of the frequency of parallel and series resonances, as well as the maximum values of the electrical impedance and admittance on the conductivity of liquids for various viscosity values, were plotted. It was shown that these dependences can be used to unambiguously determine the viscosity and conductivity of the test liquid. Next, by fitting the theoretical frequency dependences of the real and imaginary parts of the electrical impedance of the resonator loaded with the liquid under study to the experimental dependences, the elastic module of the liquid and its dielectric constant were determined.

3.
Sensors (Basel) ; 23(2)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36679403

RESUMO

This study examines the effect of suspensions based on pure glycerol and diamond powder with different concentrations on the characteristics of resonators with a longitudinal electric field. We used two disk resonators made of the quartz and langasite plates with round electrodes on both sides of the plate and resonant frequencies of 4.4 and 4.1 MHz, operating in shear and longitudinal acoustic modes, respectively. Each resonator was mounted on the bottom of a 30 mL liquid container. During the experiments, the container was filled with the suspension under study in such a way that the resonator was completely immersed in the suspension, and the frequency dependences of the real and imaginary parts of the electrical impedance of the resonator were measured. As a result, the shear modulus of the elasticity and shear coefficient of the viscosity of the studied suspensions were determined. The material constants of the suspensions were found by fitting the theoretical frequency dependences of the real and imaginary parts of the electrical impedance of the resonator to the experimentally measured ones, which was calculated using Mason's equivalent circuit. As a result, the dependencies of the density, shear modulus of elasticity, shear viscosity coefficient, and velocity of the shear acoustic wave on the volume concentration of the diamond particles were constructed.


Assuntos
Glicerol , Som , Suspensões , Impedância Elétrica , Eletrodos
4.
Sensors (Basel) ; 23(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36850404

RESUMO

Currently, the lateral electric field excited resonators are used for the creation of various sensors. We have recently proposed a new type of acoustic resonator called radial electric field excited disk acoustic resonator. The advantage of this type of resonator is its high sensitivity to mechanical and electrical boundary conditions on its free surface. This makes it possible to determine both the acoustic and electrical properties of a thin layer of material deposited on the free end of the resonator. In this work, we used a radial electric field excited disk acoustic resonator of Russian-made barium plumbum zirconate titanate (BPZT) piezoceramics. With the help of this resonator, the material constants for the piezoceramic sample were refined, and their temperature dependencies were determined. Then, this resonator was used to determine the elastic modulus, viscosity, and conductivity of the chitosan acetate film in air and ammonia vapors of various concentrations. It was shown that the chitosan acetate film under the influence of ammonia vapor significantly changes its mechanical properties and increases its electrical conductivity thousands of times, and then completely restores its properties.

5.
Sensors (Basel) ; 23(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36679441

RESUMO

Backward acoustic waves are characterized by oppositely directed phase and group velocities. These waves can exist in isotropic and piezoelectric plates. They can be detected using a set of interdigital transducers with different spatial periods located on the same piezoelectric substrate. In this paper, the effect of a nonviscous and nonconductive liquid on the characteristics of a first-order backward antisymmetric wave in a YX plate of lithium niobate is studied theoretically and experimentally. It is shown that the presence of liquid does not lead to the transformation or disappearance of this wave. It is shown that these waves are close to the cutoff frequency and are characterized by the presence of a point with zero group velocity. The design of a liquid sensor based on these waves is proposed.


Assuntos
Acústica , Som , Transdutores
6.
Sensors (Basel) ; 23(14)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37514587

RESUMO

Antibiotics are widely used to treat infectious diseases. This leads to the presence of antibiotics and their metabolic products in the ecosystem, especially in aquatic environments. In many countries, the growth of pathogen resistance to antibiotics is considered a threat to national security. Therefore, methods for determining the sensitivity/resistance of bacteria to antimicrobial drugs are important. This review discusses the mechanisms of the formation of antibacterial resistance and the various methods and sensor systems available for analyzing antibiotic effects on bacteria. Particular attention is paid to acoustic biosensors with active immobilized layers and to sensors that analyze antibiotics directly in liquids. It is shown that sensors of the second type allow analysis to be done within a short period, which is important for timely treatment.


Assuntos
Antibacterianos , Técnicas Biossensoriais , Antibacterianos/farmacologia , Ecossistema , Bactérias , Farmacorresistência Bacteriana , Técnicas Biossensoriais/métodos
7.
Sensors (Basel) ; 22(8)2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35458922

RESUMO

In this study, a compact acoustic analyzer for express analysis of antibiotics based on a piezoelectric resonator with a lateral electric field and combined with a computer was developed. The possibility of determining chloramphenicol in aqueous solutions in the concentration range of 0.5-15 µg/mL was shown. Bacterial cells that are sensitive to this antibiotic were used as a sensory element. The change in the electrical impedance modulus of the resonator upon addition of the antibiotic to the cell suspension served as an analytical signal. The analysis time did not exceed 4 min. The correlation of the experimental results of an acoustic sensor with the results obtained using the light phase-contrast microscopy and standard microbiological analysis was established. The compact biological analyzer demonstrated stability, reproducibility, and repeatability of results.


Assuntos
Antibacterianos , Técnicas Biossensoriais , Acústica , Técnicas Biossensoriais/métodos , Impedância Elétrica , Reprodutibilidade dos Testes
8.
Int J Mol Sci ; 23(4)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35216301

RESUMO

Despite the fact that a range of vaccines against COVID-19 have already been created and are used for mass vaccination, the development of effective, safe, technological, and affordable vaccines continues. We have designed a vaccine that combines the recombinant protein and DNA vaccine approaches in a self-assembled particle. The receptor-binding domain (RBD) of the spike protein of SARS-CoV-2 was conjugated to polyglucin:spermidine and mixed with DNA vaccine (pVAXrbd), which led to the formation of particles of combined coronavirus vaccine (CCV-RBD) that contain the DNA vaccine inside and RBD protein on the surface. CCV-RBD particles were characterized with gel filtration, electron microscopy, and biolayer interferometry. To investigate the immunogenicity of the combined vaccine and its components, mice were immunized with the DNA vaccine pVAXrbd or RBD protein as well as CCV-RBD particles. The highest antigen-specific IgG and neutralizing activity were induced by CCV-RBD, and the level of antibodies induced by DNA or RBD alone was significantly lower. The cellular immune response was detected only in the case of DNA or CCV-RBD vaccination. These results demonstrate that a combination of DNA vaccine and RBD protein in one construct synergistically increases the humoral response to RBD protein in mice.


Assuntos
Vacinas contra COVID-19/química , Vacinas contra COVID-19/farmacologia , Imunidade Humoral/efeitos dos fármacos , Glicoproteína da Espícula de Coronavírus/química , Animais , Sítios de Ligação , Vacinas contra COVID-19/imunologia , Chlorocebus aethiops , Dextranos/química , Feminino , Células HEK293 , Humanos , Camundongos Endogâmicos BALB C , Domínios Proteicos , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Espermidina/química , Glicoproteína da Espícula de Coronavírus/genética , Glicoproteína da Espícula de Coronavírus/imunologia , Vacinas de DNA/genética , Vacinas de DNA/imunologia , Vacinas de DNA/farmacologia , Células Vero
9.
Sensors (Basel) ; 21(2)2021 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-33477254

RESUMO

A new type of piezoceramic acoustic resonator in the form of a circular disk with a radial exciting electric field is presented. The advantage of this type of resonator is the localization of the electrodes at one end of the disk, which leaves the second end free for the contact of the piezoelectric material with the surrounding medium. This makes it possible to use such a resonator as a sensor base for analyzing the properties of this medium. The problem of exciting such a resonator by an electric field of a given frequency is solved using a two-dimensional finite element method. The method for solving the inverse problem for determining the characteristics of a piezomaterial from the broadband frequency dependence of the electrical impedance of a single resonator is proposed. The acoustic and electric field inside the resonator is calculated, and it is shown that this location of electrodes makes it possible to excite radial, flexural, and thickness extensional modes of disk oscillations. The dependences of the frequencies of parallel and series resonances, the quality factor, and the electromechanical coupling coefficient on the size of the electrodes and the gap between them are calculated.

10.
Sensors (Basel) ; 21(5)2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33807879

RESUMO

A method for the rapid detection of coronaviruses is presented on the example of the transmissible gastroenteritis virus (TGEV) directly in aqueous solutions with different conductivity. An acoustic sensor based on a slot wave in an acoustic delay line was used for the research. The addition of anti-TGEV antibodies (Abs) diluted in an aqueous solution led to a change in the depth and frequency of resonant peaks on the frequency dependence of the insertion loss of the sensor. The difference in the output parameters of the sensor before and after the biological interaction of the TGE virus in solutions with the specific antibodies allows drawing a conclusion about the presence/absence of the studied viruses in the analyzed solution. The possibility for virus detection in aqueous solutions with the conductivity of 1.9-900 µs/cm, as well as in the presence of the foreign viral particles, has been demonstrated. The analysis time did not exceed 10 min.


Assuntos
Coronavirus , Vírus da Gastroenterite Transmissível , Acústica , Anticorpos , Condutividade Elétrica
11.
Sensors (Basel) ; 21(6)2021 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-33806805

RESUMO

Evanescent acoustic waves are characterized by purely imaginary or complex wavenumbers. Earlier, in 2019 by using a three dimensional (3D) finite element method (FEM) the possibility of the excitation and registration of such waves in the piezoelectric plates was theoretically shown. In this paper the set of the acoustically isolated interdigital transducers (IDTs) with the different spatial periods for excitation and registration of the evanescent acoustic wave in Y-cut X-propagation direction of lithium niobate (LiNbO3) plate was specifically calculated and produced. As a result, the possibility to excite and register the evanescent acoustic wave in the piezoelectric plates was experimentally proved for the first time. The evanescent nature of the registered wave has been established. The theoretical results turned out to be in a good agreement with the experimental ones. The influence of an infinitely thin layer with arbitrary conductivity placed on a plate surface was also investigated. It has been shown that the frequency region of an evanescent acoustic wave existence is very sensitive to the changes of the electrical boundary conditions. The results obtained may be used for the development of the method of the analysis of thin films electric properties based on the study of evanescent waves.

12.
Sensors (Basel) ; 20(10)2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32466322

RESUMO

A biological sensor for detection and identification of bacterial cells, including a resonator with a lateral electric field based on PZT ceramics was experimentally investigated. For bacterial immunodetection the frequency dependencies of the electric impedance of the sensor with a suspension of microbial cells were measured before and after adding the specific antibodies. It was found that the addition of specific antibodies to a suspension of microbial cells led to a significant change in these frequency dependencies due to the increase in the conductivity of suspension. The analysis of microbial cells was carried out in aqueous solutions with a conductivity of 4.5-1000 µS/cm, as well as in the tap and drinking water. The detection limit of microbial cells was found to be 103 cells/mLand the analysis time did not exceed 4 min. Experiments with non-specific antibodies were also carried out and it was shown that their addition to the cell suspension did not lead to a change in the analytical signal of the sensor. This confirms the ability to not only detect, but also identify bacterial cells in suspensions.


Assuntos
Bactérias , Técnicas Biossensoriais , Cerâmica , Condutividade Elétrica , Impedância Elétrica
13.
Sensors (Basel) ; 20(8)2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32326578

RESUMO

Novel bio-materials, like chitosan and its derivatives, appeal to finding a new niche in room temperature gas sensors, demonstrating not only a chemoresistive response, but also changes in mechanical impedance due to vapor adsorption. We determined the coefficients of elasticity and viscosity of chitosan acetate films in air, ammonia, and water vapors by acoustic spectroscopy. The measurements were carried out while using a resonator with a longitudinal electric field at the different concentrations of ammonia (100-1600 ppm) and air humidity (20-60%). It was established that, in the presence of ammonia, the longitudinal and shear elastic modules significantly decreased, whereas, in water vapor, they changed slightly. At that, the viscosity of the films increased greatly upon exposure to both vapors. We found that the film's conductivity increased by two and one orders of magnitude, respectively, in ammonia and water vapors. The effect of analyzed vapors on the resonance properties of a piezoelectric resonator with a lateral electric field that was loaded by a chitosan film on its free side was also experimentally studied. In these vapors, the parallel resonance frequency and maximum value of the real part of the electrical impedance decreased, especially in ammonia. The results of a theoretical analysis of the resonance properties of such a sensor in the presence of vapors turned out to be in a good agreement with the experimental data. It has been also found that with a growth in the concentration of the studied vapors, a decrease in the elastic constants, and an increase in the viscosity factor and conductivity lead to reducing the parallel resonance frequency and the maximum value of the real part of the electric impedance of the piezoelectric resonator with a lateral electric field that was loaded with a chitosan film. This leads to an increase in the sensitivity of such a sensor during exposure to these gas vapors.

14.
Sensors (Basel) ; 20(9)2020 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-32397502

RESUMO

The influence of humidity on the density, shear elastic module, viscosity, and thickness of the mushroom Pleurotus eryngii and Ganoderma lucidum mycelium films was studied. These data were obtained by comparing the theoretical and experimental frequency dependencies of the complex electrical impedance of bulk acoustic wave (BAW) resonator loaded by mycelium film using the least-squares method. This procedure was performed for the BAW resonator with pointed films for the relative humidity range of 17%-56% at the room temperature. As a result, the changes of the density, shear elastic module, viscosity, and thickness of the films under study, due to the water vapor adsorption, were determined. It has been established that the properties of mycelium films are restored after removing from the water vapor. So, these results show the possibility of using investigated mycelium films as sensitive layers for acoustic humidity sensors.


Assuntos
Acústica , Umidade , Micélio/química , Pleurotus/química , Reishi/química
15.
J Immunoassay Immunochem ; 37(5): 540-54, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27064236

RESUMO

This study performed a comparative estimation of the detection systems with the use of conjugates based on peroxidase, alkaline phosphatase, colloidal gold, and the amplification system "Super-CARD" for multiplex dot-immunoassay of antibodies. The results of the study show that the sensitivity of the detection system with colloidal gold was approximately 8 times higher than that of the system with amplification "Super-CARD", 30 times higher than that of the system with conjugate of alkaline phosphatase, and 250 times higher than the sensitivity of the system with the peroxidase conjugate. Gold immunosols limit the direct detection of human IgG of 10 pg with dynamic range of optical signal change from 5 ng to 10 pg. This limit corresponds to a range of concentrations of IgG from 2.5 µg/mL to 5 ng/mL and covers the range of specific IgG concentrations, to which a typical natural immune response leads. The most typical reasons for aggregate formation during obtainment of colloidal gold and the binding of colloidal gold with biocomponents were explored. The method of minimization of particle clusters formation was suggested as well as the method for increasing stability of diluted preparations of probe by means of sedimentation of aggregates from the ready-made product.


Assuntos
Imunoensaio/métodos , Imunoglobulina G/análise , Coloide de Ouro/química , Humanos , Imunoensaio/normas
16.
Gen Physiol Biophys ; 34(3): 311-21, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25730899

RESUMO

The action of a mixture of hormones (cortisol and adrenaline) on erythrocyte membrane during their binding was investigated. Changes in the membrane structure were elucidated by atomic force microscopy; microviscosity of the lipid bilayer and changes in the activity of Na(+),K(+)-ATPase at different concentrations of the hormones in erythrocyte suspension were estimated by the fluorescence method. Cortisol and adrenaline were shown to compete for the binding sites. A hormone that managed to bind nonspecifically to the membrane hindered the binding of another hormone. In a mixture of these hormones, cortisol won a competition for the binding sites; therewith, microviscosity of the membranes increased by 25%, which corresponds to a change in microviscosity produced by the action of cortisol alone. The competitive relationships affected also the Na(+),K(+)-ATPase activity, which was indicated by appearance of the second maximum of enzyme activity. It is assumed that an increase in microviscosity of erythrocyte membrane first raises the Na(+),K(+)-ATPase activity due to a growth of the maximum energy of membrane phonons, and then decreases the activity due to hindering of conformational transitions in the enzyme molecule.


Assuntos
Epinefrina/administração & dosagem , Membrana Eritrocítica/metabolismo , Membrana Eritrocítica/ultraestrutura , Hidrocortisona/administração & dosagem , Fluidez de Membrana/fisiologia , ATPase Trocadora de Sódio-Potássio/metabolismo , Animais , Células Cultivadas , Combinação de Medicamentos , Membrana Eritrocítica/efeitos dos fármacos , Masculino , Fluidez de Membrana/efeitos dos fármacos , Ratos , Ratos Wistar , Relação Estrutura-Atividade , Viscosidade
17.
J Mol Recognit ; 27(12): 727-38, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25319621

RESUMO

The specific interactions of the pairs laminin binding protein (LBP)-purified tick-borne encephalitis viral surface protein E and certain recombinant fragments of this protein, as well as West Nile viral surface protein E and certain recombinant fragments of that protein, are studied by combined methods of single-molecule dynamic force spectroscopy (SMDFS), enzyme immunoassay and optical surface waves-based biosensor measurements. The experiments were performed at neutral pH (7.4) and acid pH (5.3) conditions. The data obtained confirm the role of LBP as a cell receptor for two typical viral species of the Flavivirus genus. A comparison of these data with similar data obtained for another cell receptor of this family, namely human αVß3 integrin, reveals that both these receptors are very important. Studying the specific interaction between the cell receptors in question and specially prepared monoclonal antibodies against them, we could show that both interaction sites involved in the process of virus-cell interaction remain intact at pH 5.3. At the same time, for these acid conditions characteristic for an endosome during flavivirus-cell membrane fusion, SMDFS data reveal the existence of a force-induced (effective already for forces as small as 30-70 pN) sharp globule-coil transition for LBP and LBP-fragments of protein E complexes. We argue that this conformational transformation, being an analog of abrupt first-order phase transition and having similarity with the famous Rayleigh hydrodynamic instability, might be indispensable for the flavivirus-cell membrane fusion process.


Assuntos
Vírus da Encefalite Transmitidos por Carrapatos/fisiologia , Laminina/metabolismo , Fusão de Membrana , Estresse Mecânico , Internalização do Vírus , Humanos , Concentração de Íons de Hidrogênio , Integrina alfaVbeta3/metabolismo , Cinética , Ligantes , Ligação Proteica , Receptores de Superfície Celular/metabolismo , Proteínas Recombinantes/metabolismo , Análise Espectral , Termodinâmica , Proteínas do Envelope Viral/química , Proteínas do Envelope Viral/metabolismo
18.
Ultrasonics ; 142: 107386, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38971006

RESUMO

An experimental study of the dependence of the electrical impedance of a lateral electric field resonator on its thickness and the size of the gap between the electrodes was carried out. The resonator was made of PZT-19 piezoceramics in the form of a rectangular parallelepiped with the shear dimensions of 18 × 20 mm2. Two rectangular electrodes with a gap that varied in the range from 4 to 14 mm were applied on one side of the resonator. For each gap width, the frequency dependences of the real and imaginary parts of the electrical impedance were measured using an impedance analyzer. It has been found that increasing the gap width leads to an increase in the resonant frequency and to an increase in the maximum value of the real part of the impedance. Three series of such experiments were carried out for three values of the resonator thickness: 3.02, 2.38 and 1.9 mm. The resonant characteristics of the resonator were also theoretically analyzed by finite element analysis using two models. One resonator model was based on a two-dimensional finite element method. In this case, the vibration modes that existed due to the finite size of the plate in the direction parallel to the gap between the electrodes were not taken into account. The second model of the resonator used a three-dimensional finite element method, which correctly took into account all vibration modes existing in the resonator. Comparison of theory with experiment has shown that the three-dimensional model provides a better agreement between theoretical and experimental results.

19.
Clin Neurol Neurosurg ; 236: 108080, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38113657

RESUMO

BACKGROUND: Primary trigeminal neuralgia (PTN) is a prevalent chronic pain disorder whose pathogenesis is not limited to the trigeminal system. Despite the significant advances in uncovering underlying mechanisms, there is a paucity of comprehensive and consistent data regarding the role of white matter throughout the entire brain in PTN. METHODS: We performed a prospective case-control study. Sixty patients with PTN and 28 age- and sex-matched healthy controls were evaluated using diffusion tensor imaging (DTI). A tract-based spatial statistical approach was performed to investigate white matter impairment in patients with PTN with several metrics, including fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD) and axial diffusivity (AD). Additionally, ROI-based analysis was performed for each white matter tract to compare FA values between groups with correction for patient age and sex. Correlations between DTI data and nerve root compression severity, as well as pain severity, were also evaluated in patients with PTN. RESULTS: Our analysis demonstrated a widespread and symmetrical reduction in FA values among TN patients when compared to the control group (p < 0.05). Specifically, this FA decrease was predominantly observed in regions such as the corona radiata, internal capsule, optic radiation, and thalami, as well as structures within the posterior fossa, notably the cerebellar peduncles. No statistically significant differences were found between patients and the control group during the MD, AD and RD map analyses. ROI-based analysis did not reveal statistically significant changes in FA values in white matter tracts (p > 0.05 in all comparisons, FDR-corrected); however, there were trends towards FA value decreases in the internal capsule (p = 0.08, FDR-corrected) and inferior fronto-occipital fasciculus (p = 0.09, FDR-corrected). CONCLUSIONS: Our findings indicate the presence of microstructural abnormalities in white matter among individuals with primary trigeminal neuralgia, which may potentially play a role in the development and progression of the condition.


Assuntos
Neuralgia do Trigêmeo , Substância Branca , Humanos , Imagem de Tensor de Difusão/métodos , Neuralgia do Trigêmeo/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Estudos de Casos e Controles , Encéfalo/patologia , Anisotropia
20.
Front Neurosci ; 17: 1102691, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36925743

RESUMO

Background: White matter myelination is a crucial process of CNS maturation. The purpose of this study was to validate the T1w/T2w mapping technique for brain myelination assessment in infants and young children. Methods: Ninety-four patients (0-23 months of age) without structural abnormalities on brain MRI were evaluated by using the T1w/T2w mapping method. The T1w/T2w signal intensity ratio, which reflects white matter integrity and the degree of myelination, was calculated in various brain regions. We performed a Pearson correlation analysis, a LOESS regression analysis, and a 2nd order polynomial regression analysis to describe the relationships between the regional metrics and the age of the patients (in months). Results: T1w/T2w ratio values rapidly increased in the first 6-9 months of life and then slowed thereafter. The T1w/T2w mapping technique emphasized the contrast between myelinated and less myelinated structures in all age groups, which resulted in better visualization. There were strong positive correlations between the T1w/T2w ratio values from the majority of white matter ROIs and the subjects' age (R = 0.7-0.9, p < 0.001). Within all of the analyzed regions, there were non-linear relationships between age and T1/T2 ratio values that varied by anatomical and functional location. Regions such as the splenium and the genu of the corpus callosum showed the highest R2 values, thus indicating less scattering of data and a better fit to the model. Conclusion: The T1w/T2w mapping technique may enhance our diagnostic ability to assess myelination patterns in the brains of infants and young children.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA