Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Heart Fail Rev ; 29(3): 615-630, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38289525

RESUMO

Acute decompensated heart failure and fluid overload are the most common causes of hospitalization in heart failure patients, and often, they contribute to disease progression. Initial treatment encompasses intravenous diuretics although there might be a percentual of patients refractory to this pharmacological approach. New technologies have been developed to perform extracorporeal ultrafiltration in fluid overloaded patients. Current equipment allows to perform ultrafiltration in most hospital and acute care settings. Extracorporeal ultrafiltration is then prescribed and conducted by specialized teams, and fluid removal is planned to restore a status of hydration close to normal. Recent clinical trials and European and North American practice guidelines suggest that ultrafiltration is indicated for patients with refractory congestion not responding to medical therapy. Close interaction between nephrologists and cardiologists may be the key to a collaborative therapeutic effort in heart failure patients. Further studies are today suggesting that wearable technologies might become available soon to treat patients in ambulatory and de-hospitalized settings. These new technologies may help to cope with the increasing demand for the care of chronic heart failure patients. Herein, we provide a state-of-the-art review on extracorporeal ultrafiltration and describe the steps in the development of a new miniaturized system for ultrafiltration, called AD1 (Artificial Diuresis).


Assuntos
Insuficiência Cardíaca , Ultrafiltração , Humanos , Insuficiência Cardíaca/terapia , Ultrafiltração/métodos , Ultrafiltração/instrumentação , Miniaturização , Desenho de Equipamento , Hemofiltração/instrumentação , Hemofiltração/métodos
2.
Artif Organs ; 48(5): 543-549, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38156403

RESUMO

BACKGROUND: The level of bacteremia in patients with sepsis and septic shock is a predictor of complications and mortality, regardless of the type of bacteria. Devices for bacteria, endotoxin and cytokines removal by adsorption have been recently developed. Thus, extracorporeal blood purification therapies have been proposed as adjunctive therapy in sepsis in combination with drugs. Some potentially useful drugs, however, are precluded due to their organ or metabolic toxicity. The present study represents a preliminary report on the in vitro effect of a sorbent device (minimodule with HA380 beads, Jafron medical, Zhuhai, China) in which the particles have been functionalized with vancomycin on the surface. The impact of the surface-modified beads on circulating bacteria (Staphylococcus aureus) has been tested in a simulated in vitro circulation. METHODS: In vitro experiments were carried out with 800 mL of blood enriched with S. aureus species. Blood was circulated in the vancomycin-functionalized and non-functionalized mini-module cartridges in hemoadsorption setup (300 mL each) and the bactericidal effect was assessed. Also, 200 mL of blood was used as a control. RESULTS: A significant increase in the time to positivity of blood cultures was observed after 60 min and also after 120 min of therapy with the mini-module functionalized with vancomycin as opposed to the non-functionalized cartridge. CONCLUSIONS: These results suggest a possible way of treating sepsis by using drug- or antibiotic-functionalized cartridges without worrying about pharmacological toxicity. The prolongation of the time to bacterial culture positivity to S. aureus after a passage through a column packed with beads functionalized with vancomycin represents a proof of concept.


Assuntos
Bacteriemia , Sepse , Humanos , Vancomicina/farmacologia , Staphylococcus aureus , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Sepse/tratamento farmacológico , Bacteriemia/tratamento farmacológico
3.
Blood Purif ; 53(6): 500-504, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38281478

RESUMO

INTRODUCTION: Hemadsorption with new sorbent cartridges is an emerging extracorporeal blood purification technique. Flow distribution inside the sorbent is one of the main issues concerning the device's performance and optimal sorbent utilization. In this experiment, we aimed to investigate the efficacy of vibration during adsorption by measuring the removal of vancomycin. METHODS: In this experimental study, 1,000 mL of saline with 10 g of vancomycin was circulated in a closed circuit (set flow of 250 mL/min) simulating a hemadsorption blood run using HA380 minimodule cartridge containing 75 g of wet resin. This vibration model was implemented with a damping head device installed in front of the adsorption cartridge during the experiment. The kinetics of the vancomycin were assessed by removal ratio over 120 min. RESULTS: We found no difference between the two models. Adsorption with and without vibration did not differ significantly for partial reduction ratios, overall amount of adsorbed molecule, or adsorption kinetics. CONCLUSION: The current design and structure of the minimodule cartridge demonstrated no difference in small-middle solute removal. Further improvement with the addition of mechanical vibration to the device was not observed.


Assuntos
Vancomicina , Vibração , Adsorção , Cinética , Hemoperfusão/métodos , Hemoperfusão/instrumentação , Humanos
4.
Blood Purif ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38493768

RESUMO

INTRODUCTION: Per- and polyfluoroalkyl substances (PFAS) are known water pollutants leading to potential public health consequences. High blood levels of PFAS have been associated with several pathological conditions including testicular and kidney cancer. Classic extracorporeal therapies have demonstrated limited efficiency and new approaches should be explored. In this study we studied the possible role of hemoadsorption to achieve a fast, safe and effective removal of PFAS from blood in patients with high blood levels. METHODS: We developed an in vitro model of hemoadsorption to test the potential of PFAS removal by extracorporeal treatment. We recirculated a highly polluted batch of water (4 liters) through a sorbent cartridge (Jafron medical, Zuhai, China) for 120 minutes at a flow of 150 mL/min. We collected samples at different time points and analyzed 39 different PFAS compounds. RESULTS: For the PFAS compounds with concentrations significantly above normal, we observed a removal ratio close to 90% already within the first 60 minutes of circulation leading to almost complete elimination of all pollutants at 120 minutes. CONCLUSIONS: The in vitro model of hemoadsorption suggests the possible application in vivo of this technique to reduce/normalize the concentrations of PFAS in patients exposed to water or environmental pollution.

5.
Blood Purif ; 53(4): 316-324, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37992697

RESUMO

INTRODUCTION: The present study aimed to monitor peritoneal neutrophil gelatinase-associated lipocalin (pNGAL) during peritonitis episodes and to enhance its diagnostic value by evaluating pNGAL at scheduled times in parallel with white blood cell (WBC) count. In addition, we investigated possible correlations between pNGAL and the etiology of peritonitis, evaluating it as a possible marker of the clinical outcome. METHODS: Twenty-two patients with peritoneal dialysis (PD)-related peritonitis were enrolled. Peritonitis was divided into Gram-positive, Gram-negative, polymicrobial, and sterile. WBC count and neutrophil gelatinase-associated lipocalin (NGAL) in PD effluent were measured at different times (days 0, 1, 5, 10, 15, and/or 20 and 10 days after antibiotic therapy discontinuation). NGAL was measured by standard quantitative laboratory-based immunoassay and by colorimetric NGAL dipstick (NGALds) (dipstick test). RESULTS: We found strong correlations between peritoneal WBC, laboratory-based NGAL, and NGALds values, both overall and separated at each time point. On day 1, we observed no significant difference in WBC, both NGALds (p = 0.3, 0.9, and 0.2) between Gram-positive, Gram-negative, polymicrobial, and sterile peritonitis. No significant difference has been found between de novo versus relapsing peritonitis for all markers (p > 0.05). We observed a parallel decrease of WBC and both NGAL in patients with favorable outcomes. WBC count and both pNGAL resulted higher in patients with negative outcomes (defined as relapsing peritonitis, peritonitis-associated catheter removal, peritonitis-associated hemodialysis transfer, peritonitis-associated death) at day 10 (p = 0.04, p = 0.03, and p = 0.05, respectively) and day 15 (p = 0.01, p = 0.04, and tendency for p = 0.005). There was a tendency toward higher levels of WBC and NGAL in patients with a negative outcome at day 5. No significant difference in all parameters was proven at day 1 (p = 0.3, p = 0.9, p = 0.2) between groups. CONCLUSION: This study confirms pNGAL as a valid and reliable biomarker for the diagnosis of PD-peritonitis and its monitoring. Its trend is parallel to WBC count during peritonitis episodes, in particular, patients with unfavorable outcomes.


Assuntos
Diálise Peritoneal , Peritonite , Humanos , Lipocalina-2 , Proteínas de Fase Aguda/metabolismo , Proteínas de Fase Aguda/uso terapêutico , Lipocalinas/metabolismo , Lipocalinas/uso terapêutico , Proteínas Proto-Oncogênicas/metabolismo , Proteínas Proto-Oncogênicas/uso terapêutico , Diálise Peritoneal/efeitos adversos , Peritonite/diagnóstico , Peritonite/etiologia , Peritonite/tratamento farmacológico , Biomarcadores/metabolismo , Leucócitos/metabolismo
6.
Int J Mol Sci ; 25(8)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38673869

RESUMO

Erythrocytes (RBCs) have a highly specialized and organized membrane structure and undergo programmed cell death, known as eryptosis. Our preliminary data show a significant increase in the eryptosis during peritoneal dialysis (PD)-associated peritonitis. The objectives of the present study were assessment of the incrementation of eryptosis in PD patients with peritonitis, evaluation of the relationship between systemic eryptosis in peritonitis and specific peritonitis biomarkers in PD effluent (PDE), and confirmation of the induction of eryptosis by peritonitis in a vitro setting. We enrolled 22 PD patients with peritonitis and 17 healthy subjects (control group, CTR). For the in vivo study, eryptosis was measured in freshly isolated RBCs. For the in vitro study, healthy RBCs were exposed to the plasma of 22 PD patients with peritonitis and the plasma of the CTR group for 2, 4, and 24 h. Eryptosis was evaluated by flow cytometric analyses in vivo and in vitro. PDE samples were collected for biomarkers analysis.The percentage of eryptotic RBCs was significantly higher in PD patients with peritonitis than in CTR (PD patients with peritonitis: 7.7; IQR 4.3-14.2, versus CTR: 0.8; IQR 0.7-1.3; p < 0.001). We confirmed these in vivo results by in vitro experiments: healthy RBCs incubated with plasma from PD patients with peritonitis demonstrated a significant increase in eryptosis compared to healthy RBCs exposed to plasma from the control group at all times. Furthermore, significant positive correlations were observed between eryptosis level and all analyzed peritoneal biomarkers of peritonitis. We investigated a potential connection between systemic eryptosis and peritoneal biomarkers of peritonitis. Up-regulation of inflammatory markers could explain the increased rate of systemic eryptosis during PD-related peritonitis.


Assuntos
Biomarcadores , Eriptose , Eritrócitos , Diálise Peritoneal , Peritonite , Humanos , Peritonite/metabolismo , Peritonite/etiologia , Peritonite/patologia , Masculino , Feminino , Diálise Peritoneal/efeitos adversos , Pessoa de Meia-Idade , Eritrócitos/metabolismo , Biomarcadores/sangue , Idoso , Adulto , Inflamação/metabolismo , Inflamação/patologia , Inflamação/etiologia , Estudos de Casos e Controles
7.
Blood Purif ; 52(2): 174-182, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36096119

RESUMO

INTRODUCTION: Sepsis is a frequent complication in critically ill patients. Patients may require control of the source of infection, removal of pathogens and damaged cells, and organ support. Often, these targets can be achieved through the utilization of extracorporeal therapies including hemoperfusion for the adsorption of cytokines and other circulating mediators. On extracorporeal organ support, patients are generally treated with antibiotic therapy, and vancomycin is one of the most commonly used antibiotics. Because of the aspecific nature of adsorption, antibiotics can be removed from the circulation, leading to altered plasma levels and requiring prescription adjustment. The aim was to define the amount of vancomycin adsorbed by a sorbent cartridge (HA380, Jafron, China) during hemoperfusion and to establish possible strategies to maintain an effective plasma level in critically ill patients undergoing extracorporeal therapies. METHODS: In vitro experiments with incremental concentrations of vancomycin in the test solution (500 and 1,000 mL) were carried out in a recirculation circuit until sorbent saturation was observed. A maximum of 10 g of vancomycin were injected and mini-modules containing 25 g of dry resin were utilized. RESULTS: In different experiments with various concentration of vancomycin, a maximum amount of 244 mg/g of sorbent was adsorbed reaching saturation between 60 and 80 min from the beginning of the experiments. The kinetics of adsorption appears to be governed by a Langmuir-like isotherm with maximal removal speed in the early minutes and a plateau after 60 min. DISCUSSION/CONCLUSION: HA380 adsorbs significant amounts of vancomycin. Adjusting the achieved results with the experimental mini-module to a full-scale cartridge, a total of 25 g of antibiotic can be removed. This might have affected outcome results in clinical trials. This suggests prescribing administration to critically ill patients requiring hemoperfusion, immediately after or in the inter-session time window. In case of administration during hemoperfusion, adequate adjustment and plasma level monitoring is strongly recommended.


Assuntos
Hemoperfusão , Humanos , Hemoperfusão/métodos , Vancomicina , Adsorção , Estado Terminal , Antibacterianos
8.
Blood Purif ; 52(3): 242-254, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36657410

RESUMO

A hallmark of chronic kidney disease is the retention of solutes that normally are eliminated by the kidneys. The current classification defines uremic toxins based on molecular weight and protein affinity. The retention of solutes is already detected in the early stages of the disease when patients are pauci-symptomatic or asymptomatic but the role of therapies to retard the loss of kidney function in patients with chronic kidney disease (e.g., modulators of the renin-angiotensin-aldosterone system, sodium-glucose cotransporter inhibitors) in reducing uremic toxins is poorly understood. Most of the research evaluating the impact of therapies to lower serum concentrations of those toxic compounds is carried out in patients with kidney failure already undergoing kidney replacement therapy. The removal of those molecules relies in physicochemical mass transfer phenomena, i.e., adsorption, diffusion, and convection. In the past 2 decades, the rise and broad adoption of blood purification strategies with enhanced convective properties, such as high-volume online hemodiafiltration and expanded hemodialysis, considerably amplified the ability to mechanically extract middle molecules (molecular weight >0.5 kDa) from the blood compartment. Nonetheless, the classification of uremic toxins has not evolved in parallel with dialysis advancements. Mounting evidence demonstrates the link between middle molecules with uremic symptoms, cardiovascular and mortality risks. An urgent need for updating the classification exists. Defining the causative relationship between specific solutes and specific clinical outcomes will promote the development of targeted therapies. In parallel, the inclusion of new pertinent dimensions to the classification like the influence of new dialysis membranes, sorbents, and intestinal chelators in the concentration of uremic toxins would improve the understanding of the pathogenesis of chronic kidney disease, setting the pace for future research in nephrology.


Assuntos
Hemodiafiltração , Falência Renal Crônica , Insuficiência Renal Crônica , Toxinas Biológicas , Uremia , Humanos , Diálise Renal/efeitos adversos , Toxinas Urêmicas , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Hemodiafiltração/métodos , Falência Renal Crônica/terapia , Toxinas Biológicas/metabolismo
9.
Blood Purif ; 52(4): 345-351, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36580898

RESUMO

BACKGROUND: Extracorporeal removal of bilirubin in patients with severe liver dysfunction is a key blood purification strategy. We conducted an ex vivo study to assess the quantitative capacity to remove bilirubin from plasma of a novel adsorptive cartridge. METHODS: We studied a downscaled module of the BS330 Plasma Bilirubin Adsorption Column Cartridge (Jafron Biomedical, Zhuhai City, China) to minimize the plasma requirement in an ex vivo circulation using a solution of hyperbilirubinemic plasma. We measured the bilirubin concentration gap (ΔC) between inlet (Cpin) and outlet (Cpout) of the unit and we calculated the removal ratio (RR) as mass adsorbed at different time points. Moreover, we compared the ex vivo model with the bilirubin adsorption kinetics in a patient with acute on chronic liver failure treated with the BS330 cartridge. RESULTS: Bilirubin concentration change across the cartridge at 30 min was 16.5%, and cartridge saturation was reached at 750 min. We used a minimodule downscaled to 1:3 and containing approximately 131 g of BS330 sorbent beads: the device retained 759 mg of bilirubin with a RR of 78.1% and a RR of 42.6% at 120 min. Thus, the adsorption capacity was 5.76 mg of bilirubin per gram of sorbent. Bilirubin adsorption kinetics in our clinical case with a full-scale unit shows a coherent trend with a total bilirubin mass adsorbed after 180 min of 470 mg. DISCUSSION: Our findings provide the first assessment of bilirubin adsorption in an ex vivo model of plasma perfusion and can be used to design interventional studies in humans, providing guidance for an adequate prescription of treatment frequency and duration.


Assuntos
Bilirrubina , Hemoperfusão , Humanos , Adsorção , Cinética , Hiperbilirrubinemia
10.
Int J Mol Sci ; 24(18)2023 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-37762478

RESUMO

Sepsis is a life-threatening multiple-organ dysfunction induced by infection and is one of the leading causes of mortality and critical illness worldwide. The pathogenesis of sepsis involves the alteration of several biochemical pathways such as immune response, coagulation, dysfunction of endothelium and tissue damage through cellular death and/or apoptosis. Recently, in vitro and in vivo studies reported changes in the morphology and in the shape of human red blood cells (RBCs) causing erythrocyte death (eryptosis) during sepsis. Characteristics of eryptosis include cell shrinkage, membrane blebbing, and surface exposure to phosphatidylserine (PS), which attract macrophages. The aim of this study was to evaluate the in vitro induction of eryptosis on healthy RBCs exposed to septic plasma at different time points. Furthermore, we preliminary investigated the in vivo levels of eryptosis in septic patients and its relationship with Endotoxin Activity Assay (EAA), mortality and other biological markers of inflammation and oxidative stress. We enrolled 16 septic patients and 16 healthy subjects (no systemic inflammation in the last 3 months) as a control group. At diagnosis, we measured Interleukin-6 (IL-6) and Myeloperoxidase (MPO). For in vitro study, healthy RBCs were exposed to the plasma of septic patients and CTR for 15 min, 1, 2, 4 and 24 h. Morphological markers of death and eryptosis were evaluated by flow cytometric analyses. The cytotoxic effect of septic plasma on RBCs was studied in vitro at 15 min, 1, 2, 4 and 24 h. Healthy RBCs incubated with plasma from septic patients went through significant morphological changes and eryptosis compared to those exposed to plasma from the control group at all time points (all, p < 0.001). IL-6 and MPO levels were significantly higher in septic patients than in controls (both, p < 0.001). The percentage of AnnexinV-binding RBCs was significantly higher in septic patients with EAA level ≥0.60 (positive EAA: 32.4%, IQR 27.6-36.2) compared to septic patients with EAA level <0.60 (negative EAA: 14.7%, IQR 5.7-30.7) (p = 0.04). Significant correlations were observed between eryptosis and EAA levels (Spearman rho2 = 0.50, p < 0.05), IL-6 (Spearman rho2 = 0.61, p < 0.05) and MPO (Spearman rho2 = 0.70, p < 0.05). In conclusion, we observed a quick and great cytotoxic effect of septic plasma on healthy RBCs and a strong correlation with other biomarkers of severity of sepsis. Based on these results, we confirmed the pathological role of eryptosis in sepsis and we hypothesized its use as a biomarker of sepsis, potentially helping physicians to face important treatment decisions.


Assuntos
Antineoplásicos , Eriptose , Sepse , Humanos , Interleucina-6 , Eritrócitos
11.
Blood Purif ; 51(9): 726-731, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34883486

RESUMO

INTRODUCTION: A well-functioning peritoneal catheter is key to success of peritoneal dialysis (PD). The Vicenza "short" catheter is a modified Tenckhoff catheter with a shorter intraperitoneal segment. The aim of this study was to evaluate the incidence of catheter-related complications and catheter survival rate using the Vicenza "short" catheter, according to the goals suggested by the International Society for Peritoneal Dialysis (ISPD) guidelines. Second, we compared insertion techniques used in our center. METHODS: This is a retrospective cohort, single-center study analyzing incident PD patients undergoing Vicenza "short" peritoneal catheter placement between January 1, 2015, and December 31, 2019. As clinical outcomes, we evaluated catheter patency at 12 months, exit-site/tunnel infection and peritonitis within 30 days of catheter insertion, visceral injury, or significant hemorrhage during the procedure, in accordance with ISPD guidelines. RESULTS: The percentage of patency at 12 months for all catheter insertion methods was 88.91%, and the percentage for laparoscopic placement was 93.75%. The exit-site/tunnel infection and peritonitis occurring within 30 days of catheter insertion were, respectively, 0.75% and 2.2%; the visceral injury leading to intervention was 0.75%. We did not have any case of significant hemorrhage. All results were in line with ISPD guidelines. CONCLUSION: We conclude that the Vicenza "short" catheter is a suitable device for peritoneal access. The implantation procedure is safe and easy to perform, and both nephrologists and surgeons can do it. A confident use and a proper implantation of the Vicenza "short" catheter help achieve the clinical ISPD goals for the PD access procedure in terms of catheter survival and complication rates.


Assuntos
Diálise Peritoneal , Peritonite , Cateterismo/efeitos adversos , Cateterismo/métodos , Cateteres de Demora/efeitos adversos , Humanos , Diálise Peritoneal/métodos , Peritonite/etiologia , Complicações Pós-Operatórias , Estudos Retrospectivos
12.
Blood Purif ; 51(11): 912-922, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35263746

RESUMO

INTRODUCTION: At the time of renal replacement therapy, approximately 20% of critically ill patients have septic shock. In this study, medium cutoff (MCO) continuous venovenous hemodialysis (CVVHD) was compared to high-flux membrane continuous venovenous hemodiafiltration (CVVHDF) in terms of hemodynamic improvement, efficiency, middle molecule removal, and inflammatory system activation. METHODS: This is a monocenter crossover randomized study. Between December 31, 2017, and December 31, 2019, 20 patients with septic shock and stage 3 acute kidney injury (AKI) admitted to 2 Italian ICUs were enrolled. All patients underwent CVVHD with Ultraflux® EMiC®2 and CVVHDF with AV1000S® without washout. Each treatment lasted 24 h. RESULTS: Compared to AV1000S®-CVVHDF, EMIC®2-CVVHD normalized cardiac index (ß = -0.64; p = 0.02) and heart rate (ß = 5.72; p = 0.01). Interleukin-8 and myeloperoxidase removal were greater with AV1000S®-CVVHDF than with EMiC®2-CVVHD (ß = 0.35; p < 0.001; ß = 0.43; p = 0.03, respectively). Leukocytosis improved over 24 h in EMiC®2-CVVHD-treated patients (ß = 4.13; p = 0.03), whereas procalcitonin levels decreased regardless of the modality (ß = 0.89; p = 0.01) over a 48-h treatment period. Reduction rates, instantaneous plasmatic clearance of urea, creatinine, and ß2-microglobulin were similar across modalities. ß2-Microglobulin removal efficacy was greater in the EMiC®2 group (ß = 0-2.88; p = 0.002), while albumin levels did not differ. Albumin was undetectable in the effluent in both treatments. DISCUSSION: In patients with septic shock and severe AKI, the efficacy of uremic toxin removal was comparable between MCO-CVVHD and CVVHDF. Further, MCO-CVVHD was associated with improved hemodynamics. Fraction of filtration and transmembrane pressure reduction and the maintenance of equal efficacy might be the key features of CVVHD with MCO membranes in critically ill patients.


Assuntos
Injúria Renal Aguda , Terapia de Substituição Renal Contínua , Hemodiafiltração , Choque Séptico , Humanos , Choque Séptico/terapia , Choque Séptico/etiologia , Estado Terminal , Diálise Renal , Injúria Renal Aguda/terapia , Albuminas , Hemodiafiltração/efeitos adversos
13.
Nephrol Dial Transplant ; 34(2): 308-317, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30053231

RESUMO

Background: Cardiac surgery is a leading cause of acute kidney injury (AKI). Such AKI patients may develop progressive chronic kidney disease (CKD). Others, who appear to have sustained no permanent loss of function (normal serum creatinine), may still lose renal functional reserve (RFR). Methods: We extended the follow-up in the observational 'Preoperative RFR Predicts Risk of AKI after Cardiac Surgery' study from hospital discharge to 3 months after surgery for 86 (78.2%) patients with normal baseline estimated glomerular filtration rate (eGFR), and re-measured RFR with a high oral protein load. The primary study endpoint was change in RFR. Study registration at clinicaltrials.gov Identifier: NCT03092947, ISRCTN Registry: ISRCTN16109759. Results: At 3 months, three patients developed new CKD. All remaining patients continued to have a normal eGFR (93.3 ± 15.1 mL/min/1.73 m2). However, when stratified by post-operative AKI and cell cycle arrest (CCA) biomarkers, AKI patients displayed a significant decrease in RFR {from 14.4 [interquartile range (IQR) 9.5 - 24.3] to 9.1 (IQR 7.1 - 12.5) mL/min/1.73 m2; P < 0.001} and patients without AKI but with positive post-operative CCA biomarkers also experienced a similar decrease of RFR [from 26.7 (IQR 22.9 - 31.5) to 19.7 (IQR 15.8 - 22.8) mL/min/1.73 m2; P < 0.001]. In contrast, patients with neither clinical AKI nor positive biomarkers had no such decrease of RFR. Finally, of the three patients who developed new CKD, two sustained AKI and one had positive CCA biomarkers but without AKI. Conclusions: Among elective cardiac surgery patients, AKI or elevated post-operative CCA biomarkers were associated with decreased RFR at 3 months despite normalization of serum creatinine. Larger prospective studies to validate the use of RFR to assess renal recovery in combination with biochemical biomarkers are warranted.


Assuntos
Injúria Renal Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias/complicações , Cardiopatias/cirurgia , Insuficiência Renal Crônica/etiologia , Biomarcadores/sangue , Creatinina/sangue , Feminino , Seguimentos , Taxa de Filtração Glomerular , Humanos , Rim/fisiopatologia , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Período Pós-Operatório , Estudos Prospectivos
14.
Blood Purif ; 47(1-3): 270-276, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30522094

RESUMO

BACKGROUND: Sepsis is a life-threatening condition often associated with a high incidence of multiple organs injury. Several papers suggested the immune response by itself, with the production of humoral inflammatory mediators, is crucial in determining organ injury. However, little is known of how sepsis directly induces organ injury at the cellular levels. To assess this point, we set up an in vitro study to investigate the response of renal tubular cells (RTCs), monocytes (U937) and hepatocytes (HepG2) after 24 h-incubation with septic patients' plasma. METHODS: We enrolled 26 septic patients ("test" group). We evaluated cell viability, apoptosis and necrosis by flow cytometer. Caspase-3,-8,-9 and cytochrome-c concentrations have been analyzed using the Human enzyme-linked immunosorbent assay kit. RESULTS: We found that a decrease of cell viability in all cell lines tested was associated to the increase of apoptosis in RTCs and U937 (p < 0.0001) and increase of necrosis in HepG2 (p < 0.5). The increase of apoptosis in RTCs and U937 cells was confirmed by higher levels of caspase-3 (p < 0.0001). We showed that apoptosis in both RTCs and U937 was triggered by the activation of the intrinsic pathway, as caspase-9 and cytochrome-c levels significantly increased (p < 0.0001), while caspase-8 did not change. This assumption was strengthened by the significant correlation of caspase-9 with both cytochrome-c (r = 0.73 for RTCs and r = 0.69 for U937) and caspase-3 (r = 0.69 for RTCs and r = 0.63 for U937). CONCLUSION: Humoral mediators in septic patients' plasma induce apoptosis. This fact suggests that apoptosis inhibitors should be investigated as future strategy to reduce sepsis-induced organ damages.


Assuntos
Apoptose , Hepatócitos/metabolismo , Túbulos Renais Proximais/metabolismo , Monócitos/metabolismo , Plasma , Sepse/sangue , Caspases/metabolismo , Sobrevivência Celular , Citocromos c/metabolismo , Células Hep G2 , Hepatócitos/patologia , Humanos , Túbulos Renais Proximais/patologia , Monócitos/patologia , Células U937
15.
Blood Purif ; 47(1-3): 140-148, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30336490

RESUMO

Backgound: This study was aimed at evaluating the presepsin and procalcitonin levels to predict adverse postoperative complications and mortality in cardiac surgery patients. METHODS: A total of 122 cardiac surgery patients were enrolled for the study. Presepsin and procalcitonin levels were measured 48 h after the procedure. The primary endpoints were adverse renal, respiratory, and cardiovascular outcomes and mortality. RESULTS: Presepsin and procalcitonin levels were significantly higher in patients with adverse renal and respiratory outcome (p < 0.001 and 0.0081). The presepsin levels were significantly higher in patients with adverse cardiovascular outcome (p = 0.023) and the procalcitonin values in patients with sepsis (p = 0.0013). Presepsin levels were significantly higher in patients who died during hospitalization (382 pg/mL, interquartile range [IQR] 243-717.5 vs. 1,848 pg/mL, IQR 998-5,451.5, p = 0.049). In addition, the predictive value for in-hospital, 30-days, and 6-months mortality was higher for presepsin, with a significant difference between the 2 biomarkers (p = 0.025, p = 0.035, p = 0.003; respectively). Presepsin and procalcitonin seem to have comparable predictive value for adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Although a positive trend was notable for presepsin and adverse renal outcome (area under the ROC [receiver operating characteristic] curves [AUC] of 0.760, 95% CI 0.673-0.833 versus procalcitonin: AUC 0.692; 95% CI 0.601-0.773): no statistically significant difference was evident between the AUC of the 2 biomarkers (p = 0.25). CONCLUSIONS: Presepsin and -procalcitonin seem to have comparable predictive value for -adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Also, presepsin possesses a better predictive value for in-hospital, 30-days, and 6-months mortality.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Mortalidade Hospitalar , Receptores de Lipopolissacarídeos/sangue , Fragmentos de Peptídeos/sangue , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/mortalidade , Pró-Calcitonina/sangue , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
16.
Blood Purif ; 48(1): 60-66, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30712031

RESUMO

BACKGROUND: ACUsmart (Medica S.P.A., Italy) is a new-generation, continuous renal replacement therapy (CRRT) machine for critically ill patients with acute kidney injury. We designed a multicenter international pilot study to provide a description of outlines of the ACUsmart system, evaluation aspects of functionality, usability, and feasibility, discriminating reasons of possible treatment's withdrawals or discontinuations and highlighting strong and weak points of the machine. METHODS: Data of 23 CRRT (and 11 plasma exchange) treatments were collected from 4 intensive care units. Parameters such as treatment duration, downtime, delivered dose, and number and type of alarms were recorded. The general perception of the machine was quantified through the administration of a survey to each component of the evaluating staff. RESULTS: A total treatment time of 447 h was carried with ACUsmart. Eleven continuous veno-venous hemofiltration, 4 continuous veno-venous hemodialysis , and 8 continuous veno-venous hemodiafiltration were performed. The average percentage of net treatment duration with respect to total treatment duration was 92.37%. The mean prescribed dose and delivered dose were 26.33 and 24.10 mL/kg/h, respectively. In general, the machine was rated by users involved as practical and easy to use, although few components need to be slightly improved. CONCLUSION: ACUsmart is a new multifunctional machine that meets most of the features required in a fourth-generation CRRT equipment.


Assuntos
Injúria Renal Aguda/terapia , Estado Terminal/terapia , Terapia de Substituição Renal/instrumentação , Terapia de Substituição Renal/métodos , Humanos , Projetos Piloto , Terapia de Substituição Renal/efeitos adversos , Projetos de Pesquisa , Resultado do Tratamento , Interface Usuário-Computador
17.
Lancet ; 383(9931): 1807-13, 2014 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-24856026

RESUMO

BACKGROUND: Peritoneal dialysis is the renal replacement therapy of choice for acute kidney injury in neonates, but in some cases is not feasible or effective. Continuous renal replacement therapy (CRRT) machines are used off label in infants smaller than 15 kg and are not designed specifically for small infants. We aimed to design and create a CRRT machine specifically for neonates and small infants. METHODS: We prospectively planned a 5-year project to conceive, design, and create a miniaturised Cardio-Renal Pediatric Dialysis Emergency Machine (CARPEDIEM), specifically for neonates and small infants. We created the new device and assessed it with in-vitro laboratory tests, completed its development to meet regulatory requirements, and obtained a licence for human use. Once approved, we used the machine to treat a critically ill neonate FINDINGS: The main characteristics of CARPEDIEM are the low priming volume of the circuit (less than 30 mL), miniaturised roller pumps, and accurate ultrafiltration control via calibrated scales with a precision of 1 g. In-vitro tests confirmed that both hardware and software met the specifications. We treated a 2·9 kg neonate with haemorrhagic shock, multiple organ dysfunction, and severe fluid overload for more than 400 h with the CARPEDIEM, using continuous venovenous haemofiltration, single-pass albumin dialysis, blood exchange, and plasma exchange. The patient's 65% fluid overload, raised creatinine and bilirubin concentrations, and severe acidosis were all managed safely and effectively. Despite the severity of the illness, organ function was restored and the neonate survived and was discharged from hospital with only mild renal insufficiency that did not require renal replacement therapy. INTERPRETATION: The CARPEDIEM CRRT machine can be used to provide various treatment modalities and support for multiple organ dysfunction in neonates and small infants. The CARPEDIEM could reduce the range of indications for peritoneal dialysis, widen the range of indications for CRRT, make the use of CRRT less traumatic, and expand its use as supportive therapy even when complete renal replacement therapy is not indicated. FUNDING: Associazione Amici del Rene di Vicenza.


Assuntos
Injúria Renal Aguda/terapia , Rins Artificiais , Terapia de Substituição Renal/instrumentação , Injúria Renal Aguda/sangue , Bilirrubina/sangue , Biomarcadores/sangue , Creatinina/sangue , Desenho de Equipamento , Humanos , Lactente , Recém-Nascido , Terapia Intensiva Neonatal/métodos , Teste de Materiais/métodos , Insuficiência de Múltiplos Órgãos/sangue , Insuficiência de Múltiplos Órgãos/terapia , Estudos Prospectivos
18.
Blood Purif ; 40(2): 180-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26305014

RESUMO

BACKGROUND/AIM: Bisphenol A (BPA) is used in the production of many plastics, which are used to build biomaterials that sometimes are in direct contact with blood. It is believed that the release of BPA into bloodstream may give rise to cytotoxic events for blood components. The aim of the present study was to perform an in vitro investigation of the observable cytotoxic effect of BPA, at increasing concentrations, on the monocyte cell line. METHODS: We incubated in vitro monocyte cells (U937) for 24 h in cell line medium samples (RPMI 1640) at different concentrations of BPA. We then generated curves to evaluate viability, necrosis and apoptosis of monocytes against increasing concentrations of BPA. RESULTS: The percentage values of concentrations of BPA corresponding to 50% of the viability and necrosis of the monocytes were 1.39 and 1.48 ng/ml, respectively. Based on our observations, we reported an increasing cytotoxic effect for higher concentrations. The apoptotic effect reached the maximum value at BPA concentration of 1.5 ng/ml; at still higher concentrations, we observed a predominantly necrotic cell death. CONCLUSION: Viability, necrosis and apoptosis of monocytes are strongly and positively correlated with BPA concentration. A direct contact of such compound with biological components of blood may lead to high levels of cytotoxicity, and require us to evaluate additional factors while judging the bio-incompatibility of BPA.


Assuntos
Compostos Benzidrílicos/toxicidade , Disruptores Endócrinos/toxicidade , Poluentes Ambientais/toxicidade , Monócitos/efeitos dos fármacos , Necrose/induzido quimicamente , Fenóis/toxicidade , Apoptose/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Fragmentação do DNA/efeitos dos fármacos , Humanos , Concentração Inibidora 50 , Monócitos/patologia , Necrose/patologia
19.
Nephron Clin Pract ; 127(1-4): 172-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25343844

RESUMO

The provision of continuous renal replacement therapies (CRRT) to small children has generally required the adaptation of adult machines and modified operational characteristics. CRRT prescription for younger and smaller children versus adults differs significantly due to problems concerning the extracorporeal blood volume, the need for circuit blood priming, and the adaptation of machines designed for adult-sized patients. Moreover, the provision of renal replacement therapy to infants and neonates presents a unique problem: no more than 10-15% of their blood volume should be removed by the extracorporeal circuit to prevent hypotension and anemia. In 2012, a dedicated machine, i.e. the Cardio-Renal, Pediatric Dialysis Emergency Machine (CARPEDIEM), was developed and launched the 'fitted era' for pediatric CRRT. In this review, we analyze how CRRT techniques have evolved for pediatric application and describe the first in vivo application of the CARPEDIEM for the safe and efficacious provision of CRRT to infants.


Assuntos
Injúria Renal Aguda/terapia , Cuidados Críticos/métodos , Terapia de Substituição Renal/tendências , Injúria Renal Aguda/epidemiologia , Adolescente , Tamanho Corporal , Criança , Pré-Escolar , Desenho de Equipamento , Circulação Extracorpórea/instrumentação , Hemofiltração/instrumentação , Hemofiltração/tendências , Humanos , Lactente , Recém-Nascido , Terapia de Substituição Renal/instrumentação , Terapia de Substituição Renal/métodos , Dispositivos de Acesso Vascular/tendências
20.
Genes (Basel) ; 15(5)2024 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-38790182

RESUMO

INTRODUCTION: Cell-free nucleic acids (cf-NAs) represent a promising biomarker of various pathological and physiological conditions. Since its discovery in 1948, cf-NAs gained prognostic value in oncology, immunology, and other relevant fields. In peritoneal dialysis (PD), blood purification is performed by exposing the peritoneal membrane. Relevant sections: Complications of PD such as acute peritonitis and peritoneal membrane aging are often critical in PD patient management. In this review, we focused on bacterial DNA, cell-free DNA, mitochondrial DNA (mtDNA), microRNA (miRNA), and their potential uses as biomarkers for monitoring PD and its complications. For instance, the isolation of bacterial DNA in early acute peritonitis allows bacterial identification and subsequent therapy implementation. Cell-free DNA in peritoneal dialysis effluent (PDE) represents a marker of stress of the peritoneal membrane in both acute and chronic PD complications. Moreover, miRNA are promising hallmarks of peritoneal membrane remodeling and aging, even before its manifestation. In this scenario, with multiple cytokines involved, mtDNA could be considered equally meaningful to determine tissue inflammation. CONCLUSIONS: This review explores the relevance of cf-NAs in PD, demonstrating its promising role for both diagnosis and treatment. Further studies are necessary to implement the use of cf-NAs in PD clinical practice.


Assuntos
Ácidos Nucleicos Livres , DNA Mitocondrial , Diálise Peritoneal , Humanos , Diálise Peritoneal/efeitos adversos , Ácidos Nucleicos Livres/genética , Ácidos Nucleicos Livres/sangue , DNA Mitocondrial/genética , Biomarcadores , MicroRNAs/genética , DNA Bacteriano/genética , Peritonite/genética , Peritônio/metabolismo , Peritônio/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA