Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech ; 92: 162-168, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31164224

RESUMO

Post-mortem human subjects (PMHS) are frequently used to characterize biomechanical response and injury tolerance of humans to various types of loading by means of instrumentation installed directly on the skeleton. Data extracted from such tests are often used to develop and validate anthropomorphic test devices (ATDs), which function as human surrogates in tests for injury assessment. Given that the location and orientation of installed instrumentation differs between subjects, nominally similar measurements made on different PMHS must be transformed to standardized, skeletal-based local coordinate systems (LCS) before appropriate data comparisons can be made. Standardized PMHS LCS that correspond to ATD instrumentation locations and orientations have not previously been published. This paper introduces anatomically-defined PMHS LCS for body regions in which kinematic measurements are made using ATDs. These LCS include the head, sternum, single vertebrae, pelvis, femurs (distal and proximal), and tibiae (distal and proximal) based upon skeletal landmarks extracted from whole body CT scans. The proposed LCS provide a means to standardize the reporting of PMHS data, and facilitate both the comparison of PMHS impact data across institutions and the application of PMHS data to the development and validation of ATDs.


Assuntos
Osso e Ossos/anatomia & histologia , Cabeça/anatomia & histologia , Fenômenos Biomecânicos , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/fisiologia , Cadáver , Cabeça/diagnóstico por imagem , Cabeça/fisiologia , Humanos , Tomografia Computadorizada por Raios X , Ferimentos e Lesões/fisiopatologia
2.
J Biomech ; 69: 54-63, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29373114

RESUMO

Many post-mortem human subjects (PMHS) considered for use in biomechanical impact tests have pre-existing rib fractures (PERFs), usually resulting from cardiopulmonary resuscitation. These specimens are typically excluded from impact studies with the assumption that the fractures will alter the thoracic response to loading. We previously used the Global Human Body Models Consortium 50th percentile whole-body finite element model (GHBMC M50-O) to demonstrate that up to three lateral or bilateral PERFs do not meaningfully influence the response of the GHBMC thorax to lateral loading. This current study used the GHBMC M50-O to explore the influence of PERFs on thorax response in frontal and oblique loading. Up to six PERFs were simulated on the anterior or lateral rib regions, and the model was subjected to frontal or oblique cylindrical impactor, frontal seatbelt, or frontal seatbelt + airbag loading. Changes in thorax force-compression responses due to PERFs were generally minor, with the greatest alterations seen in models with six PERFs on one side of the ribcage. The observed changes, however, were small relative to mid-size male corridors for the loading conditions simulated. PERFs altered rib strain patterns, but the changes did not translate to changes in global thoracic response. Within the limits of model fidelity, the results suggest that PMHS with up to six PERFs may be appropriate for use in frontal or oblique impact testing.


Assuntos
Análise de Elementos Finitos , Fenômenos Mecânicos , Fraturas das Costelas/fisiopatologia , Tórax/fisiologia , Acidentes de Trânsito , Adulto , Fenômenos Biomecânicos , Cadáver , Humanos , Masculino , Pessoa de Meia-Idade , Cintos de Segurança
3.
Traffic Inj Prev ; 18(6): 642-649, 2017 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-28095025

RESUMO

OBJECTIVE: Although advanced restraint systems, such as seat belt pretensioners and load limiters, can provide improved occupant protection in crashes, such technologies are currently not utilized in military vehicles. The design and use of military vehicles presents unique challenges to occupant safety-including differences in compartment geometry and occupant clothing and gear-that make direct application of optimal civilian restraint systems to military vehicles inappropriate. For military vehicle environments, finite element (FE) modeling can be used to assess various configurations of restraint systems and determine the optimal configuration that minimizes injury risk to the occupant. The models must, however, be validated against physical tests before implementation. The objective of this study was therefore to provide the data necessary for FE model validation by conducting sled tests using anthropomorphic test devices (ATDs). A secondary objective of this test series was to examine the influence of occupant body size (5th percentile female, 50th percentile male, and 95th percentile male), military gear (helmet/vest/tactical assault panels), seat belt type (3-point and 5-point), and advanced seat belt technologies (pretensioner and load limiter) on occupant kinematics and injury risk in frontal crashes. METHODS: In total, 20 frontal sled tests were conducted using a custom sled buck that was reconfigurable to represent both the driver and passenger compartments of a light tactical military vehicle. Tests were performed at a delta-V of 30 mph and a peak acceleration of 25 g. The sled tests used the Hybrid III 5th percentile female, 50th percentile male, and 95th percentile male ATDs outfitted with standard combat boots and advanced combat helmets. In some tests, the ATDs were outfitted with additional military gear, which included an improved outer tactical vest (IOTV), IOTV and squad automatic weapon (SAW) gunner with a tactical assault panel (TAP), or IOTV and rifleman with TAP. ATD kinematics and injury outcomes were determined for each test. RESULTS: Maximum excursions were generally greater in the 95th percentile male compared to the 50th percentile male ATD and in ATDs wearing TAP compared to ATDs without TAP. Pretensioners and load limiters were effective in decreasing excursions and injury measures, even when the ATD was outfitted in military gear. CONCLUSIONS: ATD injury response and kinematics are influenced by the size of the ATD, military gear, and restraint system. This study has provided important data for validating FE models of military occupants, which can be used for design optimization of military vehicle restraint systems.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Tamanho Corporal , Equipamento de Proteção Individual , Cintos de Segurança , Ferimentos e Lesões/etiologia , Aceleração , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Manequins , Militares , Modelos Teóricos , Veículos Automotores , Risco
4.
J Gerontol A Biol Sci Med Sci ; 71(7): 858-65, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26809496

RESUMO

Rapamycin extends mouse life span, but the extent to which rapamycin prevents aging-associated changes in specific tissues remains unclear. Stiffness increases and collagen turnover decreases in mouse tendon with aging; thus, our aim was to determine the effect of long-term rapamycin treatment on the mechanical and structural properties of tendons from old mice. Tendons were harvested from female UM-HET3 mice maintained on a standard chow diet for 4 (adult) or 22 (old) months or fed chow containing polymer-encapsulated rapamycin (eRAPA) from 9 to 22 months of age (old RAPA). Stiffness was twofold higher for tendons of old compared with adult mice, but in old RAPA mice, tendon stiffness was maintained at a value not different from that of adults. Additionally, expression of collagen decreased, expression of matrix metalloproteinase-8 increased, and total hydroxyproline content trended toward decreased levels in tendons of old eRAPA-fed mice compared with controls. Finally, age-associated calcification of Achilles tendons and accompanying elevations in expression of chondrocyte and osteoblast markers were all lower in old eRAPA-fed mice. These results suggest that long-term administration of rapamycin alters the molecular pathways responsible for aging of tendon extracellular matrix, resulting in tissue that is structurally and mechanically similar to tendons in adult mice.


Assuntos
Envelhecimento , Fenômenos Biomecânicos , Colágeno/metabolismo , Elasticidade , Efeitos Adversos de Longa Duração , Sirolimo , Tendões , Envelhecimento/efeitos dos fármacos , Envelhecimento/patologia , Envelhecimento/fisiologia , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Fenômenos Biomecânicos/fisiologia , Elasticidade/efeitos dos fármacos , Elasticidade/fisiologia , Matriz Extracelular/efeitos dos fármacos , Matriz Extracelular/metabolismo , Matriz Extracelular/fisiologia , Feminino , Hidroxiprolina/metabolismo , Imunossupressores/metabolismo , Imunossupressores/farmacologia , Efeitos Adversos de Longa Duração/etiologia , Efeitos Adversos de Longa Duração/patologia , Efeitos Adversos de Longa Duração/fisiopatologia , Metaloproteinase 8 da Matriz/metabolismo , Camundongos , Músculo Esquelético/fisiopatologia , Sirolimo/metabolismo , Sirolimo/farmacologia , Tendões/metabolismo , Tendões/patologia , Tendões/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA