Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Nano Lett ; 24(10): 3282-3289, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38421230

RESUMO

X-ray radiation information storage, characterized by its ability to detect radiation with delayed readings, shows great promise in enabling reliable and readily accessible X-ray imaging and dosimetry in situations where conventional detectors may not be feasible. However, the lack of specific strategies to enhance the memory capability dramatically hampers its further development. Here, we present an effective anion substitution strategy to enhance the storage capability of NaLuF4:Tb3+ nanocrystals attributed to the increased concentration of trapping centers under X-ray irradiation. The stored radiation information can be read out as optical brightness via thermal, 980 nm laser, or mechanical stimulation, avoiding real-time measurement under ionizing radiation. Moreover, the radiation information can be maintained for more than 13 days, and the imaging resolution reaches 14.3 lp mm-1. These results demonstrate that anion substitution methods can effectively achieve high storage capability and broaden the application scope of X-ray information storage.

2.
Inorg Chem ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38950326

RESUMO

Inorganic materials doped with chromium (Cr) ions generate remarkable and adjustable broadband near-infrared (NIR) light, offering promising applications in the fields of imaging and night vision technology. However, achieving high efficiency and thermal stability in these broadband NIR phosphors poses a significant challenge for their practical application. Here, we employ crystal field engineering to modulate the NIR characteristics of Cr3+-doped Gd3Ga5O12 (GGG). The Gd3MgxGa5-2xGexO12 (GMGG):7.5% Cr3+ (x = 0, 0.05, 0.15, 0.20, and 0.40) phosphors with NIR emission are developed through the cosubstitution of Mg2+ and Ge4+ for Ga3+ sites. This cosubstitution strategy also effectively reduces the crystal field strength around Cr3+ ions, which results in a significant enhancement of the photoluminescence (PL) full width at half-maximum (fwhm) from 97 to 165 nm, alongside a red shift in the PL peak and an enhancement of the PL intensity up to 2.3 times. Notably, the thermal stability of the PL behaviors is also improved. The developed phosphors demonstrate significant potential in biological tissue penetration and night vision, as well as an exceptional scintillation performance for NIR scintillator imaging. This research paves a new perspective on the development of high-performance NIR technology in light-emitting diodes (LEDs) and X-ray imaging applications.

3.
BMC Ophthalmol ; 24(1): 94, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429639

RESUMO

BACKGROUND: Most studies had shown a linear relationship between serum albumin (sALB) and the prevalence of diabetic retinopathy (DR). Thus, the purpose of this study is to investigate whether their relationship is non-linear. METHODS: We included 426 patients with type 2 diabetes who were hospitalized in Guangdong Provincial People's Hospital from December 2017 to November 2018. The outcome was the prevalence of DR. A two-piecewise logistics regression model was performed to identify the non-linear relationship between sALB and the prevalence of DR. The inflection point was calculated to determine the saturation effect through the maximum likelihood ratio and a recursive algorithm. RESULTS: DR was diagnosed in 167 of 426 type 2 diabetic patients. The relationship between sALB and DR was nonlinear. When sALB was less than 38.10 g/L, a significant negative association was observed (OR = 0.82; 95% CI, 0.72-0.94; P = 0.0037), while no significant association was observed when sALB was greater than 38.10 g/L (OR = 1.12; 95% CI, 0.92-1.35; P = 0.2637). CONCLUSIONS: The relationship between sALB and the prevalence of DR is non-linear. sALB is negatively associated with the prevalence of DR when sALB is less than 38.10 g/L. Our findings need to be confirmed by further prospective research.


Assuntos
Diabetes Mellitus Tipo 2 , Retinopatia Diabética , Humanos , Algoritmos , Estudos Transversais , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/sangue , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/metabolismo , Albumina Sérica
4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 37(2): 607-11, 2017 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-30292180

RESUMO

In order to research the effect of X-ray fluorescence (XRF) analysis on the results in the sample's micro particles, MCNPX models had been established for an X-ray fluorescence analyzer in this paper. It had studied the characteristics of the samples with different particle sizes, the fluorescence peak counts, the peak to total ratios and the peak to source ratios. A micro particle analysis experiment had been designed for its verification. The results showed that: as for the relationship between the fluorescence intensity and the particle sizes, the MCNPX calculations were consistent with the theoretical, but contrary with the experimental results; the reason is that some hypotheses about samples in the MCNPX models were contrary with the actual states; the samples were crushed by grinding to small particles and tableting process, the MCNPX calculations and experimental results can be conversion; when the particle sizes of the samples reached the certain sizes, the fluorescence peak counts, the peak to total ratios and the peak to source ratios were stable value; within a particular size range, the influence of the particle size effects cannot be ignored, otherwise this influence can be ignored. The research methods and conclusions in this paper can provide a technical reference guide for X-ray analysis in practices.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 37(1): 262-6, 2017 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-30221889

RESUMO

Semiconductor detector is widely used in energy dispersive X-ray fluorescence measurements due to its excellent performance. In this paper, Si-PIN and CdTe semiconductor detectors were studied, performances of the two detectors were compared in material properties, detection efficiency, energy resolution and other aspects. Focused on the performance of the detectors influenced by the thickness of detector sensitive area, energy of incident X-ray, shaping time of post-stage circuit, and analyzed the differences of energy spectrum caused by escape peaks and hole trailing. Aiming at the problem of incomplete hole collection in detector, a digital multi-channel analyzer (DMCA) based on FPGA with rise-time discriminator was designed, it could reduce the influence of hole trailing effectively and improve energy resolution. The experimentation results indicate that the detection efficiency of Si-PIN and CdTe is roughly equal when energy is below 15 keV while CdTe has much higher detection efficiency than Si-PIN when energy is above 15 keV. The optimum forming time of the Si-PIN detector is about 10 µs, and the CdTe detector is about 2.6 µs, so the CdTe detector is more suitable for the high count rate condition. Si-PIN detector has better energy resolution than CdTe detector for different energy incident X-ray. CdTe detector has obvious hole tailing effect and the energy resolution of CdTe detector is significantly improved by using DMCA with rise-time discrimination.

6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(3): 868-73, 2016 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-27400540

RESUMO

Monitoring atmospheric particulate matter requires real-time analysis, such as particulate matter's concentrations, their element types and contents. An analyzer which is based on ß and X rays analysis techniques is designed to meet those demands. Applying ß-ray attenuation law and energy dispersive X-ray fluorescence analysis principle, the paper introduces the analyzer's overall design scheme, structure, FPGA circuit hardware and software for the analyzer. And the analyzer can measure atmospheric particulate matters' concentration, elements and their contents by on-line analysis. Pure elemental particle standard samples were prepared by deposition, and those standard samples were used to set the calibration for the analyzer in this paper. The analyzer can monitor atmospheric particulate matters concentration, 30 kinds of elements and content, such as TSP, PM10 and PM2.5. Comparing the measurement results from the analyzer to Chengdu Environmental Protection Agency's monitoring results for monitoring particulate matters, a high consistency is obtained by the application in eastern suburbs of Chengdu. Meanwhile, the analyzer are highly sensitive in monitoring particulate matters which contained heavy metal elements (such as As, Hg, Cd, Cr, Pb and so on). The analyzer has lots of characteristics through technical performance testing, such as continuous measurement, low detection limit, quick analysis, easy to use and so on. In conclusion, the analyzer can meet the demands for analyzing atmospheric particulate matter's concentration, elements and their contents in urban environmental monitoring.

7.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(4): 1235-9, 2016 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-30052354

RESUMO

X-ray tube is the most commonly used equipment in X-ray fluorescence spectrum analysis as excitation source whose primary spectrum has become a major source of the background of X-ray fluorescence spectrum. Background subtraction should go before further analysis of this spectrum. The accuracy of the estimation of the background directly affect the results of subsequent processing steps. In this paper, the tube excitation component of X fluorescence spectrum is analyzed with an estimation method of background intensity against their background characteristics, and structuring theoretical spectral lines based on the measured spectral lines in order to evaluate the effect of spectral processing algorithms. The method utilizes the measured X-ray fluorescence spectrum which does not contain the characteristic peak of the spectrum, In order to estimate the composition of the original spectrum of the X-ray tube. It uses the spectrum that contains the continuous background for interpolating the entire measured spectrum, thereby avoiding overlapping the spectral characteristic peaks or improperly estimating full width at half maximum. This paper compared SNIP, Fourier transform method and the background subtraction method using the measured spectral lines. Using this method to estimate the background is closer to the theoretical background. The results showe that the method for X-ray fluorescence spectrum by X-ray tube excitation is accurate in this article, this method can be used to deduct continuous background, and good applied effectiveness has been achieved in the background subtraction of the actually measured X-ray fluorescence spectrometry.

8.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(7): 2034-7, 2015 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-26717774

RESUMO

The X-ray Fluorescence Analysis(XRFA) is an important and efficient method on the element anylsis and is used in geology, industry and environment protection. But XRFA has a backdraw that the determination limit and accuracy are effected by the matrix of the sample. Now the fundamental parameter is usually used to calculate the content of elements in XRFA, and it is an efficient method if the matrix and net area of characteristic X-ray peak are obtained. But this is invalide in in-stu XRFA. Also the method of net area and the "black material" of sample are the key point of the fundamental parameter method when the Energy Dispersive X-ray Fluorescence Analysis(EDXRFA) method is used in the low content sample. In this paper a advanced fundamental parameter method is discussed. The advanced fundamental parameter method includes the spectra analysis and the fundamental parameter method, which inserts the overlapping peaks separation method into the iteration process of the fundamental parameter method. The advanced method can resolve the net area and the quantitative analysis. The advanced method is used to analyse the standard sample. Compare to the content obtained from the coefficient method, the precision of Cu, Ni and Zn is better than coeffieciency method. The result shows that the advanced method could improve the precision of the EDXRFA, so the advanced method is better than the coefficient method.

9.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(2): 562-4, 2014 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-24822440

RESUMO

In the energy dispersive X-ray fluorescence spectrum analysis, scintillation detector such as NaI (Tl) detector usually has a low energy resolution at around 8%. The low energy resolution causes problems in spectral data analysis especially in the high background and low counts condition, it is very limited to strip the overlapped spectrum, and the more overlapping the peaks are, the more difficult to peel the peaks, and the qualitative and quantitative analysis can't be carried out because we can't recognize the peak address and peak area. Based on genetic algorithm and immune algorithm, we build a new racial algorithm which uses the Euclidean distance as the judgment of evolution, the maximum relative error as the iterative criterion to be put into overlapped spectrum analysis, then we use the Gaussian function to simulate different overlapping degrees of the spectrum, and the racial algorithm is used in overlapped peak separation and full spectrum simulation, the peak address deviation is in +/- 3 channels, the peak area deviation is no more than 5%, and it is proven that this method has a good effect in energy dispersive X-ray fluorescence overlapped spectrum analysis.

10.
Curr Pharm Des ; 30(9): 666-675, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38415446

RESUMO

BACKGROUND: With the urgent and widespread application of Paxlovid, a novel antiviral drug for Coronavirus Disease 2019 (COVID-19) in clinical practice, concerns regarding its actual efficacy and safety have emerged. In order to provide more evidence to support its clinical application, we sought to perform a descriptive analysis of cases who experienced at least one Paxlovid-related adverse event (AEs) and reported to the FDA Adverse Event Reporting System (FAERS) in the post-marketing period. METHODS: Individual adverse event reports between January 1, 2022 and September 30, 2022, were downloaded from the FAERS website. We completed a descriptive study about the safety of Paxlovid in the treatment of COVID-19. Further, we also analyzed the onset time of Paxlovid-related AEs. RESULTS: As of 30 September 2022, 16,529 de-duplicated cases were submitted to the FDA, and 5,860 (35.45%) were female. The average age was 58.38 years (S.D. 15.50). Most reports (12,390, 74.96%) were submitted by consumers and 1,436 (8.68%) concerned serious outcomes. The most frequently reported AEs were disease recurrence (7,724, 16.23%), dysgeusia (2,877, 6.05%), and diarrhoea (1,448, 3.04%). The median onset time of Paxlovid-related AEs was 8 days (interquartile range,1-10 days), and most of the cases (2,629, 19.12%) occurred on the day after Paxlovid initiation. CONCLUSION: This study indicates that the most common AEs reported with Paxlovid in post-marketing experience are consistent with the safety assessment of antiviral drugs. Even without emerging apparent safety concerns, the incidence of serious outcomes was unexpectedly high, and a few cases of potential new AEs occurred.


Assuntos
Antivirais , Tratamento Farmacológico da COVID-19 , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Antivirais/efeitos adversos , Antivirais/uso terapêutico , COVID-19/epidemiologia , Idoso , Adulto , SARS-CoV-2/efeitos dos fármacos , Estados Unidos/epidemiologia , Sistemas de Notificação de Reações Adversas a Medicamentos , United States Food and Drug Administration
11.
Appl Radiat Isot ; 208: 111311, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38593592

RESUMO

Waste liquid stored in the containment sumps of nuclear power plants may contain a variety of radionuclides. Real-time monitoring of containment sump waste liquid can ensure that accidents, such as leakage of cooling water, can be avoided. This paper presents the design of a radioactive monitoring system for waste liquid in a containment sump. The detector and the lead-shield in the measurement unit are optimized through Monte Carlo simulations. Experimental verification showed that the background count rate of the measurement chamber in the system was 418.3 cps, and the detection limit of the detection system was 3.01 Bq/L. Distinct gamma-ray characteristic peaks were also observable, demonstrating the system's ability to identify radioactive nuclides in the waste.

12.
ACS Appl Mater Interfaces ; 16(22): 29210-29216, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38770774

RESUMO

Cs3Cu2I5 nanocrystals (NCs) are considered to be promising materials due to their high photoluminescence efficiency, lack of lead toxicity, and X-ray responsiveness. However, during the crystallization process, NCs are prone to agglomeration and exhibit uneven size distribution, resulting in several light scattering that severely affect their imaging resolution. Herein, we successfully developed a high-resolution scintillator film by growing copper-based perovskite NCs within a hybrid polymer matrix. By leveraging the ingenious integration of polyvinylidene fluoride (PVDF) and polymethyl methacrylate (PMMA), the size and distribution uniformity of Cs3Cu2I5 NCs can be effectively controlled. Consequently, a high spatial resolution of 14.3 lp mm-1 and a low detection limit of 105 nGy s-1 are achieved, and the scintillator film has excellent flexibility and stability. These results highlight the promising application of Cs3Cu2I5 scintillator films in low-cost, flexible, and high-performance medical imaging.

13.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(8): 2231-4, 2013 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-24159883

RESUMO

The transmission anode micro X-ray tube is a key component of energy dispersive X-ray Fluorescence Analysis (EDXRFA) as exciting source. So in EDXRFA we hope to get the primary X-ray spectrum which is simply distributed. In the present paper, the authors used the Monte Carlo (MC) method to study the spectrum character of the transmission anode micro X-ray tube with different thickness of target. We cut the spectrum into high energy (5keV-50keV) part and low energy (< 5 keV) part and compared them to each other. The result showed that the flux of high energy part is big and the flux of low energy part is small when the electron energy is 50 keV and the target is 4 microm thick Ag. This is better for EDXRFA.

14.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(9): 2583-5, 2013 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-24369677

RESUMO

In energy dispersive X-ray fluorescence analysis technical analysis, the spectrum information processing has been being the focus of researches, spectrum smooth, peak-search, and peak area processing are the top priority, tA peak search method is based on simulated annealing algorithm principle, and to establish a new search peak model algorithm, this algorithm uses the advantages of the global convergence properties of simulated annealing and the Metropolis criterion is used as a peak valley judgment basis. A new decision criteria on peak valley array is used in this method, too. At the same time, convergence is taken from both ends of the spectrum channel address, it ends up when convergence reaches to the same optimal solution. This paper compared the algorithm with the simple comparison method, third derivative method, and the contrast experiment results, showing that this algorithm has a strong ability on X-ray fluorescence spectrum peak-search and a certain value in the actual production.

15.
Front Microbiol ; 14: 1331477, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38274757

RESUMO

As the environmental nuclear radiation pollution caused by nuclear-contaminated water discharge and other factors intensifies, more plant-microorganism-soil systems will be under long-term low-dose ionizing radiation (LLR). However, the regulatory mechanisms of the plant-microorganism-soil system under LLR are still unclear. In this study, we study a system that has been stably exposed to low-dose ionizing radiation for 10 years and investigate the response of the plant-microorganism-soil system to LLR based on the decay of the absorbed dose rate with distance. The results show that LLR affects the carbon and nitrogen migration process between plant-microorganism-soil through the "symbiotic microbial effect." The increase in the intensity of ionizing radiation led to a significant increase in the relative abundance of symbiotic fungi, such as Ectomycorrhizal fungi and Rhizobiales, which is accompanied by a significant increase in soil lignin peroxidase (LiP) activity, the C/N ratio, and C%. Meanwhile, enhanced radiation intensity causes adaptive changes in the plant functional traits. This study demonstrates that the "symbiotic microbial effect" of plant-microorganism-soil systems is an important process in terrestrial ecosystems in response to LLR.

16.
Biomed Pharmacother ; 158: 114068, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36495659

RESUMO

Targeted gene therapy has shown durable efficacy in non-neoplastic and neoplastic patients. Therefore, finding a suitable target has become a key area of research. Mesenchyme homeobox 1 (MEOX1) is a transcriptional factor that plays a significant role in regulation of somite development. Evidence indicates that abnormalities in MEOX1 expression and function are associated with a variety of pathologies, including non-neoplastic and neoplastic diseases. MEOX1 expression is upregulated during progression of most diseases and plays a critical role in maintenance of the cellular phenotypes such as cell differentiation, cell cycle arrest and senescence, migration, and proliferation. Therefore, MEOX1 may become an important molecular target and therapeutic target. This review will discuss the current state of knowledge on the role of MEOX1 in different diseases.


Assuntos
Proteínas de Homeodomínio , Neoplasias , Humanos , Proteínas de Homeodomínio/genética , Proteínas de Homeodomínio/metabolismo , Fatores de Transcrição/metabolismo , Regulação da Expressão Gênica , Diferenciação Celular , Neoplasias/genética , Senescência Celular , Regulação Neoplásica da Expressão Gênica
17.
Appl Radiat Isot ; 192: 110596, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36549179

RESUMO

Radioactive material inspection in public is important to nuclear safety, and it is also the key security for holding large-scale events, while fast and efficient means of detecting radioactive materials are an important technical guarantee for nuclear safety. In this paper, energy and time distribution characteristics information of the natural background and target nuclide gamma particles are used to improve the sequential background comparison method. By using those energy and time distribution characteristics information, with the half-life and characteristic gamma-ray energy and branching ratio information of the nuclide, the response time and the identification accuracy of extremely low radioactive nuclides detected under natural-radiation background can be improved. Based on the theoretical research, the particle event acquisition device with the LaBr3(Ce) detector was used to carry out the experimental verification, and the results show that, this method can identify 137Cs (characteristic energy of 0.662 MeV,8700 Bq,the position relative to the detector is 30 cm) in 6.2 s, and identify 60Co (characteristic energy of 1.173 MeV and 1.332 MeV, 4500 Bq, the position relative to the detector is 15 cm) in 5.9 s. Experiments prove that the improved background comparison-based sequential Bayesian method can identify low radioactivity radionuclides under natural-radiation background rapidly.


Assuntos
Monitoramento de Radiação , Radioatividade , Poluentes Radioativos do Solo , Teorema de Bayes , Poluentes Radioativos do Solo/análise , Meia-Vida , Radiação de Fundo
18.
Sci Rep ; 13(1): 9881, 2023 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-37336896

RESUMO

Blood urea nitrogen (BUN) is an indicator of renal function and catabolic status in human body. Diabetic retinopathy (DR) is a major microvascular complication of diabetes mellitus (DM) and a serious threat to the vision of diabetic patients. We included 426 type 2 diabetic patients who visited the endocrinology department of Guangdong Provincial People's Hospital and received an ophthalmology consultation from December 2017 to November 2018. The outcome was the probability of DR in participants. Multivariable logistics analysis was used to confirm the relationship between BUN and the probability of DR. And interaction tests were conducted to find the effects of DM duration on their association. A total of 167 of 426 patients with type 2 diabetes had DR, with a probability of 39.20%. After adjusting for potential confounders, a positive association between BUN and the probability of DR (OR = 1.12; 95% CI 1.03-1.21; P = 0.0107). And a test for interaction between DM duration and BUN on the probability of DR was significant (P = 0.0295). We suggested that in patients with type 2 diabetes, BUN was positively associated with the probability of DR and the association was influenced by DM duration.


Assuntos
Diabetes Mellitus Tipo 2 , Retinopatia Diabética , Humanos , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/complicações , Nitrogênio da Ureia Sanguínea , Estudos Transversais , Fatores de Risco
19.
ACS Appl Mater Interfaces ; 11(7): 7522-7528, 2019 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-30693756

RESUMO

An important factor for the high performance of light-harvesting devices is the presence of surface trappings. Therefore, understanding and controlling the carrier recombination of the organic-inorganic hybrid perovskite surface is critical for the device design and optimization. Here, we report the use of aluminum zinc oxide (AZO) as the anode to construct a p-n junction structure MAPbBr3 nuclear radiation detector. The AZO/MAPbBr3/Au detector can tolerate an electrical field of 500 V·cm-1 and exhibit a very low leakage current of ∼9 nA, which is 1 order of magnitude lower than that of the standard ohmic contact device. The interface state density of AZO/MAPbBr3 contact was reduced from 2.17 × 1010 to 8.7 × 108 cm-2 by annealing at 100 °C under an Ar atmosphere. Consequently, a photocurrent to dark current ratio of 190 was realized when exposed to a green light-emitting diode with a wavelength of 520 nm (∼200 mW·cm-2). Simultaneously, a high X-ray sensitivity of ∼529 µC·Gyair-1 cm-2 was achieved under 80 kVp X-ray at an electric field of 50 V·cm-1. These results demonstrate the use of surface engineering to further optimize the performance of MAPbBr3 detectors, which have many potential applications in medical and security detection with low radiation dose brought to the human body.

20.
Comput Math Methods Med ; 2018: 1981627, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30647768

RESUMO

Blood pressure (BP) is one of the indispensable elements of physiological health characteristics and a significant indicator for predicting and diagnosing hypertension and cardiovascular diseases. This paper proposes a two-domain fusion model to estimate BP continuously from pulse wave acquired with a pressure sensor. Method. The optimal external pressure applied on the pressure sensor is first determined in order to capture pulse wave in the radial artery. The captured pulse wave is then processed in both the time and frequency domains via filtering and fast Fourier transform. Finally, a set of features are extracted from these two domains and input into a neural network along with blood pressure values measured by a commercial sphygmomanometer for training. The model is then tested on new data for accuracy evaluation. Results. The proposed two-domain fusion method achieved a high degree of accuracy in measuring blood pressure.


Assuntos
Determinação da Pressão Arterial/estatística & dados numéricos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/instrumentação , Análise de Fourier , Humanos , Modelos Estatísticos , Redes Neurais de Computação , Análise de Onda de Pulso/estatística & dados numéricos , Artéria Radial/fisiologia , Reprodutibilidade dos Testes , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA